+libcec (1.2-1) unstable; urgency=low
+
+ * bugfixes:
+ * pass the deck_control command to libcec listeners
+ * check whether the initiator is valid in CCECProcessor::ParseCommand().
+ fixes possible segfault when parsing invalid data
+
+ -- Pulse-Eight Packaging <packaging@pulse-eight.com> Sat, 12 Nov 2011 13:36:00 +0100
+
+libcec (1.1-3) unstable; urgency=low
+
+ * fixed return value in CCECProcessor::SetStreamPath(), which prevented
+ active source and menu state from being sent
+
+ -- Pulse-Eight Packaging <packaging@pulse-eight.com> Fri, 11 Nov 2011 23:36:00 +0100
+
+libcec (1.1-2) unstable; urgency=low
+
+ * forgot to update the headers to v1.1
+
+ -- Pulse-Eight Packaging <packaging@pulse-eight.com> Fri, 11 Nov 2011 18:56:00 +0100
+
+libcec (1.1-1) unstable; urgency=low
+
+ * interface changes:
+ * added logical address autodetection and let libcec handle multiple types
+ simultaniously. for logical address autodetection, you have to use
+ CECInit()/cec_init_typed() instead of CECCreate()/cec_init()
+ * added SetActiveSource()/cec_set_active_source() to the interface.
+ deprecated SetActiveView()/cec_set_active_view()
+ * added SetMenuState()
+ * added PollDevice()/cec_poll_device()
+ * removed duplicate method SetActiveSource() / SetActiveView()
+ * added SetDeckControlMode() and SetDeckInfo()
+ * fixed:
+ * added vendor detection for panasonic and broadcast active view and set
+ menu state when a panasonic device sets the stream path. thanks for the
+ pointer cptcoconut.
+ * added vendor code for pioneer
+ * osd string is 13 chars max. don't send more
+ * send the correct cec version for each device
+ * switch to panasonic specific cec implementation if a panasonic device was
+ detected
+ * send the correct device type in TransmitPhysicalAddress()
+ * send a reply from the correct device when the stream path is requested
+ * opcode 0x80 means the stream path changed, not the physical address
+ * don't poll for a vendor ID in monitoring mode
+ * fixed parameter parsing in SetVendorId()
+ * buffer up commands that are received while waiting for an ack. only send
+ 'active source' message for the actual active source
+ * win32: prepend the com port path with '\\.\', so com ports > 9 can be
+ accessed. thanks smolesen
+ * audio systems cannot be an active source, so don't transmit active
+ source message from this device
+ * only send 'active source' when powered on
+ * only set the osd name for the primary device. use default values for
+ others
+ * increase physical address with 0x100 per device
+ * win32: removed unneeded afxres.h include in the resource files, which
+ is not present when using studio express. thanks Ghuron
+ * fixed C headers
+ * mark the active source as active and other devices as inactive
+ * set the power status to 'on' when receiving CEC_USER_CONTROL_CODE_POWER
+ * transmit the menu state as (active) when the stream path is set
+ * changed:
+ * changed copyright of boblight files with permission of the original
+ author
+ * partial handling of audio related opcodes
+ * more consistent log messages
+ * set a device type and name for each CCECBusDevice
+ * keep a power and menu state per device
+ * renamed all Broadcast...() and Report...() methods to Transmit...()
+ * renamed SetOSDString() to TransmitOSDString()
+ * changed debug level of 'did not receive ack' from error to debug
+ * only set the power status to 'on' for the primary device
+ * moved method decriptions from cecc.h to cec.h
+ * only send a power on command when a device isn't on already and set
+ the power state to CEC_POWER_STATUS_IN_TRANSITION_STANDBY_TO_ON while
+ powering on
+ * handle CEC_OPCODE_STANDBY
+ * handle CEC_OPCODE_ACTIVE_SOURCE
+ * always start in standby mode and let the tv (or other device) send the
+ power on command
+ * renamed the last few enums
+ * handle deck related opcodes.
+ * added TransmitVendorId(), but only transmit the id if it's not set to 'unknown'
+
+ -- Pulse-Eight Packaging <packaging@pulse-eight.com> Fri, 11 Nov 2011 17:42:00 +0100
+
+libcec (1.0-1) unstable; urgency=low
+
+ * interface changes:
+ * set lib interface version back to 1.0 and rename GetLibVersion() to
+ GetLibVersionMajor() and GetMinVersion() to GetMinLibVersion()
+ * added GetLibVersionMinor()/cec_get_lib_version_minor() and set the minor
+ version number to 1
+ * fixed:
+ * samsung's vendor specific remote keypresses don't send key releases. added
+ call to AddKey() directly after the keypress
+ * always reset the button press time in CLibCEC::AddKey()
+ * always wait for a signal in CCECProcessor::Transmit()
+ * changed:
+ * drop shared_ptr and use a normal pointer. removed boost dependency
+
+ -- Pulse-Eight Packaging <packaging@pulse-eight.com> Fri, 04 Nov 2011 00:14:00 +0100
+
+libcec (0.8-2) unstable; urgency=low
+
+ * added 'libboost-dev' to build deps
+
+ -- Pulse-Eight Packaging <packaging@pulse-eight.com> Tue, 01 Nov 2011 23:31:00 +0100
+
libcec (0.8-1) unstable; urgency=low
* interface changes:
* added GetDeviceMenuLanguage()/cec_get_device_menu_language()
* added GetDeviceCecVersion()/cec_get_device_cec_version()
* added SwitchMonitoring()/cec_switch_monitoring() to the interface. when
- monitoring is enabled, the device will only log the data it received,
- but will not respond to any message
+ monitoring is enabled, the device will only log the data it received,
+ but will not respond to any message
* removed timeout parameter in Transmit() and included the ack timeout in
- the cec_command struct
+ the cec_command struct
* made the vendor id -> vendor name translation available
* made CEC_LOG levels powers of 2
* introduced CEC_LOG_TRAFFIC log level
* wait for ack while keeping a lock
* wait for the processor thread to start before continueing on startup
* wait for messages to be transmitted before continueing in
- CCECProcessor::Transmit()
+ CCECProcessor::Transmit()
* only set the logical address once when it has changed
* correct source for broadcast messages
* win32: create Release type installer
* changed:
* make all reads and write in CAdapterCommunication go through buffers.
* poll for a vendor ID of connected devices and switch to a non-standard
- CEC implementation if needed.
+ CEC implementation if needed.
* added vendor detection of Samsung and LG devices
* handle samsung remote command 'return'
* cec-client:
* added -la and --logical-address to the command line params
* added -d and --log-level params to cec-client
* added -sf and --short-log-file, which only log the actual messages, not
- the level and timestamp
+ the level and timestamp
* added -f and --log-file parameters to cec-client
* added option to change the log level to cec-client
- -- Pulse-Eight Packaging <packaging@pulse-eight.com> Tue, 01 Nov 2011 22:58:00 +0200
+ -- Pulse-Eight Packaging <packaging@pulse-eight.com> Tue, 01 Nov 2011 22:58:00 +0100
libcec (0.7-1) unstable; urgency=low