600356598ee425eacceca4749482fef66952c5ab
[deb_libcec.git] / src / lib / devices / CECBusDevice.cpp
1 /*
2 * This file is part of the libCEC(R) library.
3 *
4 * libCEC(R) is Copyright (C) 2011 Pulse-Eight Limited. All rights reserved.
5 * libCEC(R) is an original work, containing original code.
6 *
7 * libCEC(R) is a trademark of Pulse-Eight Limited.
8 *
9 * This program is dual-licensed; you can redistribute it and/or modify
10 * it under the terms of the GNU General Public License as published by
11 * the Free Software Foundation; either version 2 of the License, or
12 * (at your option) any later version.
13 *
14 * This program is distributed in the hope that it will be useful,
15 * but WITHOUT ANY WARRANTY; without even the implied warranty of
16 * MERCHANTABILITY or FITNESS FOR A PARTICULAR PURPOSE. See the
17 * GNU General Public License for more details.
18 *
19 * You should have received a copy of the GNU General Public License
20 * along with this program; if not, write to the Free Software
21 * Foundation, Inc., 59 Temple Place - Suite 330, Boston, MA 02111-1307, USA.
22 *
23 *
24 * Alternatively, you can license this library under a commercial license,
25 * please contact Pulse-Eight Licensing for more information.
26 *
27 * For more information contact:
28 * Pulse-Eight Licensing <license@pulse-eight.com>
29 * http://www.pulse-eight.com/
30 * http://www.pulse-eight.net/
31 */
32
33 #include "CECBusDevice.h"
34 #include "../CECProcessor.h"
35 #include "../implementations/ANCommandHandler.h"
36 #include "../implementations/CECCommandHandler.h"
37 #include "../implementations/SLCommandHandler.h"
38 #include "../implementations/VLCommandHandler.h"
39 #include "../platform/timeutils.h"
40
41 using namespace CEC;
42
43 CCECBusDevice::CCECBusDevice(CCECProcessor *processor, cec_logical_address iLogicalAddress, uint16_t iPhysicalAddress) :
44 m_iPhysicalAddress(iPhysicalAddress),
45 m_iLogicalAddress(iLogicalAddress),
46 m_powerStatus(CEC_POWER_STATUS_UNKNOWN),
47 m_processor(processor),
48 m_bMenuActive(true),
49 m_iVendorClass(CEC_VENDOR_UNKNOWN),
50 m_iLastActive(0),
51 m_cecVersion(CEC_VERSION_1_3A)
52 {
53 m_handler = new CCECCommandHandler(this);
54
55 for (unsigned int iPtr = 0; iPtr < 4; iPtr++)
56 m_menuLanguage.language[iPtr] = '?';
57 m_menuLanguage.language[3] = 0;
58 m_menuLanguage.device = iLogicalAddress;
59
60 m_vendor.vendor = CEC_VENDOR_UNKNOWN;
61 m_type = CEC_DEVICE_TYPE_RESERVED;
62 m_strDeviceName = "Unknown";
63 }
64
65 CCECBusDevice::~CCECBusDevice(void)
66 {
67 m_condition.Broadcast();
68 delete m_handler;
69 }
70
71 void CCECBusDevice::AddLog(cec_log_level level, const CStdString &strMessage)
72 {
73 m_processor->AddLog(level, strMessage);
74 }
75
76 bool CCECBusDevice::HandleCommand(const cec_command &command)
77 {
78 CLockObject lock(&m_mutex);
79 m_iLastActive = GetTimeMs();
80 m_handler->HandleCommand(command);
81 m_condition.Signal();
82 return true;
83 }
84
85 void CCECBusDevice::PollVendorId(void)
86 {
87 CLockObject lock(&m_mutex);
88 if (m_iLastActive > 0 && m_iLogicalAddress != CECDEVICE_BROADCAST &&
89 m_vendor.vendor == CEC_VENDOR_UNKNOWN &&
90 GetTimeMs() - m_iLastActive > 5000)
91 {
92 m_iLastActive = GetTimeMs();
93
94 cec_command command;
95 cec_command::format(command, GetMyLogicalAddress(), m_iLogicalAddress, CEC_OPCODE_GIVE_DEVICE_VENDOR_ID);
96 if (m_processor->Transmit(command))
97 m_condition.Wait(&m_mutex, 1000);
98 }
99 }
100
101 bool CCECBusDevice::PowerOn(void)
102 {
103 CStdString strLog;
104 strLog.Format("<< powering on device with logical address %d", (int8_t)m_iLogicalAddress);
105 AddLog(CEC_LOG_DEBUG, strLog.c_str());
106
107 cec_command command;
108 cec_command::format(command, GetMyLogicalAddress(), m_iLogicalAddress, CEC_OPCODE_IMAGE_VIEW_ON);
109
110 return m_processor->Transmit(command);
111 }
112
113 bool CCECBusDevice::Standby(void)
114 {
115 CStdString strLog;
116 strLog.Format("<< putting device with logical address %d in standby mode", (int8_t)m_iLogicalAddress);
117 AddLog(CEC_LOG_DEBUG, strLog.c_str());
118
119 cec_command command;
120 cec_command::format(command, GetMyLogicalAddress(), m_iLogicalAddress, CEC_OPCODE_STANDBY);
121
122 return m_processor->Transmit(command);
123 }
124
125 /** @name Getters */
126 //@{
127 cec_version CCECBusDevice::GetCecVersion(bool bRefresh /* = true */)
128 {
129 if (bRefresh || m_cecVersion == CEC_VERSION_UNKNOWN)
130 {
131 AddLog(CEC_LOG_NOTICE, "<< requesting CEC version");
132 cec_command command;
133 cec_command::format(command, GetMyLogicalAddress(), m_iLogicalAddress, CEC_OPCODE_GET_CEC_VERSION);
134 CLockObject lock(&m_mutex);
135 if (m_processor->Transmit(command))
136 m_condition.Wait(&m_mutex, 1000);
137 }
138
139 return m_cecVersion;
140 }
141
142 cec_menu_language &CCECBusDevice::GetMenuLanguage(bool bRefresh /* = true */)
143 {
144 if (bRefresh || !strcmp(m_menuLanguage.language, "???"))
145 {
146 AddLog(CEC_LOG_NOTICE, "<< requesting menu language");
147 cec_command command;
148 cec_command::format(command, GetMyLogicalAddress(), m_iLogicalAddress, CEC_OPCODE_GET_MENU_LANGUAGE);
149 CLockObject lock(&m_mutex);
150 if (m_processor->Transmit(command))
151 m_condition.Wait(&m_mutex, 1000);
152 }
153
154 return m_menuLanguage;
155 }
156
157 cec_logical_address CCECBusDevice::GetMyLogicalAddress(void) const
158 {
159 return m_processor->GetLogicalAddress();
160 }
161
162 uint16_t CCECBusDevice::GetMyPhysicalAddress(void) const
163 {
164 return m_processor->GetPhysicalAddress();
165 }
166
167 cec_power_status CCECBusDevice::GetPowerStatus(bool bRefresh /* = true */)
168 {
169 if (bRefresh || m_powerStatus == CEC_POWER_STATUS_UNKNOWN)
170 {
171 AddLog(CEC_LOG_NOTICE, "<< requesting power status");
172 cec_command command;
173 cec_command::format(command, GetMyLogicalAddress(), m_iLogicalAddress, CEC_OPCODE_GIVE_DEVICE_POWER_STATUS);
174 CLockObject lock(&m_mutex);
175 if (m_processor->Transmit(command))
176 m_condition.Wait(&m_mutex, 1000);
177 }
178
179 return m_powerStatus;
180 }
181
182 const cec_vendor &CCECBusDevice::GetVendor(void)
183 {
184 if (m_vendor.vendor == CEC_VENDOR_UNKNOWN)
185 {
186 AddLog(CEC_LOG_NOTICE, "<< requesting vendor ID");
187 cec_command command;
188 cec_command::format(command, GetMyLogicalAddress(), m_iLogicalAddress, CEC_OPCODE_GIVE_DEVICE_VENDOR_ID);
189 CLockObject lock(&m_mutex);
190
191 if (m_processor->Transmit(command))
192 m_condition.Wait(&m_mutex, 1000);
193 }
194
195 return m_vendor;
196 }
197
198 bool CCECBusDevice::MyLogicalAddressContains(cec_logical_address address) const
199 {
200 return m_processor->HasLogicalAddress(address);
201 }
202
203 //@}
204
205 /** @name Setters */
206 //@{
207 void CCECBusDevice::SetCecVersion(const cec_version newVersion)
208 {
209 CStdString strLog;
210 m_cecVersion = newVersion;
211
212 switch (newVersion)
213 {
214 case CEC_VERSION_1_2:
215 strLog.Format("device %d reports CEC version 1.2", m_iLogicalAddress);
216 break;
217 case CEC_VERSION_1_2A:
218 strLog.Format("device %d reports CEC version 1.2a", m_iLogicalAddress);
219 break;
220 case CEC_VERSION_1_3:
221 strLog.Format("device %d reports CEC version 1.3", m_iLogicalAddress);
222 break;
223 case CEC_VERSION_1_3A:
224 strLog.Format("device %d reports CEC version 1.3a", m_iLogicalAddress);
225 break;
226 default:
227 strLog.Format("device %d reports an unknown CEC version", m_iLogicalAddress);
228 m_cecVersion = CEC_VERSION_UNKNOWN;
229 break;
230 }
231 AddLog(CEC_LOG_DEBUG, strLog);
232 }
233
234 void CCECBusDevice::SetMenuLanguage(const cec_menu_language &language)
235 {
236 if (language.device == m_iLogicalAddress)
237 {
238 CStdString strLog;
239 strLog.Format("device %d menu language set to '%s'", m_iLogicalAddress, language.language);
240 m_processor->AddLog(CEC_LOG_DEBUG, strLog);
241 m_menuLanguage = language;
242 }
243 }
244
245 void CCECBusDevice::SetPhysicalAddress(uint16_t iNewAddress, uint16_t iOldAddress /* = 0 */)
246 {
247 if (iNewAddress > 0)
248 {
249 CStdString strLog;
250 strLog.Format(">> %i changed physical address from %04x to %04x", m_iLogicalAddress, m_iPhysicalAddress, iNewAddress);
251 AddLog(CEC_LOG_DEBUG, strLog.c_str());
252
253 m_iPhysicalAddress = iNewAddress;
254 }
255 }
256
257 void CCECBusDevice::SetPowerStatus(const cec_power_status powerStatus)
258 {
259 if (m_powerStatus != powerStatus)
260 {
261 CStdString strLog;
262 strLog.Format("device %d power status changed from %2x to %2x", m_iLogicalAddress, m_powerStatus, powerStatus);
263 m_processor->AddLog(CEC_LOG_DEBUG, strLog);
264 m_powerStatus = powerStatus;
265 }
266 }
267
268 void CCECBusDevice::SetVendorId(const cec_datapacket &data)
269 {
270 if (data.size < 3)
271 {
272 AddLog(CEC_LOG_WARNING, "invalid vendor ID received");
273 return;
274 }
275
276 uint64_t iVendorId = ((uint64_t)data[0] << 3) +
277 ((uint64_t)data[1] << 2) +
278 (uint64_t)data[2];
279
280 SetVendorId(iVendorId, data.size >= 4 ? data[3] : 0);
281 }
282
283 void CCECBusDevice::SetVendorId(uint64_t iVendorId, uint8_t iVendorClass /* = 0 */)
284 {
285 m_vendor.vendor = (cec_vendor_id)iVendorId;
286 m_iVendorClass = iVendorClass;
287
288 switch (iVendorId)
289 {
290 case CEC_VENDOR_SAMSUNG:
291 if (m_handler->GetVendorId() != CEC_VENDOR_SAMSUNG)
292 {
293 delete m_handler;
294 m_handler = new CANCommandHandler(this);
295 }
296 break;
297 case CEC_VENDOR_LG:
298 if (m_handler->GetVendorId() != CEC_VENDOR_LG)
299 {
300 delete m_handler;
301 m_handler = new CSLCommandHandler(this);
302 }
303 break;
304 case CEC_VENDOR_PANASONIC:
305 if (m_handler->GetVendorId() != CEC_VENDOR_PANASONIC)
306 {
307 delete m_handler;
308 m_handler = new CVLCommandHandler(this);
309 }
310 break;
311 default:
312 if (m_handler->GetVendorId() != CEC_VENDOR_UNKNOWN)
313 {
314 delete m_handler;
315 m_handler = new CCECCommandHandler(this);
316 }
317 break;
318 }
319
320 CStdString strLog;
321 strLog.Format("device %d: vendor = %s (%06x) class = %2x", m_iLogicalAddress, GetVendorName(), GetVendorId(), GetVendorClass());
322 m_processor->AddLog(CEC_LOG_DEBUG, strLog.c_str());
323 }
324 //@}
325
326 /** @name Transmit methods */
327 //@{
328 bool CCECBusDevice::TransmitActiveSource(void)
329 {
330 AddLog(CEC_LOG_NOTICE, "<< broadcasting active source");
331
332 cec_command command;
333 cec_command::format(command, m_iLogicalAddress, CECDEVICE_BROADCAST, CEC_OPCODE_ACTIVE_SOURCE);
334 command.parameters.push_back((uint8_t) ((m_iPhysicalAddress >> 8) & 0xFF));
335 command.parameters.push_back((uint8_t) (m_iPhysicalAddress & 0xFF));
336
337 return m_processor->Transmit(command);
338 }
339
340 bool CCECBusDevice::TransmitActiveView(void)
341 {
342 AddLog(CEC_LOG_DEBUG, "<< setting active view");
343
344 cec_command command;
345 cec_command::format(command, m_iLogicalAddress, CECDEVICE_BROADCAST, CEC_OPCODE_ACTIVE_SOURCE);
346 command.parameters.push_back((m_iPhysicalAddress >> 8) & 0xFF);
347 command.parameters.push_back(m_iPhysicalAddress & 0xFF);
348
349 return m_processor->Transmit(command);
350 }
351
352 bool CCECBusDevice::TransmitCECVersion(cec_logical_address dest)
353 {
354 AddLog(CEC_LOG_NOTICE, "<< reporting CEC version as 1.3a");
355
356 cec_command command;
357 cec_command::format(command, m_iLogicalAddress, dest, CEC_OPCODE_CEC_VERSION);
358 command.parameters.push_back(m_cecVersion);
359
360 return m_processor->Transmit(command);
361 }
362
363 bool CCECBusDevice::TransmitDeckStatus(cec_logical_address dest)
364 {
365 // need to support opcodes play and deck control before doing anything with this
366 AddLog(CEC_LOG_NOTICE, "<< deck status requested, feature abort");
367 m_processor->TransmitAbort(dest, CEC_OPCODE_GIVE_DEVICE_VENDOR_ID);
368 return false;
369 }
370
371 bool CCECBusDevice::TransmitInactiveView(void)
372 {
373 AddLog(CEC_LOG_DEBUG, "<< setting inactive view");
374
375 cec_command command;
376 cec_command::format(command, m_iLogicalAddress, CECDEVICE_BROADCAST, CEC_OPCODE_INACTIVE_SOURCE);
377 command.parameters.push_back((m_iPhysicalAddress >> 8) & 0xFF);
378 command.parameters.push_back(m_iPhysicalAddress & 0xFF);
379
380 return m_processor->Transmit(command);
381 }
382
383 bool CCECBusDevice::TransmitMenuState(cec_logical_address dest)
384 {
385 if (m_bMenuActive)
386 AddLog(CEC_LOG_NOTICE, "<< reporting menu state as active");
387 else
388 AddLog(CEC_LOG_NOTICE, "<< reporting menu state as inactive");
389
390 cec_command command;
391 cec_command::format(command, m_iLogicalAddress, dest, CEC_OPCODE_MENU_STATUS);
392 command.parameters.push_back(m_bMenuActive ? (uint8_t) CEC_MENU_STATE_ACTIVATED : (uint8_t) CEC_MENU_STATE_DEACTIVATED);
393
394 return m_processor->Transmit(command);
395 }
396
397 bool CCECBusDevice::TransmitOSDName(cec_logical_address dest)
398 {
399 CStdString strLog;
400 strLog.Format("<< reporting OSD name as %s", m_strDeviceName.c_str());
401 AddLog(CEC_LOG_NOTICE, strLog.c_str());
402
403 cec_command command;
404 cec_command::format(command, m_iLogicalAddress, dest, CEC_OPCODE_SET_OSD_NAME);
405 for (unsigned int iPtr = 0; iPtr < m_strDeviceName.length(); iPtr++)
406 command.parameters.push_back(m_strDeviceName.at(iPtr));
407
408 return m_processor->Transmit(command);
409 }
410
411 bool CCECBusDevice::TransmitOSDString(cec_logical_address dest, cec_display_control duration, const char *strMessage)
412 {
413 CStdString strLog;
414 strLog.Format("<< display message '%s'", strMessage);
415 AddLog(CEC_LOG_NOTICE, strLog.c_str());
416
417 cec_command command;
418 cec_command::format(command, m_iLogicalAddress, dest, CEC_OPCODE_SET_OSD_STRING);
419 command.parameters.push_back((uint8_t)duration);
420
421 unsigned int iLen = strlen(strMessage);
422 if (iLen > 13) iLen = 13;
423
424 for (unsigned int iPtr = 0; iPtr < iLen; iPtr++)
425 command.parameters.push_back(strMessage[iPtr]);
426
427 return m_processor->Transmit(command);
428 }
429
430 bool CCECBusDevice::TransmitPhysicalAddress(void)
431 {
432 CStdString strLog;
433 strLog.Format("<< reporting physical address as %04x", m_iPhysicalAddress);
434 AddLog(CEC_LOG_NOTICE, strLog.c_str());
435
436 cec_command command;
437 cec_command::format(command, m_iLogicalAddress, CECDEVICE_BROADCAST, CEC_OPCODE_REPORT_PHYSICAL_ADDRESS);
438 command.parameters.push_back((uint8_t) ((m_iPhysicalAddress >> 8) & 0xFF));
439 command.parameters.push_back((uint8_t) (m_iPhysicalAddress & 0xFF));
440 command.parameters.push_back((uint8_t) (CEC_DEVICE_TYPE_PLAYBACK_DEVICE));
441
442 return m_processor->Transmit(command);
443 }
444
445 bool CCECBusDevice::TransmitPoll(cec_logical_address dest)
446 {
447 bool bReturn(false);
448
449 if (dest == CECDEVICE_UNKNOWN)
450 dest = m_iLogicalAddress;
451
452 CStdString strLog;
453 strLog.Format("<< sending POLL from device %1x to device %1x", m_iLogicalAddress, (int8_t)dest);
454 AddLog(CEC_LOG_DEBUG, strLog);
455
456 cec_command command;
457 cec_command::format(command, m_iLogicalAddress, dest, CEC_OPCODE_NONE);
458 CLockObject lock(&m_mutex);
459
460 bReturn = m_processor->Transmit(command);
461 AddLog(CEC_LOG_DEBUG, bReturn ? ">> POLL sent" : ">> POLL not sent");
462 return bReturn;
463 }
464
465 bool CCECBusDevice::TransmitPowerState(cec_logical_address dest)
466 {
467 CStdString strLog;
468 strLog.Format("<< reporting power status '%d'", m_powerStatus);
469 AddLog(CEC_LOG_NOTICE, strLog);
470
471 cec_command command;
472 cec_command::format(command, m_iLogicalAddress, dest, CEC_OPCODE_REPORT_POWER_STATUS);
473 command.parameters.push_back((uint8_t) m_powerStatus);
474
475 return m_processor->Transmit(command);
476 }
477
478 bool CCECBusDevice::TransmitVendorID(cec_logical_address dest)
479 {
480 AddLog(CEC_LOG_NOTICE, "<< vendor ID requested, feature abort");
481 m_processor->TransmitAbort(dest, CEC_OPCODE_GIVE_DEVICE_VENDOR_ID);
482 return false;
483 }
484 //@}