README.md: fix template tunable default value
[e-mobility-charging-stations-simulator.git] / README.md
... / ...
CommitLineData
1# [charging-stations-simulator](https://github.com/jerome-benoit/charging-stations-simulator)
2
3## Summary
4
5Simple [node.js](https://nodejs.org/) program to simulate a set of charging stations based on the OCPP-J 1.6 protocol.
6
7## Prerequisites
8
9### Windows
10
11* [Chocolatey](https://chocolatey.org/):
12
13```powershell
14choco install -y nodejs-lts
15```
16
17### MacOSX
18
19* [Homebrew](https://brew.sh/):
20
21```shell
22brew install node@14
23```
24
25### GNU/Linux:
26
27* [NodeSource](https://github.com/nodesource/distributions) Node.js Binary Distributions for version 14.X
28
29## Configuration syntax
30
31All configuration files are in the JSON standard format.
32
33The charging stations simulator's main configuration parameters must be within the `src/assets/config.json` file. A configuration template file is available at [src/assets/config-template.json](src/assets/config-template.json).
34
35All charging station templates are in the directory [src/assets/station-templates](src/assets/station-templates).
36
37A list of RFID tags must be defined for the automatic transaction generator with the default location and name `src/assets/authorization-tags.json`. A template file is available at [src/assets/authorization-tags-template.json](src/assets/authorization-tags-template.json).
38
39The charging stations simulator have an automatic configuration files reload feature at change for:
40* main configuration;
41* charging station templates;
42* authorization RFID tags.
43
44But the modifications to test have to be done to the files in the build result directory [dist/assets](dist/assets). Once the modifications are finished, they have to be reported or copied to the matching files in the build source directory [src/assets](src/assets) to ensure they will be taken into account at next build.
45
46### Main configuration
47
48**src/assets/config.json**:
49
50Key | Value(s) | Default Value | Value type | Description
51--- | -------| --------------| ---------- | ------------
52supervisionURLs | | [] | string[] | array of connection URIs to OCPP-J servers
53distributeStationsToTenantsEqually | true/false | true | boolean | distribute charging stations uniformly to the OCPP-J servers
54workerProcess | workerSet/staticPool/dynamicPool | workerSet | string | worker threads process type
55workerStartDelay | | 500 | integer | milliseconds to wait at charging station worker threads startup
56workerPoolMinSize | | 4 | integer | worker threads pool minimum number of threads
57workerPoolMaxSize | | 16 | integer | worker threads pool maximum number of threads
58workerPoolStrategy | ROUND_ROBIN/LESS_RECENTLY_USED/... | [poolifier](https://github.com/poolifier/poolifier) default: ROUND_ROBBIN | string | worker threads pool [poolifier](https://github.com/poolifier/poolifier) worker choice strategy
59chargingStationsPerWorker | | 1 | integer | number of charging stations per worker threads for the `workerSet` process type
60logStatisticsInterval | | 60 | integer | seconds between charging stations statistics output in the logs
61logConsole | true/false | false | boolean | output logs on the console
62logFormat | | simple | string | winston log format
63logRotate | true/false | true | boolean | enable daily log files rotation
64logMaxFiles | | 7 | integer | maximum number of log files to keep
65logLevel | emerg/alert/crit/error/warning/notice/info/debug | info | string | winston logging level
66logFile | | combined.log | string | log file relative path
67logErrorFile | | error.log | string | error log file relative path
68performanceStorage | | { "enabled": false, "type": "jsonfile", "file:///performanceRecords.json" } | { enabled: string; type: string; URI: string; } where type can be 'jsonfile' or 'mongodb' | performance storage configuration section
69stationTemplateURLs | | {}[] | { file: string; numberOfStations: number; }[] | array of charging station templates URIs configuration section (template file name and number of stations)
70
71#### Worker process model:
72
73- **workerSet**:
74 Worker set executing each a static number (chargingStationsPerWorker) of simulated charging stations from the total
75
76- **staticPool**:
77 Statically sized worker pool executing a static total number of simulated charging stations
78
79- **dynamicPool**:
80 Dynamically sized worker pool executing a static total number of simulated charging stations
81
82### Charging station template
83
84Key | Value(s) | Default Value | Value type | Description
85--- | -------| --------------| ---------- | ------------
86supervisionURL | | '' | string | connection URI to OCPP-J server
87supervisionUser | | '' | string | basic HTTP authentication user to OCPP-J server
88supervisionPassword | | '' | string | basic HTTP authentication password to OCPP-J server
89supervisionURLOCPPConfiguration | | false | boolean | Allow supervision URL configuration via a vendor OCPP parameter key
90supervisionURLOCPPKey | | '' | string | The vendor string that will be used as a vendor OCPP parameter key to set the supervision URL
91ocppVersion | 1.6 | 1.6 | string | OCPP version
92ocppProtocol | json | json | string | OCPP protocol
93wsOptions | | {} | ClientOptions & ClientRequestArgs | [ws](https://github.com/websockets/ws) and node.js [http](https://nodejs.org/api/http.html) clients options intersection
94authorizationFile | | '' | string | RFID tags list file relative to src/assets path
95baseName | | '' | string | base name to build charging stations name
96nameSuffix | | '' | string | name suffix to build charging stations name
97fixedName | true/false | false | boolean | use the baseName as the charging stations unique name
98chargePointModel | | '' | string | charging stations model
99chargePointVendor | | '' | string | charging stations vendor
100chargeBoxSerialNumberPrefix | | '' | string | charging stations serial number prefix
101firmwareVersion | | '' | string | charging stations firmware version
102power | | | float\|float[] | charging stations maximum power value(s)
103powerSharedByConnectors | true/false | false | boolean | charging stations power shared by its connectors
104powerUnit | W/kW | W | string | charging stations power unit
105currentOutType | AC/DC | AC | string | charging stations current out type
106voltageOut | | AC:230/DC:400 | integer | charging stations voltage out
107numberOfPhases | 0/1/3 | AC:3/DC:0 | integer | charging stations number of phase(s)
108numberOfConnectors | | | integer\|integer[] | charging stations number of connector(s)
109useConnectorId0 | true/false | true | boolean | use connector id 0 definition from the template
110randomConnectors | true/false | false | boolean | randomize runtime connector id affectation from the connector id definition in template
111resetTime | | 60 | integer | seconds to wait before the charging stations come back at reset
112autoRegister | true/false | false | boolean | set the charging station as registered at boot notification for testing purpose
113autoReconnectMaxRetries | | -1 (unlimited) | integer | connection retries to the OCPP-J server
114reconnectExponentialDelay | true/false | false | boolean | connection delay retry to the OCPP-J server
115registrationMaxRetries | | -1 (unlimited) | integer | charging stations boot notification retries
116enableStatistics | true/false | true | boolean | enable charging stations statistics
117mayAuthorizeAtRemoteStart | true/false | true | boolean | always send authorize at remote start transaction when AuthorizeRemoteTxRequests is enabled
118beginEndMeterValues | true/false | false | boolean | enable Transaction.{Begin,End} MeterValues
119outOfOrderEndMeterValues | true/false | false | boolean | send Transaction.End MeterValues out of order
120meteringPerTransaction | true/false | true | boolean | enable metering history on a per transaction basis
121transactionDataMeterValues | true/false | false | boolean | enable transaction data MeterValues at stop transaction
122mainVoltageMeterValues | true/false | true | boolean | include charging station main voltage MeterValues on three phased charging stations
123phaseLineToLineVoltageMeterValues | true/false | true | boolean | include charging station line to line voltage MeterValues on three phased charging stations
124Configuration | | | ChargingStationConfiguration | charging stations OCPP parameters configuration section
125AutomaticTransactionGenerator | | | AutomaticTransactionGenerator | charging stations ATG configuration section
126Connectors | | | Connectors | charging stations connectors configuration section
127
128#### Configuration section
129
130```json
131 "Configuration": {
132 "configurationKey": [
133 ...
134 {
135 "key": "StandardKey",
136 "readonly": false,
137 "value": "StandardValue",
138 "visible": true,
139 "reboot": false
140 },
141 ...
142 {
143 "key": "VendorKey",
144 "readonly": false,
145 "value": "VendorValue",
146 "visible": false,
147 "reboot": true
148 },
149 ...
150 ]
151 }
152```
153
154#### AutomaticTransactionGenerator section
155
156```json
157 "AutomaticTransactionGenerator": {
158 "enable": false,
159 "minDuration": 60,
160 "maxDuration": 80,
161 "minDelayBetweenTwoTransactions": 15,
162 "maxDelayBetweenTwoTransactions": 30,
163 "probabilityOfStart": 1,
164 "stopAfterHours": 0.3,
165 "stopOnConnectionFailure": true,
166 "requireAuthorize": true
167 }
168```
169#### Connectors section
170
171```json
172 "Connectors": {
173 "0": {},
174 "1": {
175 "bootStatus": "Available",
176 "MeterValues": [
177 ...
178 {
179 "unit": "W",
180 "measurand": "Power.Active.Import",
181 "phase": "L1-N",
182 "value": "5000",
183 "fluctuationPercent": "10"
184 },
185 ...
186 {
187 "unit": "A",
188 "measurand": "Current.Import"
189 },
190 ...
191 {
192 "unit": "Wh"
193 },
194 ...
195 ]
196 }
197 },
198```
199
200## Start
201
202To start the program, run: `npm start`.
203
204## Docker
205
206In the [docker](./docker) folder:
207
208```bash
209make
210```
211
212Or with the optional git submodules:
213
214```bash
215make SUBMODULES_INIT=true
216```
217
218## OCPP-J commands supported
219
220### Version 1.6
221
222#### Core Profile
223
224- :white_check_mark: Authorize
225- :white_check_mark: BootNotification
226- :white_check_mark: ChangeAvailability
227- :white_check_mark: ChangeConfiguration
228- :white_check_mark: ClearCache
229- :x: DataTransfer
230- :white_check_mark: GetConfiguration
231- :white_check_mark: Heartbeat
232- :white_check_mark: MeterValues
233- :white_check_mark: RemoteStartTransaction
234- :white_check_mark: RemoteStopTransaction
235- :white_check_mark: Reset
236- :white_check_mark: StartTransaction
237- :white_check_mark: StatusNotification
238- :white_check_mark: StopTransaction
239- :white_check_mark: UnlockConnector
240
241#### Firmware Management Profile
242
243- :white_check_mark: GetDiagnostics
244- :white_check_mark: DiagnosticsStatusNotification
245- :x: FirmwareStatusNotification
246- :x: UpdateFirmware
247
248#### Local Auth List Management Profile
249
250- :x: GetLocalListVersion
251- :x: SendLocalList
252
253#### Reservation Profile
254
255- :x: CancelReservation
256- :x: ReserveNow
257
258#### Smart Charging Profile
259
260- :white_check_mark: ClearChargingProfile
261- :white_check_mark: GetCompositeSchedule
262- :white_check_mark: SetChargingProfile
263
264#### Remote Trigger Profile
265
266- :white_check_mark: TriggerMessage
267
268## OCPP-J standard parameters supported
269
270All kind of OCPP parameters are supported in a charging station template. The list here mention the standard ones also handled automatically in the simulator.
271
272### Version 1.6
273
274#### Core Profile
275
276- :white_check_mark: AuthorizeRemoteTxRequests (type: boolean) (units: -)
277- :x: ClockAlignedDataInterval (type: integer) (units: seconds)
278- :white_check_mark: ConnectionTimeOut (type: integer) (units: seconds)
279- :x: GetConfigurationMaxKeys (type: integer) (units: -)
280- :white_check_mark: HeartbeatInterval (type: integer) (units: seconds)
281- :x: LocalAuthorizeOffline (type: boolean) (units: -)
282- :x: LocalPreAuthorize (type: boolean) (units: -)
283- :x: MeterValuesAlignedData (type: CSL) (units: -)
284- :white_check_mark: MeterValuesSampledData (type: CSL) (units: -)
285- :white_check_mark: MeterValueSampleInterval (type: integer) (units: seconds)
286- :white_check_mark: NumberOfConnectors (type: integer) (units: -)
287- :x: ResetRetries (type: integer) (units: times)
288- :white_check_mark: ConnectorPhaseRotation (type: CSL) (units: -)
289- :x: StopTransactionOnEVSideDisconnect (type: boolean) (units: -)
290- :x: StopTransactionOnInvalidId (type: boolean) (units: -)
291- :x: StopTxnAlignedData (type: CSL) (units: -)
292- :x: StopTxnSampledData (type: CSL) (units: -)
293- :white_check_mark: SupportedFeatureProfiles (type: CSL) (units: -)
294- :x: TransactionMessageAttempts (type: integer) (units: times)
295- :x: TransactionMessageRetryInterval (type: integer) (units: seconds)
296- :x: UnlockConnectorOnEVSideDisconnect (type: boolean) (units: -)
297- :white_check_mark: WebSocketPingInterval (type: integer) (units: seconds)
298
299#### Firmware Management Profile
300
301- *none*
302
303#### Local Auth List Management Profile
304
305- :white_check_mark: LocalAuthListEnabled (type: boolean) (units: -)
306- :x: LocalAuthListMaxLength (type: integer) (units: -)
307- :x: SendLocalListMaxLength (type: integer) (units: -)
308
309#### Reservation Profile
310
311- *none*
312
313#### Smart Charging Profile
314
315- :x: ChargeProfileMaxStackLevel (type: integer) (units: -)
316- :x: ChargingScheduleAllowedChargingRateUnit (type: CSL) (units: -)
317- :x: ChargingScheduleMaxPeriods (type: integer) (units: -)
318- :x: MaxChargingProfilesInstalled (type: integer) (units: -)
319
320#### Remote Trigger Profile
321
322- *none*
323
324## License
325
326This file and all other files in this repository are licensed under the Apache Software License, v.2 and copyrighted under the copyright in [NOTICE](NOTICE) file, except as noted otherwise in the [LICENSE](LICENSE) file or the code source file header.
327