useConnectorId0 | true/false | true | boolean | use connector id 0 definition from the template
randomConnectors | true/false | false | boolean | randomize runtime connector id affectation from the connector id definition in template
resetTime | | 60 | integer | seconds to wait before the charging stations come back at reset
-connectionTimeout | | 30 | integer | connection timeout to the OCPP-J server
+autoRegister | true/false | false | boolean | set the charging station as registered at boot notification for testing purpose
autoReconnectMaxRetries | | -1 (unlimited) | integer | connection retries to the OCPP-J server
reconnectExponentialDelay | true/false | false | boolean | connection delay retry to the OCPP-J server
registrationMaxRetries | | -1 (unlimited) | integer | charging stations boot notification retries
enableStatistics | true/false | true | boolean | enable charging stations statistics
+mayAuthorizeAtRemoteStart | true/false | true | boolean | always send authorize at remote start transaction when AuthorizeRemoteTxRequests is enabled
beginEndMeterValues | true/false | false | boolean | enable Transaction.{Begin,End} MeterValues
outOfOrderEndMeterValues | true/false | false | boolean | send Transaction.End MeterValues out of order
-meteringPerTransaction | true/false | true | boolean | disable metering on a per transaction basis
+meteringPerTransaction | true/false | true | boolean | enable metering history on a per transaction basis
transactionDataMeterValues | true/false | false | boolean | enable transaction data MeterValues at stop transaction
+mainVoltageMeterValues | true/false | true | boolean | include charging station main voltage MeterValues on three phased charging stations
+phaseLineToLineVoltageMeterValues | true/false | true | boolean | include charging station line to line voltage MeterValues on three phased charging stations
Configuration | | | ChargingStationConfiguration | charging stations OCPP configuration parameters
AutomaticTransactionGenerator | | | AutomaticTransactionGenerator | charging stations ATG configuration
Connectors | | | Connectors | charging stations connectors configuration
"1": {
"bootStatus": "Available",
"MeterValues": [
+ ...
+ {
+ "unit": "W",
+ "measurand": "Power.Active.Import",
+ "phase": "L1-N",
+ "value": "5000",
+ "fluctuationPercent": "10"
+ },
...
{
"unit": "A",
### Version 1.6
-### Core Profile
+#### Core Profile
- :white_check_mark: Authorize
- :white_check_mark: BootNotification
- :white_check_mark: StopTransaction
- :white_check_mark: UnlockConnector
-### Firmware Management Profile
+#### Firmware Management Profile
- :x: GetDiagnostics
- :x: DiagnosticsStatusNotification
- :x: FirmwareStatusNotification
- :x: UpdateFirmware
-### Local Auth List Management Profile
+#### Local Auth List Management Profile
- :x: GetLocalListVersion
- :x: SendLocalList
-### Reservation Profile
+#### Reservation Profile
- :x: CancelReservation
- :x: ReserveNow
-### Smart Charging Profile
+#### Smart Charging Profile
- :white_check_mark: ClearChargingProfile
- :white_check_mark: GetCompositeSchedule
- :white_check_mark: SetChargingProfile
-### Remote Trigger Profile
+#### Remote Trigger Profile
- :x: TriggerMessage
## OCPP-J standard parameters supported
-All kind of OCPP parameters is supported in a charging station template. The list here mention the standard ones also handled automatically in the simulator.
+All kind of OCPP parameters are supported in a charging station template. The list here mention the standard ones also handled automatically in the simulator.
### Version 1.6
-### Core Profile
+#### Core Profile
- :white_check_mark: AuthorizeRemoteTxRequests (type: boolean) (units: -)
- :x: ClockAlignedDataInterval (type: integer) (units: seconds)
-- :x: ConnectionTimeOut (type: integer) (units: seconds)
+- :white_check_mark: ConnectionTimeOut (type: integer) (units: seconds)
- :x: GetConfigurationMaxKeys (type: integer) (units: -)
- :white_check_mark: HeartbeatInterval (type: integer) (units: seconds)
- :x: LocalAuthorizeOffline (type: boolean) (units: -)
- :x: StopTransactionOnInvalidId (type: boolean) (units: -)
- :x: StopTxnAlignedData (type: CSL) (units: -)
- :x: StopTxnSampledData (type: CSL) (units: -)
-- :x: SupportedFeatureProfiles (type: CSL) (units: -)
+- :white_check_mark: SupportedFeatureProfiles (type: CSL) (units: -)
- :x: TransactionMessageAttempts (type: integer) (units: times)
- :x: TransactionMessageRetryInterval (type: integer) (units: seconds)
- :x: UnlockConnectorOnEVSideDisconnect (type: boolean) (units: -)
+- :white_check_mark: WebSocketPingInterval (type: integer) (units: seconds)
-### Firmware Management Profile
+#### Firmware Management Profile
- *none*
-### Local Auth List Management Profile
+#### Local Auth List Management Profile
-- :x: LocalAuthListEnabled (type: boolean) (units: -)
+- :white_check_mark: LocalAuthListEnabled (type: boolean) (units: -)
- :x: LocalAuthListMaxLength (type: integer) (units: -)
- :x: SendLocalListMaxLength (type: integer) (units: -)
-### Reservation Profile
+#### Reservation Profile
- *none*
-### Smart Charging Profile
+#### Smart Charging Profile
- :x: ChargeProfileMaxStackLevel (type: integer) (units: -)
- :x: ChargingScheduleAllowedChargingRateUnit (type: CSL) (units: -)
- :x: ChargingScheduleMaxPeriods (type: integer) (units: -)
- :x: MaxChargingProfilesInstalled (type: integer) (units: -)
-### Remote Trigger Profile
+#### Remote Trigger Profile
- *none*