Commit | Line | Data |
---|---|---|
c12b43d0 JB |
1 | import { EmptyObject } from '../../EmptyObject'; |
2 | ||
10570d97 JB |
3 | export enum MeterValueUnit { |
4 | WATT_HOUR = 'Wh', | |
5 | KILO_WATT_HOUR = 'kWh', | |
6 | VAR_HOUR = 'varh', | |
7 | KILO_VAR_HOUR = 'kvarh', | |
8 | WATT = 'W', | |
9 | KILO_WATT = 'kW', | |
10 | VOLT_AMP = 'VA', | |
11 | KILO_VOLT_AMP = 'kVA', | |
12 | VAR = 'var', | |
13 | KILO_VAR = 'kvar', | |
14 | AMP = 'A', | |
15 | VOLT = 'V', | |
16 | TEMP_CELSIUS = 'Celsius', | |
17 | TEMP_FAHRENHEIT = 'Fahrenheit', | |
18 | TEMP_KELVIN = 'K', | |
19 | PERCENT = 'Percent' | |
20 | } | |
21 | ||
22 | export enum MeterValueContext { | |
23 | INTERRUPTION_BEGIN = 'Interruption.Begin', | |
24 | INTERRUPTION_END = 'Interruption.End', | |
25 | OTHER = 'Other', | |
26 | SAMPLE_CLOCK = 'Sample.Clock', | |
27 | SAMPLE_PERIODIC = 'Sample.Periodic', | |
28 | TRANSACTION_BEGIN = 'Transaction.Begin', | |
29 | TRANSACTION_END = 'Transaction.End', | |
30 | TRIGGER = 'Trigger' | |
31 | } | |
32 | ||
c0560973 | 33 | export enum OCPP16MeterValueMeasurand { |
10570d97 JB |
34 | CURRENT_EXPORT = 'Current.Export', |
35 | CURRENT_IMPORT = 'Current.Import', | |
36 | CURRENT_OFFERED = 'Current.Offered', | |
37 | ENERGY_ACTIVE_EXPORT_REGISTER = 'Energy.Active.Export.Register', | |
38 | ENERGY_ACTIVE_IMPORT_REGISTER = 'Energy.Active.Import.Register', | |
39 | ENERGY_REACTIVE_EXPORT_REGISTER = 'Energy.Reactive.Export.Register', | |
40 | ENERGY_REACTIVE_IMPORT_REGISTER = 'Energy.Reactive.Import.Register', | |
41 | ENERGY_ACTIVE_EXPORT_INTERVAL = 'Energy.Active.Export.Interval', | |
42 | ENERGY_ACTIVE_IMPORT_INTERVAL = 'Energy.Active.Import.Interval', | |
43 | ENERGY_REACTIVE_EXPORT_INTERVAL = 'Energy.Reactive.Export.Interval', | |
44 | ENERGY_REACTIVE_IMPORT_INTERVAL = 'Energy.Reactive.Import.Interval', | |
45 | FREQUENCY = 'Frequency', | |
46 | POWER_ACTIVE_EXPORT = 'Power.Active.Export', | |
47 | POWER_ACTIVE_IMPORT = 'Power.Active.Import', | |
48 | POWER_FACTOR = 'Power.Factor', | |
49 | POWER_OFFERED = 'Power.Offered', | |
50 | POWER_REACTIVE_EXPORT = 'Power.Reactive.Export', | |
51 | POWER_REACTIVE_IMPORT = 'Power.Reactive.Import', | |
52 | FAN_RPM = 'RPM', | |
53 | STATE_OF_CHARGE = 'SoC', | |
54 | TEMPERATURE = 'Temperature', | |
55 | VOLTAGE = 'Voltage' | |
56 | } | |
57 | ||
58 | export enum MeterValueLocation { | |
59 | BODY = 'Body', | |
60 | CABLE = 'Cable', | |
61 | EV = 'EV', | |
62 | INLET = 'Inlet', | |
63 | OUTLET = 'Outlet' | |
64 | } | |
65 | ||
9ccca265 | 66 | export enum OCPP16MeterValuePhase { |
10570d97 JB |
67 | L1 = 'L1', |
68 | L2 = 'L2', | |
69 | L3 = 'L3', | |
70 | N = 'N', | |
71 | L1_N = 'L1-N', | |
72 | L2_N = 'L2-N', | |
73 | L3_N = 'L3-N', | |
74 | L1_L2 = 'L1-L2', | |
75 | L2_L3 = 'L2-L3', | |
76 | L3_L1 = 'L3-L1' | |
77 | } | |
78 | ||
79 | export enum MeterValueFormat { | |
80 | RAW = 'Raw', | |
81 | SIGNED_DATA = 'SignedData', | |
82 | } | |
83 | ||
c0560973 | 84 | export interface OCPP16SampledValue { |
10570d97 JB |
85 | value?: string; |
86 | unit?: MeterValueUnit; | |
87 | context?: MeterValueContext; | |
c0560973 | 88 | measurand?: OCPP16MeterValueMeasurand; |
9ccca265 | 89 | phase?: OCPP16MeterValuePhase; |
10570d97 JB |
90 | location?: MeterValueLocation; |
91 | format?: MeterValueFormat; | |
92 | } | |
93 | ||
fd0c36fa | 94 | export interface OCPP16MeterValue { |
f738a0e9 | 95 | timestamp: string; |
c0560973 | 96 | sampledValue: OCPP16SampledValue[]; |
f738a0e9 JB |
97 | } |
98 | ||
99 | export interface MeterValuesRequest { | |
100 | connectorId: number; | |
101 | transactionId?: number; | |
b02ab215 | 102 | meterValue: OCPP16MeterValue[]; |
f738a0e9 JB |
103 | } |
104 | ||
c12b43d0 | 105 | export type MeterValuesResponse = EmptyObject; |