Commit | Line | Data |
---|---|---|
84c27c41 | 1 | libcec (1.0-1) unstable; urgency=low |
5984d274 LOK |
2 | |
3 | * interface changes: | |
4 | * set lib interface version back to 1.0 and rename GetLibVersion() to | |
5 | GetLibVersionMajor() and GetMinVersion() to GetMinLibVersion() | |
6 | * added GetLibVersionMinor()/cec_get_lib_version_minor() and set the minor | |
7 | version number to 1 | |
8 | * fixed: | |
9 | * samsung's vendor specific remote keypresses don't send key releases. added | |
10 | call to AddKey() directly after the keypress | |
11 | * always reset the button press time in CLibCEC::AddKey() | |
12 | * always wait for a signal in CCECProcessor::Transmit() | |
13 | * changed: | |
14 | * drop shared_ptr and use a normal pointer. removed boost dependency | |
15 | ||
16 | -- Pulse-Eight Packaging <packaging@pulse-eight.com> Fri, 04 Nov 2011 00:14:00 +0100 | |
17 | ||
b3efc8f2 LOK |
18 | libcec (0.8-2) unstable; urgency=low |
19 | ||
20 | * added 'libboost-dev' to build deps | |
21 | ||
22 | -- Pulse-Eight Packaging <packaging@pulse-eight.com> Tue, 01 Nov 2011 23:31:00 +0100 | |
23 | ||
971d0e9e LOK |
24 | libcec (0.8-1) unstable; urgency=low |
25 | ||
26 | * interface changes: | |
27 | * added GetDevicePowerStatus()/cec_get_device_power_status() | |
28 | * added GetDeviceVendorId()/cec_get_device_vendor_id() | |
29 | * added GetDeviceMenuLanguage()/cec_get_device_menu_language() | |
30 | * added GetDeviceCecVersion()/cec_get_device_cec_version() | |
31 | * added SwitchMonitoring()/cec_switch_monitoring() to the interface. when | |
b3efc8f2 LOK |
32 | monitoring is enabled, the device will only log the data it received, |
33 | but will not respond to any message | |
971d0e9e | 34 | * removed timeout parameter in Transmit() and included the ack timeout in |
b3efc8f2 | 35 | the cec_command struct |
971d0e9e LOK |
36 | * made the vendor id -> vendor name translation available |
37 | * made CEC_LOG levels powers of 2 | |
38 | * introduced CEC_LOG_TRAFFIC log level | |
39 | * fixed: | |
40 | * set the correct ackmask on startup | |
41 | * wait for ack while keeping a lock | |
42 | * wait for the processor thread to start before continueing on startup | |
43 | * wait for messages to be transmitted before continueing in | |
b3efc8f2 | 44 | CCECProcessor::Transmit() |
971d0e9e LOK |
45 | * only set the logical address once when it has changed |
46 | * correct source for broadcast messages | |
47 | * win32: create Release type installer | |
48 | * changed: | |
49 | * make all reads and write in CAdapterCommunication go through buffers. | |
50 | * poll for a vendor ID of connected devices and switch to a non-standard | |
b3efc8f2 | 51 | CEC implementation if needed. |
971d0e9e LOK |
52 | * added vendor detection of Samsung and LG devices |
53 | * handle samsung remote command 'return' | |
54 | * cec-client: | |
55 | * added -la and --logical-address to the command line params | |
56 | * added -d and --log-level params to cec-client | |
57 | * added -sf and --short-log-file, which only log the actual messages, not | |
b3efc8f2 | 58 | the level and timestamp |
971d0e9e LOK |
59 | * added -f and --log-file parameters to cec-client |
60 | * added option to change the log level to cec-client | |
61 | ||
b3efc8f2 | 62 | -- Pulse-Eight Packaging <packaging@pulse-eight.com> Tue, 01 Nov 2011 22:58:00 +0100 |
971d0e9e | 63 | |
8f084f00 LOK |
64 | libcec (0.7-1) unstable; urgency=low |
65 | ||
66 | * send a keypress with 0 duration when a key is pressed and with a duration | |
67 | set when it's released | |
68 | * added SetOSDString() to the interface (not supported by all tvs) | |
69 | * fixed: 'routing change' is a broadcast message. log routing changes, but | |
70 | don't send a 'set active view' message, so the active input won't be | |
71 | changed | |
72 | * log keypresses in the debug log | |
73 | * added 'pa' command to cec-client, to change the physical address | |
74 | * added SetPhysicalAddress()/cec_set_physical_address() to the interface, so | |
75 | the HDMI port number to use can be changed | |
76 | * fixed: put the message processing code from WaitForAck() in ParseMessage(). | |
77 | fixes missing incoming message logging of non-data messages when not | |
78 | waiting for an ACK | |
79 | * added 'txn' command to cec-client. same as 'tx', but doesn't wait for ACK | |
80 | before returning | |
81 | * fixed: set initiator and destination first in cec_command::push_back(). | |
82 | fixes 'tx' command in cec-client | |
83 | * fixed: keep trying to connect while iTimeout isn't reached (default 10 | |
84 | seconds). fixes exit with a 'permission denied' error when the device isn't | |
85 | ready yet. remove CEC_SETTLE_DOWN_TIME | |
86 | * fixed: don't call SetActiveView() when reporting the power status. fixes | |
87 | loop which causes some TVs to report failed connections | |
88 | * fixed: eom was not being parsed when receiving MSGCODE_FRAME_DATA. fixed. | |
89 | * fixed: add the device type as parameter when sending the physical address. | |
90 | thanks bobo1on1 | |
91 | * fixed: typo in libcec.pc.in | |
92 | * added optional strLib parameter to LoadLibCec(), so the location of the | |
93 | shared library can be specified | |
94 | * only link cec-client against ld. use AC_SEARCH_LIBS instead of AC_CHECK_LIB | |
95 | * use int instead of bool on the public C interface and remove stdbool.h include | |
96 | * renamed: CECExports.h => cec.h, CECExportsC.h => cecc.h, CECLoader.h => | |
97 | cecloader.h, CECTypes.h => cectypes.h | |
98 | * updated debian package. split up libcec and libcec-dev | |
99 | * fixed: changed to use dlopen instead of static linkage. shuffled headers a | |
100 | bit. bumped interface to version 7 | |
101 | * removed 'rt' from libraries. it's not needed (anymore) | |
102 | * fixed: reset the active view after a routing change. issue #1 | |
103 | * fixed: changed attached license to be GPLv2 instead of GPLv3 this was an | |
104 | error as libCEC is licensed GPLv2 not GPLv3 thanks @garbear | |
105 | * added contributors link | |
106 | ||
107 | -- Pulse-Eight Packaging <packaging@pulse-eight.com> Fri, 14 Oct 2011 17:34:00 +0200 | |
108 | ||
11d0a2d6 LOK |
109 | libcec (0.6-1) unstable; urgency=low |
110 | ||
111 | * bumped interface version to 6 | |
112 | * fixed packet output (reporting the OSD name correctly now) | |
113 | * refactored packet structs: split up in cec commands and adapter messages | |
114 | * fixed i/o timings | |
115 | * added Darwin support (thanks Davilla!) | |
116 | * fixed WaitForAck() | |
117 | * fixed possible deadlock when starting a new thread | |
118 | * implemented vendor id and device class parsing. full detection will follow | |
119 | * added "on" and "standby" commands to the test client | |
120 | * retransmit packets if needed | |
121 | * fix GetTimeMs() on linux | |
122 | * added timestamp to log messages | |
123 | ||
124 | -- Pulse-Eight Packaging <packaging@pulse-eight.com> Sun, 09 Oct 2011 15:15:00 +0200 | |
125 | ||
9519c249 | 126 | libcec (0.5-1) unstable; urgency=low |
25701fa6 LOK |
127 | |
128 | * bumped interface version to 5 | |
129 | * don't pass std::string and std::vector accross the interface | |
130 | * fixed heap corruption crashes on windows | |
131 | * fixed some memory leaks | |
132 | * reset all structs to default values before doing with them | |
133 | ||
11d0a2d6 | 134 | -- Pulse-Eight Packaging <packaging@pulse-eight.com> Fri, 07 Oct 2011 22:00:00 +0200 |
25701fa6 | 135 | |
262f3b05 LOK |
136 | libcec (0.4-3) unstable; urgency=low |
137 | ||
138 | * fixed reconnect | |
139 | * fixed some threading related bugs | |
140 | * fixed deadlock on exit | |
141 | * fixed wrongly reported physical address | |
142 | ||
143 | -- Pulse-Eight Packaging <packaging@pulse-eight.com> Thu, 06 Oct 2011 00:19:00 +0200 | |
144 | ||
4463fb80 LOK |
145 | libcec (0.4-2) unstable; urgency=low |
146 | ||
147 | * fixed int parameter sizes and some signed/unsigned warnings | |
148 | * check whether m_port isn't NULL in ReadFromDevice | |
149 | * stop the processor thread and delete the CSerialPort instance on exit | |
150 | * added mutex in CSerialPort | |
151 | * fix segfault on exit | |
152 | * renamed libPlatform -> platform. | |
153 | * stuck everything from libCEC in the CEC namespace to avoid namespace | |
154 | polution | |
155 | ||
156 | -- Pulse-Eight Packaging <packaging@pulse-eight.com> Tue, 04 Oct 2011 23:45:00 +0200 | |
157 | ||
88c5a743 LOK |
158 | libcec (0.4-1) unstable; urgency=low |
159 | ||
160 | * bumped interface version to 4 | |
161 | * timeout parameter removed from Close()/cec_close(). return type changed to | |
162 | void | |
163 | * added cec_destroy() method | |
164 | * removed timeout parameter from Transmit() | |
165 | * change the default argument of PowerOnDevices() to CECDEVICE_TV | |
166 | * removed PowerOffDevices(). use StandbyDevices() instead | |
167 | * removed obsolete methods from the interface | |
168 | * fixed bug: pthread_cond_wait was called without the mutex locked | |
169 | * fixed possible deadlock: don't send messages and wait for an ack with the | |
170 | mutex locked in CCECParser | |
171 | * created a separate reader thread and fixed the 'lock timeout' bug | |
172 | * testclient: use CECDEVICE_TV instead of the default argument | |
173 | (CECDEVICE_BROADCAST) for PowerOnDevices() and PowerOffDevices() | |
174 | ||
175 | -- Pulse-Eight Packaging <packaging@pulse-eight.com> Tue, 04 Oct 2011 00:48:00 +0200 | |
176 | ||
a9bb5b56 LOK |
177 | libcec (0.3-1) unstable; urgency=low |
178 | ||
179 | * added device detection support for Windows | |
180 | ||
181 | -- Pulse-Eight Packaging <packaging@pulse-eight.com> Sun, 02 Oct 2011 12:09:33 +0200 | |
182 | ||
c3f9951c LOK |
183 | libcec (0.2-1) unstable; urgency=low |
184 | ||
185 | * added a Close() method to the interface | |
186 | * Added CEC command that were received by the adapter in a buffer that can be | |
187 | read by a client with GetNextCommand()/cec_get_next_command(). added a | |
188 | 'help' command to the test client, that displays all available commands | |
189 | * Fixed setting the ackmask. deprecated SetAckMask()/cec_set_ack_mask(). use | |
190 | SetLogicalAddress()/cec_set_logical_address() instead. add 'la' command to | |
191 | the testclient to set the logical address of the cec adapter | |
192 | * Added optional logical and physical address parameters to | |
193 | LoadLibCec()/cec_init() on the interface. fixed wrongly placed namespace | |
194 | close tag in CECExports.h. updated interface documentation. bumped | |
195 | interface version to 2. | |
196 | * fixed hardcoded ackmask in SetAckMast(). set a shorter display name in the | |
197 | test client. the previous one was too long and being rejected | |
198 | ||
199 | -- Pulse-Eight Packaging <packaging@pulse-eight.com> Fri, 28 Sep 2011 01:33:00 +0200 | |
200 | ||
abbca718 LOK |
201 | libcec (0.1-1) unstable; urgency=low |
202 | ||
203 | * Initial release v0.1 | |
204 | ||
205 | -- Pulse-Eight Packaging <packaging@pulse-eight.com> Wed, 28 Sep 2011 23:55:48 +0200 |