Commit | Line | Data |
---|---|---|
1 | <!-- markdownlint-disable-file MD033 MD024 --> | |
2 | <div align="center"> | |
3 | ||
4 | # [e-Mobility charging stations simulator](https://github.com/sap/e-mobility-charging-stations-simulator) | |
5 | ||
6 | </div> | |
7 | ||
8 | <div align="center"> | |
9 | ||
10 | [](https://github.com/SAP/e-mobility-charging-stations-simulator/graphs/traffic) | |
11 | [](https://github.com/SAP/e-mobility-charging-stations-simulator/graphs/commit-activity) | |
12 | [](https://github.com/SAP/e-mobility-charging-stations-simulator/actions/workflows/ci.yml) | |
13 | [](https://api.reuse.software/info/github.com/SAP/e-mobility-charging-stations-simulator) | |
14 | [](https://github.com/neostandard/neostandard) | |
15 | ||
16 | </div> | |
17 | ||
18 | Simple [node.js](https://nodejs.org/) software to simulate and scale a set of charging stations based on the OCPP-J protocol as part of [SAP e-Mobility](https://www.sap.com/products/scm/e-mobility.html) solution. | |
19 | ||
20 | ## Table of contents | |
21 | ||
22 | - [Installation](#installation) | |
23 | - [Prerequisites](#prerequisites) | |
24 | - [Windows](#windows) | |
25 | - [MacOSX](#macosx) | |
26 | - [GNU/Linux](#gnulinux) | |
27 | - [Development prerequisites (optional)](#development-prerequisites-optional) | |
28 | - [Unix](#unix) | |
29 | - [Windows](#windows-1) | |
30 | - [Branching model](#branching-model) | |
31 | - [Dependencies](#dependencies) | |
32 | - [Initial configuration](#initial-configuration) | |
33 | - [Start simulator](#start-simulator) | |
34 | - [Start Web UI](#start-web-ui) | |
35 | - [Configuration files syntax](#configuration-files-syntax) | |
36 | - [Charging stations simulator configuration](#charging-stations-simulator-configuration) | |
37 | - [Charging station template configuration](#charging-station-template-configuration) | |
38 | - [Charging station configuration](#charging-station-configuration) | |
39 | - [Docker](#docker) | |
40 | - [OCPP-J commands supported](#ocpp-j-commands-supported) | |
41 | - [Version 1.6](#version-16) | |
42 | - [Version 2.x.x](#version-2xx) | |
43 | - [OCPP-J standard parameters supported](#ocpp-j-standard-parameters-supported) | |
44 | - [Version 1.6](#version-16-1) | |
45 | - [Version 2.x.x](#version-2xx-1) | |
46 | - [UI Protocol](#ui-protocol) | |
47 | - [Websocket Protocol](#websocket-protocol) | |
48 | - [HTTP Protocol](#http-protocol) | |
49 | - [Support, Feedback, Contributing](#support-feedback-contributing) | |
50 | - [Code of Conduct](#code-of-conduct) | |
51 | - [Licensing](#licensing) | |
52 | ||
53 | ## Installation | |
54 | ||
55 | ### Prerequisites | |
56 | ||
57 | Install the [node.js](https://nodejs.org/) current LTS or superior version runtime environment: | |
58 | ||
59 | #### Windows | |
60 | ||
61 | - [Chocolatey](https://chocolatey.org/): | |
62 | ||
63 | ```powershell | |
64 | choco install -y nodejs | |
65 | ``` | |
66 | ||
67 | #### MacOSX | |
68 | ||
69 | - [Homebrew](https://brew.sh/): | |
70 | ||
71 | ```shell | |
72 | brew install node | |
73 | ``` | |
74 | ||
75 | #### GNU/Linux | |
76 | ||
77 | - [NodeSource](https://github.com/nodesource/distributions) node.js binary distributions for all supported versions. | |
78 | ||
79 | ### Development prerequisites (optional) | |
80 | ||
81 | Install [volta](https://volta.sh/) for managing automatically the node.js runtime and package manager version: | |
82 | ||
83 | #### Unix | |
84 | ||
85 | ```shell | |
86 | curl https://get.volta.sh | bash | |
87 | ``` | |
88 | ||
89 | #### Windows | |
90 | ||
91 | ```powershell | |
92 | choco install -y volta | |
93 | ``` | |
94 | ||
95 | Setup [volta](https://volta.sh/) with [pnpm](https://github.com/pnpm/pnpm) package manager support: https://docs.volta.sh/advanced/pnpm | |
96 | ||
97 | ### Branching model | |
98 | ||
99 | The `main` branch is the default development branch. | |
100 | The `vX` branches are the maintenance branches for the corresponding major version `X`. | |
101 | The `vX.Y` branches are the maintenance branches for the corresponding major and minor version `X.Y`. | |
102 | ||
103 | ### Dependencies | |
104 | ||
105 | Enable corepack, if [volta](https://volta.sh/) is not installed and configured, and install latest pnpm version: | |
106 | ||
107 | ```shell | |
108 | corepack enable | |
109 | corepack prepare pnpm@latest --activate | |
110 | ``` | |
111 | ||
112 | In the repository root, run the following command: | |
113 | ||
114 | ```shell | |
115 | pnpm install | |
116 | ``` | |
117 | ||
118 | ## Initial configuration | |
119 | ||
120 | Copy the configuration template file [src/assets/config-template.json](./src/assets/config-template.json) to [src/assets/config.json](./src/assets/config.json). | |
121 | Copy the RFID tags template file [src/assets/idtags-template.json](./src/assets/idtags-template.json) to [src/assets/idtags.json](./src/assets/idtags.json). | |
122 | ||
123 | Tweak them to your needs by following the section [configuration files syntax](#configuration-files-syntax): OCPP server supervision URL(s), charging station templates, etc. | |
124 | ||
125 | ## Start simulator | |
126 | ||
127 | ```shell | |
128 | pnpm start | |
129 | ``` | |
130 | ||
131 | ## Start Web UI | |
132 | ||
133 | See Web UI [README.md](./ui/web/README.md) for more information. | |
134 | ||
135 | ## Configuration files syntax | |
136 | ||
137 | All configuration files are using the JSON standard syntax. | |
138 | ||
139 | **Configuration files locations**: | |
140 | ||
141 | - charging stations simulator configuration: [src/assets/config.json](./src/assets/config.json); | |
142 | - charging station configuration templates: [src/assets/station-templates](./src/assets/station-templates); | |
143 | - charging station configurations: [dist/assets/configurations](./dist/assets/configurations); | |
144 | - charging station RFID tags lists: [src/assets](./src/assets). | |
145 | ||
146 | The charging stations simulator's configuration parameters must be within the `src/assets/config.json` file. A charging station simulator configuration template file is available at [src/assets/config-template.json](./src/assets/config-template.json). | |
147 | ||
148 | All charging station configuration templates are in the directory [src/assets/station-templates](./src/assets/station-templates). | |
149 | ||
150 | A list of RFID tags must be defined for the automatic transaction generator in a file with the default location and name: `src/assets/idtags.json`. A template file is available at [src/assets/idtags-template.json](./src/assets/idtags-template.json). | |
151 | ||
152 | **Configuration files hierarchy and priority**: | |
153 | ||
154 | 1. charging station configuration: [dist/assets/configurations](./dist/assets/configurations); | |
155 | 2. charging station configuration template: [src/assets/station-templates](./src/assets/station-templates); | |
156 | 3. charging stations simulator configuration: [src/assets/config.json](./src/assets/config.json). | |
157 | ||
158 | The charging stations simulator has an automatic configuration files reload feature at change for: | |
159 | ||
160 | - charging stations simulator configuration; | |
161 | - charging station configuration templates; | |
162 | - charging station authorization RFID tags lists. | |
163 | ||
164 | But the modifications to test have to be done to the files in the build target directory [dist/assets](./dist/assets). Once the modifications are done, they have to be reported to the matching files in the build source directory [src/assets](./src/assets) to ensure they will be taken into account at next build. | |
165 | ||
166 | ### Charging stations simulator configuration | |
167 | ||
168 | **src/assets/config.json**: | |
169 | ||
170 | | Key | Value(s) | Default Value | Value type | Description | | |
171 | | -------------------------- | -------------------------------------------- | ----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------- | ------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------- | --------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------- | | |
172 | | supervisionUrls | | [] | string \| string[] | string or strings array containing global connection URIs to OCPP-J servers | | |
173 | | supervisionUrlDistribution | round-robin/random/charging-station-affinity | charging-station-affinity | string | supervision urls distribution policy to simulated charging stations | | |
174 | | log | | {<br />"enabled": true,<br />"file": "logs/combined.log",<br />"errorFile": "logs/error.log",<br />"statisticsInterval": 60,<br />"level": "info",<br />"console": false,<br />"format": "simple",<br />"rotate": true<br />} | {<br />enabled?: boolean;<br />file?: string;<br />errorFile?: string;<br />statisticsInterval?: number;<br />level?: string;<br />console?: boolean;<br />format?: string;<br />rotate?: boolean;<br />maxFiles?: string \| number;<br />maxSize?: string \| number;<br />} | Log configuration section:<br />- _enabled_: enable logging<br />- _file_: log file relative path<br />- _errorFile_: error log file relative path<br />- _statisticsInterval_: seconds between charging stations statistics output in the logs<br />- _level_: emerg/alert/crit/error/warning/notice/info/debug [winston](https://github.com/winstonjs/winston) logging level</br >- _console_: output logs on the console<br />- _format_: [winston](https://github.com/winstonjs/winston) log format<br />- _rotate_: enable daily log files rotation<br />- _maxFiles_: maximum number of log files: https://github.com/winstonjs/winston-daily-rotate-file#options<br />- _maxSize_: maximum size of log files in bytes, or units of kb, mb, and gb: https://github.com/winstonjs/winston-daily-rotate-file#options | | |
175 | | worker | | {<br />"processType": "workerSet",<br />"startDelay": 500,<br />"elementAddDelay": 0,<br />"elementsPerWorker": 'auto',<br />"poolMinSize": 4,<br />"poolMaxSize": 16<br />} | {<br />processType?: WorkerProcessType;<br />startDelay?: number;<br />elementAddDelay?: number;<br />elementsPerWorker?: number \| 'auto' \| 'all';<br />poolMinSize?: number;<br />poolMaxSize?: number;<br />resourceLimits?: ResourceLimits;<br />} | Worker configuration section:<br />- _processType_: worker threads process type (`workerSet`/`fixedPool`/`dynamicPool`)<br />- _startDelay_: milliseconds to wait at worker threads startup (only for `workerSet` worker threads process type)<br />- _elementAddDelay_: milliseconds to wait between charging station add<br />- _elementsPerWorker_: number of charging stations per worker threads for the `workerSet` process type (`auto` means (number of stations) / (number of CPUs) \* 1.5 if (number of stations) > (number of CPUs), otherwise 1; `all` means a unique worker will run all charging stations)<br />- _poolMinSize_: worker threads pool minimum number of threads</br >- _poolMaxSize_: worker threads pool maximum number of threads<br />- _resourceLimits_: worker threads [resource limits](https://nodejs.org/api/worker_threads.html#new-workerfilename-options) object option | | |
176 | | uiServer | | {<br />"enabled": false,<br />"type": "ws",<br />"version": "1.1",<br />"options": {<br />"host": "localhost",<br />"port": 8080<br />}<br />} | {<br />enabled?: boolean;<br />type?: ApplicationProtocol;<br />version?: ApplicationProtocolVersion;<br />options?: ServerOptions;<br />authentication?: {<br />enabled: boolean;<br />type: AuthenticationType;<br />username?: string;<br />password?: string;<br />}<br />} | UI server configuration section:<br />- _enabled_: enable UI server<br />- _type_: 'http' or 'ws'<br />- _version_: HTTP version '1.1' or '2.0'<br />- _options_: node.js net module [listen options](https://nodejs.org/api/net.html#serverlistenoptions-callback)<br />- _authentication_: authentication type configuration section | | |
177 | | performanceStorage | | {<br />"enabled": true,<br />"type": "none",<br />} | {<br />enabled?: boolean;<br />type?: string;<br />uri?: string;<br />} | Performance storage configuration section:<br />- _enabled_: enable performance storage<br />- _type_: 'jsonfile', 'mongodb' or 'none'<br />- _uri_: storage URI | | |
178 | | stationTemplateUrls | | {}[] | {<br />file: string;<br />numberOfStations: number;<br />provisionedNumberOfStations?: number;<br />}[] | array of charging station templates URIs configuration section:<br />- _file_: charging station configuration template file relative path<br />- _numberOfStations_: template number of stations at startup<br />- _provisionedNumberOfStations_: template provisioned number of stations after startup | | |
179 | ||
180 | #### Worker process model | |
181 | ||
182 | - **workerSet**: | |
183 | Worker set executing each a fixed number (elementsPerWorker) of simulated charging stations from the total | |
184 | ||
185 | - **fixedPool**: | |
186 | Fixedly sized worker pool executing a fixed total number of simulated charging stations | |
187 | ||
188 | - **dynamicPool** (experimental): | |
189 | Dynamically sized worker pool executing a fixed total number of simulated charging stations | |
190 | ||
191 | ### Charging station template configuration | |
192 | ||
193 | **src/assets/station-templates/\<name\>.json**: | |
194 | ||
195 | | Key | Value(s) | Default Value | Value type | Description | | |
196 | | ---------------------------------------------------- | ------------- | ---------------------------------------------------------------------------------------------------------------------------------- | ----------------------------------------------------------------------------------------------------------------------------------------------------------------------------- | -------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------- | | |
197 | | supervisionUrls | | [] | string \| string[] | string or strings array containing connection URIs to OCPP-J servers | | |
198 | | supervisionUser | | undefined | string | basic HTTP authentication user to OCPP-J server | | |
199 | | supervisionPassword | | undefined | string | basic HTTP authentication password to OCPP-J server | | |
200 | | supervisionUrlOcppConfiguration | true/false | false | boolean | enable supervision URL configuration via a vendor OCPP parameter key | | |
201 | | supervisionUrlOcppKey | | 'ConnectionUrl' | string | the vendor string that will be used as a vendor OCPP parameter key to set the supervision URL | | |
202 | | autoStart | true/false | true | boolean | enable automatic start of added charging station from template | | |
203 | | ocppVersion | 1.6/2.0/2.0.1 | 1.6 | string | OCPP version | | |
204 | | ocppProtocol | json | json | string | OCPP protocol | | |
205 | | ocppStrictCompliance | true/false | true | boolean | enable strict adherence to the OCPP version and protocol specifications with OCPP commands PDU validation against [OCA](https://www.openchargealliance.org/) JSON schemas | | |
206 | | ocppPersistentConfiguration | true/false | true | boolean | enable persistent OCPP parameters storage by charging stations 'hashId'. The persistency is ensured by the charging stations configuration files in [dist/assets/configurations](./dist/assets/configurations) | | |
207 | | stationInfoPersistentConfiguration | true/false | true | boolean | enable persistent station information and specifications storage by charging stations 'hashId'. The persistency is ensured by the charging stations configuration files in [dist/assets/configurations](./dist/assets/configurations) | | |
208 | | automaticTransactionGeneratorPersistentConfiguration | true/false | true | boolean | enable persistent automatic transaction generator configuration storage by charging stations 'hashId'. The persistency is ensured by the charging stations configuration files in [dist/assets/configurations](./dist/assets/configurations) | | |
209 | | wsOptions | | {} | ClientOptions & ClientRequestArgs | [ws](https://github.com/websockets/ws) and node.js [http](https://nodejs.org/api/http.html) clients options intersection | | |
210 | | idTagsFile | | undefined | string | RFID tags list file relative to [src/assets](./src/assets) path | | |
211 | | baseName | | undefined | string | base name to build charging stations id | | |
212 | | nameSuffix | | undefined | string | name suffix to build charging stations id | | |
213 | | fixedName | true/false | false | boolean | use the 'baseName' as the charging stations unique name | | |
214 | | chargePointModel | | undefined | string | charging stations model | | |
215 | | chargePointVendor | | undefined | string | charging stations vendor | | |
216 | | chargePointSerialNumberPrefix | | undefined | string | charge point serial number prefix | | |
217 | | chargeBoxSerialNumberPrefix | | undefined | string | charge box serial number prefix (deprecated since OCPP 1.6) | | |
218 | | firmwareVersionPattern | | Semantic versioning regular expression: https://semver.org/#is-there-a-suggested-regular-expression-regex-to-check-a-semver-string | string | charging stations firmware version pattern | | |
219 | | firmwareVersion | | undefined | string | charging stations firmware version | | |
220 | | power | | | float \| float[] | charging stations maximum power value(s) | | |
221 | | powerSharedByConnectors | true/false | false | boolean | charging stations power shared by its connectors | | |
222 | | powerUnit | W/kW | W | string | charging stations power unit | | |
223 | | currentOutType | AC/DC | AC | string | charging stations current out type | | |
224 | | voltageOut | | AC:230/DC:400 | integer | charging stations voltage out | | |
225 | | numberOfPhases | 0/1/3 | AC:3/DC:0 | integer | charging stations number of phase(s) | | |
226 | | numberOfConnectors | | | integer \| integer[] | charging stations number of connector(s) | | |
227 | | useConnectorId0 | true/false | true | boolean | use connector id 0 definition from the charging station configuration template | | |
228 | | randomConnectors | true/false | false | boolean | randomize runtime connector id affectation from the connector id definition in charging station configuration template | | |
229 | | resetTime | | 60 | integer | seconds to wait before the charging stations come back at reset | | |
230 | | autoRegister | true/false | false | boolean | set charging stations as registered at boot notification for testing purpose | | |
231 | | autoReconnectMaxRetries | | -1 (unlimited) | integer | connection retries to the OCPP-J server | | |
232 | | reconnectExponentialDelay | true/false | false | boolean | connection delay retry to the OCPP-J server | | |
233 | | registrationMaxRetries | | -1 (unlimited) | integer | charging stations boot notification retries | | |
234 | | amperageLimitationOcppKey | | undefined | string | charging stations OCPP parameter key used to set the amperage limit, per phase for each connector on AC and global for DC | | |
235 | | amperageLimitationUnit | A/cA/dA/mA | A | string | charging stations amperage limit unit | | |
236 | | enableStatistics | true/false | false | boolean | enable charging stations statistics | | |
237 | | remoteAuthorization | true/false | true | boolean | enable RFID tags remote authorization | | |
238 | | beginEndMeterValues | true/false | false | boolean | enable Transaction.{Begin,End} MeterValues | | |
239 | | outOfOrderEndMeterValues | true/false | false | boolean | send Transaction.End MeterValues out of order. Need to relax OCPP specifications strict compliance ('ocppStrictCompliance' parameter) | | |
240 | | meteringPerTransaction | true/false | true | boolean | enable metering history on a per transaction basis | | |
241 | | transactionDataMeterValues | true/false | false | boolean | enable transaction data MeterValues at stop transaction | | |
242 | | stopTransactionsOnStopped | true/false | true | boolean | enable stop transactions on charging station stop | | |
243 | | mainVoltageMeterValues | true/false | true | boolean | include charging stations main voltage MeterValues on three phased charging stations | | |
244 | | phaseLineToLineVoltageMeterValues | true/false | false | boolean | include charging stations line to line voltage MeterValues on three phased charging stations | | |
245 | | customValueLimitationMeterValues | true/false | true | boolean | enable limitation on custom fluctuated value in MeterValues | | |
246 | | firmwareUpgrade | | {<br />"versionUpgrade": {<br />"step": 1<br />},<br />"reset": true<br />} | {<br />versionUpgrade?: {<br />patternGroup?: number;<br />step?: number;<br />};<br />reset?: boolean;<br />failureStatus?: 'DownloadFailed' \| 'InstallationFailed';<br />} | Configuration section for simulating firmware upgrade support. | | |
247 | | commandsSupport | | {<br />"incomingCommands": {},<br />"outgoingCommands": {}<br />} | {<br /> incomingCommands: Record<IncomingRequestCommand, boolean>;<br />outgoingCommands?: Record<RequestCommand, boolean>;<br />} | Configuration section for OCPP commands support. Empty section or subsections means all implemented OCPP commands are supported | | |
248 | | messageTriggerSupport | | {} | Record<MessageTrigger, boolean> | Configuration section for OCPP commands trigger support. Empty section means all implemented OCPP trigger commands are supported | | |
249 | | Configuration | | | ChargingStationOcppConfiguration | charging stations OCPP parameters configuration section | | |
250 | | AutomaticTransactionGenerator | | | AutomaticTransactionGeneratorConfiguration | charging stations ATG configuration section | | |
251 | | Connectors | | | Record<string, ConnectorStatus> | charging stations connectors configuration section | | |
252 | | Evses | | | Record<string, EvseTemplate> | charging stations EVSEs configuration section | | |
253 | ||
254 | #### Configuration section syntax example | |
255 | ||
256 | ```json | |
257 | "Configuration": { | |
258 | "configurationKey": [ | |
259 | ... | |
260 | { | |
261 | "key": "StandardKey", | |
262 | "readonly": false, | |
263 | "value": "StandardValue", | |
264 | "visible": true, | |
265 | "reboot": false | |
266 | }, | |
267 | ... | |
268 | { | |
269 | "key": "VendorKey", | |
270 | "readonly": false, | |
271 | "value": "VendorValue", | |
272 | "visible": false, | |
273 | "reboot": true | |
274 | }, | |
275 | ... | |
276 | ] | |
277 | } | |
278 | ``` | |
279 | ||
280 | #### AutomaticTransactionGenerator section syntax example | |
281 | ||
282 | ##### Type definition: | |
283 | ||
284 | ```ts | |
285 | type AutomaticTransactionGeneratorConfiguration = { | |
286 | enable: boolean | |
287 | minDuration: number | |
288 | maxDuration: number | |
289 | minDelayBetweenTwoTransactions: number | |
290 | maxDelayBetweenTwoTransactions: number | |
291 | probabilityOfStart: number | |
292 | stopAfterHours: number | |
293 | stopAbsoluteDuration: boolean | |
294 | requireAuthorize?: boolean | |
295 | idTagDistribution?: 'random' | 'round-robin' | 'connector-affinity' | |
296 | } | |
297 | ``` | |
298 | ||
299 | ##### Example: | |
300 | ||
301 | ```json | |
302 | "AutomaticTransactionGenerator": { | |
303 | "enable": false, | |
304 | "minDuration": 60, | |
305 | "maxDuration": 80, | |
306 | "minDelayBetweenTwoTransactions": 15, | |
307 | "maxDelayBetweenTwoTransactions": 30, | |
308 | "probabilityOfStart": 1, | |
309 | "stopAfterHours": 0.3, | |
310 | "requireAuthorize": true, | |
311 | "idTagDistribution": "random" | |
312 | } | |
313 | ``` | |
314 | ||
315 | #### Connectors section syntax example | |
316 | ||
317 | ```json | |
318 | "Connectors": { | |
319 | "0": {}, | |
320 | "1": { | |
321 | "bootStatus": "Available", | |
322 | "MeterValues": [ | |
323 | ... | |
324 | { | |
325 | "unit": "W", | |
326 | "measurand": "Power.Active.Import", | |
327 | "phase": "L1-N", | |
328 | "value": "5000", | |
329 | "fluctuationPercent": "10" | |
330 | }, | |
331 | ... | |
332 | { | |
333 | "unit": "A", | |
334 | "measurand": "Current.Import", | |
335 | "minimum": "0.5" | |
336 | }, | |
337 | ... | |
338 | { | |
339 | "unit": "Wh" | |
340 | }, | |
341 | ... | |
342 | ] | |
343 | } | |
344 | }, | |
345 | ``` | |
346 | ||
347 | #### Evses section syntax example | |
348 | ||
349 | ```json | |
350 | "Evses": { | |
351 | "0": { | |
352 | "Connectors": { | |
353 | "0": {} | |
354 | } | |
355 | }, | |
356 | "1": { | |
357 | "Connectors": { | |
358 | "1": { | |
359 | "bootStatus": "Available", | |
360 | "MeterValues": [ | |
361 | ... | |
362 | { | |
363 | "unit": "W", | |
364 | "measurand": "Power.Active.Import", | |
365 | "phase": "L1-N", | |
366 | "value": "5000", | |
367 | "fluctuationPercent": "10" | |
368 | }, | |
369 | ... | |
370 | { | |
371 | "unit": "A", | |
372 | "measurand": "Current.Import", | |
373 | "minimum": "0.5" | |
374 | }, | |
375 | ... | |
376 | { | |
377 | "unit": "Wh" | |
378 | }, | |
379 | ... | |
380 | ] | |
381 | } | |
382 | } | |
383 | } | |
384 | }, | |
385 | ``` | |
386 | ||
387 | ### Charging station configuration | |
388 | ||
389 | **dist/assets/configurations/\<hashId\>.json**: | |
390 | ||
391 | The charging station configuration file is automatically generated at startup from the charging station configuration template file and is persistent. | |
392 | ||
393 | The charging station configuration file content can be regenerated partially on matching charging station configuration template file changes. The charging station serial number is kept unchanged. | |
394 | ||
395 | #### stationInfo section (optional) | |
396 | ||
397 | The syntax is similar to charging station configuration template with some added fields like the charging station id (name) and the 'Configuration' section removed. | |
398 | ||
399 | That section is overwritten on matching charging station configuration template file changes. | |
400 | ||
401 | #### connectorsStatus section | |
402 | ||
403 | The syntax is similar to charging station configuration template 'Connectors' section with some added fields. | |
404 | ||
405 | That section is overwritten on matching charging station configuration template file changes. | |
406 | ||
407 | #### evsesStatus section | |
408 | ||
409 | The syntax is similar to charging station configuration template 'Evses' section with some added fields. | |
410 | ||
411 | That section is overwritten on matching charging station configuration template file changes. | |
412 | ||
413 | #### automaticTransactionGenerator section (optional) | |
414 | ||
415 | The syntax is similar to the charging station configuration template 'AutomaticTransactionGenerator' section. | |
416 | ||
417 | That section is overwritten on matching charging station configuration template file changes. | |
418 | ||
419 | #### automaticTransactionGeneratorStatuses section | |
420 | ||
421 | That section is not overwritten on matching charging station configuration template file changes. | |
422 | ||
423 | #### configurationKey section (optional) | |
424 | ||
425 | The syntax is similar to the charging station configuration template 'Configuration' section. | |
426 | ||
427 | That section is not overwritten on matching charging station configuration template file changes. | |
428 | ||
429 | ## Docker | |
430 | ||
431 | In the [docker](./docker) folder: | |
432 | ||
433 | ```shell | |
434 | make | |
435 | ``` | |
436 | ||
437 | <!-- Or with the optional git submodules: | |
438 | ||
439 | ```shell | |
440 | make SUBMODULES_INIT=true | |
441 | ``` --> | |
442 | ||
443 | ## OCPP-J commands supported | |
444 | ||
445 | ### Version 1.6 | |
446 | ||
447 | #### Core Profile | |
448 | ||
449 | - :white_check_mark: Authorize | |
450 | - :white_check_mark: BootNotification | |
451 | - :white_check_mark: ChangeAvailability | |
452 | - :white_check_mark: ChangeConfiguration | |
453 | - :white_check_mark: ClearCache | |
454 | - :white_check_mark: DataTransfer | |
455 | - :white_check_mark: GetConfiguration | |
456 | - :white_check_mark: Heartbeat | |
457 | - :white_check_mark: MeterValues | |
458 | - :white_check_mark: RemoteStartTransaction | |
459 | - :white_check_mark: RemoteStopTransaction | |
460 | - :white_check_mark: Reset | |
461 | - :white_check_mark: StartTransaction | |
462 | - :white_check_mark: StatusNotification | |
463 | - :white_check_mark: StopTransaction | |
464 | - :white_check_mark: UnlockConnector | |
465 | ||
466 | #### Firmware Management Profile | |
467 | ||
468 | - :white_check_mark: GetDiagnostics | |
469 | - :white_check_mark: DiagnosticsStatusNotification | |
470 | - :white_check_mark: FirmwareStatusNotification | |
471 | - :white_check_mark: UpdateFirmware | |
472 | ||
473 | #### Local Auth List Management Profile | |
474 | ||
475 | - :x: GetLocalListVersion | |
476 | - :x: SendLocalList | |
477 | ||
478 | #### Reservation Profile | |
479 | ||
480 | - :white_check_mark: CancelReservation | |
481 | - :white_check_mark: ReserveNow | |
482 | ||
483 | #### Smart Charging Profile | |
484 | ||
485 | - :white_check_mark: ClearChargingProfile | |
486 | - :white_check_mark: GetCompositeSchedule | |
487 | - :white_check_mark: SetChargingProfile | |
488 | ||
489 | #### Remote Trigger Profile | |
490 | ||
491 | - :white_check_mark: TriggerMessage | |
492 | ||
493 | ### Version 2.x.x | |
494 | ||
495 | #### Provisioning | |
496 | ||
497 | - :white_check_mark: BootNotification | |
498 | ||
499 | #### Authorization | |
500 | ||
501 | - :white_check_mark: ClearCache | |
502 | ||
503 | #### Availability | |
504 | ||
505 | - :white_check_mark: StatusNotification | |
506 | - :white_check_mark: Heartbeat | |
507 | ||
508 | ## OCPP-J standard parameters supported | |
509 | ||
510 | All kind of OCPP parameters are supported in charging station configuration or charging station configuration template file. The list here mention the standard ones also handled automatically in the simulator. | |
511 | ||
512 | ### Version 1.6 | |
513 | ||
514 | #### Core Profile | |
515 | ||
516 | - :white_check_mark: AuthorizeRemoteTxRequests (type: boolean) (units: -) | |
517 | - :x: ClockAlignedDataInterval (type: integer) (units: seconds) | |
518 | - :white_check_mark: ConnectionTimeOut (type: integer) (units: seconds) | |
519 | - :x: GetConfigurationMaxKeys (type: integer) (units: -) | |
520 | - :white_check_mark: HeartbeatInterval (type: integer) (units: seconds) | |
521 | - :x: LocalAuthorizeOffline (type: boolean) (units: -) | |
522 | - :x: LocalPreAuthorize (type: boolean) (units: -) | |
523 | - :x: MeterValuesAlignedData (type: CSL) (units: -) | |
524 | - :white_check_mark: MeterValuesSampledData (type: CSL) (units: -) | |
525 | - :white_check_mark: MeterValueSampleInterval (type: integer) (units: seconds) | |
526 | - :white_check_mark: NumberOfConnectors (type: integer) (units: -) | |
527 | - :x: ResetRetries (type: integer) (units: times) | |
528 | - :white_check_mark: ConnectorPhaseRotation (type: CSL) (units: -) | |
529 | - :x: StopTransactionOnEVSideDisconnect (type: boolean) (units: -) | |
530 | - :x: StopTransactionOnInvalidId (type: boolean) (units: -) | |
531 | - :x: StopTxnAlignedData (type: CSL) (units: -) | |
532 | - :x: StopTxnSampledData (type: CSL) (units: -) | |
533 | - :white_check_mark: SupportedFeatureProfiles (type: CSL) (units: -) | |
534 | - :x: TransactionMessageAttempts (type: integer) (units: times) | |
535 | - :x: TransactionMessageRetryInterval (type: integer) (units: seconds) | |
536 | - :x: UnlockConnectorOnEVSideDisconnect (type: boolean) (units: -) | |
537 | - :white_check_mark: WebSocketPingInterval (type: integer) (units: seconds) | |
538 | ||
539 | #### Firmware Management Profile | |
540 | ||
541 | - _none_ | |
542 | ||
543 | #### Local Auth List Management Profile | |
544 | ||
545 | - :white_check_mark: LocalAuthListEnabled (type: boolean) (units: -) | |
546 | - :x: LocalAuthListMaxLength (type: integer) (units: -) | |
547 | - :x: SendLocalListMaxLength (type: integer) (units: -) | |
548 | ||
549 | #### Reservation Profile | |
550 | ||
551 | - :white_check_mark: ReserveConnectorZeroSupported (type: boolean) (units: -) | |
552 | ||
553 | #### Smart Charging Profile | |
554 | ||
555 | - :x: ChargeProfileMaxStackLevel (type: integer) (units: -) | |
556 | - :x: ChargingScheduleAllowedChargingRateUnit (type: CSL) (units: -) | |
557 | - :x: ChargingScheduleMaxPeriods (type: integer) (units: -) | |
558 | - :x: MaxChargingProfilesInstalled (type: integer) (units: -) | |
559 | ||
560 | #### Remote Trigger Profile | |
561 | ||
562 | - _none_ | |
563 | ||
564 | ### Version 2.x.x | |
565 | ||
566 | ## UI Protocol | |
567 | ||
568 | Protocol to control the simulator via a Websocket or HTTP server: | |
569 | ||
570 | ```mermaid | |
571 | sequenceDiagram | |
572 | Client->>UI Server: request | |
573 | UI Server->>Client: response | |
574 | Note over UI Server,Client: HTTP or Websocket | |
575 | ``` | |
576 | ||
577 | ### Websocket Protocol | |
578 | ||
579 | SRPC protocol over Websocket. PDU stands for 'Protocol Data Unit'. | |
580 | ||
581 | - Request: | |
582 | [`uuid`, `ProcedureName`, `PDU`] | |
583 | `uuid`: String uniquely representing this request | |
584 | `ProcedureName`: The procedure to run on the simulator | |
585 | `PDU`: The parameters for said procedure | |
586 | ||
587 | - Response: | |
588 | [`uuid`, `PDU`] | |
589 | `uuid`: String uniquely linking the response to the request | |
590 | `PDU`: Response parameters to requested procedure | |
591 | ||
592 | To learn how to use the Websocket protocol to pilot the simulator, an [Insomnia](https://insomnia.rest/) Websocket requests collection is available in [src/assets/ui-protocol](./src/assets/ui-protocol) directory. | |
593 | ||
594 | #### Version 0.0.1 | |
595 | ||
596 | Set the Websocket header _Sec-Websocket-Protocol_ to `ui0.0.1`. | |
597 | ||
598 | ##### Procedures | |
599 | ||
600 | ###### Simulator State | |
601 | ||
602 | - Request: | |
603 | `ProcedureName`: 'simulatorState' | |
604 | `PDU`: {} | |
605 | ||
606 | - Response: | |
607 | `PDU`: { | |
608 | `status`: 'success' | 'failure', | |
609 | `state`: { | |
610 | `version`: string, | |
611 | `configuration`: ConfigurationData, | |
612 | `started`: boolean, | |
613 | `templateStatistics`: Record<string, TemplateStatistics> | |
614 | } | |
615 | } | |
616 | ||
617 | ###### Start Simulator | |
618 | ||
619 | - Request: | |
620 | `ProcedureName`: 'startSimulator' | |
621 | `PDU`: {} | |
622 | ||
623 | - Response: | |
624 | `PDU`: { | |
625 | `status`: 'success' | 'failure' | |
626 | } | |
627 | ||
628 | ###### Stop Simulator | |
629 | ||
630 | - Request: | |
631 | `ProcedureName`: 'stopSimulator' | |
632 | `PDU`: {} | |
633 | ||
634 | - Response: | |
635 | `PDU`: { | |
636 | `status`: 'success' | 'failure' | |
637 | } | |
638 | ||
639 | ###### List Charging Station Templates | |
640 | ||
641 | - Request: | |
642 | `ProcedureName`: 'listTemplates' | |
643 | `PDU`: {} | |
644 | ||
645 | - Response: | |
646 | `PDU`: { | |
647 | `status`: 'success' | 'failure', | |
648 | `templates`: string[] | |
649 | } | |
650 | ||
651 | ###### Add Charging Stations | |
652 | ||
653 | - Request: | |
654 | `ProcedureName`: 'addChargingStations' | |
655 | `PDU`: { | |
656 | `template`: string, | |
657 | `numberOfStations`: number, | |
658 | `options?`: { | |
659 | `supervisionUrls?`: string | string[], | |
660 | `persistentConfiguration?`: boolean, | |
661 | `autoStart?`: boolean, | |
662 | `autoRegister?`: boolean, | |
663 | `enableStatistics?`: boolean, | |
664 | `ocppStrictCompliance?`: boolean, | |
665 | `stopTransactionsOnStopped?`: boolean | |
666 | } | |
667 | } | |
668 | ||
669 | - Response: | |
670 | `PDU`: { | |
671 | `status`: 'success' | 'failure', | |
672 | `hashIdsSucceeded`: charging station unique identifier strings array (optional), | |
673 | `hashIdsFailed`: charging station unique identifier strings array (optional) | |
674 | } | |
675 | ||
676 | ###### Delete Charging Stations | |
677 | ||
678 | - Request: | |
679 | `ProcedureName`: 'deleteChargingStations' | |
680 | `PDU`: { | |
681 | `hashIds`: charging station unique identifier strings array (optional, default: all charging stations), | |
682 | `deleteConfiguration?`: boolean | |
683 | } | |
684 | ||
685 | - Response: | |
686 | `PDU`: { | |
687 | `status`: 'success' | 'failure', | |
688 | `hashIdsSucceeded`: charging station unique identifier strings array, | |
689 | `hashIdsFailed`: charging station unique identifier strings array (optional), | |
690 | `responsesFailed`: failed responses payload array (optional) | |
691 | } | |
692 | ||
693 | ###### Set Charging Station Supervision Url | |
694 | ||
695 | - Request: | |
696 | `ProcedureName`: 'setSupervisionUrl' | |
697 | `PDU`: { | |
698 | `hashIds`: charging station unique identifier strings array (optional, default: all charging stations), | |
699 | `url`: string | |
700 | } | |
701 | ||
702 | - Response: | |
703 | `PDU`: { | |
704 | `status`: 'success' | 'failure', | |
705 | `hashIdsSucceeded`: charging station unique identifier strings array, | |
706 | `hashIdsFailed`: charging station unique identifier strings array (optional), | |
707 | `responsesFailed`: failed responses payload array (optional) | |
708 | } | |
709 | ||
710 | ###### Performance Statistics | |
711 | ||
712 | - Request: | |
713 | `ProcedureName`: 'performanceStatistics' | |
714 | `PDU`: {} | |
715 | ||
716 | - Response: | |
717 | `PDU`: { | |
718 | `status`: 'success' | 'failure', | |
719 | `performanceStatistics`: Statistics[] | |
720 | } | |
721 | ||
722 | ###### List Charging Stations | |
723 | ||
724 | - Request: | |
725 | `ProcedureName`: 'listChargingStations' | |
726 | `PDU`: {} | |
727 | ||
728 | - Response: | |
729 | `PDU`: { | |
730 | `status`: 'success' | 'failure', | |
731 | `chargingStations`: ChargingStationData[] | |
732 | } | |
733 | ||
734 | ###### Start Charging Station | |
735 | ||
736 | - Request: | |
737 | `ProcedureName`: 'startChargingStation' | |
738 | `PDU`: { | |
739 | `hashIds`: charging station unique identifier strings array (optional, default: all charging stations) | |
740 | } | |
741 | ||
742 | - Response: | |
743 | `PDU`: { | |
744 | `status`: 'success' | 'failure', | |
745 | `hashIdsSucceeded`: charging station unique identifier strings array, | |
746 | `hashIdsFailed`: charging station unique identifier strings array (optional), | |
747 | `responsesFailed`: failed responses payload array (optional) | |
748 | } | |
749 | ||
750 | ###### Stop Charging Station | |
751 | ||
752 | - Request: | |
753 | `ProcedureName`: 'stopChargingStation' | |
754 | `PDU`: { | |
755 | `hashIds`: charging station unique identifier strings array (optional, default: all charging stations) | |
756 | } | |
757 | ||
758 | - Response: | |
759 | `PDU`: { | |
760 | `status`: 'success' | 'failure', | |
761 | `hashIdsSucceeded`: charging station unique identifier strings array, | |
762 | `hashIdsFailed`: charging station unique identifier strings array (optional), | |
763 | `responsesFailed`: failed responses payload array (optional) | |
764 | } | |
765 | ||
766 | ###### Open Connection | |
767 | ||
768 | - Request: | |
769 | `ProcedureName`: 'openConnection' | |
770 | `PDU`: { | |
771 | `hashIds`: charging station unique identifier strings array (optional, default: all charging stations) | |
772 | } | |
773 | ||
774 | - Response: | |
775 | `PDU`: { | |
776 | `status`: 'success' | 'failure', | |
777 | `hashIdsSucceeded`: charging station unique identifier strings array, | |
778 | `hashIdsFailed`: charging station unique identifier strings array (optional), | |
779 | `responsesFailed`: failed responses payload array (optional) | |
780 | } | |
781 | ||
782 | ###### Close Connection | |
783 | ||
784 | - Request: | |
785 | `ProcedureName`: 'closeConnection' | |
786 | `PDU`: { | |
787 | `hashIds`: charging station unique identifier strings array (optional, default: all charging stations) | |
788 | } | |
789 | ||
790 | - Response: | |
791 | `PDU`: { | |
792 | `status`: 'success' | 'failure', | |
793 | `hashIdsSucceeded`: charging station unique identifier strings array, | |
794 | `hashIdsFailed`: charging station unique identifier strings array (optional), | |
795 | `responsesFailed`: failed responses payload array (optional) | |
796 | } | |
797 | ||
798 | ###### Start Automatic Transaction Generator | |
799 | ||
800 | - Request: | |
801 | `ProcedureName`: 'startAutomaticTransactionGenerator' | |
802 | `PDU`: { | |
803 | `hashIds`: charging station unique identifier strings array (optional, default: all charging stations), | |
804 | `connectorIds`: connector id integer array (optional, default: all connectors) | |
805 | } | |
806 | ||
807 | - Response: | |
808 | `PDU`: { | |
809 | `status`: 'success' | 'failure', | |
810 | `hashIdsSucceeded`: charging station unique identifier strings array, | |
811 | `hashIdsFailed`: charging station unique identifier strings array (optional), | |
812 | `responsesFailed`: failed responses payload array (optional) | |
813 | } | |
814 | ||
815 | ###### Stop Automatic Transaction Generator | |
816 | ||
817 | - Request: | |
818 | `ProcedureName`: 'stopAutomaticTransactionGenerator' | |
819 | `PDU`: { | |
820 | `hashIds`: charging station unique identifier strings array (optional, default: all charging stations), | |
821 | `connectorIds`: connector id integer array (optional, default: all connectors) | |
822 | } | |
823 | ||
824 | - Response: | |
825 | `PDU`: { | |
826 | `status`: 'success' | 'failure', | |
827 | `hashIdsSucceeded`: charging station unique identifier strings array, | |
828 | `hashIdsFailed`: charging station unique identifier strings array (optional), | |
829 | `responsesFailed`: failed responses payload array (optional) | |
830 | } | |
831 | ||
832 | ###### OCPP commands trigger | |
833 | ||
834 | - Request: | |
835 | `ProcedureName`: 'commandName' (the OCPP command name in camel case) | |
836 | `PDU`: { | |
837 | `hashIds`: charging station unique identifier strings array (optional, default: all charging stations), | |
838 | ...`commandPayload` | |
839 | } (the OCPP command payload with some optional fields added to target the simulated charging stations) | |
840 | ||
841 | - Response: | |
842 | `PDU`: { | |
843 | `status`: 'success' | 'failure', | |
844 | `hashIdsSucceeded`: charging station unique identifier strings array, | |
845 | `hashIdsFailed`: charging station unique identifier strings array (optional), | |
846 | `responsesFailed`: failed responses payload array (optional) | |
847 | } | |
848 | ||
849 | Examples: | |
850 | ||
851 | - **Start Transaction** | |
852 | - Request: | |
853 | `ProcedureName`: 'startTransaction' | |
854 | `PDU`: { | |
855 | `hashIds`: charging station unique identifier strings array (optional, default: all charging stations), | |
856 | `connectorId`: connector id integer, | |
857 | `idTag`: RFID tag string | |
858 | } | |
859 | ||
860 | - Response: | |
861 | `PDU`: { | |
862 | `status`: 'success' | 'failure', | |
863 | `hashIdsSucceeded`: charging station unique identifier strings array, | |
864 | `hashIdsFailed`: charging station unique identifier strings array (optional), | |
865 | `responsesFailed`: failed responses payload array (optional) | |
866 | } | |
867 | ||
868 | - **Stop Transaction** | |
869 | - Request: | |
870 | `ProcedureName`: 'stopTransaction' | |
871 | `PDU`: { | |
872 | `hashIds`: charging station unique identifier strings array (optional, default: all charging stations), | |
873 | `transactionId`: transaction id integer | |
874 | } | |
875 | ||
876 | - Response: | |
877 | `PDU`: { | |
878 | `status`: 'success' | 'failure', | |
879 | `hashIdsSucceeded`: charging station unique identifier strings array, | |
880 | `hashIdsFailed`: charging station unique identifier strings array (optional), | |
881 | `responsesFailed`: failed responses payload array (optional) | |
882 | } | |
883 | ||
884 | - **Status Notification** | |
885 | - Request: | |
886 | `ProcedureName`: 'statusNotification' | |
887 | `PDU`: { | |
888 | `hashIds`: charging station unique identifier strings array (optional, default: all charging stations), | |
889 | `connectorId`: connector id integer, | |
890 | `errorCode`: connector error code, | |
891 | `status`: connector status | |
892 | } | |
893 | ||
894 | - Response: | |
895 | `PDU`: { | |
896 | `status`: 'success' | 'failure', | |
897 | `hashIdsSucceeded`: charging station unique identifier strings array, | |
898 | `hashIdsFailed`: charging station unique identifier strings array (optional), | |
899 | `responsesFailed`: failed responses payload array (optional) | |
900 | } | |
901 | ||
902 | - **Heartbeat** | |
903 | - Request: | |
904 | `ProcedureName`: 'heartbeat' | |
905 | `PDU`: { | |
906 | `hashIds`: charging station unique identifier strings array (optional, default: all charging stations) | |
907 | } | |
908 | ||
909 | - Response: | |
910 | `PDU`: { | |
911 | `status`: 'success' | 'failure', | |
912 | `hashIdsSucceeded`: charging station unique identifier strings array, | |
913 | `hashIdsFailed`: charging station unique identifier strings array (optional), | |
914 | `responsesFailed`: failed responses payload array (optional) | |
915 | } | |
916 | ||
917 | ### HTTP Protocol | |
918 | ||
919 | To learn how to use the HTTP protocol to pilot the simulator, an [Insomnia](https://insomnia.rest/) HTTP requests collection is available in [src/assets/ui-protocol](./src/assets/ui-protocol) directory. | |
920 | ||
921 | ## Support, Feedback, Contributing | |
922 | ||
923 | This project is open to feature requests/suggestions, bug reports etc. via [GitHub issues](https://github.com/SAP/e-mobility-charging-stations-simulator/issues). Contribution and feedback are encouraged and always welcome. For more information about how to contribute, the project structure, as well as additional contribution information, see our [Contribution Guidelines](./CONTRIBUTING.md). | |
924 | ||
925 | ## Code of Conduct | |
926 | ||
927 | We as members, contributors, and leaders pledge to make participation in our community a harassment-free experience for everyone. By participating in this project, you agree to abide by its [Code of Conduct](./CODE_OF_CONDUCT.md) at all times. | |
928 | ||
929 | ## Licensing | |
930 | ||
931 | Copyright 2020-2024 SAP SE or an SAP affiliate company and e-mobility-charging-stations-simulator contributors. Please see our [LICENSE](./LICENSE) for copyright and license information. Detailed information including third-party components and their licensing/copyright information is available [via the REUSE tool](https://api.reuse.software/info/github.com/SAP/e-mobility-charging-stations-simulator). |