cec: put the message processing code from WaitForAck() in ParseMessage(). fixes missi...
[deb_libcec.git] / src / lib / CECProcessor.cpp
CommitLineData
abbca718
LOK
1/*
2 * This file is part of the libCEC(R) library.
3 *
4 * libCEC(R) is Copyright (C) 2011 Pulse-Eight Limited. All rights reserved.
5 * libCEC(R) is an original work, containing original code.
6 *
7 * libCEC(R) is a trademark of Pulse-Eight Limited.
8 *
9 * This program is dual-licensed; you can redistribute it and/or modify
10 * it under the terms of the GNU General Public License as published by
11 * the Free Software Foundation; either version 2 of the License, or
12 * (at your option) any later version.
13 *
14 * This program is distributed in the hope that it will be useful,
15 * but WITHOUT ANY WARRANTY; without even the implied warranty of
16 * MERCHANTABILITY or FITNESS FOR A PARTICULAR PURPOSE. See the
17 * GNU General Public License for more details.
18 *
19 * You should have received a copy of the GNU General Public License
20 * along with this program; if not, write to the Free Software
21 * Foundation, Inc., 59 Temple Place - Suite 330, Boston, MA 02111-1307, USA.
22 *
23 *
24 * Alternatively, you can license this library under a commercial license,
25 * please contact Pulse-Eight Licensing for more information.
26 *
27 * For more information contact:
28 * Pulse-Eight Licensing <license@pulse-eight.com>
29 * http://www.pulse-eight.com/
30 * http://www.pulse-eight.net/
31 */
32
2abe74eb 33#include "CECProcessor.h"
abbca718 34
2abe74eb
LOK
35#include "AdapterCommunication.h"
36#include "LibCEC.h"
abbca718 37#include "util/StdString.h"
b9187cc6 38#include "platform/timeutils.h"
abbca718
LOK
39
40using namespace CEC;
41using namespace std;
42
2b4d8297 43CCECProcessor::CCECProcessor(CLibCEC *controller, CAdapterCommunication *serComm, const char *strDeviceName, cec_logical_address iLogicalAddress /* = CECDEVICE_PLAYBACKDEVICE1 */, uint16_t iPhysicalAddress /* = CEC_DEFAULT_PHYSICAL_ADDRESS*/) :
df7339c6
LOK
44 m_physicaladdress(iPhysicalAddress),
45 m_iLogicalAddress(iLogicalAddress),
2abe74eb
LOK
46 m_strDeviceName(strDeviceName),
47 m_communication(serComm),
48 m_controller(controller)
abbca718 49{
5f150ee2
LOK
50 for (uint8_t iPtr = 0; iPtr < 16; iPtr++)
51 m_vendorIds[iPtr] = CEC_VENDOR_UNKNOWN;
52 for (uint8_t iPtr = 0; iPtr < 16; iPtr++)
53 m_vendorClasses[iPtr] = (uint8_t) 0;
abbca718
LOK
54}
55
2abe74eb 56CCECProcessor::~CCECProcessor(void)
abbca718 57{
2abe74eb
LOK
58 StopThread();
59 m_communication = NULL;
60 m_controller = NULL;
abbca718
LOK
61}
62
2abe74eb 63bool CCECProcessor::Start(void)
abbca718 64{
2abe74eb 65 if (!m_communication || !m_communication->IsOpen())
13fd6a66
LOK
66 {
67 m_controller->AddLog(CEC_LOG_ERROR, "connection is closed");
a8f0bd18 68 return false;
13fd6a66 69 }
abbca718 70
a8f0bd18 71 if (!SetLogicalAddress(m_iLogicalAddress))
abbca718 72 {
2abe74eb 73 m_controller->AddLog(CEC_LOG_ERROR, "could not set the logical address");
a8f0bd18 74 return false;
abbca718
LOK
75 }
76
60fa4578 77 if (CreateThread())
a8f0bd18 78 return true;
a8f0bd18 79 else
2abe74eb 80 m_controller->AddLog(CEC_LOG_ERROR, "could not create a processor thread");
abbca718 81
a8f0bd18 82 return false;
abbca718
LOK
83}
84
2abe74eb 85void *CCECProcessor::Process(void)
f99bc831 86{
2abe74eb 87 m_controller->AddLog(CEC_LOG_DEBUG, "processor thread started");
abbca718 88
9dee1670
LOK
89 cec_command command;
90 cec_adapter_message msg;
91
13fd6a66 92 while (!IsStopped())
abbca718 93 {
60fa4578 94 bool bParseFrame(false);
78e8010a
LOK
95 bool bError(false);
96 bool bTransmitSucceeded(false);
9dee1670 97 command.clear();
76321de4
LOK
98 msg.clear();
99
60fa4578
LOK
100 {
101 CLockObject lock(&m_mutex);
76321de4 102 if (m_communication->IsOpen() && m_communication->Read(msg, 50))
78e8010a 103 ParseMessage(msg, &bError, &bTransmitSucceeded, &bParseFrame);
76321de4 104
78e8010a 105 bParseFrame &= !IsStopped();
76321de4 106 if (bParseFrame)
9dee1670 107 command = m_currentframe;
60fa4578
LOK
108 }
109
13fd6a66 110 if (bParseFrame)
9dee1670 111 ParseCommand(command);
abbca718 112
13fd6a66
LOK
113 m_controller->CheckKeypressTimeout();
114
115 if (!IsStopped())
d5bffd3c 116 Sleep(5);
abbca718
LOK
117 }
118
60fa4578 119 return NULL;
abbca718
LOK
120}
121
2abe74eb 122bool CCECProcessor::PowerOnDevices(cec_logical_address address /* = CECDEVICE_TV */)
abbca718 123{
60fa4578 124 if (!IsRunning())
f99bc831
LOK
125 return false;
126
abbca718 127 CStdString strLog;
88f45c9b 128 strLog.Format("<< powering on device with logical address %d", (int8_t)address);
2abe74eb 129 m_controller->AddLog(CEC_LOG_DEBUG, strLog.c_str());
25701fa6 130
06a1f7ce
LOK
131 cec_command command;
132 cec_command::format(command, m_iLogicalAddress, address, CEC_OPCODE_IMAGE_VIEW_ON);
133
134 return Transmit(command);
abbca718
LOK
135}
136
2abe74eb 137bool CCECProcessor::StandbyDevices(cec_logical_address address /* = CECDEVICE_BROADCAST */)
abbca718 138{
60fa4578 139 if (!IsRunning())
f99bc831
LOK
140 return false;
141
abbca718 142 CStdString strLog;
88f45c9b 143 strLog.Format("<< putting device with logical address %d in standby mode", (int8_t)address);
2abe74eb 144 m_controller->AddLog(CEC_LOG_DEBUG, strLog.c_str());
25701fa6 145
06a1f7ce
LOK
146 cec_command command;
147 cec_command::format(command, m_iLogicalAddress, address, CEC_OPCODE_STANDBY);
148
149 return Transmit(command);
abbca718
LOK
150}
151
2abe74eb 152bool CCECProcessor::SetActiveView(void)
abbca718 153{
60fa4578 154 if (!IsRunning())
f99bc831
LOK
155 return false;
156
88f45c9b 157 m_controller->AddLog(CEC_LOG_DEBUG, "<< setting active view");
9dee1670 158
06a1f7ce
LOK
159 cec_command command;
160 cec_command::format(command, m_iLogicalAddress, CECDEVICE_BROADCAST, CEC_OPCODE_ACTIVE_SOURCE);
9dee1670
LOK
161 command.parameters.push_back((m_physicaladdress >> 8) & 0xFF);
162 command.parameters.push_back(m_physicaladdress & 0xFF);
163
164 return Transmit(command);
abbca718
LOK
165}
166
2abe74eb 167bool CCECProcessor::SetInactiveView(void)
abbca718 168{
60fa4578 169 if (!IsRunning())
f99bc831
LOK
170 return false;
171
88f45c9b 172 m_controller->AddLog(CEC_LOG_DEBUG, "<< setting inactive view");
9dee1670 173
06a1f7ce
LOK
174 cec_command command;
175 cec_command::format(command, m_iLogicalAddress, CECDEVICE_BROADCAST, CEC_OPCODE_INACTIVE_SOURCE);
9dee1670
LOK
176 command.parameters.push_back((m_physicaladdress >> 8) & 0xFF);
177 command.parameters.push_back(m_physicaladdress & 0xFF);
178
179 return Transmit(command);
abbca718
LOK
180}
181
9dee1670 182void CCECProcessor::LogOutput(const cec_command &data)
abbca718 183{
2abe74eb 184 CStdString txStr = "transmit ";
9dee1670
LOK
185 txStr.AppendFormat(" %02x", ((uint8_t)data.initiator << 4) + (uint8_t)data.destination);
186 txStr.AppendFormat(" %02x", (uint8_t)data.opcode);
187
06a1f7ce 188 for (uint8_t iPtr = 0; iPtr < data.parameters.size; iPtr++)
9dee1670 189 txStr.AppendFormat(" %02x", data.parameters[iPtr]);
2abe74eb 190 m_controller->AddLog(CEC_LOG_DEBUG, txStr.c_str());
9dee1670 191}
2abe74eb 192
9dee1670
LOK
193bool CCECProcessor::Transmit(const cec_command &data, bool bWaitForAck /* = true */)
194{
195 LogOutput(data);
2abe74eb 196
9dee1670 197 cec_adapter_message output;
25701fa6 198 output.clear();
9dee1670 199 CAdapterCommunication::FormatAdapterMessage(data, output);
2abe74eb
LOK
200
201 return TransmitFormatted(output, bWaitForAck);
abbca718
LOK
202}
203
2abe74eb 204bool CCECProcessor::SetLogicalAddress(cec_logical_address iLogicalAddress)
abbca718 205{
2abe74eb 206 CStdString strLog;
88f45c9b 207 strLog.Format("<< setting logical address to %d", iLogicalAddress);
2abe74eb
LOK
208 m_controller->AddLog(CEC_LOG_NOTICE, strLog.c_str());
209
210 m_iLogicalAddress = iLogicalAddress;
211 return m_communication && m_communication->SetAckMask(0x1 << (uint8_t)m_iLogicalAddress);
abbca718 212}
825ddb96 213
9dee1670 214bool CCECProcessor::TransmitFormatted(const cec_adapter_message &data, bool bWaitForAck /* = true */)
825ddb96 215{
2abe74eb
LOK
216 CLockObject lock(&m_mutex);
217 if (!m_communication || !m_communication->Write(data))
218 return false;
219
050df0f9 220 if (bWaitForAck)
2abe74eb 221 {
050df0f9
LOK
222 uint64_t now = GetTimeMs();
223 uint64_t target = now + 1000;
224 bool bError(false);
225 bool bGotAck(false);
226
227 while (!bGotAck && now < target)
228 {
06a1f7ce 229 bGotAck = WaitForAck(&bError, (uint32_t) (target - now));
050df0f9
LOK
230 now = GetTimeMs();
231
232 if (bError && now < target)
233 {
234 m_controller->AddLog(CEC_LOG_ERROR, "retransmitting previous frame");
235 if (!m_communication->Write(data))
236 return false;
237 }
238 }
2abe74eb
LOK
239 }
240
241 return true;
825ddb96 242}
abbca718 243
2abe74eb 244void CCECProcessor::TransmitAbort(cec_logical_address address, cec_opcode opcode, ECecAbortReason reason /* = CEC_ABORT_REASON_UNRECOGNIZED_OPCODE */)
abbca718 245{
9dee1670
LOK
246 m_controller->AddLog(CEC_LOG_DEBUG, "<< transmitting abort message");
247
06a1f7ce
LOK
248 cec_command command;
249 cec_command::format(command, m_iLogicalAddress, address, CEC_OPCODE_FEATURE_ABORT);
9dee1670
LOK
250 command.parameters.push_back((uint8_t)opcode);
251 command.parameters.push_back((uint8_t)reason);
252
253 Transmit(command);
abbca718
LOK
254}
255
2abe74eb 256void CCECProcessor::ReportCECVersion(cec_logical_address address /* = CECDEVICE_TV */)
abbca718 257{
88f45c9b 258 m_controller->AddLog(CEC_LOG_NOTICE, "<< reporting CEC version as 1.3a");
9dee1670 259
06a1f7ce
LOK
260 cec_command command;
261 cec_command::format(command, m_iLogicalAddress, address, CEC_OPCODE_CEC_VERSION);
9dee1670
LOK
262 command.parameters.push_back(CEC_VERSION_1_3A);
263
264 Transmit(command);
abbca718
LOK
265}
266
2abe74eb 267void CCECProcessor::ReportPowerState(cec_logical_address address /*= CECDEVICE_TV */, bool bOn /* = true */)
abbca718 268{
abbca718 269 if (bOn)
88f45c9b 270 m_controller->AddLog(CEC_LOG_NOTICE, "<< reporting \"On\" power status");
abbca718 271 else
88f45c9b 272 m_controller->AddLog(CEC_LOG_NOTICE, "<< reporting \"Off\" power status");
abbca718 273
06a1f7ce
LOK
274 cec_command command;
275 cec_command::format(command, m_iLogicalAddress, address, CEC_OPCODE_REPORT_POWER_STATUS);
9dee1670
LOK
276 command.parameters.push_back(bOn ? (uint8_t) CEC_POWER_STATUS_ON : (uint8_t) CEC_POWER_STATUS_STANDBY);
277
278 Transmit(command);
abbca718
LOK
279}
280
2abe74eb 281void CCECProcessor::ReportMenuState(cec_logical_address address /* = CECDEVICE_TV */, bool bActive /* = true */)
abbca718 282{
abbca718 283 if (bActive)
88f45c9b 284 m_controller->AddLog(CEC_LOG_NOTICE, "<< reporting menu state as active");
abbca718 285 else
88f45c9b 286 m_controller->AddLog(CEC_LOG_NOTICE, "<< reporting menu state as inactive");
abbca718 287
06a1f7ce
LOK
288 cec_command command;
289 cec_command::format(command, m_iLogicalAddress, address, CEC_OPCODE_MENU_STATUS);
9dee1670
LOK
290 command.parameters.push_back(bActive ? (uint8_t) CEC_MENU_STATE_ACTIVATED : (uint8_t) CEC_MENU_STATE_DEACTIVATED);
291
292 Transmit(command);
abbca718
LOK
293}
294
2abe74eb 295void CCECProcessor::ReportVendorID(cec_logical_address address /* = CECDEVICE_TV */)
abbca718 296{
88f45c9b 297 m_controller->AddLog(CEC_LOG_NOTICE, "<< vendor ID requested, feature abort");
abbca718
LOK
298 TransmitAbort(address, CEC_OPCODE_GIVE_DEVICE_VENDOR_ID);
299}
300
2abe74eb 301void CCECProcessor::ReportOSDName(cec_logical_address address /* = CECDEVICE_TV */)
abbca718 302{
abbca718
LOK
303 const char *osdname = m_strDeviceName.c_str();
304 CStdString strLog;
88f45c9b 305 strLog.Format("<< reporting OSD name as %s", osdname);
2abe74eb 306 m_controller->AddLog(CEC_LOG_NOTICE, strLog.c_str());
abbca718 307
06a1f7ce
LOK
308 cec_command command;
309 cec_command::format(command, m_iLogicalAddress, address, CEC_OPCODE_SET_OSD_NAME);
9dee1670
LOK
310 for (unsigned int iPtr = 0; iPtr < strlen(osdname); iPtr++)
311 command.parameters.push_back(osdname[iPtr]);
abbca718 312
9dee1670 313 Transmit(command);
abbca718
LOK
314}
315
2abe74eb 316void CCECProcessor::ReportPhysicalAddress(void)
abbca718 317{
abbca718 318 CStdString strLog;
88f45c9b 319 strLog.Format("<< reporting physical address as %04x", m_physicaladdress);
2abe74eb 320 m_controller->AddLog(CEC_LOG_NOTICE, strLog.c_str());
9dee1670 321
06a1f7ce
LOK
322 cec_command command;
323 cec_command::format(command, m_iLogicalAddress, CECDEVICE_BROADCAST, CEC_OPCODE_REPORT_PHYSICAL_ADDRESS);
9dee1670
LOK
324 command.parameters.push_back((uint8_t) ((m_physicaladdress >> 8) & 0xFF));
325 command.parameters.push_back((uint8_t) (m_physicaladdress & 0xFF));
4a75b661 326 command.parameters.push_back((uint8_t) (CEC_DEVICE_TYPE_PLAYBACK_DEVICE));
9dee1670
LOK
327
328 Transmit(command);
abbca718
LOK
329}
330
2abe74eb 331void CCECProcessor::BroadcastActiveSource(void)
abbca718 332{
a6d4fc28 333 m_controller->AddLog(CEC_LOG_NOTICE, "<< broadcasting active source");
abbca718 334
06a1f7ce
LOK
335 cec_command command;
336 cec_command::format(command, m_iLogicalAddress, CECDEVICE_BROADCAST, CEC_OPCODE_ACTIVE_SOURCE);
9dee1670
LOK
337 command.parameters.push_back((uint8_t) ((m_physicaladdress >> 8) & 0xFF));
338 command.parameters.push_back((uint8_t) (m_physicaladdress & 0xFF));
339
340 Transmit(command);
abbca718
LOK
341}
342
050df0f9 343bool CCECProcessor::WaitForAck(bool *bError, uint32_t iTimeout /* = 1000 */)
abbca718 344{
78e8010a 345 bool bTransmitSucceeded = false, bEom = false;
050df0f9 346 *bError = false;
abbca718
LOK
347
348 int64_t iNow = GetTimeMs();
25701fa6 349 int64_t iTargetTime = iNow + (uint64_t) iTimeout;
abbca718 350
78e8010a 351 while (!bTransmitSucceeded && !*bError && (iTimeout == 0 || iNow < iTargetTime))
abbca718 352 {
9dee1670 353 cec_adapter_message msg;
25701fa6
LOK
354 msg.clear();
355
06a1f7ce 356 if (!m_communication->Read(msg, iTimeout > 0 ? (int32_t)(iTargetTime - iNow) : 1000))
abbca718 357 {
abbca718 358 iNow = GetTimeMs();
5d38b0b6
LOK
359 continue;
360 }
361
78e8010a 362 ParseMessage(msg, bError, &bTransmitSucceeded, &bEom, false);
5d38b0b6 363 iNow = GetTimeMs();
abbca718
LOK
364 }
365
78e8010a 366 return bTransmitSucceeded && !*bError;
abbca718
LOK
367}
368
78e8010a 369void CCECProcessor::ParseMessage(cec_adapter_message &msg, bool *bError, bool *bTransmitSucceeded, bool *bEom, bool bProcessMessages /* = true */)
abbca718 370{
78e8010a
LOK
371 *bError = false;
372 *bTransmitSucceeded = false;
373 *bEom = false;
60fa4578 374
a6b6469c 375 if (msg.empty())
78e8010a 376 return;
abbca718
LOK
377
378 CStdString logStr;
abbca718 379
a6b6469c 380 switch(msg.message())
abbca718
LOK
381 {
382 case MSGCODE_NOTHING:
2abe74eb 383 m_controller->AddLog(CEC_LOG_DEBUG, "MSGCODE_NOTHING");
abbca718
LOK
384 break;
385 case MSGCODE_TIMEOUT_ERROR:
386 case MSGCODE_HIGH_ERROR:
387 case MSGCODE_LOW_ERROR:
388 {
a6b6469c 389 if (msg.message() == MSGCODE_TIMEOUT_ERROR)
abbca718 390 logStr = "MSGCODE_TIMEOUT";
a6b6469c 391 else if (msg.message() == MSGCODE_HIGH_ERROR)
abbca718
LOK
392 logStr = "MSGCODE_HIGH_ERROR";
393 else
394 logStr = "MSGCODE_LOW_ERROR";
395
a6b6469c
LOK
396 int iLine = (msg.size() >= 3) ? (msg[1] << 8) | (msg[2]) : 0;
397 uint32_t iTime = (msg.size() >= 7) ? (msg[3] << 24) | (msg[4] << 16) | (msg[5] << 8) | (msg[6]) : 0;
abbca718
LOK
398 logStr.AppendFormat(" line:%i", iLine);
399 logStr.AppendFormat(" time:%u", iTime);
2abe74eb 400 m_controller->AddLog(CEC_LOG_WARNING, logStr.c_str());
78e8010a 401 *bError = true;
abbca718
LOK
402 }
403 break;
404 case MSGCODE_FRAME_START:
405 {
78e8010a 406 if (bProcessMessages)
abbca718 407 {
78e8010a
LOK
408 logStr = "MSGCODE_FRAME_START";
409 m_currentframe.clear();
410 if (msg.size() >= 2)
411 {
412 logStr.AppendFormat(" initiator:%u destination:%u ack:%s %s", msg.initiator(), msg.destination(), msg.ack() ? "high" : "low", msg.eom() ? "eom" : "");
413 m_currentframe.initiator = msg.initiator();
414 m_currentframe.destination = msg.destination();
415 m_currentframe.ack = msg.ack();
416 m_currentframe.eom = msg.eom();
417 }
418 m_controller->AddLog(CEC_LOG_DEBUG, logStr.c_str());
419 }
420 else
421 {
422 m_frameBuffer.Push(msg);
abbca718 423 }
abbca718
LOK
424 }
425 break;
426 case MSGCODE_FRAME_DATA:
427 {
78e8010a
LOK
428 if (bProcessMessages)
429 {
430 logStr = "MSGCODE_FRAME_DATA";
431 if (msg.size() >= 2)
432 {
433 uint8_t iData = msg[1];
434 logStr.AppendFormat(" %02x", iData);
435 m_currentframe.push_back(iData);
436 m_currentframe.eom = msg.eom();
437 }
438 m_controller->AddLog(CEC_LOG_DEBUG, logStr.c_str());
439 }
440 else
abbca718 441 {
78e8010a 442 m_frameBuffer.Push(msg);
abbca718 443 }
78e8010a
LOK
444
445 *bEom = msg.eom();
abbca718 446 }
78e8010a
LOK
447 break;
448 case MSGCODE_COMMAND_ACCEPTED:
449 m_controller->AddLog(CEC_LOG_DEBUG, "MSGCODE_COMMAND_ACCEPTED");
450 break;
451 case MSGCODE_TRANSMIT_SUCCEEDED:
452 m_controller->AddLog(CEC_LOG_DEBUG, "MSGCODE_TRANSMIT_SUCCEEDED");
453 *bTransmitSucceeded = true;
454 break;
455 case MSGCODE_RECEIVE_FAILED:
456 m_controller->AddLog(CEC_LOG_WARNING, "MSGCODE_RECEIVE_FAILED");
457 *bError = true;
458 break;
459 case MSGCODE_COMMAND_REJECTED:
460 m_controller->AddLog(CEC_LOG_WARNING, "MSGCODE_COMMAND_REJECTED");
461 *bError = true;
462 break;
463 case MSGCODE_TRANSMIT_FAILED_LINE:
464 m_controller->AddLog(CEC_LOG_WARNING, "MSGCODE_TRANSMIT_FAILED_LINE");
465 *bError = true;
466 break;
467 case MSGCODE_TRANSMIT_FAILED_ACK:
468 m_controller->AddLog(CEC_LOG_WARNING, "MSGCODE_TRANSMIT_FAILED_ACK");
469 *bError = true;
470 break;
471 case MSGCODE_TRANSMIT_FAILED_TIMEOUT_DATA:
472 m_controller->AddLog(CEC_LOG_WARNING, "MSGCODE_TRANSMIT_FAILED_TIMEOUT_DATA");
473 *bError = true;
474 break;
475 case MSGCODE_TRANSMIT_FAILED_TIMEOUT_LINE:
476 m_controller->AddLog(CEC_LOG_WARNING, "MSGCODE_TRANSMIT_FAILED_TIMEOUT_LINE");
477 *bError = true;
abbca718
LOK
478 break;
479 default:
480 break;
481 }
482}
483
9dee1670 484void CCECProcessor::ParseVendorId(cec_logical_address device, const cec_datapacket &data)
5f150ee2 485{
9dee1670 486 if (data.size < 3)
5f150ee2
LOK
487 {
488 m_controller->AddLog(CEC_LOG_WARNING, "invalid vendor ID received");
489 return;
490 }
491
a6b6469c
LOK
492 uint64_t iVendorId = ((uint64_t)data[0] << 3) +
493 ((uint64_t)data[1] << 2) +
494 (uint64_t)data[2];
5f150ee2
LOK
495
496 m_vendorIds[(uint8_t)device] = iVendorId;
9dee1670 497 m_vendorClasses[(uint8_t)device] = data.size >= 4 ? data[3] : 0;
5f150ee2
LOK
498
499 CStdString strLog;
500 strLog.Format("device %d: vendor = %s (%lld) class = %2x", (uint8_t)device, CECVendorIdToString(m_vendorIds[(uint8_t)device]), iVendorId, m_vendorClasses[(uint8_t)device]);
501 m_controller->AddLog(CEC_LOG_DEBUG, strLog.c_str());
502}
503
9dee1670 504void CCECProcessor::ParseCommand(cec_command &command)
abbca718 505{
abbca718 506 CStdString dataStr;
9dee1670
LOK
507 dataStr.Format(">> received frame: initiator: %u destination: %u", command.initiator, command.destination);
508 if (command.parameters.size > 1)
abbca718
LOK
509 {
510 dataStr += " data:";
06a1f7ce
LOK
511 for (uint8_t iPtr = 0; iPtr < command.parameters.size; iPtr++)
512 dataStr.AppendFormat(" %02x", (unsigned int)command.parameters[iPtr]);
abbca718 513 }
2abe74eb 514 m_controller->AddLog(CEC_LOG_DEBUG, dataStr.c_str());
abbca718 515
9dee1670 516 if (command.destination == m_iLogicalAddress)
abbca718 517 {
9dee1670 518 switch(command.opcode)
abbca718
LOK
519 {
520 case CEC_OPCODE_GIVE_PHYSICAL_ADDRESS:
521 ReportPhysicalAddress();
abbca718
LOK
522 break;
523 case CEC_OPCODE_GIVE_OSD_NAME:
9dee1670 524 ReportOSDName(command.initiator);
abbca718
LOK
525 break;
526 case CEC_OPCODE_GIVE_DEVICE_VENDOR_ID:
9dee1670 527 ReportVendorID(command.initiator);
abbca718 528 break;
5f150ee2 529 case CEC_OPCODE_VENDOR_COMMAND_WITH_ID:
9dee1670
LOK
530 ParseVendorId(command.initiator, command.parameters);
531 TransmitAbort(command.initiator, CEC_OPCODE_VENDOR_COMMAND_WITH_ID);
5f150ee2 532 break;
594eb5cf
LOK
533 case CEC_OPCODE_GIVE_DECK_STATUS:
534 // need to support opcodes play and deck control before doing anything with this
9dee1670 535 TransmitAbort(command.initiator, CEC_OPCODE_GIVE_DECK_STATUS);
594eb5cf 536 break;
abbca718 537 case CEC_OPCODE_MENU_REQUEST:
9dee1670
LOK
538 if (command.parameters[0] == CEC_MENU_REQUEST_TYPE_QUERY)
539 ReportMenuState(command.initiator);
abbca718
LOK
540 break;
541 case CEC_OPCODE_GIVE_DEVICE_POWER_STATUS:
9dee1670 542 ReportPowerState(command.initiator);
abbca718
LOK
543 break;
544 case CEC_OPCODE_GET_CEC_VERSION:
9dee1670 545 ReportCECVersion(command.initiator);
abbca718
LOK
546 break;
547 case CEC_OPCODE_USER_CONTROL_PRESSED:
9dee1670 548 if (command.parameters.size > 0)
abbca718 549 {
2abe74eb 550 m_controller->AddKey();
abbca718 551
9dee1670
LOK
552 if (command.parameters[0] <= CEC_USER_CONTROL_CODE_MAX)
553 m_controller->SetCurrentButton((cec_user_control_code) command.parameters[0]);
abbca718
LOK
554 }
555 break;
556 case CEC_OPCODE_USER_CONTROL_RELEASE:
2abe74eb 557 m_controller->AddKey();
abbca718 558 break;
3ab27798
LOK
559 case CEC_OPCODE_ROUTING_CHANGE:
560 m_controller->SetActiveView();
561 break;
abbca718 562 default:
9dee1670 563 m_controller->AddCommand(command);
abbca718
LOK
564 break;
565 }
566 }
9dee1670 567 else if (command.destination == CECDEVICE_BROADCAST)
abbca718 568 {
370757d1 569 CStdString strLog;
9dee1670 570 if (command.opcode == CEC_OPCODE_REQUEST_ACTIVE_SOURCE)
abbca718 571 {
9dee1670 572 strLog.Format(">> %i requests active source", (uint8_t) command.initiator);
370757d1 573 m_controller->AddLog(CEC_LOG_DEBUG, strLog.c_str());
abbca718
LOK
574 BroadcastActiveSource();
575 }
9dee1670 576 else if (command.opcode == CEC_OPCODE_SET_STREAM_PATH)
abbca718 577 {
9dee1670 578 if (command.parameters.size >= 2)
abbca718 579 {
9dee1670
LOK
580 int streamaddr = ((int)command.parameters[0] << 8) | ((int)command.parameters[1]);
581 strLog.Format(">> %i requests stream path from physical address %04x", command.initiator, streamaddr);
2abe74eb 582 m_controller->AddLog(CEC_LOG_DEBUG, strLog.c_str());
abbca718
LOK
583 if (streamaddr == m_physicaladdress)
584 BroadcastActiveSource();
585 }
586 }
c49c485b
LOK
587 else
588 {
9dee1670 589 m_controller->AddCommand(command);
c49c485b 590 }
abbca718
LOK
591 }
592 else
593 {
594 CStdString strLog;
9dee1670 595 strLog.Format("ignoring frame: destination: %u != %u", command.destination, (uint8_t)m_iLogicalAddress);
2abe74eb 596 m_controller->AddLog(CEC_LOG_DEBUG, strLog.c_str());
abbca718
LOK
597 }
598}
acec5f48
LOK
599
600const char *CCECProcessor::CECVendorIdToString(const uint64_t iVendorId)
601{
602 switch (iVendorId)
603 {
604 case CEC_VENDOR_SAMSUNG:
605 return "Samsung";
606 default:
607 return "Unknown";
608 }
609}