Add per phase support to MeterValues in template.
[e-mobility-charging-stations-simulator.git] / src / utils / Constants.ts
1 import { AvailabilityStatus, ChargingProfileStatus, ClearChargingProfileStatus, ConfigurationStatus, DefaultStatus, UnlockStatus } from '../types/ocpp/Responses';
2
3 import { MeterValueMeasurand } from '../types/ocpp/MeterValues';
4
5 export default class Constants {
6 static readonly ENTITY_CHARGING_STATION = 'ChargingStation';
7 static readonly ENTITY_AUTOMATIC_TRANSACTION_GENERATOR = 'AutomaticTransactionGenerator';
8
9 static readonly OCPP_RESPONSE_ACCEPTED = Object.freeze({ status: DefaultStatus.ACCEPTED });
10 static readonly OCPP_RESPONSE_REJECTED = Object.freeze({ status: DefaultStatus.REJECTED });
11 static readonly OCPP_CONFIGURATION_RESPONSE_ACCEPTED = Object.freeze({ status: ConfigurationStatus.ACCEPTED });
12 static readonly OCPP_CONFIGURATION_RESPONSE_REJECTED = Object.freeze({ status: ConfigurationStatus.REJECTED });
13 static readonly OCPP_CONFIGURATION_RESPONSE_REBOOT_REQUIRED = Object.freeze({ status: ConfigurationStatus.REBOOT_REQUIRED });
14 static readonly OCPP_CONFIGURATION_RESPONSE_NOT_SUPPORTED = Object.freeze({ status: ConfigurationStatus.NOT_SUPPORTED });
15 static readonly OCPP_SET_CHARGING_PROFILE_RESPONSE_ACCEPTED = Object.freeze({ status: ChargingProfileStatus.ACCEPTED });
16 static readonly OCPP_SET_CHARGING_PROFILE_RESPONSE_REJECTED = Object.freeze({ status: ChargingProfileStatus.REJECTED });
17 static readonly OCPP_SET_CHARGING_PROFILE_RESPONSE_NOT_SUPPORTED = Object.freeze({ status: ChargingProfileStatus.NOT_SUPPORTED });
18 static readonly OCPP_CLEAR_CHARGING_PROFILE_RESPONSE_ACCEPTED = Object.freeze({ status: ClearChargingProfileStatus.ACCEPTED });
19 static readonly OCPP_CLEAR_CHARGING_PROFILE_RESPONSE_UNKNOWN = Object.freeze({ status: ClearChargingProfileStatus.UNKNOWN });
20 static readonly OCPP_RESPONSE_UNLOCKED = Object.freeze({ status: UnlockStatus.UNLOCKED });
21 static readonly OCPP_RESPONSE_UNLOCK_FAILED = Object.freeze({ status: UnlockStatus.UNLOCK_FAILED });
22 static readonly OCPP_RESPONSE_UNLOCK_NOT_SUPPORTED = Object.freeze({ status: UnlockStatus.NOT_SUPPORTED });
23 static readonly OCPP_AVAILABILITY_RESPONSE_ACCEPTED = Object.freeze({ status: AvailabilityStatus.ACCEPTED });
24 static readonly OCPP_AVAILABILITY_RESPONSE_REJECTED = Object.freeze({ status: AvailabilityStatus.REJECTED });
25 static readonly OCPP_AVAILABILITY_RESPONSE_SCHEDULED = Object.freeze({ status: AvailabilityStatus.SCHEDULED });
26
27 static readonly OCPP_DEFAULT_BOOT_NOTIFICATION_INTERVAL = 60000; // Ms
28 static readonly OCPP_ERROR_TIMEOUT = 60000; // 60 sec
29
30 static readonly CHARGING_STATION_DEFAULT_RESET_TIME = 60000; // Ms
31 static readonly CHARGING_STATION_ATG_WAIT_TIME = 2000; // Ms
32 static readonly CHARGING_STATION_ATG_INITIALIZATION_TIME = 1000; // Ms
33
34 static readonly TRANSACTION_DEFAULT_IDTAG = '00000000';
35
36 static readonly WORKER_START_DELAY = 500;
37 static readonly WORKER_POOL_MAX_INACTIVE_TIME = 60000;
38 static readonly DEFAULT_WORKER_POOL_MIN_SIZE = 4;
39 static readonly DEFAULT_WORKER_POOL_MAX_SIZE = 16;
40 static readonly DEFAULT_CHARGING_STATIONS_PER_WORKER = 1;
41
42 static readonly DEFAULT_CONNECTION_TIMEOUT = 30;
43
44 static readonly SUPPORTED_MEASURANDS = Object.freeze([MeterValueMeasurand.STATE_OF_CHARGE, MeterValueMeasurand.VOLTAGE,
45 MeterValueMeasurand.POWER_ACTIVE_IMPORT, MeterValueMeasurand.CURRENT_IMPORT, MeterValueMeasurand.ENERGY_ACTIVE_IMPORT_REGISTER]);
46
47 static readonly DEFAULT_FLUCTUATION_PERCENT = 5;
48 }