Commit | Line | Data |
---|---|---|
10570d97 JB |
1 | export enum MeterValueUnit { |
2 | WATT_HOUR = 'Wh', | |
3 | KILO_WATT_HOUR = 'kWh', | |
4 | VAR_HOUR = 'varh', | |
5 | KILO_VAR_HOUR = 'kvarh', | |
6 | WATT = 'W', | |
7 | KILO_WATT = 'kW', | |
8 | VOLT_AMP = 'VA', | |
9 | KILO_VOLT_AMP = 'kVA', | |
10 | VAR = 'var', | |
11 | KILO_VAR = 'kvar', | |
12 | AMP = 'A', | |
13 | VOLT = 'V', | |
14 | TEMP_CELSIUS = 'Celsius', | |
15 | TEMP_FAHRENHEIT = 'Fahrenheit', | |
16 | TEMP_KELVIN = 'K', | |
17 | PERCENT = 'Percent' | |
18 | } | |
19 | ||
20 | export enum MeterValueContext { | |
21 | INTERRUPTION_BEGIN = 'Interruption.Begin', | |
22 | INTERRUPTION_END = 'Interruption.End', | |
23 | OTHER = 'Other', | |
24 | SAMPLE_CLOCK = 'Sample.Clock', | |
25 | SAMPLE_PERIODIC = 'Sample.Periodic', | |
26 | TRANSACTION_BEGIN = 'Transaction.Begin', | |
27 | TRANSACTION_END = 'Transaction.End', | |
28 | TRIGGER = 'Trigger' | |
29 | } | |
30 | ||
c0560973 | 31 | export enum OCPP16MeterValueMeasurand { |
10570d97 JB |
32 | CURRENT_EXPORT = 'Current.Export', |
33 | CURRENT_IMPORT = 'Current.Import', | |
34 | CURRENT_OFFERED = 'Current.Offered', | |
35 | ENERGY_ACTIVE_EXPORT_REGISTER = 'Energy.Active.Export.Register', | |
36 | ENERGY_ACTIVE_IMPORT_REGISTER = 'Energy.Active.Import.Register', | |
37 | ENERGY_REACTIVE_EXPORT_REGISTER = 'Energy.Reactive.Export.Register', | |
38 | ENERGY_REACTIVE_IMPORT_REGISTER = 'Energy.Reactive.Import.Register', | |
39 | ENERGY_ACTIVE_EXPORT_INTERVAL = 'Energy.Active.Export.Interval', | |
40 | ENERGY_ACTIVE_IMPORT_INTERVAL = 'Energy.Active.Import.Interval', | |
41 | ENERGY_REACTIVE_EXPORT_INTERVAL = 'Energy.Reactive.Export.Interval', | |
42 | ENERGY_REACTIVE_IMPORT_INTERVAL = 'Energy.Reactive.Import.Interval', | |
43 | FREQUENCY = 'Frequency', | |
44 | POWER_ACTIVE_EXPORT = 'Power.Active.Export', | |
45 | POWER_ACTIVE_IMPORT = 'Power.Active.Import', | |
46 | POWER_FACTOR = 'Power.Factor', | |
47 | POWER_OFFERED = 'Power.Offered', | |
48 | POWER_REACTIVE_EXPORT = 'Power.Reactive.Export', | |
49 | POWER_REACTIVE_IMPORT = 'Power.Reactive.Import', | |
50 | FAN_RPM = 'RPM', | |
51 | STATE_OF_CHARGE = 'SoC', | |
52 | TEMPERATURE = 'Temperature', | |
53 | VOLTAGE = 'Voltage' | |
54 | } | |
55 | ||
56 | export enum MeterValueLocation { | |
57 | BODY = 'Body', | |
58 | CABLE = 'Cable', | |
59 | EV = 'EV', | |
60 | INLET = 'Inlet', | |
61 | OUTLET = 'Outlet' | |
62 | } | |
63 | ||
64 | export enum MeterValuePhase { | |
65 | L1 = 'L1', | |
66 | L2 = 'L2', | |
67 | L3 = 'L3', | |
68 | N = 'N', | |
69 | L1_N = 'L1-N', | |
70 | L2_N = 'L2-N', | |
71 | L3_N = 'L3-N', | |
72 | L1_L2 = 'L1-L2', | |
73 | L2_L3 = 'L2-L3', | |
74 | L3_L1 = 'L3-L1' | |
75 | } | |
76 | ||
77 | export enum MeterValueFormat { | |
78 | RAW = 'Raw', | |
79 | SIGNED_DATA = 'SignedData', | |
80 | } | |
81 | ||
c0560973 | 82 | export interface OCPP16SampledValue { |
10570d97 JB |
83 | value?: string; |
84 | unit?: MeterValueUnit; | |
85 | context?: MeterValueContext; | |
c0560973 | 86 | measurand?: OCPP16MeterValueMeasurand; |
10570d97 JB |
87 | phase?: MeterValuePhase; |
88 | location?: MeterValueLocation; | |
89 | format?: MeterValueFormat; | |
90 | } | |
91 | ||
f738a0e9 JB |
92 | export interface MeterValue { |
93 | timestamp: string; | |
c0560973 | 94 | sampledValue: OCPP16SampledValue[]; |
f738a0e9 JB |
95 | } |
96 | ||
97 | export interface MeterValuesRequest { | |
98 | connectorId: number; | |
99 | transactionId?: number; | |
100 | meterValue: MeterValue | MeterValue[]; | |
101 | } | |
102 | ||
103 | // eslint-disable-next-line @typescript-eslint/no-empty-interface | |
c0560973 | 104 | export interface MeterValuesResponse { } |
f738a0e9 | 105 |