1 {
2 "supervisionUrlOcppConfiguration": true,
3 "supervisionUrlOcppKey": "ocppcentraladdress",
4 "idTagsFile": "idtags.json",
5 "baseName": "CS-EVLINK",
6 "chargePointModel": "MONOBLOCK",
7 "chargePointVendor": "Schneider Electric",
8 "chargeBoxSerialNumberPrefix": "EV.2S7P04",
9 "firmwareVersionPattern": "^(0|[1-9]\\d*)\\.(0|[1-9]\\d*)\\.(0|[1-9]\\d*)\\.(0|[1-9]\\d*)$",
10 "firmwareVersion": "3.3.0.10",
11 "power": 7360,
12 "powerUnit": "W",
13 "numberOfPhases": 1,
14 "numberOfConnectors": 1,
15 "randomConnectors": false,
16 "voltageOut": 231,
17 "amperageLimitationOcppKey": "maxintensitysocket",
18 "Configuration": {
19 "configurationKey": [
20 {
21 "key": "MeterValuesSampledData",
22 "readonly": false,
23 "value": "Energy.Active.Import.Register,Current.Import,Voltage"
24 },
25 {
26 "key": "MeterValueSampleInterval",
27 "readonly": false,
28 "value": "30"
29 },
30 {
31 "key": "SupportedFeatureProfiles",
32 "readonly": true,
33 "value": "Core,FirmwareManagement,LocalAuthListManagement,SmartCharging,RemoteTrigger,Reservation"
34 },
35 {
36 "key": "LocalAuthListEnabled",
37 "readonly": false,
38 "value": "false"
39 },
40 {
41 "key": "AuthorizeRemoteTxRequests",
42 "readonly": false,
43 "value": "false"
44 },
45 {
46 "key": "WebSocketPingInterval",
47 "readonly": false,
48 "value": "60"
49 },
50 {
51 "key": "ReserveConnectorZeroSupported",
52 "readonly": false,
53 "value": "false"
54 }
55 ]
56 },
57 "AutomaticTransactionGenerator": {
58 "enable": false,
59 "minDuration": 60,
60 "maxDuration": 80,
61 "minDelayBetweenTwoTransactions": 15,
62 "maxDelayBetweenTwoTransactions": 30,
63 "probabilityOfStart": 1,
64 "stopAfterHours": 0.3,
65 "stopOnConnectionFailure": false,
66 "requireAuthorize": true
67 },
68 "Connectors": {
69 "0": {},
70 "1": {
71 "MeterValues": [
72 {
73 "unit": "Wh",
74 "context": "Sample.Periodic",
75 "value": 0
76 }
77 ]
78 }
79 }
80 }