1 <!-- markdownlint-disable-file MD033 MD024 -->
3 # [e-mobility charging stations simulator](https://github.com/sap/e-mobility-charging-stations-simulator)
5 [![GitHub Clones](https://img.shields.io/badge/dynamic/json?color=brightgreen&label=Clone&query=count&url=https://gist.githubusercontent.com/jerome-benoit/c7c669b881d5b27dc0b44a639504ff93/raw/clone.json&logo=github)](https://github.com/SAP/e-mobility-charging-stations-simulator/graphs/traffic)
6 [![GitHub commit activity (main)](https://img.shields.io/github/commit-activity/m/SAP/e-mobility-charging-stations-simulator/main?color=brightgreen&logo=github)](https://github.com/SAP/e-mobility-charging-stations-simulator/graphs/commit-activity)
7 [![CI workflow](https://github.com/SAP/e-mobility-charging-stations-simulator/actions/workflows/ci.yml/badge.svg)](https://github.com/SAP/e-mobility-charging-stations-simulator/actions/workflows/ci.yml)
8 [![REUSE status](https://api.reuse.software/badge/github.com/SAP/e-mobility-charging-stations-simulator)](https://api.reuse.software/info/github.com/SAP/e-mobility-charging-stations-simulator)
12 Simple [node.js](https://nodejs.org/) software to simulate and scale a set of charging stations based on the OCPP-J protocol as part of [SAP e-Mobility](https://www.sap.com/products/scm/e-mobility.html) solution.
16 Install the [node.js](https://nodejs.org/) current LTS or superior version runtime environment:
20 - [Chocolatey](https://chocolatey.org/):
23 choco install -y nodejs
28 - [Homebrew](https://brew.sh/):
36 - [NodeSource](https://github.com/nodesource/distributions) Node.js Binary Distributions for all supported versions.
40 Enable corepack if not already done and install latest pnpm version:
44 corepack prepare pnpm@latest --activate
47 In the repository root, run the following command:
53 ## Initial configuration
55 Copy the configuration template file [src/assets/config-template.json](src/assets/config-template.json) to [src/assets/config.json](src/assets/config.json).
56 Copy the RFID tags template file [src/assets/idtags-template.json](src/assets/idtags-template.json) to [src/assets/idtags.json](src/assets/idtags.json).
58 Tweak them to your needs by following the section [configuration files syntax](README.md#configuration-files-syntax): OCPP server supervision URL(s), charging station templates, etc.
62 To start the program, run: `pnpm start`.
66 See Web UI [README.md](ui/web/README.md) for more information.
68 ## Configuration files syntax
70 All configuration files are in the JSON standard format.
72 **Configuration files locations**:
74 - charging stations simulator configuration: [src/assets/config.json](src/assets/config.json);
75 - charging station configuration templates: [src/assets/station-templates](src/assets/station-templates);
76 - charging station configurations: [dist/assets/configurations](dist/assets/configurations);
77 - charging station RFID tags lists: [src/assets](src/assets).
79 The charging stations simulator's configuration parameters must be within the `src/assets/config.json` file. A charging station simulator configuration template file is available at [src/assets/config-template.json](src/assets/config-template.json).
81 All charging station configuration templates are in the directory [src/assets/station-templates](src/assets/station-templates).
83 A list of RFID tags must be defined for the automatic transaction generator in a file with the default location and name: `src/assets/idtags.json`. A template file is available at [src/assets/idtags-template.json](src/assets/idtags-template.json).
85 **Configuration files hierarchy and priority**:
87 1. charging station configuration: [dist/assets/configurations](dist/assets/configurations);
88 2. charging station configuration template: [src/assets/station-templates](src/assets/station-templates);
89 3. charging stations simulator configuration: [src/assets/config.json](src/assets/config.json).
91 The charging stations simulator has an automatic configuration files reload feature at change for:
93 - charging stations simulator configuration;
94 - charging station configuration templates;
95 - charging station authorization RFID tags lists.
97 But the modifications to test have to be done to the files in the build target directory [dist/assets](dist/assets). Once the modifications are done, they have to be reported to the matching files in the build source directory [src/assets](src/assets) to ensure they will be taken into account at next build.
99 ### Charging stations simulator configuration
101 **src/assets/config.json**:
103 | Key | Value(s) | Default Value | Value type | Description |
104 | -------------------------- | -------------------------------------------- | ----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------- | ------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------ | ---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------- |
105 | supervisionUrls | | [] | string \| string[] | string or strings array containing global connection URIs to OCPP-J servers |
106 | supervisionUrlDistribution | round-robin/random/charging-station-affinity | charging-station-affinity | string | supervision urls distribution policy to simulated charging stations |
107 | log | | {<br />"enabled": true,<br />"file": "logs/combined.log",<br />"errorFile": "logs/error.log",<br />"statisticsInterval": 60,<br />"level": "info",<br />"console": false,<br />"format": "simple",<br />"rotate": true<br />} | {<br />enabled: boolean;<br />file: string;<br />errorFile: string;<br />statisticsInterval: number;<br />level: string;<br />console: boolean;<br />format: string;<br />rotate: boolean;<br />maxFiles: string \| number;<br />maxSize: string \| number;<br />} | Log configuration section:<br />- _enabled_: enable logging<br />- _file_: log file relative path<br />- _errorFile_: error log file relative path<br />- _statisticsInterval_: seconds between charging stations statistics output in the logs<br />- _level_: emerg/alert/crit/error/warning/notice/info/debug [winston](https://github.com/winstonjs/winston) logging level</br >- _console_: output logs on the console<br />- _format_: [winston](https://github.com/winstonjs/winston) log format<br />- _rotate_: enable daily log files rotation<br />- _maxFiles_: maximum number of log files: https://github.com/winstonjs/winston-daily-rotate-file#options<br />- _maxSize_: maximum size of log files in bytes, or units of kb, mb, and gb: https://github.com/winstonjs/winston-daily-rotate-file#options |
108 | worker | | {<br />"processType": "workerSet",<br />"startDelay": 500,<br />"elementStartDelay": 0,<br />"elementsPerWorker": 'auto',<br />"poolMinSize": 4,<br />"poolMaxSize": 16<br />} | {<br />processType: WorkerProcessType;<br />startDelay: number;<br />elementStartDelay: number;<br />elementsPerWorker: number \| 'auto' \| 'all';<br />poolMinSize: number;<br />poolMaxSize: number;<br />} | Worker configuration section:<br />- _processType_: worker threads process type (`workerSet`/`fixedPool`/`dynamicPool`)<br />- _startDelay_: milliseconds to wait at worker threads startup (only for `workerSet` worker threads process type)<br />- _elementStartDelay_: milliseconds to wait at charging station startup<br />- _elementsPerWorker_: number of charging stations per worker threads for the `workerSet` process type (`auto` means (number of stations) / (number of CPUs) \* 1.5 if (number of stations) > (number of CPUs), otherwise 1; `all` means a unique worker will run all charging stations)<br />- _poolMinSize_: worker threads pool minimum number of threads</br >- _poolMaxSize_: worker threads pool maximum number of threads<br />- _resourceLimits_: worker threads [resource limits](https://nodejs.org/api/worker_threads.html#new-workerfilename-options) object option |
109 | uiServer | | {<br />"enabled": false,<br />"type": "ws",<br />"version": "1.1",<br />"options": {<br />"host": "localhost",<br />"port": 8080<br />}<br />} | {<br />enabled: boolean;<br />type: ApplicationProtocol;<br />version: ApplicationProtocolVersion;<br />options: ServerOptions;<br />authentication: {<br />enabled: boolean;<br />type: AuthenticationType;<br />username: string;<br />password: string;<br />}<br />} | UI server configuration section:<br />- _enabled_: enable UI server<br />- _type_: 'http' or 'ws'<br />- _version_: HTTP version '1.1' or '2.0'<br />- _options_: node.js net module [listen options](https://nodejs.org/api/net.html#serverlistenoptions-callback) |
110 | performanceStorage | | {<br />"enabled": false,<br />"type": "jsonfile",<br />"uri": "file:///performance/performanceRecords.json"<br />} | {<br />enabled: boolean;<br />type: string;<br />uri: string;<br />} | Performance storage configuration section:<br />- _enabled_: enable performance storage<br />- _type_: 'jsonfile' or 'mongodb'<br />- _uri_: storage URI |
111 | stationTemplateUrls | | {}[] | {<br />file: string;<br />numberOfStations: number;<br />}[] | array of charging station configuration templates URIs configuration section (charging station configuration template file name and number of stations) |
113 #### Worker process model
116 Worker set executing each a fixed number (elementsPerWorker) of simulated charging stations from the total
119 Fixedly sized worker pool executing a fixed total number of simulated charging stations
121 - **dynamicPool** (experimental):
122 Dynamically sized worker pool executing a fixed total number of simulated charging stations
124 ### Charging station configuration template
126 **src/assets/station-templates/\<name\>.json**:
128 | Key | Value(s) | Default Value | Value type | Description |
129 | ---------------------------------------------------- | ------------- | ---------------------------------------------------------------------------------------------------------------------------------- | ------------------------------------------------------------------------------------------------------------------------------------------------------------------------ | ------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------ |
130 | supervisionUrls | | [] | string \| string[] | string or strings array containing connection URIs to OCPP-J servers |
131 | supervisionUser | | undefined | string | basic HTTP authentication user to OCPP-J server |
132 | supervisionPassword | | undefined | string | basic HTTP authentication password to OCPP-J server |
133 | supervisionUrlOcppConfiguration | true/false | false | boolean | allow supervision URL configuration via a vendor OCPP parameter key |
134 | supervisionUrlOcppKey | | 'ConnectionUrl' | string | the vendor string that will be used as a vendor OCPP parameter key to set the supervision URL |
135 | ocppVersion | 1.6/2.0/2.0.1 | 1.6 | string | OCPP version |
136 | ocppProtocol | json | json | string | OCPP protocol |
137 | ocppStrictCompliance | true/false | true | boolean | strict adherence to the OCPP version and protocol specifications with OCPP commands PDU validation against [OCA](https://www.openchargealliance.org/) JSON schemas |
138 | ocppPersistentConfiguration | true/false | true | boolean | enable persistent OCPP parameters storage by charging stations 'hashId'. The persistency is ensured by the charging stations configuration files in [dist/assets/configurations](dist/assets/configurations) |
139 | stationInfoPersistentConfiguration | true/false | true | boolean | enable persistent station information and specifications storage by charging stations 'hashId'. The persistency is ensured by the charging stations configuration files in [dist/assets/configurations](dist/assets/configurations) |
140 | automaticTransactionGeneratorPersistentConfiguration | true/false | true | boolean | enable persistent automatic transaction generator configuration storage by charging stations 'hashId'. The persistency is ensured by the charging stations configuration files in [dist/assets/configurations](dist/assets/configurations) |
141 | wsOptions | | {} | ClientOptions & ClientRequestArgs | [ws](https://github.com/websockets/ws) and node.js [http](https://nodejs.org/api/http.html) clients options intersection |
142 | idTagsFile | | undefined | string | RFID tags list file relative to [src/assets](src/assets) path |
143 | baseName | | undefined | string | base name to build charging stations id |
144 | nameSuffix | | undefined | string | name suffix to build charging stations id |
145 | fixedName | true/false | false | boolean | use the baseName as the charging stations unique name |
146 | chargePointModel | | undefined | string | charging stations model |
147 | chargePointVendor | | undefined | string | charging stations vendor |
148 | chargePointSerialNumberPrefix | | undefined | string | charge point serial number prefix |
149 | chargeBoxSerialNumberPrefix | | undefined | string | charge box serial number prefix (deprecated since OCPP 1.6) |
150 | firmwareVersionPattern | | Semantic versioning regular expression: https://semver.org/#is-there-a-suggested-regular-expression-regex-to-check-a-semver-string | string | charging stations firmware version pattern |
151 | firmwareVersion | | undefined | string | charging stations firmware version |
152 | power | | | float \| float[] | charging stations maximum power value(s) |
153 | powerSharedByConnectors | true/false | false | boolean | charging stations power shared by its connectors |
154 | powerUnit | W/kW | W | string | charging stations power unit |
155 | currentOutType | AC/DC | AC | string | charging stations current out type |
156 | voltageOut | | AC:230/DC:400 | integer | charging stations voltage out |
157 | numberOfPhases | 0/1/3 | AC:3/DC:0 | integer | charging stations number of phase(s) |
158 | numberOfConnectors | | | integer \| integer[] | charging stations number of connector(s) |
159 | useConnectorId0 | true/false | true | boolean | use connector id 0 definition from the charging station configuration template |
160 | randomConnectors | true/false | false | boolean | randomize runtime connector id affectation from the connector id definition in charging station configuration template |
161 | resetTime | | 60 | integer | seconds to wait before the charging stations come back at reset |
162 | autoRegister | true/false | false | boolean | set charging stations as registered at boot notification for testing purpose |
163 | autoReconnectMaxRetries | | -1 (unlimited) | integer | connection retries to the OCPP-J server |
164 | reconnectExponentialDelay | true/false | false | boolean | connection delay retry to the OCPP-J server |
165 | registrationMaxRetries | | -1 (unlimited) | integer | charging stations boot notification retries |
166 | amperageLimitationOcppKey | | undefined | string | charging stations OCPP parameter key used to set the amperage limit, per phase for each connector on AC and global for DC |
167 | amperageLimitationUnit | A/cA/dA/mA | A | string | charging stations amperage limit unit |
168 | enableStatistics | true/false | false | boolean | enable charging stations statistics |
169 | remoteAuthorization | true/false | true | boolean | enable RFID tags remote authorization |
170 | beginEndMeterValues | true/false | false | boolean | enable Transaction.{Begin,End} MeterValues |
171 | outOfOrderEndMeterValues | true/false | false | boolean | send Transaction.End MeterValues out of order. Need to relax OCPP specifications strict compliance ('ocppStrictCompliance' parameter) |
172 | meteringPerTransaction | true/false | true | boolean | enable metering history on a per transaction basis |
173 | transactionDataMeterValues | true/false | false | boolean | enable transaction data MeterValues at stop transaction |
174 | stopTransactionsOnStopped | true/false | true | boolean | enable stop transactions on charging station stop |
175 | mainVoltageMeterValues | true/false | true | boolean | include charging stations main voltage MeterValues on three phased charging stations |
176 | phaseLineToLineVoltageMeterValues | true/false | false | boolean | include charging stations line to line voltage MeterValues on three phased charging stations |
177 | customValueLimitationMeterValues | true/false | true | boolean | enable limitation on custom fluctuated value in MeterValues |
178 | firmwareUpgrade | | {<br />"versionUpgrade": {<br />"step": 1<br />},<br />"reset": true<br />} | {<br />versionUpgrade: {<br />patternGroup: number;<br />step: number;<br />};<br />reset: boolean;<br />failureStatus: 'DownloadFailed' \| 'InstallationFailed';<br />} | Configuration section for simulating firmware upgrade support. |
179 | commandsSupport | | {<br />"incomingCommands": {},<br />"outgoingCommands": {}<br />} | {<br /> incomingCommands: Record<IncomingRequestCommand, boolean>;<br />outgoingCommands?: Record<RequestCommand, boolean>;<br />} | Configuration section for OCPP commands support. Empty section or subsections means all implemented OCPP commands are supported |
180 | messageTriggerSupport | | {} | Record<MessageTrigger, boolean> | Configuration section for OCPP commands trigger support. Empty section means all implemented OCPP trigger commands are supported |
181 | Configuration | | | ChargingStationOcppConfiguration | charging stations OCPP parameters configuration section |
182 | AutomaticTransactionGenerator | | | AutomaticTransactionGeneratorConfiguration | charging stations ATG configuration section |
183 | Connectors | | | Record<string, ConnectorStatus> | charging stations connectors configuration section |
184 | Evses | | | Record<string, EvseTemplate> | charging stations EVSEs configuration section |
186 #### Configuration section syntax example
190 "configurationKey": [
193 "key": "StandardKey",
195 "value": "StandardValue",
203 "value": "VendorValue",
212 #### AutomaticTransactionGenerator section syntax example
214 ##### Type definition:
217 type AutomaticTransactionGeneratorConfiguration = {
221 minDelayBetweenTwoTransactions: number;
222 maxDelayBetweenTwoTransactions: number;
223 probabilityOfStart: number;
224 stopAfterHours: number;
225 stopOnConnectionFailure: boolean;
226 requireAuthorize?: boolean;
227 idTagDistribution?: 'random' | 'round-robin' | 'connector-affinity';
234 "AutomaticTransactionGenerator": {
238 "minDelayBetweenTwoTransactions": 15,
239 "maxDelayBetweenTwoTransactions": 30,
240 "probabilityOfStart": 1,
241 "stopAfterHours": 0.3,
242 "stopOnConnectionFailure": true,
243 "requireAuthorize": true,
244 "idTagDistribution": "random"
248 #### Connectors section syntax example
254 "bootStatus": "Available",
259 "measurand": "Power.Active.Import",
262 "fluctuationPercent": "10"
267 "measurand": "Current.Import",
280 #### Evses section syntax example
292 "bootStatus": "Available",
297 "measurand": "Power.Active.Import",
300 "fluctuationPercent": "10"
305 "measurand": "Current.Import",
320 ### Charging station configuration
322 **dist/assets/configurations/\<hashId\>.json**:
324 The charging station configuration file is automatically generated at startup from the charging station configuration template file and is persistent.
326 The charging station configuration file content can be regenerated partially on matching charging station configuration template file changes. The charging station serial number is kept unchanged.
328 #### stationInfo section
330 The syntax is similar to charging station configuration template with some added fields like the charging station id (name) and the 'Configuration' section removed.
332 #### configurationKey section
334 The syntax is similar to the charging station configuration template 'Configuration' section.
336 #### automaticTransactionGenerator section
338 The syntax is similar to the charging station configuration template 'AutomaticTransactionGenerator' section.
342 In the [docker](./docker) folder:
348 <!-- Or with the optional git submodules:
351 make SUBMODULES_INIT=true
354 ## OCPP-J commands supported
360 - :white_check_mark: Authorize
361 - :white_check_mark: BootNotification
362 - :white_check_mark: ChangeAvailability
363 - :white_check_mark: ChangeConfiguration
364 - :white_check_mark: ClearCache
365 - :white_check_mark: DataTransfer
366 - :white_check_mark: GetConfiguration
367 - :white_check_mark: Heartbeat
368 - :white_check_mark: MeterValues
369 - :white_check_mark: RemoteStartTransaction
370 - :white_check_mark: RemoteStopTransaction
371 - :white_check_mark: Reset
372 - :white_check_mark: StartTransaction
373 - :white_check_mark: StatusNotification
374 - :white_check_mark: StopTransaction
375 - :white_check_mark: UnlockConnector
377 #### Firmware Management Profile
379 - :white_check_mark: GetDiagnostics
380 - :white_check_mark: DiagnosticsStatusNotification
381 - :white_check_mark: FirmwareStatusNotification
382 - :white_check_mark: UpdateFirmware
384 #### Local Auth List Management Profile
386 - :x: GetLocalListVersion
389 #### Reservation Profile
391 - :white_check_mark: CancelReservation
392 - :white_check_mark: ReserveNow
394 #### Smart Charging Profile
396 - :white_check_mark: ClearChargingProfile
397 - :white_check_mark: GetCompositeSchedule
398 - :white_check_mark: SetChargingProfile
400 #### Remote Trigger Profile
402 - :white_check_mark: TriggerMessage
408 - :white_check_mark: BootNotification
412 - :white_check_mark: ClearCache
416 - :white_check_mark: StatusNotification
417 - :white_check_mark: Heartbeat
419 ## OCPP-J standard parameters supported
421 All kind of OCPP parameters are supported in charging station configuration or charging station configuration template file. The list here mention the standard ones also handled automatically in the simulator.
427 - :white_check_mark: AuthorizeRemoteTxRequests (type: boolean) (units: -)
428 - :x: ClockAlignedDataInterval (type: integer) (units: seconds)
429 - :white_check_mark: ConnectionTimeOut (type: integer) (units: seconds)
430 - :x: GetConfigurationMaxKeys (type: integer) (units: -)
431 - :white_check_mark: HeartbeatInterval (type: integer) (units: seconds)
432 - :x: LocalAuthorizeOffline (type: boolean) (units: -)
433 - :x: LocalPreAuthorize (type: boolean) (units: -)
434 - :x: MeterValuesAlignedData (type: CSL) (units: -)
435 - :white_check_mark: MeterValuesSampledData (type: CSL) (units: -)
436 - :white_check_mark: MeterValueSampleInterval (type: integer) (units: seconds)
437 - :white_check_mark: NumberOfConnectors (type: integer) (units: -)
438 - :x: ResetRetries (type: integer) (units: times)
439 - :white_check_mark: ConnectorPhaseRotation (type: CSL) (units: -)
440 - :x: StopTransactionOnEVSideDisconnect (type: boolean) (units: -)
441 - :x: StopTransactionOnInvalidId (type: boolean) (units: -)
442 - :x: StopTxnAlignedData (type: CSL) (units: -)
443 - :x: StopTxnSampledData (type: CSL) (units: -)
444 - :white_check_mark: SupportedFeatureProfiles (type: CSL) (units: -)
445 - :x: TransactionMessageAttempts (type: integer) (units: times)
446 - :x: TransactionMessageRetryInterval (type: integer) (units: seconds)
447 - :x: UnlockConnectorOnEVSideDisconnect (type: boolean) (units: -)
448 - :white_check_mark: WebSocketPingInterval (type: integer) (units: seconds)
450 #### Firmware Management Profile
454 #### Local Auth List Management Profile
456 - :white_check_mark: LocalAuthListEnabled (type: boolean) (units: -)
457 - :x: LocalAuthListMaxLength (type: integer) (units: -)
458 - :x: SendLocalListMaxLength (type: integer) (units: -)
460 #### Reservation Profile
462 - :white_check_mark: ReserveConnectorZeroSupported (type: boolean) (units: -)
464 #### Smart Charging Profile
466 - :x: ChargeProfileMaxStackLevel (type: integer) (units: -)
467 - :x: ChargingScheduleAllowedChargingRateUnit (type: CSL) (units: -)
468 - :x: ChargingScheduleMaxPeriods (type: integer) (units: -)
469 - :x: MaxChargingProfilesInstalled (type: integer) (units: -)
471 #### Remote Trigger Profile
479 Protocol to control the simulator via a Websocket or HTTP server.
483 To learn how to use the HTTP protocol to pilot the simulator, an [Insomnia](https://insomnia.rest/) HTTP requests collection is available in [src/assets/ui-protocol](./src/assets/ui-protocol) directory.
485 ### Websocket Protocol
487 SRPC protocol over Websocket. PDU stands for 'Protocol Data Unit'.
490 [`uuid`, `ProcedureName`, `PDU`]
491 `uuid`: String uniquely representing this request
492 `ProcedureName`: The procedure to run on the simulator
493 `PDU`: The parameters for said procedure
497 `uuid`: String uniquely linking the response to the request
498 `PDU`: Response parameters to requested procedure
500 An [Insomnia](https://insomnia.rest/) WebSocket requests collection is available in [src/assets/ui-protocol](./src/assets/ui-protocol) directory.
504 Set the Websocket header _Sec-Websocket-Protocol_ to `ui0.0.1`.
508 ###### Start Simulator
511 `ProcedureName`: 'startSimulator'
516 `status`: 'success' | 'failure'
519 ###### Stop Simulator
522 `ProcedureName`: 'stopSimulator'
527 `status`: 'success' | 'failure'
530 ###### List Charging Stations
533 `ProcedureName`: 'listChargingStations'
538 `status`: 'success' | 'failure',
539 `chargingStations`: ChargingStationData[]
542 ###### Start Charging Station
545 `ProcedureName`: 'startChargingStation'
547 `hashIds`: charging station unique identifier strings array (optional, default: all charging stations)
552 `status`: 'success' | 'failure',
553 `hashIdsSucceeded`: charging station unique identifier strings array,
554 `hashIdsFailed`: charging station unique identifier strings array (optional)
555 `responsesFailed`: failed responses payload array (optional)
558 ###### Stop Charging Station
561 `ProcedureName`: 'stopChargingStation'
563 `hashIds`: charging station unique identifier strings array (optional, default: all charging stations)
568 `status`: 'success' | 'failure',
569 `hashIdsSucceeded`: charging station unique identifier strings array,
570 `hashIdsFailed`: charging station unique identifier strings array (optional),
571 `responsesFailed`: failed responses payload array (optional)
574 ###### Open Connection
577 `ProcedureName`: 'openConnection'
579 `hashIds`: charging station unique identifier strings array (optional, default: all charging stations)
584 `status`: 'success' | 'failure',
585 `hashIdsSucceeded`: charging station unique identifier strings array,
586 `hashIdsFailed`: charging station unique identifier strings array (optional),
587 `responsesFailed`: failed responses payload array (optional)
590 ###### Close Connection
593 `ProcedureName`: 'closeConnection'
595 `hashIds`: charging station unique identifier strings array (optional, default: all charging stations)
600 `status`: 'success' | 'failure',
601 `hashIdsSucceeded`: charging station unique identifier strings array,
602 `hashIdsFailed`: charging station unique identifier strings array (optional),
603 `responsesFailed`: failed responses payload array (optional)
606 ###### Start Automatic Transaction Generator
609 `ProcedureName`: 'startAutomaticTransactionGenerator'
611 `hashIds`: charging station unique identifier strings array (optional, default: all charging stations),
612 `connectorIds`: connector id integer array (optional, default: all connectors)
617 `status`: 'success' | 'failure',
618 `hashIdsSucceeded`: charging station unique identifier strings array,
619 `hashIdsFailed`: charging station unique identifier strings array (optional),
620 `responsesFailed`: failed responses payload array (optional)
623 ###### Stop Automatic Transaction Generator
626 `ProcedureName`: 'stopAutomaticTransactionGenerator'
628 `hashIds`: charging station unique identifier strings array (optional, default: all charging stations),
629 `connectorIds`: connector id integer array (optional, default: all connectors)
634 `status`: 'success' | 'failure',
635 `hashIdsSucceeded`: charging station unique identifier strings array,
636 `hashIdsFailed`: charging station unique identifier strings array (optional),
637 `responsesFailed`: failed responses payload array (optional)
640 ###### OCPP commands trigger
643 `ProcedureName`: 'commandName' (the OCPP command name in camel case)
645 `hashIds`: charging station unique identifier strings array (optional, default: all charging stations),
647 } (the OCPP command payload with some optional fields added to target the simulated charging stations)
651 `status`: 'success' | 'failure',
652 `hashIdsSucceeded`: charging station unique identifier strings array,
653 `hashIdsFailed`: charging station unique identifier strings array (optional),
654 `responsesFailed`: failed responses payload array (optional)
659 - **Start Transaction**
662 `ProcedureName`: 'startTransaction'
664 `hashIds`: charging station unique identifier strings array (optional, default: all charging stations),
665 `connectorId`: connector id integer,
666 `idTag`: RFID tag string
671 `status`: 'success' | 'failure',
672 `hashIdsSucceeded`: charging station unique identifier strings array,
673 `hashIdsFailed`: charging station unique identifier strings array (optional),
674 `responsesFailed`: failed responses payload array (optional)
677 - **Stop Transaction**
680 `ProcedureName`: 'stopTransaction'
682 `hashIds`: charging station unique identifier strings array (optional, default: all charging stations),
683 `transactionId`: transaction id integer
688 `status`: 'success' | 'failure',
689 `hashIdsSucceeded`: charging station unique identifier strings array,
690 `hashIdsFailed`: charging station unique identifier strings array (optional),
691 `responsesFailed`: failed responses payload array (optional)
694 - **Status Notification**
697 `ProcedureName`: 'statusNotification'
699 `hashIds`: charging station unique identifier strings array (optional, default: all charging stations),
700 `connectorId`: connector id integer,
701 `errorCode`: connector error code,
702 `status`: connector status
707 `status`: 'success' | 'failure',
708 `hashIdsSucceeded`: charging station unique identifier strings array,
709 `hashIdsFailed`: charging station unique identifier strings array (optional),
710 `responsesFailed`: failed responses payload array (optional)
716 `ProcedureName`: 'heartbeat'
718 `hashIds`: charging station unique identifier strings array (optional, default: all charging stations),
723 `status`: 'success' | 'failure',
724 `hashIdsSucceeded`: charging station unique identifier strings array,
725 `hashIdsFailed`: charging station unique identifier strings array (optional),
726 `responsesFailed`: failed responses payload array (optional)
729 ## Support, Feedback, Contributing
731 This project is open to feature requests/suggestions, bug reports etc. via [GitHub issues](https://github.com/SAP/e-mobility-charging-stations-simulator/issues). Contribution and feedback are encouraged and always welcome. For more information about how to contribute, the project structure, as well as additional contribution information, see our [Contribution Guidelines](CONTRIBUTING.md).
735 We as members, contributors, and leaders pledge to make participation in our community a harassment-free experience for everyone. By participating in this project, you agree to abide by its [Code of Conduct](CODE_OF_CONDUCT.md) at all times.
739 Copyright 2020-2023 SAP SE or an SAP affiliate company and e-mobility-charging-stations-simulator contributors. Please see our [LICENSE](LICENSE) for copyright and license information. Detailed information including third-party components and their licensing/copyright information is available [via the REUSE tool](https://api.reuse.software/info/github.com/SAP/e-mobility-charging-stations-simulator).