Document configuration files reload feature usage.
[e-mobility-charging-stations-simulator.git] / README.md
1 # [charging-stations-simulator](https://github.com/jerome-benoit/charging-stations-simulator)
2
3 ## Summary
4
5 Simple [node.js](https://nodejs.org/) program to simulate a set of charging stations based on the OCPP-J 1.6 protocol.
6
7 ## Prerequisites
8
9 ### Windows
10
11 * [Chocolatey](https://chocolatey.org/):
12
13 ```powershell
14 choco install -y nodejs-lts
15 ```
16
17 ### MacOSX
18
19 * [Homebrew](https://brew.sh/):
20
21 ```shell
22 brew install node@14
23 ```
24
25 ### GNU/Linux:
26
27 * [NodeSource](https://github.com/nodesource/distributions) Node.js Binary Distributions for version 14.X
28
29 ## Configuration syntax
30
31 All configuration files are in the JSON standard format.
32
33 The charging stations simulator's main configuration parameters must be within the `src/assets/config.json` file. A configuration template file is available at [src/assets/config-template.json](src/assets/config-template.json).
34
35 All charging station templates are in the directory [src/assets/station-templates](src/assets/station-templates).
36
37 A list of RFID tags must be defined for the automatic transaction generator with the default location and name `src/assets/authorization-tags.json`. A template file is available at [src/assets/authorization-tags-template.json](src/assets/authorization-tags-template.json).
38
39 The charging stations simulator have an automatic configuration files reload feature at change for:
40 * main configuration;
41 * charging station templates;
42 * authorization RFID tags.
43
44 But the modifications to test have to be done to the files in the build result directory [dist/assets](dist/assets). Once the modifications are finished, they have to be reported or copied to the matching files in the build source directory [src/assets](src/assets) to ensure they will be taken into account at next build.
45
46 ### Global configuration
47
48 **src/assets/config.json**:
49
50 Key | Value(s) | Default Value | Value type | Description
51 --- | -------| --------------| ---------- | ------------
52 supervisionURLs | | [] | string[] | array of connection URIs to OCPP-J servers
53 distributeStationsToTenantsEqually | true/false | true | boolean | distribute charging stations uniformly to the OCPP-J servers
54 workerProcess | workerSet/staticPool/dynamicPool | workerSet | string | worker threads process type
55 workerStartDelay | | 500 | integer | milliseconds to wait at charging station worker threads startup
56 workerPoolMinSize | | 4 | integer | worker threads pool minimum number of threads
57 workerPoolMaxSize | | 16 | integer | worker threads pool maximum number of threads
58 workerPoolStrategy | ROUND_ROBIN/LESS_RECENTLY_USED/... | [poolifier](https://github.com/poolifier/poolifier) default: ROUND_ROBBIN | string | worker threads pool [poolifier](https://github.com/poolifier/poolifier) worker choice strategy
59 chargingStationsPerWorker | | 1 | integer | number of charging stations per worker threads for the `workerSet` process type
60 logStatisticsInterval | | 60 | integer | seconds between charging stations statistics output in the logs
61 logConsole | true/false | false | boolean | output logs on the console
62 logFormat | | simple | string | winston log format
63 logRotate | true/false | true | boolean | enable daily log files rotation
64 logMaxFiles | | 7 | integer | maximum number of log files to keep
65 logLevel | emerg/alert/crit/error/warning/notice/info/debug | info | string | winston logging level
66 logFile | | combined.log | string | log file relative path
67 logErrorFile | | error.log | string | error log file relative path
68 performanceStorage | | { "enabled": false, "type": "jsonfile", "file:///performanceMeasurements.json" } | { enabled: string; type: string; URI: string; } where type can be 'jsonfile', 'mysql', 'mariadb', 'sqlite' or 'mongodb' | performance storage configuration section
69 stationTemplateURLs | | {}[] | { file: string; numberOfStations: number; }[] | array of charging station templates URIs configuration section (template file name and number of stations)
70
71 #### Worker process model:
72
73 - **workerSet**:
74 Worker set executing each a static number (chargingStationsPerWorker) of simulated charging stations from the total
75
76 - **staticPool**:
77 Statically sized worker pool executing a static total number of simulated charging stations
78
79 - **dynamicPool**:
80 Dynamically sized worker pool executing a static total number of simulated charging stations
81
82 ### Charging station template
83
84 Key | Value(s) | Default Value | Value type | Description
85 --- | -------| --------------| ---------- | ------------
86 supervisionURL | | '' | string | connection URI to OCPP-J server
87 supervisionUser | | '' | string | basic HTTP authentication user to OCPP-J server
88 supervisionPassword | | '' | string | basic HTTP authentication password to OCPP-J server
89 ocppVersion | 1.6 | 1.6 | string | OCPP version
90 ocppProtocol | json | json | string | OCPP protocol
91 authorizationFile | | '' | string | RFID tags list file relative to src/assets path
92 baseName | | '' | string | base name to build charging stations name
93 nameSuffix | | '' | string | name suffix to build charging stations name
94 fixedName | true/false | false | boolean | use the baseName as the charging stations unique name
95 chargePointModel | | '' | string | charging stations model
96 chargePointVendor | | '' | string | charging stations vendor
97 chargeBoxSerialNumberPrefix | | '' | string | charging stations serial number prefix
98 firmwareVersion | | '' | string | charging stations firmware version
99 power | | | float\|float[] | charging stations maximum power value(s)
100 powerSharedByConnectors | true/false | false | boolean | charging stations power shared by its connectors
101 powerUnit | W/kW | W | string | charging stations power unit
102 currentOutType | AC/DC | AC | string | charging stations current out type
103 voltageOut | | AC:230/DC:400 | integer | charging stations voltage out
104 numberOfPhases | 0/1/3 | AC:3/DC:0 | integer | charging stations number of phase(s)
105 numberOfConnectors | | | integer\|integer[] | charging stations number of connector(s)
106 useConnectorId0 | true/false | true | boolean | use connector id 0 definition from the template
107 randomConnectors | true/false | false | boolean | randomize runtime connector id affectation from the connector id definition in template
108 resetTime | | 60 | integer | seconds to wait before the charging stations come back at reset
109 autoRegister | true/false | false | boolean | set the charging station as registered at boot notification for testing purpose
110 autoReconnectMaxRetries | | -1 (unlimited) | integer | connection retries to the OCPP-J server
111 reconnectExponentialDelay | true/false | false | boolean | connection delay retry to the OCPP-J server
112 registrationMaxRetries | | -1 (unlimited) | integer | charging stations boot notification retries
113 enableStatistics | true/false | true | boolean | enable charging stations statistics
114 mayAuthorizeAtRemoteStart | true/false | true | boolean | always send authorize at remote start transaction when AuthorizeRemoteTxRequests is enabled
115 beginEndMeterValues | true/false | false | boolean | enable Transaction.{Begin,End} MeterValues
116 outOfOrderEndMeterValues | true/false | false | boolean | send Transaction.End MeterValues out of order
117 meteringPerTransaction | true/false | true | boolean | enable metering history on a per transaction basis
118 transactionDataMeterValues | true/false | false | boolean | enable transaction data MeterValues at stop transaction
119 mainVoltageMeterValues | true/false | true | boolean | include charging station main voltage MeterValues on three phased charging stations
120 phaseLineToLineVoltageMeterValues | true/false | true | boolean | include charging station line to line voltage MeterValues on three phased charging stations
121 Configuration | | | ChargingStationConfiguration | charging stations OCPP parameters configuration section
122 AutomaticTransactionGenerator | | | AutomaticTransactionGenerator | charging stations ATG configuration section
123 Connectors | | | Connectors | charging stations connectors configuration section
124
125 #### Configuration section
126
127 ```json
128 "Configuration": {
129 "configurationKey": [
130 ...
131 {
132 "key": "StandardKey",
133 "readonly": false,
134 "value": "StandardValue",
135 "visible": true,
136 "reboot": false
137 },
138 ...
139 {
140 "key": "VendorKey",
141 "readonly": false,
142 "value": "VendorValue",
143 "visible": false,
144 "reboot": true
145 },
146 ...
147 ]
148 }
149 ```
150
151 #### AutomaticTransactionGenerator section
152
153 ```json
154 "AutomaticTransactionGenerator": {
155 "enable": false,
156 "minDuration": 60,
157 "maxDuration": 80,
158 "minDelayBetweenTwoTransactions": 15,
159 "maxDelayBetweenTwoTransactions": 30,
160 "probabilityOfStart": 1,
161 "stopAfterHours": 0.3,
162 "stopOnConnectionFailure": true,
163 "requireAuthorize": true
164 }
165 ```
166 #### Connectors section
167
168 ```json
169 "Connectors": {
170 "0": {},
171 "1": {
172 "bootStatus": "Available",
173 "MeterValues": [
174 ...
175 {
176 "unit": "W",
177 "measurand": "Power.Active.Import",
178 "phase": "L1-N",
179 "value": "5000",
180 "fluctuationPercent": "10"
181 },
182 ...
183 {
184 "unit": "A",
185 "measurand": "Current.Import"
186 },
187 ...
188 {
189 "unit": "Wh"
190 },
191 ...
192 ]
193 }
194 },
195 ```
196
197 ## Start
198
199 To start the program, run: `npm start`.
200
201 ## Docker
202
203 In the [docker](./docker) folder:
204
205 ```bash
206 make
207 ```
208
209 Or without the optional git submodules:
210
211 ```bash
212 make SUBMODULES_INIT=false
213 ```
214
215 ## OCPP-J commands supported
216
217 ### Version 1.6
218
219 #### Core Profile
220
221 - :white_check_mark: Authorize
222 - :white_check_mark: BootNotification
223 - :white_check_mark: ChangeAvailability
224 - :white_check_mark: ChangeConfiguration
225 - :white_check_mark: ClearCache
226 - :x: DataTransfer
227 - :white_check_mark: GetConfiguration
228 - :white_check_mark: Heartbeat
229 - :white_check_mark: MeterValues
230 - :white_check_mark: RemoteStartTransaction
231 - :white_check_mark: RemoteStopTransaction
232 - :white_check_mark: Reset
233 - :white_check_mark: StartTransaction
234 - :white_check_mark: StatusNotification
235 - :white_check_mark: StopTransaction
236 - :white_check_mark: UnlockConnector
237
238 #### Firmware Management Profile
239
240 - :white_check_mark: GetDiagnostics
241 - :x: DiagnosticsStatusNotification
242 - :x: FirmwareStatusNotification
243 - :x: UpdateFirmware
244
245 #### Local Auth List Management Profile
246
247 - :x: GetLocalListVersion
248 - :x: SendLocalList
249
250 #### Reservation Profile
251
252 - :x: CancelReservation
253 - :x: ReserveNow
254
255 #### Smart Charging Profile
256
257 - :white_check_mark: ClearChargingProfile
258 - :white_check_mark: GetCompositeSchedule
259 - :white_check_mark: SetChargingProfile
260
261 #### Remote Trigger Profile
262
263 - :white_check_mark: TriggerMessage
264
265 ## OCPP-J standard parameters supported
266
267 All kind of OCPP parameters are supported in a charging station template. The list here mention the standard ones also handled automatically in the simulator.
268
269 ### Version 1.6
270
271 #### Core Profile
272
273 - :white_check_mark: AuthorizeRemoteTxRequests (type: boolean) (units: -)
274 - :x: ClockAlignedDataInterval (type: integer) (units: seconds)
275 - :white_check_mark: ConnectionTimeOut (type: integer) (units: seconds)
276 - :x: GetConfigurationMaxKeys (type: integer) (units: -)
277 - :white_check_mark: HeartbeatInterval (type: integer) (units: seconds)
278 - :x: LocalAuthorizeOffline (type: boolean) (units: -)
279 - :x: LocalPreAuthorize (type: boolean) (units: -)
280 - :x: MeterValuesAlignedData (type: CSL) (units: -)
281 - :white_check_mark: MeterValuesSampledData (type: CSL) (units: -)
282 - :white_check_mark: MeterValueSampleInterval (type: integer) (units: seconds)
283 - :white_check_mark: NumberOfConnectors (type: integer) (units: -)
284 - :x: ResetRetries (type: integer) (units: times)
285 - :white_check_mark: ConnectorPhaseRotation (type: CSL) (units: -)
286 - :x: StopTransactionOnEVSideDisconnect (type: boolean) (units: -)
287 - :x: StopTransactionOnInvalidId (type: boolean) (units: -)
288 - :x: StopTxnAlignedData (type: CSL) (units: -)
289 - :x: StopTxnSampledData (type: CSL) (units: -)
290 - :white_check_mark: SupportedFeatureProfiles (type: CSL) (units: -)
291 - :x: TransactionMessageAttempts (type: integer) (units: times)
292 - :x: TransactionMessageRetryInterval (type: integer) (units: seconds)
293 - :x: UnlockConnectorOnEVSideDisconnect (type: boolean) (units: -)
294 - :white_check_mark: WebSocketPingInterval (type: integer) (units: seconds)
295
296 #### Firmware Management Profile
297
298 - *none*
299
300 #### Local Auth List Management Profile
301
302 - :white_check_mark: LocalAuthListEnabled (type: boolean) (units: -)
303 - :x: LocalAuthListMaxLength (type: integer) (units: -)
304 - :x: SendLocalListMaxLength (type: integer) (units: -)
305
306 #### Reservation Profile
307
308 - *none*
309
310 #### Smart Charging Profile
311
312 - :x: ChargeProfileMaxStackLevel (type: integer) (units: -)
313 - :x: ChargingScheduleAllowedChargingRateUnit (type: CSL) (units: -)
314 - :x: ChargingScheduleMaxPeriods (type: integer) (units: -)
315 - :x: MaxChargingProfilesInstalled (type: integer) (units: -)
316
317 #### Remote Trigger Profile
318
319 - *none*
320
321 ## License
322
323 This file and all other files in this repository are licensed under the Apache Software License, v.2 and copyrighted under the copyright in [NOTICE](NOTICE) file, except as noted otherwise in the [LICENSE](LICENSE) file or the code source file header.
324
325 Please note that Docker images can contain other software which may be licensed under different licenses. This LICENSE and NOTICE files are also included in the Docker image. For any usage of built Docker images please make sure to check the licenses of the artifacts contained in the images.