1 libcec (2.0.3-1) unstable; urgency=low
4 * log unhandled vendor remote keycodes in the log, so they get logged
5 without debugging enabled
6 * double tap timeout increased from 200ms to 250ms
7 * CuBox/NXP* renamed to TDA995x*
9 * handling of active route changes. github issue #56 and issue #58
10 * new combo key handling broke samsung's vendor specific remote buttons.
12 * don't try to set controlled mode when using firmware version 1 and crash.
14 * fix for LG models that send a vendor key up after a normal key down.
16 * some TVs send keypresses to us without making us the active source. mark
17 us as active source when this happens. github issue #71
18 * LG doesn't send routing changes, and marks the TV as active source when
19 switching to another source that's not been selected in the simplink menu
20 instead. this change keeps libCEC marked as powered on and keep the deck
21 state set to CEC_DECK_INFO_OTHER_STATUS_LG. fixes keypresses not working
22 after switching to another source and back to libCEC's hdmi port via the
23 source select menu instead of the simplink menu. github issue #71
24 * don't respond with an abort message when receiving a vendor remote button
26 * respond with CEC_ABORT_REASON_INVALID_OPERAND when receiving a keypress
28 * typo in stop+pause combo key that prevented one of the keys from working
29 * rpi: log what data we received exactly when we receive an response from
30 the pi's firmware that doesn't match any command that we sent. issue #77
31 * cubox: added adapter ID interface
33 -- Pulse-Eight Packaging <packaging@pulse-eight.com> Wed, 31 Oct 2012 15:57:00 +0100
35 libcec (2.0.2-2) unstable; urgency=medium
38 * updating the device status after a poll was broken and could reset the
39 status of devices that were marked as handled by libCEC to 'not
41 * don't keep spamming the bus with a vendor command when an active source
42 switch is pending for panasonic, but only send it when needed
43 * reset CVLCommandHandler::m_bCapabilitiesSent when the TV goes to standby
45 -- Pulse-Eight Packaging <packaging@pulse-eight.com> Mon, 15 Oct 2012 13:52:00 +0100
47 libcec (2.0.2-1) unstable; urgency=low
50 * missing from the previous changelog: added support for the CuBox TDA995x
52 * lower retry timeout for source switches
53 * cec-client: wait for the source switch to finish when cec-client is
54 called with the -s switch
55 * request the power status of the TV directly after registering a new
58 * don't keep trying to send 'image view on' commands to the TV when no TV
59 is connected, and just send the 'set active source' command. fixes source
60 switch and debug log spam for people without a TV connected
61 * don't keep waiting for an updated power status from the TV for Panasonic,
62 but request a status update once every 5 seconds, or we can possibly wait
63 forever for the tv to send it
64 * log what we received exactly when logging FIXME
65 * typo in CVLCommandHandler::VendorPreActivateSourceHook. bugzid: 1087
66 * if we failed to get the physical address of the device that we are
67 connected to in the config, then try to use the address that was
68 persisted in the eeprom before resetting to the default value, 1.0.0.0.
70 * don't update the device status of unregistered/broadcast
71 * log all device status changes
72 * CCECClient::IsLibCECActiveSource returns false now while the active
73 source command is pending
74 * log failed acks and other errors in the debug log again
75 * don't send 'image view on' when the TV is already powering up
76 * reset the delayed source switch timeout properly, so we don't spam
78 * don't change the device status when sending a delayed source switch
79 * don't send out commands to a device that is marked as not present or
82 -- Pulse-Eight Packaging <packaging@pulse-eight.com> Thu, 11 Oct 2012 15:48:00 +0100
84 libcec (2.0.1-1) unstable; urgency=low
88 * added signal handlers to client applications
89 * Documentation updated
90 * replaced cec-config-gui by libCEC tray
91 * log the exact data for failed transmissions, not the opcode
92 * don't log every frame, unless debugging was enabled in ./configure or
94 * changed some log levels from NOTICE to DEBUG, so the non-debugging output
97 * WARNING: breaking API changes
98 * clean up: deprecated methods and fields removed
99 * callback parameters changed to fix plain C compilation
100 * added GetAdapterProductId()+GetAdapterVendorId()/
101 cec_get_adapter_product_id()+cec_get_adapter_vendor_id()
102 * added iDoubleTapTimeoutMs to libcec_configuration
103 * remove all pre-v2.0 compatibility checks
105 * fix plain C compilation
106 * prevent sending directly addressed commands from being sent to broadcast
107 * don't wait for a response when sending a reply, so we don't block message
109 * message response signaling and logging
110 * prevent double taps by not sending the same key press twice within 200ms
111 * fall back to the primary client when
112 CCECProcessor::HandleLogicalAddressLost() and no client could be found
113 * no more delay up to 2 seconds when exiting libCEC
114 * don't get caught in a loop in CVLCommandHandler when the source switch
115 was not allowed and no power status request was sent
116 * always send image view on to the tv, don't check the power status
117 * only respond to vendor commands for panasonic if we are the destination
118 * rpi: current firmware first sends a change to logical address 'broadcast'
119 and then signals us that the address was lost. libCEC then failed to
120 re-register, because it didn't know any client at this address
122 -- Pulse-Eight Packaging <packaging@pulse-eight.com> Mon, 8 Oct 2012 21:30:00 +0100
124 libcec (1.9.1-1) unstable; urgency=low
127 * added the type of adapter to libcec_configuration,
128 and display the type in cec-client -l
129 * added device detection support for composite usb devices on windows.
130 needs the windows ddk, and it's expected to be found in
131 C:\WinDDK\7600.16385.1
134 * adapter type was added to libcec_configuration
135 * moved cec_adapter_messagecode from cectypes.h to USBCECAdapterMessage.h
138 * retry m_port->Read(..) if an EINTR errror occurs instead of closing the
139 connection. credits @Obruni. closes #38
140 * make cec-client include cecloader.h from our project, not from system
141 * fixed duplicate entries check in CUSBCECAdapterDetection
142 * fixed missing cec_version updates in libcec_configuration
143 * transmit an active source message after <set stream path> to a device
144 that's handled by libCEC. closes #43
145 * rpi: handle vendor specific remote control presses. closes #42
146 * rpi: handle VC_CEC_LOGICAL_ADDR_LOST, sent by the Pi's firmware when
147 the logical address was taken while CEC was being reinitialised
148 * panasonic: send out an active source message when the tv started up
149 because it sometimes doesn't request this
151 -- Pulse-Eight Packaging <packaging@pulse-eight.com> Wed, 5 Sep 2012 16:54:00 +0100
153 libcec (1.8.2-1) unstable; urgency=low
156 * p8: match to the response provided by the firmware when checking
157 responses (added in firmware v2 rev6)
160 * windows: update the error message when an error occurs while writing to
162 * delayed source switch time was reset, resulting in an attempt every
163 second until it succeeded
164 * ensure that the vendor commands are always sent for panasonic, and that
165 the deck status for lg isn't reset. fixes some buttons not working after
166 a second or delayed source switch
167 * added guard so ReplaceHandler() doesn't accidently try to replace a
168 handler for the broadcast address
169 * wait until the commandhandler is replaced before registering a client,
170 so we don't register a client and replace it directly afterwards if the
171 tv doesn't support the device type
172 * ensure that the command handler of the tv is replaced before registering
173 a client, or it might result in a double eeprom write attempt
174 * p8: don't disable controlled mode when switching to monitoring mode
175 * p8: do delayed eeprom writes async or it'll block processing other input
177 -- Pulse-Eight Packaging <packaging@pulse-eight.com> Tue, 3 Aug 2012 02:35:00 +0100
179 libcec (1.8.1-1) unstable; urgency=low
182 * added support for the Raspberry Pi.
183 * added cec-client -i / cec-client --info that calls GetLibInfo()
185 * added CAdapterFactory, to create IAdapterCommunication instances
186 * added --debug to configure, to include -ggdb
189 * added GetLibInfo()/cec_get_lib_info(), that shows how libCEC was compiled
190 and with which features included.
191 * added ToString(cec_user_control_code_key) to the interface
194 * disallow sending CEC_OPCODE_SET_STREAM_PATH - not allowed by the CEC spec
195 * persist the configuration in the eeprom after initialising the client.
196 fixes wrong/old settings being used in autonomous mode, which broke the
198 * persist the new configuration when the hdmi port setting changed
199 * cleaned locks around callbacks
200 * always set controlled mode to false when unregistering the last client.
201 fixes 30 second timeout before controlled mode gets deactivated
202 * updated the cached device type setting properly when persisting new
203 settings. correct return value from WriteEEPROM(). lock a mutex when
205 * LibCecSharp: set the primary LA in CecLogicalAddresses
207 -- Pulse-Eight Packaging <packaging@pulse-eight.com> Tue, 25 Jul 2012 13:05:00 +0100
209 libcec (1.7.2-1) unstable; urgency=low
212 * display a warning message if libCEC was not compiled with adapter
213 detection for the target platform
214 * panasonic: added a vendor command for panasonic that will enable routing
215 of some more buttons on the remote (guide, text, ...)
216 * standby command won't be forwarded more than once every 10 seconds
217 * added vendor ids for Akai, AOC, Benq, Daewoo, Grundig, Medion, Sharp and
219 * cec-client: don't display debug output by default in 'cec-client -l'
222 * added a callback for clients that is called when a source is
223 (de)activated, so the client can respond to this action
224 * added cec_command::PushArray()
227 * command forwarding. fixes player not going into standby mode
228 * missing virtual keyword in CCECCommandHandler::
229 GetReplacementDeviceType()
230 * replace the handler (if needed) in GetHandler()
231 * reply with abort reason 'invalid operand' to vendor commands that we
233 * changed all Handle...() commands to return a cec_abort_reason and send
234 the correct abort reason to the initiator as a response to directly
236 * changed 'couldn't change the ackmask: the connection is closed' into a
238 * don't send active source commands when the physical address is invalid or
240 * set the power status of a device to 'powered on' after it sends a stream
241 path change. can save an unneeded power state update request
242 * removed dupe code around delayed activate source commands. check for
243 delayed active source commands every 5 seconds instead of 15 seconds.
244 * panasonic: reset m_bPowerUpEventReceived in CVLCommandHandler when the
245 device lets us know it went into standby mode. fixes possibly failed
246 active source switches after it succeeded once
247 * panasonic: fixed delayed source switch for panasonic
248 * panasonic: mark the tv as powered up once it sends the audiomode request
249 * set the physical address of each device controlled by a CCECClient if
251 * Windows could get stuck in a loop in case there an error occured while
252 reading registry entries
253 * ABI fixes (binary compat with v1.2 for Windows and v1.5.2 for others)
254 * replace the handler directly after getting the vendor id of a device when
256 * copy the class member values of the old handler when creating a new
257 command handler, or a delayed activate source will get lost when the
259 * cec-client: wrong client version
260 * Makefile cleanups. don't link cec-client and cec-config against libudev
262 * pin libcec to the same version as libcec1
263 * LibCecSharp: update the local configuration after connecting
264 * LibCecSharp: better handling of callbacks
266 -- Pulse-Eight Packaging <packaging@pulse-eight.com> Wed, 27 Jun 2012 02:06:00 +0100
268 libcec (1.7.1-1) unstable; urgency=low
271 * added physical address detection via ADL for AMD graphics cards
272 * attempt to get the edid from nvidia's graphics card driver on linux via
273 /proc/acpi/video/NGFX/HDMI/EDID
274 * attempt to get the PA from the registry on windows if we fail to get the
275 physical address from the display driver
276 * changed the order in CCECClient::SetPhysicalAddress() so it first checks
277 whether a PA override is set in libcec_configuration.iPhysicalAddress,
278 then checks whether the address can be detected, and if both failed it'll
279 use the HDMI port + base device setting
280 * cec-client: only active the source when reconnecting if libcec was the
281 active source before closing the connection
282 * platform: added tcp server sockets for posix
285 * libcec_configuration.bAutodetectAddress is now read-only, and will be set
286 to 1 by libCEC if the PA was autodetected
287 * LibCecSharp: don't use an int but a CecUserControlCode in a CecKeypress
290 * don't unregister clients in CLibCEC when disconnecting, but only in
291 CCECProcessor. fixes reconnect after close
292 * MSGCODE_TIMEOUT_ERROR is a response to a transmission
293 * retry 'activate source' every 10 seconds if it failed
294 * don't respond with a poll from the broadcast address when receiving
295 in CSLCommandHandler::HandleDeviceVendorId(), but use the primary LA of
296 the client as source instead
297 * hold a lock when changing the ackmask in
298 CUSBCECAdapterCommunication::Open
299 * don't respond with a feature abort to opcode play messages. bugzid: 873
300 * get the vendor id of the TV before allocating logical addresses, so we
301 can determine if the TV supports the requested device type directly
302 * TransmitImageViewOn() and TransmitActiveSource() always returned true,
303 even if sending the command failed, so the retry for failed source
304 activations was never triggered
305 * open libcec.so.1 instead of libcec.so in cecloader.h. credits @coling.
307 * fixed missing firmware version and build date in cec-client -l /
308 GetDeviceInformation()
310 -- Pulse-Eight Packaging <packaging@pulse-eight.com> Sun, 10 Jun 2012 13:39:00 +0100
312 libcec (1.6.1-5) unstable; urgency=low
314 * synced /debian directory with the one in precise (with a couple of changes)
316 * serial port locking on linux
317 * cec-client: added -m/--monitor startup options, which will start a
318 monitor-only client. use 'mon 0' to switch to a normal client
319 * display an alert message when the firmware of the adapter can be upgraded
320 * added CEC 1.4 opcodes
321 * send a feature abort again for all unhandled commands
322 * refactored CLibCEC so a client registers itself within CCECProcessor,
323 which then allocates one or more logical addresses for it.
326 * added a new setting, bMonitorOnly, which will start a monitor-only client
329 * ensure that we don't crash out when trying to stop a thread that hasn't
331 * don't send a 'disconnected' alert when the close method is called
332 * use the correct source when transmitting an abort message as a reposonse
333 to a vendor command with id
335 * check the client version, not the server version in
336 libcec_configuration::operator==()
337 * cec-config: fix physical address detection
338 * LibCecSharp: fixed buffer overrun when copying libcec_configuration.
339 fixes crash when trying to save the configuration in the config gui.
341 -- Pulse-Eight Packaging <packaging@pulse-eight.com> Mon, 14 May 2012 22:39:00 +0100
343 libcec (1.6.1-2) unstable; urgency=low
345 * Build depends on pkg-config. (Closes: #669919)
346 * libudev-dev only optionally needed for Linux.
348 -- Andres Mejia <amejia@debian.org> Sat, 21 Apr 2012 19:03:19 -0400
350 libcec (1.6.1-1) unstable; urgency=low
352 [ Mario Limonciello ]
353 * New upstream version (LP: #982272)
356 * New release fixes build failure with GCC-4.7. (Closes: #667241)
357 * Bump to Standards-Version 3.9.3.
359 -- Andres Mejia <amejia@debian.org> Sat, 21 Apr 2012 00:02:08 -0400
361 libcec (1.3.2-3) unstable; urgency=low
363 * Make dpkg-source options default for packaging.
365 -- Andres Mejia <amejia@debian.org> Tue, 10 Jan 2012 18:12:57 -0500
367 libcec (1.3.2-2) unstable; urgency=low
369 * Add options to pass to dpkg-source.
371 -- Andres Mejia <amejia@debian.org> Sun, 08 Jan 2012 22:59:34 -0500
373 libcec (1.3.2-1) unstable; urgency=low
375 * Initial release. (Closes: #655143)
377 -- Andres Mejia <amejia@debian.org> Sun, 08 Jan 2012 15:36:49 -0500
379 libcec (1.6-3) unstable; urgency=low
382 * cec-client: show the firmware build date if available in cec-client -l
383 * cec-client: don't activate the source when starting
384 * cec-client: group up the output of the 'scan' command, and add the
385 currently active source to the output
386 * log the libCEC version in the 'connected to the CEC adapter' log entry,
387 and add the firmware build date to the line if it's available, so all
388 relevant version info is available in 1 log line.
389 * async writes for CUSBCECAdapterCommunication. less locks and polls, more
391 * added 'make docs' target, that updates the doxygen documentation
394 * added operator == and != for libcec_configuration
395 * added GetResponseOpcode(cec_opcode opcode) to cec_command
396 * added the firmware build date to libcec_configuration, so it can be
397 displayed by the client too.
398 * added static CLibCEC::Alert() method and CEC_ALERT_CONNECTION_LOST value
399 * added a callback to handle menu state changes. if the callback method
400 returns 1, then the change is processed by the CCECBusDevice too. if 0,
401 then the CCECBusDevice will always have menu state 'activated', so
402 keypresses are routed. bugzid: 724
403 * added a default menu language to libcec_configuration and set this
404 language for devices controlled by libcec. bugzid: 69
407 * CCECProcessor::IsActiveSource() - TV was never checked
408 * don't call the deprecated SetActiveView() method in cec-client
409 * request the active source if unknown in CCECProcessor::GetActiveSource()
410 * don't try to match a device with PA 0xFFFF.
411 * don't change the power status of a device when changing the stream path
412 * don't set the power status to 'powered off' when marking the source
413 managed by libcec as inactive, or the tv will might send a power control
414 keycode when making it active again, potentially shutting down the system
415 * potential segfault in CCECProcessor::GetDeviceByPhysicalAddress()
416 * stream path changes when changed to the TV source (PA 0)
417 * clear the unsupported features list in CCECBusDevice::ResetDeviceStatus()
418 * never mark vendor commands as unsupported (only some may be unsupported),
419 as well as some others that should never be marked unsupported
420 * don't retry in CCECCommandHandler if the command has been marked as
422 * don't request the PA of devices when handling an incoming CEC command, or
423 it'll block things while waiting for a response. if that response never
424 comes, or comes late, then other incoming commands will be timed out
425 before they are handled
426 * optimisation - strip unneeded virtual keywords from top level
428 * use the vlcommandhandler for the primary device that is handled by libCEC
429 when a panasonic tv is detected, so delayed activate source commands are
430 using the correct handler. bugzid: 723
431 * set the power status of device controlled by libCEC to
433 instead of IN_TRANSITION_STANDBY_TO_ON. reset the device status of a
434 device if it was detected as removed. bugzid: 755
435 * potentially uninitialised values in cec_command
436 * delay the 'active source' command for panasonic, until the vendor command
437 that reports that the TV is powered on has been received. bugzid: 723
438 * only respond to Give Physical Address with Report Physical Address.
440 This fixes several reports of the TV improperly switching to the libcec
441 device after it has previously switched to another source. Fix confirmed
442 with Panasonic and also reported to be an issue with Samsung and
444 * check whether callback methods are set to a valid ptr
445 * number of retries for polls
446 * win32: fix build in paths with spaces. bugzid: 730
447 * LibCecSharp: free the alert GC callback when cleaning up
448 * the wrong setting was being read when powering on devices
449 * close the connection when a comm error was detected, and notify the
451 * don't segfault when calling ThreadsWait() without a valid thread
452 * lib/platform: fixed memleak
453 * leak in CCECAdapterMessageQueue::Write
454 * don't send commands if we know them to be unsupported. bugzid: 725
456 -- Pulse-Eight Packaging <packaging@pulse-eight.com> Wed, 18 Apr 2012 11:30:00 +0100
458 libcec (1.6-2) unstable; urgency=low
461 * fixed typo in CUSBCECAdapterCommands::RequestSettings() that prevented
462 the settings from being read. the settings were still written, but never
463 read when bGetSettingsFromROM = 1.
465 -- Pulse-Eight Packaging <packaging@pulse-eight.com> Wed, 18 Apr 2012 11:30:00 +0100
467 libcec (1.6-1) unstable; urgency=medium
470 * full firmware V2 support
471 * -o/--osdname argument for cec-client to set a custom osd name
472 * added the firmware version to cec-client's -l / --list-devices command.
474 * added power on command for Samsung AVR devices. bugzid: 361
475 * added buttoncode for 'channels list' on Samsung (0x96)
476 * don't check for the windows ddk when a prebuilt driver installer is
478 * respond to Get Menu Language. bugzid: 547. In the event that the menu
479 language is undefined in libcec (currently the default), the response
480 will be a feature abort.
483 * added the firmware version to libcec_configuration (read-only). bumped
484 server version to 1.6.0. fixed 'unknown server version' message on
486 * added a new setting to control whether to put the TV in standby when the
487 player is put in standby. added some missing bits (version numbers,
488 config) to LibCecSharp. bugzid: 558
489 * added an alert callback. bugzid: 462
490 * added bShutdownOnStandby to libcec_configuration. bugzid: 660. This
491 setting tells the client to shutdown when the TV switches off and is
492 complimentary to bPowerOffOnStandby, which tells the PC to suspend.
493 They are kept separate to maintain backwards compatability.
496 * gcc 4.7 compilation
497 * poll doesn't have an opcode. bugzid: 591
498 * wait for MSGEND when data was received when opening the connection.
500 * mark the correct device as active source after a stream path change.
501 if the new address is not found, but the old address is, then mark the
502 old address as inactive. fixes TV switching back to the old active source
503 when it scans for devices. bugzid: 592
504 * ensure that the vendor ID is sent before trying to activate any SL device
506 * fixed possible crash when in CLibCEC::IsLibCECActiveSource() when libCEC
507 doesn't know which device is the active source. bugzid: 479
508 * correct handling CEC_USER_CONTROL_CODE_POWER. This ensures that the power
509 code always operates as a toggle, depending on the current state, and
510 that SetCurrentButton is always called for a valid user control code.
512 * frequency wasn't checked in GetTimeMs(), leading to incorrect wait times
513 on some windows systems
514 * refactored USB adapter communication. less locks, shorter locks, added
515 documentation, lots of clean ups and no more incoming messages that are
517 * the destructor of CSerialSocket didn't call Close()
518 * added guards in CSerialPort
519 * reset m_socket to INVALID_SERIAL_SOCKET_VALUE after closing the
521 * always wait for thread exit in CThread's desctructor
522 * crash on exit after GetDeviceInformation()
523 * check whether the destination is valid before setting anything in
524 m_bWaitingForAck. fixes heap corruption and crash on exit. bugzid: 479
525 * bUseTVMenuLanguage from libcec_configuration wasn't copied in
526 SetConfiguration(), so this setting was reset to the default value
527 (enabled) every time. bugzid: 617
528 * request the vendor id of a device if needed when the device status is
529 changed into 'present'. bugzid: 361
530 * give priority to messages from the TV. removed the global lock in
531 CCECProcessor when sending. this is no longer needed. bugzid: 238
532 * add some bounds checking to the HDMI port number. bugzid: 508
533 * fixed usbser.sys copying in the driver .INF. bugzid: 503
534 * only update the physical address when it has actually changed. bugzid:
536 * moved the static variables in os-threads from the header to a separate
537 cpp file, or it could lead to problems when included multiple times
538 * don't send an active source command when the physical address couldn't be
539 set, or it might confuse other CEC devices
540 * serial socket timeouts. bugzid: 654
541 * fixed possible crash when trying to request a vendor id of a device when
542 the address of libCEC isn't known yet. bugzid: 654
543 * extra guard so no commands are transmitted without a valid initiator.
545 * moved the timed ping to a separate thread. bugzid: 654
546 * persist settings directly when they're changed, only persist settings
547 that actually changed, only instruct the device to persist the settings
548 in eeprom when something changed, and don't persist settings on exit.
550 * cec-config-gui: persist settings both in the eeprom and in the settings
552 * validate the input in CCECProcessor::IsActiveSource(). fixes potential
553 crash when the active source isn't known. bugzid: 671
555 -- Pulse-Eight Packaging <packaging@pulse-eight.com> Mon, 16 Apr 2012 18:03:00 +0100
557 libcec (1.5-4) unstable; urgency=low
560 * OS-X installation requirements and pointer
561 * full v2 firmware support:
562 * ping the adapter every 15 seconds. bugzid: 541
563 * added v2 msgcodes. bugzid: 543
564 * implemented the write methods for the v2 configuration. bugzid: 543
565 * included the logical addresses in the persisted configuration for v2.
567 * persist the configuration before closing the connection. only try to
568 persist the configuration when talking to a v2 firmware. bugzid: 543
569 * added GetSetting() to CUSBCECAdapterCommunication. bugzid: 543
570 * read the persisted settings from the ROM, and update it in
571 libcec_configuration if found. bugzid: 543
572 * cec-client: set bGetSettingsFromROM to 1 in cec-client. bugzid: 543
573 * cec-client: only read persisted EEPROM settings when -r or --rom is
574 provided as cmdline arg. bugzid: 543
575 * call SetControlledMode(false) as last command when closing the
576 connection in v2. bugzid: 542
577 * initial FreeBSD support: simply try to use ttyU*
580 * set controlled mode and retry to send the previous command if it failed
581 with MSGCODE_COMMAND_REJECTED
582 * m_iLineTimeout was never initialised and used. fixes MSGCODE_REJECTED
583 when transmitting a message and incorrect line timeouts being used
584 * mac configure compile bugzid: 157
585 * cec-config-gui: fixed application exit when the user clicked 'no' when
586 asked to reconnect. bugzid: 556
587 * only wait for multiple 'command accepted' response when sending a
588 transmit command, and only to 1 in other cases. bugzid: 543
589 * set the correct logical address mask before switching to autonomous mode.
591 * re-added SetLineTimeout(). bugzid: 543
592 * CUSBCECAdapterCommunication::SetControlledMode checked for the wrong sent
594 * os-x: don't add 0.5 before dividing in GetTimeMs()
595 * os-x: struct timespec now values weren't set correctly
597 -- Pulse-Eight Packaging <packaging@pulse-eight.com> Fri, 16 Mar 2012 10:12:00 +0100
599 libcec (1.5-3) unstable; urgency=low
603 * default to firmware version 1 after 3 tries. some versions didn't send a
605 * fixed cec-config win32 compilation
607 -- Pulse-Eight Packaging <packaging@pulse-eight.com> Sat, 03 Mar 2012 15:21:00 +0100
609 libcec (1.5-2) unstable; urgency=low
612 * added Toshiba's vendor id, and set the device ID of the primary device to
613 Toshiba's and transmit it when starting
614 * lock in SyncedBuffer
615 * added a timeout to StopThread()
616 * also add commands to unsupported features when receiving
617 CEC_ABORT_REASON_REFUSED
618 * cec-config-gui: set cbPortNumber enabled when the physical address
619 override isn't checked instead
620 * cec-config-gui: added support for the new 'send inactive source' setting
623 * added an 'send inactive source' option to libcec_configuration, only
624 supported by client/server 1.5.1 and up. bugzid: 439
625 * added a command to the interface to start the bootloader directly,
626 without going through all checks. bugzid: 218
627 * LibCecSharp: implemented support for the new 'send inactive source'
631 * don't send an updated configuration when libCEC hasn't been initialised
633 * don't send an updated configuration back when initialising. let the
634 client call the GetCurrentConfiguration() method. bugzid: 459
635 * configuration updates from libCEC. bugzid: 459
636 * fixed accidental double deref. the method parameter already does that.
638 * use CLOCK_MONOTONIC for timing info, since gettimeofday is affected by
639 ntp and by manually adjusting the system time
640 * the timeout value of pthread_cond_timedwait has to be referenced to
642 * don't add data to the input buffer in CUSBCECAdapterCommunication before
643 it's fully initialised
644 * fixed return value of CUSBCECAdapterCommunication::ParseMessage(). fixes
645 messages not being parsed in certain occasions
646 * don't try to transmit when the processor is being stopped
647 * set the server version in the LibCEC's constructor, since this is
648 checked by clients. fixes 'invalid libCEC version' popup when inserting
650 * don't wait for the full timeout to pass in CCECProcessor::
651 OpenConnection(), but retry to connect 2 times. fixes 'port busy' errors
652 when initialising libCEC. bugzid: 436
653 * use the correct Sleep() method in CCECProcessor::OpenConnection(). the
654 thread hasn't been started there yet, so the sleep wasn't working. fixes
655 'device or resource busy' when plugging in the adapter. bugzid: 436
656 * check the adapter ping and firmware before starting the reader thread, so
657 we really leave the com port alone for a second when it fails because of
658 a busy error. bugzid: 436
659 * ensure that the connection is really closed before retrying to connect.
661 * LibCecSharp: recreate the delegates properly when (re)connecting to
664 -- Pulse-Eight Packaging <packaging@pulse-eight.com> Tue, 28 Feb 2012 21:19:00 +0100
666 libcec (1.5-1) unstable; urgency=low
669 * a new libcec_configuration structs, which allows the client app to pass
670 a number of new options, like waking multiple devices on startup,
671 overriding the vendor id, etc.
672 * a new configuration GUI for Windows (.NET). this allows you to set
673 libCEC's configuration for XBMC in a convenient GUI.
674 * a CLI configuration tool (unfinished) for other platforms. will be
675 finished in an update.
676 * implemented power up for LG devices other than a TV
677 * win32: don't install libcec to the system directory by default, and
678 delete previous (testing) copies if present
679 * wait for multiple responses, not just for one at a time
680 * set the ackmask to 0 when closing the connection
681 * don't send 'image view on' when calling SetActiveSource()
682 * don't send power on, acitve source and standby commands by default in
684 * platform: added CTryLockObject
685 * platform: added an Init() method in CTimeout, so it can be reset
688 * added a new initialiser method: CecInitialise()/cec_initialise(), that
689 accepts a "libc_configuration" struct as parameter. this way, the
690 signature of the init method can stay the same when adding new options.
691 in LibCecSharp, the new method appears as a new constructor.
692 * added CanPersistConfiguration()/cec_can_persist_configuration()
693 * added PersistConfiguration()/cec_persist_configuration()
694 * added GetCurrentConfiguration()/cec_get_current_configuration()
695 * added SetConfiguration()/cec_set_configuration()
696 * added GetLogicalAddresses()/cec_get_logical_addresses(): returns the list
697 of addresses controlled by libCEC
698 * added RescanDevices()/cec_rescan_devices(): lets libCEC force polls to
699 all logical addresses.
700 * added a callback that is called when libCEC's configuration changed.
701 * moved the autodetect address api call to libcec_configuration. only send
702 power up commands to non-tv devices when the power state is not
703 on/transition->on. let players call the power up/power down command.
704 * return the anynet return keycode directly instead of translating it to
705 'return' for v1.5.0+ clients
706 * extracted CecSharpTypes.h in LibCecSharp. LibCecSharp is now in the
708 * include the local cectypes.h in cec.h and cecc.h instead of system wide
709 * deprecated GetLibVersion() methods. use libcec_configuration instead
710 * removed deprecated CECCreate() method
713 * fixed a lot of LG specific issues
714 * fixed OS-X compilation. credits: Dustin Cooper
715 * fixed a couple of possible deadlocks, e.g. when closing the connection
717 * cleaned up existing code
718 * libCEC no longer puts incoming data in a fifo buffer, but tries to
719 process it directly, which fixes issues like libCEC blocking processing
720 new commands while waiting for transmission acks.
721 * 'unsupported command' marking in CCECBusDevice
722 * ensure that the ackmask is always set to 0 when closing the connection
723 and that the call doesn't block the Close() call
724 * don't try to read or write in CUSBCECAdapterCommunication when the
725 connection has been closed
726 * LibCecSharp: added quotes to the linker statement for libcec.lib. fixes
727 compilation in paths with spaces. closes #20
728 * LibCecSharp: set the callback methods in libcec to NULL before closing
729 the connection, since these might already have been destroyed in .NET
730 * LibCecSharp: delete the internal callback struct when closing the
732 * LibCecSharp: pass correctly formatted logical address lists
733 * ensure that the vendor id is requested first when requesting info from a
734 device, so we are using the correct handler
735 * keep the 'busy state' of the command handler in CCECBusDevice
736 * poll the next device when the current is handled by libCEC.
737 * check the vendor id of a device before sending a power on command
738 * ensure that there always is at least one device type set
739 * transmit a keypress and key release as power on command when the target
741 * don't do a full reinit when not needed
742 * fix active source switches for the standard CEC implementation
743 * ensure that we don't send data to ourself
744 * check whether the port is open, not whether libCEC is initialised in
746 * platform: fixed return value from CCondition::Wait()
747 * platform: don't broadcast but wake one thread in
748 CProtectedSocket::MarkReady()
749 * platform: include stdint.h in windows/os-types.h instead of typedef'ing
751 * platform: fixed tcp socket error handling and return value.
752 * platform: fixed return values of socket operations in lib/platform
753 * platform: added predicate in CCondition
754 * deleted the signed driver from the tree, since that doesn't work. let the
755 installer create a new signed driver on the production build system
757 -- Pulse-Eight Packaging <packaging@pulse-eight.com> Mon, 19 Feb 2012 01:04:00 +0100
759 libcec (1.4-4) unstable; urgency=low
762 * added tcp client sockets to lib/platform (WIP)
763 * clean up lib/platform
764 * added: set controlled mode on after opening a connection to the adapter
766 * added an IAdapterCommunicationCallback interface an use a callback method
767 to pass newly received cec_commands to CCECProcessor
768 * added "driver only" and "driver + libcec" sections to the installer
769 * added a signed driver
770 * created a separate driver installer, which is included in the libCEC
771 installer. uninstalls the old unsigned version of libCEC and the driver
772 when it's found and installs the new one in C:\Program Files(x86)\
773 Pulse Eight\USB-CEC Adapter.
774 * don't sign development binaries with a temporary key. devs can do that
775 themselves when they want LibCecSharp in the GAC
777 * added SetStreamPath()/cec_set_stream_path_logical()/
778 cec_set_stream_path_physical() to the interface, to send a
779 "set stream path" command over the CEC bus, used to activate another
782 * transmit 'menu state activated' after the stream path has been set to a
783 device that is handled by libCEC. should fix remote commands not working
784 properly on Panasonic TVs and after another source has been active.
786 * set the ackmask to 0x0 when trying to find a free logical address
787 * keep trying to reconnect to the com port until the timeout runs out.
789 * wait 500 ms before trying to retransmit a command. always wait for the
790 result of a transmission in CCECCommandHandler::Transmit()
791 * receive and send full cec_commands, not CCECAdapterMessages in
792 CAdapterCommunication. extract an IAdapterCommunication interface. fixed
793 potentially missed data in CAdapterCommunication
794 * close and delete the connection when the processor thread ends. fixes
795 reconnect after standby (access denied / connection already opened)
796 * don't replace handlers when not initialised, or the primary device's
797 logical addres isn't known yet, which can lead to crashes. don't call
798 handlers directly in CCECProcessor without holding a lock on them
799 * fixed possible crash when command handler were switched while it was
801 * keep the mutex locked when calling ReplaceHandlers() in CCECProcessor
802 * win32: also timeout when data is received in SocketRead()
803 * win32: fixed < vista runtime and compilation
804 * win32: ping the adapter and request the firmware version in
805 CUSBCECAdapterCommunication instead of CCECProcesssor. fixes failed
807 * win32: fixed crash on exit in LibCecSharp
809 -- Pulse-Eight Packaging <packaging@pulse-eight.com> Mon, 6 Feb 2012 14:26:00 +0100
811 libcec (1.4-3) unstable; urgency=low
814 * try to ping the device and grab the firmware version until the connect
815 timeout runs out. fixes failed reconnect after standby, when the adapter
816 is still being initialised
818 -- Pulse-Eight Packaging <packaging@pulse-eight.com> Thu, 27 Jan 2012 13:05:00 +0100
820 libcec (1.4-2) unstable; urgency=low
823 * added a firmware flash script for linux.
824 usage: ./support/cec-flash-device.sh /path/to/firware.hex
825 * refactored threading/locking - added windows native instead of
826 pthread-win32, so we can compile native x64 too
827 * check whether the adapter responds when connecting to it and report the
828 firmware version of the adapter after connecting
829 * moved create-installer.cmd to support/
830 * completely removed AM_SILENT_RULES
832 * compile LibCecSharp against .NET framework 2.0 and sign the assembly
834 * only the key release events were sent, not keypresses, which appeared in
835 clients as laggy keypresses
836 * fixed reconnect after standby
837 * wait for active tranmission to finish when opening a connection to the
838 adapter. fixes initialisation errors
839 * set the default transmit timeout properly instead of using 0
840 * fixed possible deadlock because of a negative timeout in
841 CAdapterCommunication::WaitForTransmitSucceeded()
842 * fixed error message in cec-client (unable to open the device on port ...)
843 * exit cec-client after entering bootloader mode
844 * MSGCODE_START_BOOTLOADER doesn't respond with MSGCODE_COMMAND_ACCEPTED
846 -- Pulse-Eight Packaging <packaging@pulse-eight.com> Thu, 25 Jan 2012 23:28:00 +0100
848 libcec (1.4-1) unstable; urgency=low
851 * added the vendor id for Sony
852 * always refresh the power state of a device when it hasn't been updated
854 * do silent builds by default
856 * added optional callback methods to libCEC. enable them by calling
857 EnableCallbacks(ICECCallbacks *callbacks) /
858 cec_enable_callbacks(ICECCallbacks *callbacks). after this method is
859 called, the GetNext...() methods will not return any data
860 * added the same callbacks to LibCecSharp. implement CecCallbackMethods
861 and override the methods in there
863 * use the given timeout when trying to open a connection to the CEC
865 * resolved difference between method name in LibCECC.cpp and cecc.h.
866 credits: Doug Johnson
867 * don't transmit physical addresses while holding a lock in CCECProcessor
868 * don't hold a lock when sending an active source message.
869 * unload libCEC when the lib version is invalid
870 * "unused" warnings suppressed
872 -- Pulse-Eight Packaging <packaging@pulse-eight.com> Thu, 12 Jan 2012 19:06:00 +0100
874 libcec (1.3-3) unstable; urgency=low
877 * place in libudev include in an extern C block. fixes compilations on
878 older libudev versions (e.g. on Hardy). closes #2. credits @fbuenemann
879 * added pkg-config to the dependencies list. issue #15
880 * updated README. closes #14
881 * added a script that tests some basic functions of the CEC adapter:
882 /support/cec-test-device.sh
884 * don't make libCEC the active source when changing the physical address.
885 don't send active source messages on startup, when not the active source
886 fixes unwanted device power ups
887 * replace the command handler directly after receiving a changed vendor
888 id. change the primary type from recording device to playback device
890 * don't send a deck status update when sending an active source message
892 * only switch handlers once when using the generic handler
893 * don't switch handlers when not needed
894 * hold a lock in CCECProcessor::SetHDMIPort()
895 * don't send deck status updates when sending an active source message by
898 -- Pulse-Eight Packaging <packaging@pulse-eight.com> Thu, 3 Jan 2012 22:48:00 +0100
900 libcec (1.3-2) unstable; urgency=low
903 * copy libcec.dll to the XBMC installation dir when XBMC is found
904 * disable background polling. let the client request this info when needed
905 * update the power status of a device when it's set to
906 CEC_POWER_STATUS_IN_TRANSITION_STANDBY_TO_ON
907 * wait for the correct response when requesting something, not just any
909 * don't keep trying the same command/request after receiving a feature
912 * change the previously unused boolean parameter in volume control methods
913 to bSendRelease, and only send a key release when it's true. default to
916 * don't send the power up/down keypress to listeners when in the initial
917 device state (powered off). fixes unexpected shutdown in XBMC when
918 connecting to the CEC adapter.
919 * send a 'menu state activated' command when starting up. bugzid: 113
920 * don't wait for a response when not needed
921 * don't hold a lock while waiting for a response. fixes failed libCEC
922 inits and slow responses
923 * don't replace a command handler when it's being used. fixes possible
925 * don't try to do anything before the processor thread has started
926 * don't transmit active source messages when the physical address is
928 * don't init the default handler before the physical address is known
930 -- Pulse-Eight Packaging <packaging@pulse-eight.com> Thu, 29 Dec 2011 03:05:00 +0100
932 libcec (1.3-1) unstable; urgency=low
935 * make libudev optional. if libudev is not available on linux, adapter
936 autodetection will also not be available. fixes compilation on Hardy/ATV1
937 * added a C++ CLR wrapper for libCEC, so libCEC can be used by any .NET
939 * added vendor support for LG
940 * added vendor support for Philips
941 * added vendor support for Yamaha
942 * added vendor support for Onkyo
943 * added 'scan' command to cec-client, that displays info about devices on
944 the bus. made all ToString() methods available on the interface.
945 * added '-s' or '--single-command' to cec-client. starting cec-client with
946 this parameter executes a single command in cec-client and does not power
947 on devices on startup and power them off on exit. this way, you can use
948 cec-client in a shell script. since there's some handshaking involved at
949 startup, this is not very fast. to execute a command and only display the
950 result and any error/warning, execute it with
951 RESULT=`echo command | cec-client -s -d 3` (on linux/osx, win32 batch
952 files are a bit different)
953 * added HDMI port ('-p' or '--port') and base device ('-b' or '--base') to
954 cec-client's parameters
955 * handle image view on and text view on
956 * handle routing information and report physical address opcodes
957 * handle audio status updates
958 * send ping and bootloader commands via the output queue
959 * scan the CEC bus for devices when starting libcec
960 * pass all commands that are directed at libcec to listeners
962 * added GetActiveSource()/cec_get_active_source()
963 * added IsActiveSource()/cec_is_active_source()
964 * added GetDevicePhysicalAddress()/cec_get_device_physical_address()
965 * added GetDeviceOSDName()/cec_get_osd_name()
966 * added SendKeypress()/cec_send_keypress() and SendKeyRelease()/
967 cec_send_key_release()
968 * added VolumeUp()/cec_volume_up(), VolumeDown()/cec_volume_down(),
969 MuteAudio()/cec_mute_audio()
970 * added GetActiveDevices()/cec_get_active_devices(), IsActiveDevice()/
971 cec_is_active_device(), IsActiveDeviceType()/cec_is_active_device_type().
972 * added SetHDMIPort()/cec_set_hdmi_port(). devices are now detected on load
973 and when a device with the same physical address is detected, libcec will
974 use the selected hdmi port on that device. should fix source selection on
975 other devices, like an amplifier
976 * added a hook in libcec for physical address autodetection
978 * don't request the physical address from the tv (it's always 0x0000)
979 * set the proper ackmask before doing anything else
980 * don't unlock the transmit mutex in CCECProcessor while waiting for an
983 * refactor CEC read/write. keep a single lock for all writes, not one per
985 * ignore other data while waiting for a response
986 * retry failed tranmissions
987 * don't delete a message before it's been sent when starting the bootloader
988 * or when sending a ping
989 * fixed possible segfault when switching the command handler after a vendor
991 * handle audio opcodes correctly
992 * inactive source should be directly addressed at the TV
993 * don't report a changed physical address when it hasn't changed
994 * routing information sets the stream path, not the physical address
995 * don't scan the whole bus in CCECProcessor::IsActiveDeviceType()
996 * don't request the vendor id from devices that are handled by libcec
997 * mark device status as present when a command was received from a device
998 * always send a power on command in CCECBusDevice::PowerOn()
999 * don't request updates statusses unless needed
1000 * report physical address sends 3 parameters, not 2. check whether the
1001 device type is correct
1002 * devices can send vendor commands from other vendors, so don't assume the
1003 device is of a certain vendor when it sends commands with a vendor id
1004 * thread safety fixes. bugzid: 19
1005 * clear any previous input when opening a connection to the adapter.
1007 * use the correct source address in CSLCommandHandler::HandleVendorCommand()
1008 * uncorrected CEC_OPCODE_DEVICE_VENDOR_ID. closes #5
1009 * renamed enum methods. fixes potential macro collision with isset().
1011 * don't change the active device when receiving stream path changed
1012 messages. fixes wrong source selection when powering after the TV.
1014 -- Pulse-Eight Packaging <packaging@pulse-eight.com> Fri, 09 Dec 2011 12:16:00 +0100
1016 libcec (1.2-1) unstable; urgency=low
1019 * pass the deck_control command to libcec listeners
1020 * check whether the initiator is valid in CCECProcessor::ParseCommand().
1021 fixes possible segfault when parsing invalid data
1023 -- Pulse-Eight Packaging <packaging@pulse-eight.com> Sat, 12 Nov 2011 13:36:00 +0100
1025 libcec (1.1-3) unstable; urgency=low
1027 * fixed return value in CCECProcessor::SetStreamPath(), which prevented
1028 active source and menu state from being sent
1030 -- Pulse-Eight Packaging <packaging@pulse-eight.com> Fri, 11 Nov 2011 23:36:00 +0100
1032 libcec (1.1-2) unstable; urgency=low
1034 * forgot to update the headers to v1.1
1036 -- Pulse-Eight Packaging <packaging@pulse-eight.com> Fri, 11 Nov 2011 18:56:00 +0100
1038 libcec (1.1-1) unstable; urgency=low
1040 * interface changes:
1041 * added logical address autodetection and let libcec handle multiple types
1042 simultaniously. for logical address autodetection, you have to use
1043 CECInit()/cec_init_typed() instead of CECCreate()/cec_init()
1044 * added SetActiveSource()/cec_set_active_source() to the interface.
1045 deprecated SetActiveView()/cec_set_active_view()
1046 * added SetMenuState()
1047 * added PollDevice()/cec_poll_device()
1048 * removed duplicate method SetActiveSource() / SetActiveView()
1049 * added SetDeckControlMode() and SetDeckInfo()
1051 * added vendor detection for panasonic and broadcast active view and set
1052 menu state when a panasonic device sets the stream path. thanks for the
1054 * added vendor code for pioneer
1055 * osd string is 13 chars max. don't send more
1056 * send the correct cec version for each device
1057 * switch to panasonic specific cec implementation if a panasonic device was
1059 * send the correct device type in TransmitPhysicalAddress()
1060 * send a reply from the correct device when the stream path is requested
1061 * opcode 0x80 means the stream path changed, not the physical address
1062 * don't poll for a vendor ID in monitoring mode
1063 * fixed parameter parsing in SetVendorId()
1064 * buffer up commands that are received while waiting for an ack. only send
1065 'active source' message for the actual active source
1066 * win32: prepend the com port path with '\\.\', so com ports > 9 can be
1067 accessed. thanks smolesen
1068 * audio systems cannot be an active source, so don't transmit active
1069 source message from this device
1070 * only send 'active source' when powered on
1071 * only set the osd name for the primary device. use default values for
1073 * increase physical address with 0x100 per device
1074 * win32: removed unneeded afxres.h include in the resource files, which
1075 is not present when using studio express. thanks Ghuron
1077 * mark the active source as active and other devices as inactive
1078 * set the power status to 'on' when receiving CEC_USER_CONTROL_CODE_POWER
1079 * transmit the menu state as (active) when the stream path is set
1081 * changed copyright of boblight files with permission of the original
1083 * partial handling of audio related opcodes
1084 * more consistent log messages
1085 * set a device type and name for each CCECBusDevice
1086 * keep a power and menu state per device
1087 * renamed all Broadcast...() and Report...() methods to Transmit...()
1088 * renamed SetOSDString() to TransmitOSDString()
1089 * changed debug level of 'did not receive ack' from error to debug
1090 * only set the power status to 'on' for the primary device
1091 * moved method decriptions from cecc.h to cec.h
1092 * only send a power on command when a device isn't on already and set
1093 the power state to CEC_POWER_STATUS_IN_TRANSITION_STANDBY_TO_ON while
1095 * handle CEC_OPCODE_STANDBY
1096 * handle CEC_OPCODE_ACTIVE_SOURCE
1097 * always start in standby mode and let the tv (or other device) send the
1099 * renamed the last few enums
1100 * handle deck related opcodes.
1101 * added TransmitVendorId(), but only transmit the id if it's not set to 'unknown'
1103 -- Pulse-Eight Packaging <packaging@pulse-eight.com> Fri, 11 Nov 2011 17:42:00 +0100
1105 libcec (1.0-1) unstable; urgency=low
1107 * interface changes:
1108 * set lib interface version back to 1.0 and rename GetLibVersion() to
1109 GetLibVersionMajor() and GetMinVersion() to GetMinLibVersion()
1110 * added GetLibVersionMinor()/cec_get_lib_version_minor() and set the minor
1113 * samsung's vendor specific remote keypresses don't send key releases. added
1114 call to AddKey() directly after the keypress
1115 * always reset the button press time in CLibCEC::AddKey()
1116 * always wait for a signal in CCECProcessor::Transmit()
1118 * drop shared_ptr and use a normal pointer. removed boost dependency
1120 -- Pulse-Eight Packaging <packaging@pulse-eight.com> Fri, 04 Nov 2011 00:14:00 +0100
1122 libcec (0.8-2) unstable; urgency=low
1124 * added 'libboost-dev' to build deps
1126 -- Pulse-Eight Packaging <packaging@pulse-eight.com> Tue, 01 Nov 2011 23:31:00 +0100
1128 libcec (0.8-1) unstable; urgency=low
1130 * interface changes:
1131 * added GetDevicePowerStatus()/cec_get_device_power_status()
1132 * added GetDeviceVendorId()/cec_get_device_vendor_id()
1133 * added GetDeviceMenuLanguage()/cec_get_device_menu_language()
1134 * added GetDeviceCecVersion()/cec_get_device_cec_version()
1135 * added SwitchMonitoring()/cec_switch_monitoring() to the interface. when
1136 monitoring is enabled, the device will only log the data it received,
1137 but will not respond to any message
1138 * removed timeout parameter in Transmit() and included the ack timeout in
1139 the cec_command struct
1140 * made the vendor id -> vendor name translation available
1141 * made CEC_LOG levels powers of 2
1142 * introduced CEC_LOG_TRAFFIC log level
1144 * set the correct ackmask on startup
1145 * wait for ack while keeping a lock
1146 * wait for the processor thread to start before continueing on startup
1147 * wait for messages to be transmitted before continueing in
1148 CCECProcessor::Transmit()
1149 * only set the logical address once when it has changed
1150 * correct source for broadcast messages
1151 * win32: create Release type installer
1153 * make all reads and write in CAdapterCommunication go through buffers.
1154 * poll for a vendor ID of connected devices and switch to a non-standard
1155 CEC implementation if needed.
1156 * added vendor detection of Samsung and LG devices
1157 * handle samsung remote command 'return'
1159 * added -la and --logical-address to the command line params
1160 * added -d and --log-level params to cec-client
1161 * added -sf and --short-log-file, which only log the actual messages, not
1162 the level and timestamp
1163 * added -f and --log-file parameters to cec-client
1164 * added option to change the log level to cec-client
1166 -- Pulse-Eight Packaging <packaging@pulse-eight.com> Tue, 01 Nov 2011 22:58:00 +0100
1168 libcec (0.7-1) unstable; urgency=low
1170 * send a keypress with 0 duration when a key is pressed and with a duration
1171 set when it's released
1172 * added SetOSDString() to the interface (not supported by all tvs)
1173 * fixed: 'routing change' is a broadcast message. log routing changes, but
1174 don't send a 'set active view' message, so the active input won't be
1176 * log keypresses in the debug log
1177 * added 'pa' command to cec-client, to change the physical address
1178 * added SetPhysicalAddress()/cec_set_physical_address() to the interface, so
1179 the HDMI port number to use can be changed
1180 * fixed: put the message processing code from WaitForAck() in ParseMessage().
1181 fixes missing incoming message logging of non-data messages when not
1183 * added 'txn' command to cec-client. same as 'tx', but doesn't wait for ACK
1185 * fixed: set initiator and destination first in cec_command::push_back().
1186 fixes 'tx' command in cec-client
1187 * fixed: keep trying to connect while iTimeout isn't reached (default 10
1188 seconds). fixes exit with a 'permission denied' error when the device isn't
1189 ready yet. remove CEC_SETTLE_DOWN_TIME
1190 * fixed: don't call SetActiveView() when reporting the power status. fixes
1191 loop which causes some TVs to report failed connections
1192 * fixed: eom was not being parsed when receiving MSGCODE_FRAME_DATA. fixed.
1193 * fixed: add the device type as parameter when sending the physical address.
1195 * fixed: typo in libcec.pc.in
1196 * added optional strLib parameter to LoadLibCec(), so the location of the
1197 shared library can be specified
1198 * only link cec-client against ld. use AC_SEARCH_LIBS instead of AC_CHECK_LIB
1199 * use int instead of bool on the public C interface and remove stdbool.h include
1200 * renamed: CECExports.h => cec.h, CECExportsC.h => cecc.h, CECLoader.h =>
1201 cecloader.h, CECTypes.h => cectypes.h
1202 * updated debian package. split up libcec and libcec-dev
1203 * fixed: changed to use dlopen instead of static linkage. shuffled headers a
1204 bit. bumped interface to version 7
1205 * removed 'rt' from libraries. it's not needed (anymore)
1206 * fixed: reset the active view after a routing change. issue #1
1207 * fixed: changed attached license to be GPLv2 instead of GPLv3 this was an
1208 error as libCEC is licensed GPLv2 not GPLv3 thanks @garbear
1209 * added contributors link
1211 -- Pulse-Eight Packaging <packaging@pulse-eight.com> Fri, 14 Oct 2011 17:34:00 +0200
1213 libcec (0.6-1) unstable; urgency=low
1215 * bumped interface version to 6
1216 * fixed packet output (reporting the OSD name correctly now)
1217 * refactored packet structs: split up in cec commands and adapter messages
1219 * added Darwin support (thanks Davilla!)
1220 * fixed WaitForAck()
1221 * fixed possible deadlock when starting a new thread
1222 * implemented vendor id and device class parsing. full detection will follow
1223 * added "on" and "standby" commands to the test client
1224 * retransmit packets if needed
1225 * fix GetTimeMs() on linux
1226 * added timestamp to log messages
1228 -- Pulse-Eight Packaging <packaging@pulse-eight.com> Sun, 09 Oct 2011 15:15:00 +0200
1230 libcec (0.5-1) unstable; urgency=low
1232 * bumped interface version to 5
1233 * don't pass std::string and std::vector accross the interface
1234 * fixed heap corruption crashes on windows
1235 * fixed some memory leaks
1236 * reset all structs to default values before doing with them
1238 -- Pulse-Eight Packaging <packaging@pulse-eight.com> Fri, 07 Oct 2011 22:00:00 +0200
1240 libcec (0.4-3) unstable; urgency=low
1243 * fixed some threading related bugs
1244 * fixed deadlock on exit
1245 * fixed wrongly reported physical address
1247 -- Pulse-Eight Packaging <packaging@pulse-eight.com> Thu, 06 Oct 2011 00:19:00 +0200
1249 libcec (0.4-2) unstable; urgency=low
1251 * fixed int parameter sizes and some signed/unsigned warnings
1252 * check whether m_port isn't NULL in ReadFromDevice
1253 * stop the processor thread and delete the CSerialPort instance on exit
1254 * added mutex in CSerialPort
1255 * fix segfault on exit
1256 * renamed libPlatform -> platform.
1257 * stuck everything from libCEC in the CEC namespace to avoid namespace
1260 -- Pulse-Eight Packaging <packaging@pulse-eight.com> Tue, 04 Oct 2011 23:45:00 +0200
1262 libcec (0.4-1) unstable; urgency=low
1264 * bumped interface version to 4
1265 * timeout parameter removed from Close()/cec_close(). return type changed to
1267 * added cec_destroy() method
1268 * removed timeout parameter from Transmit()
1269 * change the default argument of PowerOnDevices() to CECDEVICE_TV
1270 * removed PowerOffDevices(). use StandbyDevices() instead
1271 * removed obsolete methods from the interface
1272 * fixed bug: pthread_cond_wait was called without the mutex locked
1273 * fixed possible deadlock: don't send messages and wait for an ack with the
1274 mutex locked in CCECParser
1275 * created a separate reader thread and fixed the 'lock timeout' bug
1276 * testclient: use CECDEVICE_TV instead of the default argument
1277 (CECDEVICE_BROADCAST) for PowerOnDevices() and PowerOffDevices()
1279 -- Pulse-Eight Packaging <packaging@pulse-eight.com> Tue, 04 Oct 2011 00:48:00 +0200
1281 libcec (0.3-1) unstable; urgency=low
1283 * added device detection support for Windows
1285 -- Pulse-Eight Packaging <packaging@pulse-eight.com> Sun, 02 Oct 2011 12:09:33 +0200
1287 libcec (0.2-1) unstable; urgency=low
1289 * added a Close() method to the interface
1290 * Added CEC command that were received by the adapter in a buffer that can be
1291 read by a client with GetNextCommand()/cec_get_next_command(). added a
1292 'help' command to the test client, that displays all available commands
1293 * Fixed setting the ackmask. deprecated SetAckMask()/cec_set_ack_mask(). use
1294 SetLogicalAddress()/cec_set_logical_address() instead. add 'la' command to
1295 the testclient to set the logical address of the cec adapter
1296 * Added optional logical and physical address parameters to
1297 LoadLibCec()/cec_init() on the interface. fixed wrongly placed namespace
1298 close tag in CECExports.h. updated interface documentation. bumped
1299 interface version to 2.
1300 * fixed hardcoded ackmask in SetAckMast(). set a shorter display name in the
1301 test client. the previous one was too long and being rejected
1303 -- Pulse-Eight Packaging <packaging@pulse-eight.com> Fri, 28 Sep 2011 01:33:00 +0200
1305 libcec (0.1-1) unstable; urgency=low
1307 * Initial release v0.1
1309 -- Pulse-Eight Packaging <packaging@pulse-eight.com> Wed, 28 Sep 2011 23:55:48 +0200