Add persistent OCPP parameters key/value support by CS generated name
[e-mobility-charging-stations-simulator.git] / src / assets / station-templates / schneider.station-template.json
1 {
2 "supervisionUrlOcppConfiguration": true,
3 "supervisionUrlOcppKey": "ocppcentraladdress",
4 "authorizationFile": "authorization-tags.json",
5 "baseName": "CS-SCHNEIDER",
6 "chargePointModel": "MONOBLOCK",
7 "chargePointVendor": "Schneider Electric",
8 "chargeBoxSerialNumberPrefix": "EV.2S22P44",
9 "firmwareVersion": "3.3.0.10",
10 "power": 44160,
11 "powerUnit": "W",
12 "numberOfConnectors": 2,
13 "randomConnectors": false,
14 "voltageOut": 231,
15 "Configuration": {
16 "configurationKey": [
17 {
18 "key": "MeterValuesSampledData",
19 "readonly": false,
20 "value": "Energy.Active.Import.Register,Current.Import,Voltage"
21 },
22 {
23 "key": "MeterValueSampleInterval",
24 "readonly": false,
25 "value": "30"
26 },
27 {
28 "key": "SupportedFeatureProfiles",
29 "readonly": true,
30 "value": "Core,LocalAuthListManagement"
31 },
32 {
33 "key": "LocalAuthListEnabled",
34 "readonly": false,
35 "value": "false"
36 },
37 {
38 "key": "AuthorizeRemoteTxRequests",
39 "readonly": false,
40 "value": "false"
41 },
42 {
43 "key": "WebSocketPingInterval",
44 "readonly": false,
45 "value": "60"
46 }
47 ]
48 },
49 "AutomaticTransactionGenerator": {
50 "enable": false,
51 "minDuration": 60,
52 "maxDuration": 80,
53 "minDelayBetweenTwoTransactions": 15,
54 "maxDelayBetweenTwoTransactions": 30,
55 "probabilityOfStart": 1,
56 "stopAfterHours": 0.3,
57 "stopOnConnectionFailure": false,
58 "requireAuthorize": true
59 },
60 "Connectors": {
61 "0": {},
62 "1": {
63 "MeterValues": [
64 {
65 "unit": "V",
66 "measurand": "Voltage"
67 },
68 {
69 "unit": "A",
70 "measurand": "Current.Import"
71 },
72 {
73 "unit": "Wh"
74 }
75 ]
76 },
77 "2": {
78 "MeterValues": [
79 {
80 "unit": "V",
81 "measurand": "Voltage"
82 },
83 {
84 "unit": "A",
85 "measurand": "Current.Import"
86 },
87 {
88 "unit": "Wh"
89 }
90 ]
91 }
92 }
93 }