Track ATG status on a per connector basis.
[e-mobility-charging-stations-simulator.git] / src / charging-station / ocpp / 1.6 / OCPP16RequestService.ts
CommitLineData
c8eeb62b
JB
1// Partial Copyright Jerome Benoit. 2021. All Rights Reserved.
2
4a1857a2 3import { ACElectricUtils, DCElectricUtils } from '../../../utils/ElectricUtils';
c0560973 4import { AuthorizeRequest, OCPP16AuthorizeResponse, OCPP16StartTransactionResponse, OCPP16StopTransactionReason, OCPP16StopTransactionResponse, StartTransactionRequest, StopTransactionRequest } from '../../../types/ocpp/1.6/Transaction';
4c2b4904 5import { CurrentType, Voltage } from '../../../types/ChargingStationTemplate';
47e22477 6import { DiagnosticsStatusNotificationRequest, HeartbeatRequest, OCPP16BootNotificationRequest, OCPP16IncomingRequestCommand, OCPP16RequestCommand, StatusNotificationRequest } from '../../../types/ocpp/1.6/Requests';
9ccca265 7import { MeterValueUnit, MeterValuesRequest, OCPP16MeterValue, OCPP16MeterValueMeasurand, OCPP16MeterValuePhase } from '../../../types/ocpp/1.6/MeterValues';
c0560973
JB
8
9import Constants from '../../../utils/Constants';
14763b46 10import { ErrorType } from '../../../types/ocpp/ErrorType';
9ccca265 11import MeasurandPerPhaseSampledValueTemplates from '../../../types/MeasurandPerPhaseSampledValueTemplates';
c0560973
JB
12import MeasurandValues from '../../../types/MeasurandValues';
13import { MessageType } from '../../../types/ocpp/MessageType';
efa43e52 14import { OCPP16BootNotificationResponse } from '../../../types/ocpp/1.6/Responses';
c0560973
JB
15import { OCPP16ChargePointErrorCode } from '../../../types/ocpp/1.6/ChargePointErrorCode';
16import { OCPP16ChargePointStatus } from '../../../types/ocpp/1.6/ChargePointStatus';
47e22477 17import { OCPP16DiagnosticsStatus } from '../../../types/ocpp/1.6/DiagnosticsStatus';
6ed92bc1 18import { OCPP16ServiceUtils } from './OCPP16ServiceUtils';
14763b46 19import OCPPError from '../OCPPError';
c0560973 20import OCPPRequestService from '../OCPPRequestService';
a6b3c6c3 21import { RequestCommand } from '../../../types/ocpp/Requests';
c0560973
JB
22import Utils from '../../../utils/Utils';
23import logger from '../../../utils/Logger';
24
25export default class OCPP16RequestService extends OCPPRequestService {
26 public async sendHeartbeat(): Promise<void> {
27 try {
28 const payload: HeartbeatRequest = {};
29 await this.sendMessage(Utils.generateUUID(), payload, MessageType.CALL_MESSAGE, OCPP16RequestCommand.HEARTBEAT);
30 } catch (error) {
31 this.handleRequestError(OCPP16RequestCommand.HEARTBEAT, error);
32 }
33 }
34
fd0c36fa
JB
35 public async sendBootNotification(chargePointModel: string, chargePointVendor: string, chargeBoxSerialNumber?: string, firmwareVersion?: string,
36 chargePointSerialNumber?: string, iccid?: string, imsi?: string, meterSerialNumber?: string, meterType?: string): Promise<OCPP16BootNotificationResponse> {
c0560973
JB
37 try {
38 const payload: OCPP16BootNotificationRequest = {
39 chargePointModel,
40 chargePointVendor,
41 ...!Utils.isUndefined(chargeBoxSerialNumber) && { chargeBoxSerialNumber },
42 ...!Utils.isUndefined(chargePointSerialNumber) && { chargePointSerialNumber },
43 ...!Utils.isUndefined(firmwareVersion) && { firmwareVersion },
44 ...!Utils.isUndefined(iccid) && { iccid },
45 ...!Utils.isUndefined(imsi) && { imsi },
46 ...!Utils.isUndefined(meterSerialNumber) && { meterSerialNumber },
47 ...!Utils.isUndefined(meterType) && { meterType }
48 };
a6b3c6c3 49 return await this.sendMessage(Utils.generateUUID(), payload, MessageType.CALL_MESSAGE, OCPP16RequestCommand.BOOT_NOTIFICATION, true) as OCPP16BootNotificationResponse;
c0560973
JB
50 } catch (error) {
51 this.handleRequestError(OCPP16RequestCommand.BOOT_NOTIFICATION, error);
52 }
53 }
54
035742f7
JB
55 public async sendStatusNotification(connectorId: number, status: OCPP16ChargePointStatus,
56 errorCode: OCPP16ChargePointErrorCode = OCPP16ChargePointErrorCode.NO_ERROR): Promise<void> {
c0560973
JB
57 try {
58 const payload: StatusNotificationRequest = {
59 connectorId,
60 errorCode,
61 status,
62 };
63 await this.sendMessage(Utils.generateUUID(), payload, MessageType.CALL_MESSAGE, OCPP16RequestCommand.STATUS_NOTIFICATION);
64 } catch (error) {
65 this.handleRequestError(OCPP16RequestCommand.STATUS_NOTIFICATION, error);
66 }
67 }
68
163547b1 69 public async sendAuthorize(connectorId: number, idTag?: string): Promise<OCPP16AuthorizeResponse> {
c0560973
JB
70 try {
71 const payload: AuthorizeRequest = {
bb3343f9 72 ...!Utils.isUndefined(idTag) ? { idTag } : { idTag: Constants.TRANSACTION_DEFAULT_IDTAG },
c0560973 73 };
163547b1 74 this.chargingStation.getConnector(connectorId).authorizeIdTag = idTag;
c0560973
JB
75 return await this.sendMessage(Utils.generateUUID(), payload, MessageType.CALL_MESSAGE, OCPP16RequestCommand.AUTHORIZE) as OCPP16AuthorizeResponse;
76 } catch (error) {
77 this.handleRequestError(OCPP16RequestCommand.AUTHORIZE, error);
78 }
79 }
80
81 public async sendStartTransaction(connectorId: number, idTag?: string): Promise<OCPP16StartTransactionResponse> {
82 try {
83 const payload: StartTransactionRequest = {
84 connectorId,
bb3343f9 85 ...!Utils.isUndefined(idTag) ? { idTag } : { idTag: Constants.TRANSACTION_DEFAULT_IDTAG },
6ed92bc1 86 meterStart: this.chargingStation.getEnergyActiveImportRegisterByConnectorId(connectorId),
c0560973
JB
87 timestamp: new Date().toISOString(),
88 };
6ed92bc1 89 return await this.sendMessage(Utils.generateUUID(), payload, MessageType.CALL_MESSAGE, OCPP16RequestCommand.START_TRANSACTION) as OCPP16StartTransactionResponse;
c0560973
JB
90 } catch (error) {
91 this.handleRequestError(OCPP16RequestCommand.START_TRANSACTION, error);
92 }
93 }
94
035742f7
JB
95 public async sendStopTransaction(transactionId: number, meterStop: number, idTag?: string,
96 reason: OCPP16StopTransactionReason = OCPP16StopTransactionReason.NONE): Promise<OCPP16StopTransactionResponse> {
c0560973 97 try {
326f6e38
JB
98 let connectorId: number;
99 for (const connector in this.chargingStation.connectors) {
100 if (Utils.convertToInt(connector) > 0 && this.chargingStation.getConnector(Utils.convertToInt(connector))?.transactionId === transactionId) {
101 connectorId = Utils.convertToInt(connector);
163547b1 102 break;
326f6e38
JB
103 }
104 }
fd0c36fa
JB
105 const transactionEndMeterValue = OCPP16ServiceUtils.buildTransactionEndMeterValue(this.chargingStation, connectorId, meterStop);
106 // FIXME: should be a callback, each OCPP commands implementation must do only one job
6ed92bc1 107 (this.chargingStation.getBeginEndMeterValues() && !this.chargingStation.getOutOfOrderEndMeterValues())
fd0c36fa
JB
108 && await this.sendTransactionEndMeterValues(connectorId, transactionId, transactionEndMeterValue);
109 const payload: StopTransactionRequest = {
110 transactionId,
111 ...!Utils.isUndefined(idTag) && { idTag },
112 meterStop,
113 timestamp: new Date().toISOString(),
114 ...reason && { reason },
115 ...this.chargingStation.getTransactionDataMeterValues() && { transactionData: OCPP16ServiceUtils.buildTransactionDataMeterValues(this.chargingStation.getConnector(connectorId).transactionBeginMeterValue, transactionEndMeterValue) },
116 };
c0560973
JB
117 return await this.sendMessage(Utils.generateUUID(), payload, MessageType.CALL_MESSAGE, OCPP16RequestCommand.STOP_TRANSACTION) as OCPP16StartTransactionResponse;
118 } catch (error) {
119 this.handleRequestError(OCPP16RequestCommand.STOP_TRANSACTION, error);
120 }
121 }
122
aef1b33a 123 public async sendMeterValues(connectorId: number, transactionId: number, interval: number, debug = false): Promise<void> {
c0560973 124 try {
fd0c36fa 125 const meterValue: OCPP16MeterValue = {
c0560973
JB
126 timestamp: new Date().toISOString(),
127 sampledValue: [],
128 };
aef1b33a 129 const connector = this.chargingStation.getConnector(connectorId);
9ccca265 130 // SoC measurand
aef1b33a 131 const socSampledValueTemplate = this.chargingStation.getSampledValueTemplate(connectorId, OCPP16MeterValueMeasurand.STATE_OF_CHARGE);
9ccca265 132 if (socSampledValueTemplate) {
561d966b
JB
133 const socSampledValueTemplateValue = socSampledValueTemplate.value
134 ? Utils.getRandomFloatFluctuatedRounded(parseInt(socSampledValueTemplate.value), socSampledValueTemplate.fluctuationPercent ?? Constants.DEFAULT_FLUCTUATION_PERCENT)
72740232 135 : Utils.getRandomInteger(100);
561d966b 136 meterValue.sampledValue.push(OCPP16ServiceUtils.buildSampledValue(socSampledValueTemplate, socSampledValueTemplateValue));
9ccca265
JB
137 const sampledValuesIndex = meterValue.sampledValue.length - 1;
138 if (Utils.convertToInt(meterValue.sampledValue[sampledValuesIndex].value) > 100 || debug) {
aef1b33a 139 logger.error(`${this.chargingStation.logPrefix()} MeterValues measurand ${meterValue.sampledValue[sampledValuesIndex].measurand ?? OCPP16MeterValueMeasurand.ENERGY_ACTIVE_IMPORT_REGISTER}: connectorId ${connectorId}, transaction ${connector.transactionId}, value: ${meterValue.sampledValue[sampledValuesIndex].value}/100`);
9ccca265
JB
140 }
141 }
142 // Voltage measurand
aef1b33a 143 const voltageSampledValueTemplate = this.chargingStation.getSampledValueTemplate(connectorId, OCPP16MeterValueMeasurand.VOLTAGE);
9ccca265 144 if (voltageSampledValueTemplate) {
aef1b33a 145 const voltageSampledValueTemplateValue = voltageSampledValueTemplate.value ? parseInt(voltageSampledValueTemplate.value) : this.chargingStation.getVoltageOut();
9ccca265
JB
146 const fluctuationPercent = voltageSampledValueTemplate.fluctuationPercent ?? Constants.DEFAULT_FLUCTUATION_PERCENT;
147 const voltageMeasurandValue = Utils.getRandomFloatFluctuatedRounded(voltageSampledValueTemplateValue, fluctuationPercent);
aef1b33a 148 if (this.chargingStation.getNumberOfPhases() !== 3 || (this.chargingStation.getNumberOfPhases() === 3 && this.chargingStation.getMainVoltageMeterValues())) {
9ccca265
JB
149 meterValue.sampledValue.push(OCPP16ServiceUtils.buildSampledValue(voltageSampledValueTemplate, voltageMeasurandValue));
150 }
aef1b33a 151 for (let phase = 1; this.chargingStation.getNumberOfPhases() === 3 && phase <= this.chargingStation.getNumberOfPhases(); phase++) {
9ccca265 152 const phaseLineToNeutralValue = `L${phase}-N`;
aef1b33a 153 const voltagePhaseLineToNeutralSampledValueTemplate = this.chargingStation.getSampledValueTemplate(connectorId, OCPP16MeterValueMeasurand.VOLTAGE,
9ccca265
JB
154 phaseLineToNeutralValue as OCPP16MeterValuePhase);
155 let voltagePhaseLineToNeutralMeasurandValue: number;
156 if (voltagePhaseLineToNeutralSampledValueTemplate) {
aef1b33a 157 const voltagePhaseLineToNeutralSampledValueTemplateValue = voltagePhaseLineToNeutralSampledValueTemplate.value ? parseInt(voltagePhaseLineToNeutralSampledValueTemplate.value) : this.chargingStation.getVoltageOut();
9ccca265
JB
158 const fluctuationPhaseToNeutralPercent = voltagePhaseLineToNeutralSampledValueTemplate.fluctuationPercent ?? Constants.DEFAULT_FLUCTUATION_PERCENT;
159 voltagePhaseLineToNeutralMeasurandValue = Utils.getRandomFloatFluctuatedRounded(voltagePhaseLineToNeutralSampledValueTemplateValue, fluctuationPhaseToNeutralPercent);
c0560973 160 }
9ccca265
JB
161 meterValue.sampledValue.push(OCPP16ServiceUtils.buildSampledValue(voltagePhaseLineToNeutralSampledValueTemplate ?? voltageSampledValueTemplate,
162 voltagePhaseLineToNeutralMeasurandValue ?? voltageMeasurandValue, null, phaseLineToNeutralValue as OCPP16MeterValuePhase));
aef1b33a
JB
163 if (this.chargingStation.getPhaseLineToLineVoltageMeterValues()) {
164 const phaseLineToLineValue = `L${phase}-L${(phase + 1) % this.chargingStation.getNumberOfPhases() !== 0 ? (phase + 1) % this.chargingStation.getNumberOfPhases() : this.chargingStation.getNumberOfPhases()}`;
165 const voltagePhaseLineToLineSampledValueTemplate = this.chargingStation.getSampledValueTemplate(connectorId, OCPP16MeterValueMeasurand.VOLTAGE, phaseLineToLineValue as OCPP16MeterValuePhase);
9bd87386
JB
166 let voltagePhaseLineToLineMeasurandValue: number;
167 if (voltagePhaseLineToLineSampledValueTemplate) {
4c2b4904 168 const voltagePhaseLineToLineSampledValueTemplateValue = voltagePhaseLineToLineSampledValueTemplate.value ? parseInt(voltagePhaseLineToLineSampledValueTemplate.value) : Voltage.VOLTAGE_400;
9bd87386
JB
169 const fluctuationPhaseLineToLinePercent = voltagePhaseLineToLineSampledValueTemplate.fluctuationPercent ?? Constants.DEFAULT_FLUCTUATION_PERCENT;
170 voltagePhaseLineToLineMeasurandValue = Utils.getRandomFloatFluctuatedRounded(voltagePhaseLineToLineSampledValueTemplateValue, fluctuationPhaseLineToLinePercent);
171 }
4c2b4904 172 const defaultVoltagePhaseLineToLineMeasurandValue = Utils.getRandomFloatFluctuatedRounded(Voltage.VOLTAGE_400, fluctuationPercent);
9bd87386
JB
173 meterValue.sampledValue.push(OCPP16ServiceUtils.buildSampledValue(voltagePhaseLineToLineSampledValueTemplate ?? voltageSampledValueTemplate,
174 voltagePhaseLineToLineMeasurandValue ?? defaultVoltagePhaseLineToLineMeasurandValue, null, phaseLineToLineValue as OCPP16MeterValuePhase));
c0560973 175 }
9ccca265
JB
176 }
177 }
178 // Power.Active.Import measurand
aef1b33a 179 const powerSampledValueTemplate = this.chargingStation.getSampledValueTemplate(connectorId, OCPP16MeterValueMeasurand.POWER_ACTIVE_IMPORT);
9ccca265 180 let powerPerPhaseSampledValueTemplates: MeasurandPerPhaseSampledValueTemplates = {};
aef1b33a 181 if (this.chargingStation.getNumberOfPhases() === 3) {
9ccca265 182 powerPerPhaseSampledValueTemplates = {
aef1b33a
JB
183 L1: this.chargingStation.getSampledValueTemplate(connectorId, OCPP16MeterValueMeasurand.POWER_ACTIVE_IMPORT, OCPP16MeterValuePhase.L1_N),
184 L2: this.chargingStation.getSampledValueTemplate(connectorId, OCPP16MeterValueMeasurand.POWER_ACTIVE_IMPORT, OCPP16MeterValuePhase.L2_N),
185 L3: this.chargingStation.getSampledValueTemplate(connectorId, OCPP16MeterValueMeasurand.POWER_ACTIVE_IMPORT, OCPP16MeterValuePhase.L3_N),
9ccca265
JB
186 };
187 }
188 if (powerSampledValueTemplate) {
aef1b33a
JB
189 OCPP16ServiceUtils.checkMeasurandPowerDivider(this.chargingStation, powerSampledValueTemplate.measurand);
190 const errMsg = `${this.chargingStation.logPrefix()} MeterValues measurand ${powerSampledValueTemplate.measurand ?? OCPP16MeterValueMeasurand.ENERGY_ACTIVE_IMPORT_REGISTER}: Unknown ${this.chargingStation.getCurrentOutType()} currentOutType in template file ${this.chargingStation.stationTemplateFile}, cannot calculate ${powerSampledValueTemplate.measurand ?? OCPP16MeterValueMeasurand.ENERGY_ACTIVE_IMPORT_REGISTER} measurand value`;
9ccca265
JB
191 const powerMeasurandValues = {} as MeasurandValues;
192 const unitDivider = powerSampledValueTemplate?.unit === MeterValueUnit.KILO_WATT ? 1000 : 1;
aef1b33a
JB
193 const maxPower = Math.round(this.chargingStation.stationInfo.maxPower / this.chargingStation.stationInfo.powerDivider);
194 const maxPowerPerPhase = Math.round((this.chargingStation.stationInfo.maxPower / this.chargingStation.stationInfo.powerDivider) / this.chargingStation.getNumberOfPhases());
195 switch (this.chargingStation.getCurrentOutType()) {
4c2b4904 196 case CurrentType.AC:
aef1b33a 197 if (this.chargingStation.getNumberOfPhases() === 3) {
9ccca265 198 const defaultFluctuatedPowerPerPhase = powerSampledValueTemplate.value
aef1b33a 199 && Utils.getRandomFloatFluctuatedRounded(parseInt(powerSampledValueTemplate.value) / this.chargingStation.getNumberOfPhases(), powerSampledValueTemplate.fluctuationPercent ?? Constants.DEFAULT_FLUCTUATION_PERCENT);
9ccca265
JB
200 const phase1FluctuatedValue = powerPerPhaseSampledValueTemplates?.L1?.value
201 && Utils.getRandomFloatFluctuatedRounded(parseInt(powerPerPhaseSampledValueTemplates.L1.value), powerPerPhaseSampledValueTemplates.L1.fluctuationPercent ?? Constants.DEFAULT_FLUCTUATION_PERCENT);
202 const phase2FluctuatedValue = powerPerPhaseSampledValueTemplates?.L2?.value
203 && Utils.getRandomFloatFluctuatedRounded(parseInt(powerPerPhaseSampledValueTemplates.L2.value), powerPerPhaseSampledValueTemplates.L2.fluctuationPercent ?? Constants.DEFAULT_FLUCTUATION_PERCENT);
204 const phase3FluctuatedValue = powerPerPhaseSampledValueTemplates?.L3?.value
205 && Utils.getRandomFloatFluctuatedRounded(parseInt(powerPerPhaseSampledValueTemplates.L3.value), powerPerPhaseSampledValueTemplates.L3.fluctuationPercent ?? Constants.DEFAULT_FLUCTUATION_PERCENT);
206 powerMeasurandValues.L1 = (phase1FluctuatedValue ?? defaultFluctuatedPowerPerPhase) ?? Utils.getRandomFloatRounded(maxPowerPerPhase / unitDivider);
207 powerMeasurandValues.L2 = (phase2FluctuatedValue ?? defaultFluctuatedPowerPerPhase) ?? Utils.getRandomFloatRounded(maxPowerPerPhase / unitDivider);
208 powerMeasurandValues.L3 = (phase3FluctuatedValue ?? defaultFluctuatedPowerPerPhase) ?? Utils.getRandomFloatRounded(maxPowerPerPhase / unitDivider);
c0560973 209 } else {
9ccca265
JB
210 powerMeasurandValues.L1 = powerSampledValueTemplate.value
211 ? Utils.getRandomFloatFluctuatedRounded(parseInt(powerSampledValueTemplate.value), powerSampledValueTemplate.fluctuationPercent ?? Constants.DEFAULT_FLUCTUATION_PERCENT)
212 : Utils.getRandomFloatRounded(maxPower / unitDivider);
213 powerMeasurandValues.L2 = 0;
214 powerMeasurandValues.L3 = 0;
c0560973 215 }
9ccca265
JB
216 powerMeasurandValues.allPhases = Utils.roundTo(powerMeasurandValues.L1 + powerMeasurandValues.L2 + powerMeasurandValues.L3, 2);
217 break;
4c2b4904 218 case CurrentType.DC:
9ccca265
JB
219 powerMeasurandValues.allPhases = powerSampledValueTemplate.value
220 ? Utils.getRandomFloatFluctuatedRounded(parseInt(powerSampledValueTemplate.value), powerSampledValueTemplate.fluctuationPercent ?? Constants.DEFAULT_FLUCTUATION_PERCENT)
221 : Utils.getRandomFloatRounded(maxPower / unitDivider);
222 break;
223 default:
224 logger.error(errMsg);
a6b3c6c3 225 throw new OCPPError(ErrorType.INTERNAL_ERROR, errMsg, RequestCommand.METER_VALUES);
9ccca265
JB
226 }
227 meterValue.sampledValue.push(OCPP16ServiceUtils.buildSampledValue(powerSampledValueTemplate, powerMeasurandValues.allPhases));
228 const sampledValuesIndex = meterValue.sampledValue.length - 1;
229 const maxPowerRounded = Utils.roundTo(maxPower / unitDivider, 2);
230 if (Utils.convertToFloat(meterValue.sampledValue[sampledValuesIndex].value) > maxPowerRounded || debug) {
aef1b33a 231 logger.error(`${this.chargingStation.logPrefix()} MeterValues measurand ${meterValue.sampledValue[sampledValuesIndex].measurand ?? OCPP16MeterValueMeasurand.ENERGY_ACTIVE_IMPORT_REGISTER}: connectorId ${connectorId}, transaction ${connector.transactionId}, value: ${meterValue.sampledValue[sampledValuesIndex].value}/${maxPowerRounded}`);
9ccca265 232 }
aef1b33a 233 for (let phase = 1; this.chargingStation.getNumberOfPhases() === 3 && phase <= this.chargingStation.getNumberOfPhases(); phase++) {
9ccca265
JB
234 const phaseValue = `L${phase}-N`;
235 meterValue.sampledValue.push(OCPP16ServiceUtils.buildSampledValue(powerPerPhaseSampledValueTemplates[`L${phase}`] ?? powerSampledValueTemplate, powerMeasurandValues[`L${phase}`], null,
236 phaseValue as OCPP16MeterValuePhase));
237 const sampledValuesPerPhaseIndex = meterValue.sampledValue.length - 1;
238 const maxPowerPerPhaseRounded = Utils.roundTo(maxPowerPerPhase / unitDivider, 2);
239 if (Utils.convertToFloat(meterValue.sampledValue[sampledValuesPerPhaseIndex].value) > maxPowerPerPhaseRounded || debug) {
aef1b33a 240 logger.error(`${this.chargingStation.logPrefix()} MeterValues measurand ${meterValue.sampledValue[sampledValuesPerPhaseIndex].measurand ?? OCPP16MeterValueMeasurand.ENERGY_ACTIVE_IMPORT_REGISTER}: phase ${meterValue.sampledValue[sampledValuesPerPhaseIndex].phase}, connectorId ${connectorId}, transaction ${connector.transactionId}, value: ${meterValue.sampledValue[sampledValuesPerPhaseIndex].value}/${maxPowerPerPhaseRounded}`);
c0560973 241 }
9ccca265
JB
242 }
243 }
244 // Current.Import measurand
aef1b33a 245 const currentSampledValueTemplate = this.chargingStation.getSampledValueTemplate(connectorId, OCPP16MeterValueMeasurand.CURRENT_IMPORT);
9ccca265 246 let currentPerPhaseSampledValueTemplates: MeasurandPerPhaseSampledValueTemplates = {};
aef1b33a 247 if (this.chargingStation.getNumberOfPhases() === 3) {
9ccca265 248 currentPerPhaseSampledValueTemplates = {
aef1b33a
JB
249 L1: this.chargingStation.getSampledValueTemplate(connectorId, OCPP16MeterValueMeasurand.CURRENT_IMPORT, OCPP16MeterValuePhase.L1),
250 L2: this.chargingStation.getSampledValueTemplate(connectorId, OCPP16MeterValueMeasurand.CURRENT_IMPORT, OCPP16MeterValuePhase.L2),
251 L3: this.chargingStation.getSampledValueTemplate(connectorId, OCPP16MeterValueMeasurand.CURRENT_IMPORT, OCPP16MeterValuePhase.L3),
9ccca265
JB
252 };
253 }
254 if (currentSampledValueTemplate) {
aef1b33a
JB
255 OCPP16ServiceUtils.checkMeasurandPowerDivider(this.chargingStation, currentSampledValueTemplate.measurand);
256 const errMsg = `${this.chargingStation.logPrefix()} MeterValues measurand ${currentSampledValueTemplate.measurand ?? OCPP16MeterValueMeasurand.ENERGY_ACTIVE_IMPORT_REGISTER}: Unknown ${this.chargingStation.getCurrentOutType()} currentOutType in template file ${this.chargingStation.stationTemplateFile}, cannot calculate ${currentSampledValueTemplate.measurand ?? OCPP16MeterValueMeasurand.ENERGY_ACTIVE_IMPORT_REGISTER} measurand value`;
9ccca265
JB
257 const currentMeasurandValues: MeasurandValues = {} as MeasurandValues;
258 let maxAmperage: number;
aef1b33a 259 switch (this.chargingStation.getCurrentOutType()) {
4c2b4904 260 case CurrentType.AC:
aef1b33a
JB
261 maxAmperage = ACElectricUtils.amperagePerPhaseFromPower(this.chargingStation.getNumberOfPhases(), this.chargingStation.stationInfo.maxPower / this.chargingStation.stationInfo.powerDivider, this.chargingStation.getVoltageOut());
262 if (this.chargingStation.getNumberOfPhases() === 3) {
9ccca265
JB
263 const defaultFluctuatedAmperagePerPhase = currentSampledValueTemplate.value
264 && Utils.getRandomFloatFluctuatedRounded(parseInt(currentSampledValueTemplate.value), currentSampledValueTemplate.fluctuationPercent ?? Constants.DEFAULT_FLUCTUATION_PERCENT);
265 const phase1FluctuatedValue = currentPerPhaseSampledValueTemplates?.L1?.value
266 && Utils.getRandomFloatFluctuatedRounded(parseInt(currentPerPhaseSampledValueTemplates.L1.value), currentPerPhaseSampledValueTemplates.L1.fluctuationPercent ?? Constants.DEFAULT_FLUCTUATION_PERCENT);
267 const phase2FluctuatedValue = currentPerPhaseSampledValueTemplates?.L2?.value
268 && Utils.getRandomFloatFluctuatedRounded(parseInt(currentPerPhaseSampledValueTemplates.L2.value), currentPerPhaseSampledValueTemplates.L2.fluctuationPercent ?? Constants.DEFAULT_FLUCTUATION_PERCENT);
269 const phase3FluctuatedValue = currentPerPhaseSampledValueTemplates?.L3?.value
270 && Utils.getRandomFloatFluctuatedRounded(parseInt(currentPerPhaseSampledValueTemplates.L3.value), currentPerPhaseSampledValueTemplates.L3.fluctuationPercent ?? Constants.DEFAULT_FLUCTUATION_PERCENT);
271 currentMeasurandValues.L1 = (phase1FluctuatedValue ?? defaultFluctuatedAmperagePerPhase) ?? Utils.getRandomFloatRounded(maxAmperage);
272 currentMeasurandValues.L2 = (phase2FluctuatedValue ?? defaultFluctuatedAmperagePerPhase) ?? Utils.getRandomFloatRounded(maxAmperage);
273 currentMeasurandValues.L3 = (phase3FluctuatedValue ?? defaultFluctuatedAmperagePerPhase) ?? Utils.getRandomFloatRounded(maxAmperage);
274 } else {
275 currentMeasurandValues.L1 = currentSampledValueTemplate.value
276 ? Utils.getRandomFloatFluctuatedRounded(parseInt(currentSampledValueTemplate.value), currentSampledValueTemplate.fluctuationPercent ?? Constants.DEFAULT_FLUCTUATION_PERCENT)
277 : Utils.getRandomFloatRounded(maxAmperage);
278 currentMeasurandValues.L2 = 0;
279 currentMeasurandValues.L3 = 0;
280 }
aef1b33a 281 currentMeasurandValues.allPhases = Utils.roundTo((currentMeasurandValues.L1 + currentMeasurandValues.L2 + currentMeasurandValues.L3) / this.chargingStation.getNumberOfPhases(), 2);
9ccca265 282 break;
4c2b4904 283 case CurrentType.DC:
aef1b33a 284 maxAmperage = DCElectricUtils.amperage(this.chargingStation.stationInfo.maxPower / this.chargingStation.stationInfo.powerDivider, this.chargingStation.getVoltageOut());
9ccca265
JB
285 currentMeasurandValues.allPhases = currentSampledValueTemplate.value
286 ? Utils.getRandomFloatFluctuatedRounded(parseInt(currentSampledValueTemplate.value), currentSampledValueTemplate.fluctuationPercent ?? Constants.DEFAULT_FLUCTUATION_PERCENT)
287 : Utils.getRandomFloatRounded(maxAmperage);
288 break;
289 default:
290 logger.error(errMsg);
a6b3c6c3 291 throw new OCPPError(ErrorType.INTERNAL_ERROR, errMsg, RequestCommand.METER_VALUES);
9ccca265
JB
292 }
293 meterValue.sampledValue.push(OCPP16ServiceUtils.buildSampledValue(currentSampledValueTemplate, currentMeasurandValues.allPhases));
294 const sampledValuesIndex = meterValue.sampledValue.length - 1;
295 if (Utils.convertToFloat(meterValue.sampledValue[sampledValuesIndex].value) > maxAmperage || debug) {
aef1b33a 296 logger.error(`${this.chargingStation.logPrefix()} MeterValues measurand ${meterValue.sampledValue[sampledValuesIndex].measurand ?? OCPP16MeterValueMeasurand.ENERGY_ACTIVE_IMPORT_REGISTER}: connectorId ${connectorId}, transaction ${connector.transactionId}, value: ${meterValue.sampledValue[sampledValuesIndex].value}/${maxAmperage}`);
9ccca265 297 }
aef1b33a 298 for (let phase = 1; this.chargingStation.getNumberOfPhases() === 3 && phase <= this.chargingStation.getNumberOfPhases(); phase++) {
9ccca265
JB
299 const phaseValue = `L${phase}`;
300 meterValue.sampledValue.push(OCPP16ServiceUtils.buildSampledValue(currentPerPhaseSampledValueTemplates[phaseValue] ?? currentSampledValueTemplate,
301 currentMeasurandValues[phaseValue], null, phaseValue as OCPP16MeterValuePhase));
302 const sampledValuesPerPhaseIndex = meterValue.sampledValue.length - 1;
303 if (Utils.convertToFloat(meterValue.sampledValue[sampledValuesPerPhaseIndex].value) > maxAmperage || debug) {
aef1b33a 304 logger.error(`${this.chargingStation.logPrefix()} MeterValues measurand ${meterValue.sampledValue[sampledValuesPerPhaseIndex].measurand ?? OCPP16MeterValueMeasurand.ENERGY_ACTIVE_IMPORT_REGISTER}: phase ${meterValue.sampledValue[sampledValuesPerPhaseIndex].phase}, connectorId ${connectorId}, transaction ${connector.transactionId}, value: ${meterValue.sampledValue[sampledValuesPerPhaseIndex].value}/${maxAmperage}`);
c0560973 305 }
9ccca265
JB
306 }
307 }
308 // Energy.Active.Import.Register measurand (default)
aef1b33a 309 const energySampledValueTemplate = this.chargingStation.getSampledValueTemplate(connectorId);
9ccca265 310 if (energySampledValueTemplate) {
aef1b33a 311 OCPP16ServiceUtils.checkMeasurandPowerDivider(this.chargingStation, energySampledValueTemplate.measurand);
9ccca265
JB
312 const unitDivider = energySampledValueTemplate?.unit === MeterValueUnit.KILO_WATT_HOUR ? 1000 : 1;
313 const energyMeasurandValue = energySampledValueTemplate.value
314 // Cumulate the fluctuated value around the static one
315 ? Utils.getRandomFloatFluctuatedRounded(parseInt(energySampledValueTemplate.value), energySampledValueTemplate.fluctuationPercent ?? Constants.DEFAULT_FLUCTUATION_PERCENT)
72740232 316 : Utils.getRandomInteger(this.chargingStation.stationInfo.maxPower / (this.chargingStation.stationInfo.powerDivider * 3600000) * interval);
9ccca265
JB
317 // Persist previous value on connector
318 if (connector && !Utils.isNullOrUndefined(connector.energyActiveImportRegisterValue) && connector.energyActiveImportRegisterValue >= 0 &&
319 !Utils.isNullOrUndefined(connector.transactionEnergyActiveImportRegisterValue) && connector.transactionEnergyActiveImportRegisterValue >= 0) {
320 connector.energyActiveImportRegisterValue += energyMeasurandValue;
321 connector.transactionEnergyActiveImportRegisterValue += energyMeasurandValue;
c0560973 322 } else {
9ccca265
JB
323 connector.energyActiveImportRegisterValue = 0;
324 connector.transactionEnergyActiveImportRegisterValue = 0;
325 }
326 meterValue.sampledValue.push(OCPP16ServiceUtils.buildSampledValue(energySampledValueTemplate,
aef1b33a 327 Utils.roundTo(this.chargingStation.getEnergyActiveImportRegisterByTransactionId(transactionId) / unitDivider, 4)));
9ccca265 328 const sampledValuesIndex = meterValue.sampledValue.length - 1;
aef1b33a 329 const maxEnergy = Math.round(this.chargingStation.stationInfo.maxPower * 3600 / (this.chargingStation.stationInfo.powerDivider * interval));
9ccca265
JB
330 const maxEnergyRounded = Utils.roundTo(maxEnergy / unitDivider, 4);
331 if (Utils.convertToFloat(meterValue.sampledValue[sampledValuesIndex].value) > maxEnergyRounded || debug) {
aef1b33a 332 logger.error(`${this.chargingStation.logPrefix()} MeterValues measurand ${meterValue.sampledValue[sampledValuesIndex].measurand ?? OCPP16MeterValueMeasurand.ENERGY_ACTIVE_IMPORT_REGISTER}: connectorId ${connectorId}, transaction ${connector.transactionId}, value: ${meterValue.sampledValue[sampledValuesIndex].value}/${maxEnergyRounded}`);
c0560973
JB
333 }
334 }
335 const payload: MeterValuesRequest = {
336 connectorId,
337 transactionId,
b02ab215 338 meterValue: [meterValue],
c0560973 339 };
aef1b33a 340 await this.sendMessage(Utils.generateUUID(), payload, MessageType.CALL_MESSAGE, OCPP16RequestCommand.METER_VALUES);
c0560973 341 } catch (error) {
aef1b33a 342 this.handleRequestError(OCPP16RequestCommand.METER_VALUES, error);
c0560973
JB
343 }
344 }
345
fd0c36fa 346 public async sendTransactionBeginMeterValues(connectorId: number, transactionId: number, beginMeterValue: OCPP16MeterValue): Promise<void> {
290d006c
JB
347 try {
348 const payload: MeterValuesRequest = {
349 connectorId,
350 transactionId,
b02ab215 351 meterValue: [beginMeterValue],
290d006c
JB
352 };
353 await this.sendMessage(Utils.generateUUID(), payload, MessageType.CALL_MESSAGE, OCPP16RequestCommand.METER_VALUES);
354 } catch (error) {
355 this.handleRequestError(OCPP16RequestCommand.METER_VALUES, error);
356 }
326f6e38
JB
357 }
358
fd0c36fa 359 public async sendTransactionEndMeterValues(connectorId: number, transactionId: number, endMeterValue: OCPP16MeterValue): Promise<void> {
290d006c
JB
360 try {
361 const payload: MeterValuesRequest = {
362 connectorId,
363 transactionId,
b02ab215 364 meterValue: [endMeterValue],
290d006c
JB
365 };
366 await this.sendMessage(Utils.generateUUID(), payload, MessageType.CALL_MESSAGE, OCPP16RequestCommand.METER_VALUES);
367 } catch (error) {
368 this.handleRequestError(OCPP16RequestCommand.METER_VALUES, error);
369 }
326f6e38 370 }
6ed92bc1 371
47e22477 372 public async sendDiagnosticsStatusNotification(diagnosticsStatus: OCPP16DiagnosticsStatus): Promise<void> {
290d006c
JB
373 try {
374 const payload: DiagnosticsStatusNotificationRequest = {
375 status: diagnosticsStatus
376 };
377 await this.sendMessage(Utils.generateUUID(), payload, MessageType.CALL_MESSAGE, OCPP16RequestCommand.DIAGNOSTICS_STATUS_NOTIFICATION);
378 } catch (error) {
379 this.handleRequestError(OCPP16RequestCommand.METER_VALUES, error);
380 }
47e22477
JB
381 }
382
6ed92bc1 383 public async sendError(messageId: string, error: OCPPError, commandName: OCPP16RequestCommand | OCPP16IncomingRequestCommand): Promise<unknown> {
290d006c
JB
384 try {
385 // Send error
2891f761 386 return await this.sendMessage(messageId, error, MessageType.CALL_ERROR_MESSAGE, commandName);
290d006c
JB
387 } catch (err) {
388 this.handleRequestError(commandName as OCPP16RequestCommand, err);
389 }
6ed92bc1 390 }
c0560973 391}