1 # ev-simulator
2
3 ## Summary
4
5 Simple [node.js](https://nodejs.org/) program to simulate a set of charging stations based on the OCPP-J 1.6 protocol.
6
7 ## Configuration syntax
8
9 All configuration files are in the JSON standard format.
10
11 The program's global configuration parameters must be within the src/assets/config.json file. A configuration template file is available at [src/assets/config-template.json](src/assets/config-template.json).
12
13 All charging station templates are in the directory [src/assets/station-templates](src/assets/station-templates).
14
15 A list of RFID tags must be defined for the automatic transaction generator with the default location and name src/assets/authorization-tags.json. A template file is available at [src/assets/authorization-tags-template.json](src/assets/authorization-tags-template.json).
16
17 ### Global configuration
18
19 **src/assets/config.json**:
20
21 Key | Value(s) | Default Value | Value type | Description
22 --- | -------| --------------| ---------- | ------------
23 supervisionURLs | | [] | string[] | array of connection URIs to OCPP-J servers
24 distributeStationsToTenantsEqually | true/false | true | boolean | distribute charging stations uniformly to the OCPP-J servers
25 statisticsDisplayInterval | | 60 | integer | seconds between charging stations statistics output in the logs
26 workerProcess | workerSet/staticPool/dynamicPool | workerSet | string | worker threads process type
27 workerStartDelay | | 500 | integer | milliseconds to wait at charging station worker threads startup
28 workerPoolMinSize | | 4 | integer | worker threads pool minimum number of threads
29 workerPoolMaxSize | | 16 | integer | worker threads pool maximum number of threads
30 workerPoolStrategy | ROUND_ROBIN/LESS_RECENTLY_USED/... | [poolifier](https://github.com/poolifier/poolifier) default: ROUND_ROBBIN | string | worker threads pool [poolifier](https://github.com/poolifier/poolifier) worker choice strategy
31 chargingStationsPerWorker | | 1 | integer | number of charging stations per worker threads for the `workerSet` process type
32 logConsole | true/false | false | boolean | output logs on the console
33 logFormat | | simple | string | winston log format
34 logRotate | true/false | true | boolean | enable daily log files rotation
35 logMaxFiles | | 7 | integer | maximum number of log files to keep
36 logLevel | emerg/alert/crit/error/warning/notice/info/debug | info | string | winston logging level
37 logFile | | combined.log | string | log file relative path
38 logErrorFile | | error.log | string | error log file relative path
39 stationTemplateURLs | | {}[] | { file: string; numberOfStations: number; }[] | array of charging template file URIs
40
41 ### Charging station template
42
43 Key | Value(s) | Default Value | Value type | Description
44 --- | -------| --------------| ---------- | ------------
45 supervisionURL | | '' | string | connection URI to OCPP-J server
46 supervisionUser | | '' | string | basic HTTP authentication user to OCPP-J server
47 supervisionPassword | | '' | string | basic HTTP authentication password to OCPP-J server
48 ocppVersion | 1.6 | 1.6 | string | OCPP version
49 ocppProtocol | json | json | string | OCPP protocol
50 authorizationFile | | '' | string | RFID tags list file relative to src/assets path
51 baseName | | '' | string | base name to build charging stations name
52 nameSuffix | | '' | string | name suffix to build charging stations name
53 fixedName | true/false | false | boolean | use the baseName as the charging stations unique name
54 chargePointModel | | '' | string | charging stations model
55 chargePointVendor | | '' | string | charging stations vendor
56 chargeBoxSerialNumberPrefix | | '' | string | charging stations serial number prefix
57 firmwareVersion | | '' | string | charging stations firmware version
58 power | | | float\|float[] | charging stations maximum power value(s)
59 powerSharedByConnectors | true/false | false | boolean | charging stations power shared by its connectors
60 powerUnit | W/kW | W | string | charging stations power unit
61 currentOutType | AC/DC | AC | string | charging stations current out type
62 voltageOut | | AC:230/DC:400 | integer | charging stations voltage out
63 numberOfPhases | 0/1/3 | AC:3/DC:0 | integer | charging stations number of phase(s)
64 numberOfConnectors | | | integer\|integer[] | charging stations number of connector(s)
65 useConnectorId0 | true/false | true | boolean | use connector id 0 definition from the template
66 randomConnectors | true/false | false | boolean | randomize runtime connector id affectation from the connector id definition in template
67 resetTime | | 60 | integer | seconds to wait before the charging stations come back at reset
68 autoRegister | true/false | false | boolean | set the charging station as registered at boot notification for testing purpose
69 autoReconnectMaxRetries | | -1 (unlimited) | integer | connection retries to the OCPP-J server
70 reconnectExponentialDelay | true/false | false | boolean | connection delay retry to the OCPP-J server
71 registrationMaxRetries | | -1 (unlimited) | integer | charging stations boot notification retries
72 enableStatistics | true/false | true | boolean | enable charging stations statistics
73 mayAuthorizeAtRemoteStart | true/false | true | boolean | always send authorize at remote start transaction when AuthorizeRemoteTxRequests is enabled
74 beginEndMeterValues | true/false | false | boolean | enable Transaction.{Begin,End} MeterValues
75 outOfOrderEndMeterValues | true/false | false | boolean | send Transaction.End MeterValues out of order
76 meteringPerTransaction | true/false | true | boolean | enable metering history on a per transaction basis
77 transactionDataMeterValues | true/false | false | boolean | enable transaction data MeterValues at stop transaction
78 mainVoltageMeterValues | true/false | true | boolean | include charging station main voltage MeterValues on three phased charging stations
79 phaseLineToLineVoltageMeterValues | true/false | true | boolean | include charging station line to line voltage MeterValues on three phased charging stations
80 Configuration | | | ChargingStationConfiguration | charging stations OCPP configuration parameters
81 AutomaticTransactionGenerator | | | AutomaticTransactionGenerator | charging stations ATG configuration
82 Connectors | | | Connectors | charging stations connectors configuration
83
84 #### Configuration section
85
86 ```json
87 "Configuration": {
88 "configurationKey": [
89 ...
90 {
91 "key": "StandardKey",
92 "readonly": false,
93 "value": "StandardValue",
94 "visible": true,
95 "reboot": false
96 },
97 ...
98 {
99 "key": "VendorKey",
100 "readonly": false,
101 "value": "VendorValue",
102 "visible": false,
103 "reboot": true
104 },
105 ...
106 ]
107 }
108 ```
109
110 #### AutomaticTransactionGenerator section
111
112 ```json
113 "AutomaticTransactionGenerator": {
114 "enable": false,
115 "minDuration": 60,
116 "maxDuration": 80,
117 "minDelayBetweenTwoTransactions": 15,
118 "maxDelayBetweenTwoTransactions": 30,
119 "probabilityOfStart": 1,
120 "stopAfterHours": 0.3,
121 "stopOnConnectionFailure": true,
122 "requireAuthorize": true
123 }
124 ```
125 #### Connectors section
126
127 ```json
128 "Connectors": {
129 "0": {},
130 "1": {
131 "bootStatus": "Available",
132 "MeterValues": [
133 ...
134 {
135 "unit": "W",
136 "measurand": "Power.Active.Import",
137 "phase": "L1-N",
138 "value": "5000",
139 "fluctuationPercent": "10"
140 },
141 ...
142 {
143 "unit": "A",
144 "measurand": "Current.Import"
145 },
146 ...
147 {
148 "unit": "Wh"
149 },
150 ...
151 ]
152 }
153 },
154 ```
155
156 ## Start
157
158 To start the program, run: `npm start`.
159
160 ## Docker
161
162 In the [docker](./docker) folder:
163
164 ```bash
165 make
166 ```
167
168 Or without the optional git submodules:
169
170 ```bash
171 make SUBMODULES_INIT=false
172 ```
173
174 ## OCPP-J commands supported
175
176 ### Version 1.6
177
178 #### Core Profile
179
180 - :white_check_mark: Authorize
181 - :white_check_mark: BootNotification
182 - :white_check_mark: ChangeAvailability
183 - :white_check_mark: ChangeConfiguration
184 - :white_check_mark: ClearCache
185 - :x: DataTransfer
186 - :white_check_mark: GetConfiguration
187 - :white_check_mark: Heartbeat
188 - :white_check_mark: MeterValues
189 - :white_check_mark: RemoteStartTransaction
190 - :white_check_mark: RemoteStopTransaction
191 - :white_check_mark: Reset
192 - :white_check_mark: StartTransaction
193 - :white_check_mark: StatusNotification
194 - :white_check_mark: StopTransaction
195 - :white_check_mark: UnlockConnector
196
197 #### Firmware Management Profile
198
199 - :x: GetDiagnostics
200 - :x: DiagnosticsStatusNotification
201 - :x: FirmwareStatusNotification
202 - :x: UpdateFirmware
203
204 #### Local Auth List Management Profile
205
206 - :x: GetLocalListVersion
207 - :x: SendLocalList
208
209 #### Reservation Profile
210
211 - :x: CancelReservation
212 - :x: ReserveNow
213
214 #### Smart Charging Profile
215
216 - :white_check_mark: ClearChargingProfile
217 - :white_check_mark: GetCompositeSchedule
218 - :white_check_mark: SetChargingProfile
219
220 #### Remote Trigger Profile
221
222 - :x: TriggerMessage
223
224 ## OCPP-J standard parameters supported
225
226 All kind of OCPP parameters are supported in a charging station template. The list here mention the standard ones also handled automatically in the simulator.
227
228 ### Version 1.6
229
230 #### Core Profile
231
232 - :white_check_mark: AuthorizeRemoteTxRequests (type: boolean) (units: -)
233 - :x: ClockAlignedDataInterval (type: integer) (units: seconds)
234 - :white_check_mark: ConnectionTimeOut (type: integer) (units: seconds)
235 - :x: GetConfigurationMaxKeys (type: integer) (units: -)
236 - :white_check_mark: HeartbeatInterval (type: integer) (units: seconds)
237 - :x: LocalAuthorizeOffline (type: boolean) (units: -)
238 - :x: LocalPreAuthorize (type: boolean) (units: -)
239 - :x: MeterValuesAlignedData (type: CSL) (units: -)
240 - :white_check_mark: MeterValuesSampledData (type: CSL) (units: -)
241 - :white_check_mark: MeterValueSampleInterval (type: integer) (units: seconds)
242 - :white_check_mark: NumberOfConnectors (type: integer) (units: -)
243 - :x: ResetRetries (type: integer) (units: times)
244 - :white_check_mark: ConnectorPhaseRotation (type: CSL) (units: -)
245 - :x: StopTransactionOnEVSideDisconnect (type: boolean) (units: -)
246 - :x: StopTransactionOnInvalidId (type: boolean) (units: -)
247 - :x: StopTxnAlignedData (type: CSL) (units: -)
248 - :x: StopTxnSampledData (type: CSL) (units: -)
249 - :white_check_mark: SupportedFeatureProfiles (type: CSL) (units: -)
250 - :x: TransactionMessageAttempts (type: integer) (units: times)
251 - :x: TransactionMessageRetryInterval (type: integer) (units: seconds)
252 - :x: UnlockConnectorOnEVSideDisconnect (type: boolean) (units: -)
253 - :white_check_mark: WebSocketPingInterval (type: integer) (units: seconds)
254
255 #### Firmware Management Profile
256
257 - *none*
258
259 #### Local Auth List Management Profile
260
261 - :white_check_mark: LocalAuthListEnabled (type: boolean) (units: -)
262 - :x: LocalAuthListMaxLength (type: integer) (units: -)
263 - :x: SendLocalListMaxLength (type: integer) (units: -)
264
265 #### Reservation Profile
266
267 - *none*
268
269 #### Smart Charging Profile
270
271 - :x: ChargeProfileMaxStackLevel (type: integer) (units: -)
272 - :x: ChargingScheduleAllowedChargingRateUnit (type: CSL) (units: -)
273 - :x: ChargingScheduleMaxPeriods (type: integer) (units: -)
274 - :x: MaxChargingProfilesInstalled (type: integer) (units: -)
275
276 #### Remote Trigger Profile
277
278 - *none*
279
280 ## License
281