-import { ACElectricUtils, DCElectricUtils } from '../../../utils/ElectricUtils';
-import { AuthorizeRequest, OCPP16AuthorizeResponse, OCPP16StartTransactionResponse, OCPP16StopTransactionReason, OCPP16StopTransactionResponse, StartTransactionRequest, StopTransactionRequest } from '../../../types/ocpp/1.6/Transaction';
-import { CurrentType, Voltage } from '../../../types/ChargingStationTemplate';
-import { DiagnosticsStatusNotificationRequest, HeartbeatRequest, OCPP16BootNotificationRequest, OCPP16IncomingRequestCommand, OCPP16RequestCommand, StatusNotificationRequest } from '../../../types/ocpp/1.6/Requests';
-import { MeterValueUnit, MeterValuesRequest, OCPP16MeterValue, OCPP16MeterValueMeasurand, OCPP16MeterValuePhase } from '../../../types/ocpp/1.6/MeterValues';
+// Partial Copyright Jerome Benoit. 2021. All Rights Reserved.
+import type ChargingStation from '../../ChargingStation';
import Constants from '../../../utils/Constants';
-import MeasurandPerPhaseSampledValueTemplates from '../../../types/MeasurandPerPhaseSampledValueTemplates';
-import MeasurandValues from '../../../types/MeasurandValues';
-import { MessageType } from '../../../types/ocpp/MessageType';
-import { OCPP16BootNotificationResponse } from '../../../types/ocpp/1.6/Responses';
-import { OCPP16ChargePointErrorCode } from '../../../types/ocpp/1.6/ChargePointErrorCode';
-import { OCPP16ChargePointStatus } from '../../../types/ocpp/1.6/ChargePointStatus';
-import { OCPP16DiagnosticsStatus } from '../../../types/ocpp/1.6/DiagnosticsStatus';
+import { ErrorType } from '../../../types/ocpp/ErrorType';
+import { JsonType } from '../../../types/JsonType';
+import { OCPP16RequestCommand } from '../../../types/ocpp/1.6/Requests';
import { OCPP16ServiceUtils } from './OCPP16ServiceUtils';
-import OCPPError from '../../OcppError';
+import OCPPError from '../../../exception/OCPPError';
import OCPPRequestService from '../OCPPRequestService';
+import type OCPPResponseService from '../OCPPResponseService';
+import { RequestParams } from '../../../types/ocpp/Requests';
import Utils from '../../../utils/Utils';
-import logger from '../../../utils/Logger';
-export default class OCPP16RequestService extends OCPPRequestService {
- public async sendHeartbeat(): Promise<void> {
- try {
- const payload: HeartbeatRequest = {};
- await this.sendMessage(Utils.generateUUID(), payload, MessageType.CALL_MESSAGE, OCPP16RequestCommand.HEARTBEAT);
- } catch (error) {
- this.handleRequestError(OCPP16RequestCommand.HEARTBEAT, error);
- }
- }
-
- public async sendBootNotification(chargePointModel: string, chargePointVendor: string, chargeBoxSerialNumber?: string, firmwareVersion?: string,
- chargePointSerialNumber?: string, iccid?: string, imsi?: string, meterSerialNumber?: string, meterType?: string): Promise<OCPP16BootNotificationResponse> {
- try {
- const payload: OCPP16BootNotificationRequest = {
- chargePointModel,
- chargePointVendor,
- ...!Utils.isUndefined(chargeBoxSerialNumber) && { chargeBoxSerialNumber },
- ...!Utils.isUndefined(chargePointSerialNumber) && { chargePointSerialNumber },
- ...!Utils.isUndefined(firmwareVersion) && { firmwareVersion },
- ...!Utils.isUndefined(iccid) && { iccid },
- ...!Utils.isUndefined(imsi) && { imsi },
- ...!Utils.isUndefined(meterSerialNumber) && { meterSerialNumber },
- ...!Utils.isUndefined(meterType) && { meterType }
- };
- return await this.sendMessage(Utils.generateUUID(), payload, MessageType.CALL_MESSAGE, OCPP16RequestCommand.BOOT_NOTIFICATION) as OCPP16BootNotificationResponse;
- } catch (error) {
- this.handleRequestError(OCPP16RequestCommand.BOOT_NOTIFICATION, error);
- }
- }
+const moduleName = 'OCPP16RequestService';
- public async sendStatusNotification(connectorId: number, status: OCPP16ChargePointStatus,
- errorCode: OCPP16ChargePointErrorCode = OCPP16ChargePointErrorCode.NO_ERROR): Promise<void> {
- try {
- const payload: StatusNotificationRequest = {
- connectorId,
- errorCode,
- status,
- };
- await this.sendMessage(Utils.generateUUID(), payload, MessageType.CALL_MESSAGE, OCPP16RequestCommand.STATUS_NOTIFICATION);
- } catch (error) {
- this.handleRequestError(OCPP16RequestCommand.STATUS_NOTIFICATION, error);
- }
- }
-
- public async sendAuthorize(connectorId: number, idTag?: string): Promise<OCPP16AuthorizeResponse> {
- try {
- const payload: AuthorizeRequest = {
- ...!Utils.isUndefined(idTag) ? { idTag } : { idTag: Constants.TRANSACTION_DEFAULT_IDTAG },
- };
- this.chargingStation.getConnector(connectorId).authorizeIdTag = idTag;
- return await this.sendMessage(Utils.generateUUID(), payload, MessageType.CALL_MESSAGE, OCPP16RequestCommand.AUTHORIZE) as OCPP16AuthorizeResponse;
- } catch (error) {
- this.handleRequestError(OCPP16RequestCommand.AUTHORIZE, error);
- }
- }
-
- public async sendStartTransaction(connectorId: number, idTag?: string): Promise<OCPP16StartTransactionResponse> {
- try {
- const payload: StartTransactionRequest = {
- connectorId,
- ...!Utils.isUndefined(idTag) ? { idTag } : { idTag: Constants.TRANSACTION_DEFAULT_IDTAG },
- meterStart: this.chargingStation.getEnergyActiveImportRegisterByConnectorId(connectorId),
- timestamp: new Date().toISOString(),
- };
- return await this.sendMessage(Utils.generateUUID(), payload, MessageType.CALL_MESSAGE, OCPP16RequestCommand.START_TRANSACTION) as OCPP16StartTransactionResponse;
- } catch (error) {
- this.handleRequestError(OCPP16RequestCommand.START_TRANSACTION, error);
+export default class OCPP16RequestService extends OCPPRequestService {
+ public constructor(chargingStation: ChargingStation, ocppResponseService: OCPPResponseService) {
+ if (new.target?.name === moduleName) {
+ throw new TypeError(`Cannot construct ${new.target?.name} instances directly`);
}
+ super(chargingStation, ocppResponseService);
}
- public async sendStopTransaction(transactionId: number, meterStop: number, idTag?: string,
- reason: OCPP16StopTransactionReason = OCPP16StopTransactionReason.NONE): Promise<OCPP16StopTransactionResponse> {
- try {
- let connectorId: number;
- for (const connector in this.chargingStation.connectors) {
- if (Utils.convertToInt(connector) > 0 && this.chargingStation.getConnector(Utils.convertToInt(connector))?.transactionId === transactionId) {
- connectorId = Utils.convertToInt(connector);
- break;
- }
- }
- const transactionEndMeterValue = OCPP16ServiceUtils.buildTransactionEndMeterValue(this.chargingStation, connectorId, meterStop);
- // FIXME: should be a callback, each OCPP commands implementation must do only one job
- (this.chargingStation.getBeginEndMeterValues() && !this.chargingStation.getOutOfOrderEndMeterValues())
- && await this.sendTransactionEndMeterValues(connectorId, transactionId, transactionEndMeterValue);
- const payload: StopTransactionRequest = {
- transactionId,
- ...!Utils.isUndefined(idTag) && { idTag },
- meterStop,
- timestamp: new Date().toISOString(),
- ...reason && { reason },
- ...this.chargingStation.getTransactionDataMeterValues() && { transactionData: OCPP16ServiceUtils.buildTransactionDataMeterValues(this.chargingStation.getConnector(connectorId).transactionBeginMeterValue, transactionEndMeterValue) },
- };
- return await this.sendMessage(Utils.generateUUID(), payload, MessageType.CALL_MESSAGE, OCPP16RequestCommand.STOP_TRANSACTION) as OCPP16StartTransactionResponse;
- } catch (error) {
- this.handleRequestError(OCPP16RequestCommand.STOP_TRANSACTION, error);
+ public async requestHandler<Request extends JsonType, Response extends JsonType>(
+ commandName: OCPP16RequestCommand,
+ commandParams?: JsonType,
+ params?: RequestParams
+ ): Promise<Response> {
+ if (Object.values(OCPP16RequestCommand).includes(commandName)) {
+ return (await this.sendMessage(
+ Utils.generateUUID(),
+ this.buildRequestPayload<Request>(commandName, commandParams),
+ commandName,
+ params
+ )) as unknown as Response;
}
+ throw new OCPPError(
+ ErrorType.NOT_SUPPORTED,
+ `${moduleName}.requestHandler: Unsupported OCPP command ${commandName}`,
+ commandName,
+ { commandName }
+ );
}
- // eslint-disable-next-line consistent-this
- public async sendMeterValues(connectorId: number, transactionId: number, interval: number, self: OCPPRequestService, debug = false): Promise<void> {
- try {
- const meterValue: OCPP16MeterValue = {
- timestamp: new Date().toISOString(),
- sampledValue: [],
- };
- const connector = self.chargingStation.getConnector(connectorId);
- // SoC measurand
- const socSampledValueTemplate = self.chargingStation.getSampledValueTemplate(connectorId, OCPP16MeterValueMeasurand.STATE_OF_CHARGE);
- if (socSampledValueTemplate) {
- meterValue.sampledValue.push(OCPP16ServiceUtils.buildSampledValue(socSampledValueTemplate, Utils.getRandomInt(100)));
- const sampledValuesIndex = meterValue.sampledValue.length - 1;
- if (Utils.convertToInt(meterValue.sampledValue[sampledValuesIndex].value) > 100 || debug) {
- logger.error(`${self.chargingStation.logPrefix()} MeterValues measurand ${meterValue.sampledValue[sampledValuesIndex].measurand ?? OCPP16MeterValueMeasurand.ENERGY_ACTIVE_IMPORT_REGISTER}: connectorId ${connectorId}, transaction ${connector.transactionId}, value: ${meterValue.sampledValue[sampledValuesIndex].value}/100`);
- }
- }
- // Voltage measurand
- const voltageSampledValueTemplate = self.chargingStation.getSampledValueTemplate(connectorId, OCPP16MeterValueMeasurand.VOLTAGE);
- if (voltageSampledValueTemplate) {
- const voltageSampledValueTemplateValue = voltageSampledValueTemplate.value ? parseInt(voltageSampledValueTemplate.value) : self.chargingStation.getVoltageOut();
- const fluctuationPercent = voltageSampledValueTemplate.fluctuationPercent ?? Constants.DEFAULT_FLUCTUATION_PERCENT;
- const voltageMeasurandValue = Utils.getRandomFloatFluctuatedRounded(voltageSampledValueTemplateValue, fluctuationPercent);
- if (self.chargingStation.getNumberOfPhases() !== 3 || (self.chargingStation.getNumberOfPhases() === 3 && self.chargingStation.getMainVoltageMeterValues())) {
- meterValue.sampledValue.push(OCPP16ServiceUtils.buildSampledValue(voltageSampledValueTemplate, voltageMeasurandValue));
- }
- for (let phase = 1; self.chargingStation.getNumberOfPhases() === 3 && phase <= self.chargingStation.getNumberOfPhases(); phase++) {
- const phaseLineToNeutralValue = `L${phase}-N`;
- const voltagePhaseLineToNeutralSampledValueTemplate = self.chargingStation.getSampledValueTemplate(connectorId, OCPP16MeterValueMeasurand.VOLTAGE,
- phaseLineToNeutralValue as OCPP16MeterValuePhase);
- let voltagePhaseLineToNeutralMeasurandValue: number;
- if (voltagePhaseLineToNeutralSampledValueTemplate) {
- const voltagePhaseLineToNeutralSampledValueTemplateValue = voltagePhaseLineToNeutralSampledValueTemplate.value ? parseInt(voltagePhaseLineToNeutralSampledValueTemplate.value) : self.chargingStation.getVoltageOut();
- const fluctuationPhaseToNeutralPercent = voltagePhaseLineToNeutralSampledValueTemplate.fluctuationPercent ?? Constants.DEFAULT_FLUCTUATION_PERCENT;
- voltagePhaseLineToNeutralMeasurandValue = Utils.getRandomFloatFluctuatedRounded(voltagePhaseLineToNeutralSampledValueTemplateValue, fluctuationPhaseToNeutralPercent);
- }
- meterValue.sampledValue.push(OCPP16ServiceUtils.buildSampledValue(voltagePhaseLineToNeutralSampledValueTemplate ?? voltageSampledValueTemplate,
- voltagePhaseLineToNeutralMeasurandValue ?? voltageMeasurandValue, null, phaseLineToNeutralValue as OCPP16MeterValuePhase));
- if (self.chargingStation.getPhaseLineToLineVoltageMeterValues()) {
- const phaseLineToLineValue = `L${phase}-L${(phase + 1) % self.chargingStation.getNumberOfPhases() !== 0 ? (phase + 1) % self.chargingStation.getNumberOfPhases() : self.chargingStation.getNumberOfPhases()}`;
- const voltagePhaseLineToLineSampledValueTemplate = self.chargingStation.getSampledValueTemplate(connectorId, OCPP16MeterValueMeasurand.VOLTAGE, phaseLineToLineValue as OCPP16MeterValuePhase);
- let voltagePhaseLineToLineMeasurandValue: number;
- if (voltagePhaseLineToLineSampledValueTemplate) {
- const voltagePhaseLineToLineSampledValueTemplateValue = voltagePhaseLineToLineSampledValueTemplate.value ? parseInt(voltagePhaseLineToLineSampledValueTemplate.value) : Voltage.VOLTAGE_400;
- const fluctuationPhaseLineToLinePercent = voltagePhaseLineToLineSampledValueTemplate.fluctuationPercent ?? Constants.DEFAULT_FLUCTUATION_PERCENT;
- voltagePhaseLineToLineMeasurandValue = Utils.getRandomFloatFluctuatedRounded(voltagePhaseLineToLineSampledValueTemplateValue, fluctuationPhaseLineToLinePercent);
- }
- const defaultVoltagePhaseLineToLineMeasurandValue = Utils.getRandomFloatFluctuatedRounded(Voltage.VOLTAGE_400, fluctuationPercent);
- meterValue.sampledValue.push(OCPP16ServiceUtils.buildSampledValue(voltagePhaseLineToLineSampledValueTemplate ?? voltageSampledValueTemplate,
- voltagePhaseLineToLineMeasurandValue ?? defaultVoltagePhaseLineToLineMeasurandValue, null, phaseLineToLineValue as OCPP16MeterValuePhase));
- }
- }
- }
- // Power.Active.Import measurand
- const powerSampledValueTemplate = self.chargingStation.getSampledValueTemplate(connectorId, OCPP16MeterValueMeasurand.POWER_ACTIVE_IMPORT);
- let powerPerPhaseSampledValueTemplates: MeasurandPerPhaseSampledValueTemplates = {};
- if (self.chargingStation.getNumberOfPhases() === 3) {
- powerPerPhaseSampledValueTemplates = {
- L1: self.chargingStation.getSampledValueTemplate(connectorId, OCPP16MeterValueMeasurand.POWER_ACTIVE_IMPORT, OCPP16MeterValuePhase.L1_N),
- L2: self.chargingStation.getSampledValueTemplate(connectorId, OCPP16MeterValueMeasurand.POWER_ACTIVE_IMPORT, OCPP16MeterValuePhase.L2_N),
- L3: self.chargingStation.getSampledValueTemplate(connectorId, OCPP16MeterValueMeasurand.POWER_ACTIVE_IMPORT, OCPP16MeterValuePhase.L3_N),
- };
- }
- if (powerSampledValueTemplate) {
- OCPP16ServiceUtils.checkMeasurandPowerDivider(self.chargingStation, powerSampledValueTemplate.measurand);
- const errMsg = `${self.chargingStation.logPrefix()} MeterValues measurand ${powerSampledValueTemplate.measurand ?? OCPP16MeterValueMeasurand.ENERGY_ACTIVE_IMPORT_REGISTER}: Unknown ${self.chargingStation.getCurrentOutType()} currentOutType in template file ${self.chargingStation.stationTemplateFile}, cannot calculate ${powerSampledValueTemplate.measurand ?? OCPP16MeterValueMeasurand.ENERGY_ACTIVE_IMPORT_REGISTER} measurand value`;
- const powerMeasurandValues = {} as MeasurandValues;
- const unitDivider = powerSampledValueTemplate?.unit === MeterValueUnit.KILO_WATT ? 1000 : 1;
- const maxPower = Math.round(self.chargingStation.stationInfo.maxPower / self.chargingStation.stationInfo.powerDivider);
- const maxPowerPerPhase = Math.round((self.chargingStation.stationInfo.maxPower / self.chargingStation.stationInfo.powerDivider) / self.chargingStation.getNumberOfPhases());
- switch (self.chargingStation.getCurrentOutType()) {
- case CurrentType.AC:
- if (self.chargingStation.getNumberOfPhases() === 3) {
- const defaultFluctuatedPowerPerPhase = powerSampledValueTemplate.value
- && Utils.getRandomFloatFluctuatedRounded(parseInt(powerSampledValueTemplate.value) / self.chargingStation.getNumberOfPhases(), powerSampledValueTemplate.fluctuationPercent ?? Constants.DEFAULT_FLUCTUATION_PERCENT);
- const phase1FluctuatedValue = powerPerPhaseSampledValueTemplates?.L1?.value
- && Utils.getRandomFloatFluctuatedRounded(parseInt(powerPerPhaseSampledValueTemplates.L1.value), powerPerPhaseSampledValueTemplates.L1.fluctuationPercent ?? Constants.DEFAULT_FLUCTUATION_PERCENT);
- const phase2FluctuatedValue = powerPerPhaseSampledValueTemplates?.L2?.value
- && Utils.getRandomFloatFluctuatedRounded(parseInt(powerPerPhaseSampledValueTemplates.L2.value), powerPerPhaseSampledValueTemplates.L2.fluctuationPercent ?? Constants.DEFAULT_FLUCTUATION_PERCENT);
- const phase3FluctuatedValue = powerPerPhaseSampledValueTemplates?.L3?.value
- && Utils.getRandomFloatFluctuatedRounded(parseInt(powerPerPhaseSampledValueTemplates.L3.value), powerPerPhaseSampledValueTemplates.L3.fluctuationPercent ?? Constants.DEFAULT_FLUCTUATION_PERCENT);
- powerMeasurandValues.L1 = (phase1FluctuatedValue ?? defaultFluctuatedPowerPerPhase) ?? Utils.getRandomFloatRounded(maxPowerPerPhase / unitDivider);
- powerMeasurandValues.L2 = (phase2FluctuatedValue ?? defaultFluctuatedPowerPerPhase) ?? Utils.getRandomFloatRounded(maxPowerPerPhase / unitDivider);
- powerMeasurandValues.L3 = (phase3FluctuatedValue ?? defaultFluctuatedPowerPerPhase) ?? Utils.getRandomFloatRounded(maxPowerPerPhase / unitDivider);
- } else {
- powerMeasurandValues.L1 = powerSampledValueTemplate.value
- ? Utils.getRandomFloatFluctuatedRounded(parseInt(powerSampledValueTemplate.value), powerSampledValueTemplate.fluctuationPercent ?? Constants.DEFAULT_FLUCTUATION_PERCENT)
- : Utils.getRandomFloatRounded(maxPower / unitDivider);
- powerMeasurandValues.L2 = 0;
- powerMeasurandValues.L3 = 0;
- }
- powerMeasurandValues.allPhases = Utils.roundTo(powerMeasurandValues.L1 + powerMeasurandValues.L2 + powerMeasurandValues.L3, 2);
- break;
- case CurrentType.DC:
- powerMeasurandValues.allPhases = powerSampledValueTemplate.value
- ? Utils.getRandomFloatFluctuatedRounded(parseInt(powerSampledValueTemplate.value), powerSampledValueTemplate.fluctuationPercent ?? Constants.DEFAULT_FLUCTUATION_PERCENT)
- : Utils.getRandomFloatRounded(maxPower / unitDivider);
- break;
- default:
- logger.error(errMsg);
- throw Error(errMsg);
- }
- meterValue.sampledValue.push(OCPP16ServiceUtils.buildSampledValue(powerSampledValueTemplate, powerMeasurandValues.allPhases));
- const sampledValuesIndex = meterValue.sampledValue.length - 1;
- const maxPowerRounded = Utils.roundTo(maxPower / unitDivider, 2);
- if (Utils.convertToFloat(meterValue.sampledValue[sampledValuesIndex].value) > maxPowerRounded || debug) {
- logger.error(`${self.chargingStation.logPrefix()} MeterValues measurand ${meterValue.sampledValue[sampledValuesIndex].measurand ?? OCPP16MeterValueMeasurand.ENERGY_ACTIVE_IMPORT_REGISTER}: connectorId ${connectorId}, transaction ${connector.transactionId}, value: ${meterValue.sampledValue[sampledValuesIndex].value}/${maxPowerRounded}`);
- }
- for (let phase = 1; self.chargingStation.getNumberOfPhases() === 3 && phase <= self.chargingStation.getNumberOfPhases(); phase++) {
- const phaseValue = `L${phase}-N`;
- meterValue.sampledValue.push(OCPP16ServiceUtils.buildSampledValue(powerPerPhaseSampledValueTemplates[`L${phase}`] ?? powerSampledValueTemplate, powerMeasurandValues[`L${phase}`], null,
- phaseValue as OCPP16MeterValuePhase));
- const sampledValuesPerPhaseIndex = meterValue.sampledValue.length - 1;
- const maxPowerPerPhaseRounded = Utils.roundTo(maxPowerPerPhase / unitDivider, 2);
- if (Utils.convertToFloat(meterValue.sampledValue[sampledValuesPerPhaseIndex].value) > maxPowerPerPhaseRounded || debug) {
- logger.error(`${self.chargingStation.logPrefix()} MeterValues measurand ${meterValue.sampledValue[sampledValuesPerPhaseIndex].measurand ?? OCPP16MeterValueMeasurand.ENERGY_ACTIVE_IMPORT_REGISTER}: phase ${meterValue.sampledValue[sampledValuesPerPhaseIndex].phase}, connectorId ${connectorId}, transaction ${connector.transactionId}, value: ${meterValue.sampledValue[sampledValuesPerPhaseIndex].value}/${maxPowerPerPhaseRounded}`);
- }
- }
- }
- // Current.Import measurand
- const currentSampledValueTemplate = self.chargingStation.getSampledValueTemplate(connectorId, OCPP16MeterValueMeasurand.CURRENT_IMPORT);
- let currentPerPhaseSampledValueTemplates: MeasurandPerPhaseSampledValueTemplates = {};
- if (self.chargingStation.getNumberOfPhases() === 3) {
- currentPerPhaseSampledValueTemplates = {
- L1: self.chargingStation.getSampledValueTemplate(connectorId, OCPP16MeterValueMeasurand.CURRENT_IMPORT, OCPP16MeterValuePhase.L1),
- L2: self.chargingStation.getSampledValueTemplate(connectorId, OCPP16MeterValueMeasurand.CURRENT_IMPORT, OCPP16MeterValuePhase.L2),
- L3: self.chargingStation.getSampledValueTemplate(connectorId, OCPP16MeterValueMeasurand.CURRENT_IMPORT, OCPP16MeterValuePhase.L3),
- };
- }
- if (currentSampledValueTemplate) {
- OCPP16ServiceUtils.checkMeasurandPowerDivider(self.chargingStation, currentSampledValueTemplate.measurand);
- const errMsg = `${self.chargingStation.logPrefix()} MeterValues measurand ${currentSampledValueTemplate.measurand ?? OCPP16MeterValueMeasurand.ENERGY_ACTIVE_IMPORT_REGISTER}: Unknown ${self.chargingStation.getCurrentOutType()} currentOutType in template file ${self.chargingStation.stationTemplateFile}, cannot calculate ${currentSampledValueTemplate.measurand ?? OCPP16MeterValueMeasurand.ENERGY_ACTIVE_IMPORT_REGISTER} measurand value`;
- const currentMeasurandValues: MeasurandValues = {} as MeasurandValues;
- let maxAmperage: number;
- switch (self.chargingStation.getCurrentOutType()) {
- case CurrentType.AC:
- maxAmperage = ACElectricUtils.amperagePerPhaseFromPower(self.chargingStation.getNumberOfPhases(), self.chargingStation.stationInfo.maxPower / self.chargingStation.stationInfo.powerDivider, self.chargingStation.getVoltageOut());
- if (self.chargingStation.getNumberOfPhases() === 3) {
- const defaultFluctuatedAmperagePerPhase = currentSampledValueTemplate.value
- && Utils.getRandomFloatFluctuatedRounded(parseInt(currentSampledValueTemplate.value), currentSampledValueTemplate.fluctuationPercent ?? Constants.DEFAULT_FLUCTUATION_PERCENT);
- const phase1FluctuatedValue = currentPerPhaseSampledValueTemplates?.L1?.value
- && Utils.getRandomFloatFluctuatedRounded(parseInt(currentPerPhaseSampledValueTemplates.L1.value), currentPerPhaseSampledValueTemplates.L1.fluctuationPercent ?? Constants.DEFAULT_FLUCTUATION_PERCENT);
- const phase2FluctuatedValue = currentPerPhaseSampledValueTemplates?.L2?.value
- && Utils.getRandomFloatFluctuatedRounded(parseInt(currentPerPhaseSampledValueTemplates.L2.value), currentPerPhaseSampledValueTemplates.L2.fluctuationPercent ?? Constants.DEFAULT_FLUCTUATION_PERCENT);
- const phase3FluctuatedValue = currentPerPhaseSampledValueTemplates?.L3?.value
- && Utils.getRandomFloatFluctuatedRounded(parseInt(currentPerPhaseSampledValueTemplates.L3.value), currentPerPhaseSampledValueTemplates.L3.fluctuationPercent ?? Constants.DEFAULT_FLUCTUATION_PERCENT);
- currentMeasurandValues.L1 = (phase1FluctuatedValue ?? defaultFluctuatedAmperagePerPhase) ?? Utils.getRandomFloatRounded(maxAmperage);
- currentMeasurandValues.L2 = (phase2FluctuatedValue ?? defaultFluctuatedAmperagePerPhase) ?? Utils.getRandomFloatRounded(maxAmperage);
- currentMeasurandValues.L3 = (phase3FluctuatedValue ?? defaultFluctuatedAmperagePerPhase) ?? Utils.getRandomFloatRounded(maxAmperage);
- } else {
- currentMeasurandValues.L1 = currentSampledValueTemplate.value
- ? Utils.getRandomFloatFluctuatedRounded(parseInt(currentSampledValueTemplate.value), currentSampledValueTemplate.fluctuationPercent ?? Constants.DEFAULT_FLUCTUATION_PERCENT)
- : Utils.getRandomFloatRounded(maxAmperage);
- currentMeasurandValues.L2 = 0;
- currentMeasurandValues.L3 = 0;
- }
- currentMeasurandValues.allPhases = Utils.roundTo((currentMeasurandValues.L1 + currentMeasurandValues.L2 + currentMeasurandValues.L3) / self.chargingStation.getNumberOfPhases(), 2);
- break;
- case CurrentType.DC:
- maxAmperage = DCElectricUtils.amperage(self.chargingStation.stationInfo.maxPower / self.chargingStation.stationInfo.powerDivider, self.chargingStation.getVoltageOut());
- currentMeasurandValues.allPhases = currentSampledValueTemplate.value
- ? Utils.getRandomFloatFluctuatedRounded(parseInt(currentSampledValueTemplate.value), currentSampledValueTemplate.fluctuationPercent ?? Constants.DEFAULT_FLUCTUATION_PERCENT)
- : Utils.getRandomFloatRounded(maxAmperage);
- break;
- default:
- logger.error(errMsg);
- throw Error(errMsg);
- }
- meterValue.sampledValue.push(OCPP16ServiceUtils.buildSampledValue(currentSampledValueTemplate, currentMeasurandValues.allPhases));
- const sampledValuesIndex = meterValue.sampledValue.length - 1;
- if (Utils.convertToFloat(meterValue.sampledValue[sampledValuesIndex].value) > maxAmperage || debug) {
- logger.error(`${self.chargingStation.logPrefix()} MeterValues measurand ${meterValue.sampledValue[sampledValuesIndex].measurand ?? OCPP16MeterValueMeasurand.ENERGY_ACTIVE_IMPORT_REGISTER}: connectorId ${connectorId}, transaction ${connector.transactionId}, value: ${meterValue.sampledValue[sampledValuesIndex].value}/${maxAmperage}`);
- }
- for (let phase = 1; self.chargingStation.getNumberOfPhases() === 3 && phase <= self.chargingStation.getNumberOfPhases(); phase++) {
- const phaseValue = `L${phase}`;
- meterValue.sampledValue.push(OCPP16ServiceUtils.buildSampledValue(currentPerPhaseSampledValueTemplates[phaseValue] ?? currentSampledValueTemplate,
- currentMeasurandValues[phaseValue], null, phaseValue as OCPP16MeterValuePhase));
- const sampledValuesPerPhaseIndex = meterValue.sampledValue.length - 1;
- if (Utils.convertToFloat(meterValue.sampledValue[sampledValuesPerPhaseIndex].value) > maxAmperage || debug) {
- logger.error(`${self.chargingStation.logPrefix()} MeterValues measurand ${meterValue.sampledValue[sampledValuesPerPhaseIndex].measurand ?? OCPP16MeterValueMeasurand.ENERGY_ACTIVE_IMPORT_REGISTER}: phase ${meterValue.sampledValue[sampledValuesPerPhaseIndex].phase}, connectorId ${connectorId}, transaction ${connector.transactionId}, value: ${meterValue.sampledValue[sampledValuesPerPhaseIndex].value}/${maxAmperage}`);
- }
- }
- }
- // Energy.Active.Import.Register measurand (default)
- const energySampledValueTemplate = self.chargingStation.getSampledValueTemplate(connectorId);
- if (energySampledValueTemplate) {
- OCPP16ServiceUtils.checkMeasurandPowerDivider(self.chargingStation, energySampledValueTemplate.measurand);
- const unitDivider = energySampledValueTemplate?.unit === MeterValueUnit.KILO_WATT_HOUR ? 1000 : 1;
- const energyMeasurandValue = energySampledValueTemplate.value
- // Cumulate the fluctuated value around the static one
- ? Utils.getRandomFloatFluctuatedRounded(parseInt(energySampledValueTemplate.value), energySampledValueTemplate.fluctuationPercent ?? Constants.DEFAULT_FLUCTUATION_PERCENT)
- : Utils.getRandomInt(self.chargingStation.stationInfo.maxPower / (self.chargingStation.stationInfo.powerDivider * 3600000) * interval);
- // Persist previous value on connector
- if (connector && !Utils.isNullOrUndefined(connector.energyActiveImportRegisterValue) && connector.energyActiveImportRegisterValue >= 0 &&
- !Utils.isNullOrUndefined(connector.transactionEnergyActiveImportRegisterValue) && connector.transactionEnergyActiveImportRegisterValue >= 0) {
- connector.energyActiveImportRegisterValue += energyMeasurandValue;
- connector.transactionEnergyActiveImportRegisterValue += energyMeasurandValue;
- } else {
- connector.energyActiveImportRegisterValue = 0;
- connector.transactionEnergyActiveImportRegisterValue = 0;
- }
- meterValue.sampledValue.push(OCPP16ServiceUtils.buildSampledValue(energySampledValueTemplate,
- Utils.roundTo(self.chargingStation.getEnergyActiveImportRegisterByTransactionId(transactionId) / unitDivider, 4)));
- const sampledValuesIndex = meterValue.sampledValue.length - 1;
- const maxEnergy = Math.round(self.chargingStation.stationInfo.maxPower * 3600 / (self.chargingStation.stationInfo.powerDivider * interval));
- const maxEnergyRounded = Utils.roundTo(maxEnergy / unitDivider, 4);
- if (Utils.convertToFloat(meterValue.sampledValue[sampledValuesIndex].value) > maxEnergyRounded || debug) {
- logger.error(`${self.chargingStation.logPrefix()} MeterValues measurand ${meterValue.sampledValue[sampledValuesIndex].measurand ?? OCPP16MeterValueMeasurand.ENERGY_ACTIVE_IMPORT_REGISTER}: connectorId ${connectorId}, transaction ${connector.transactionId}, value: ${meterValue.sampledValue[sampledValuesIndex].value}/${maxEnergyRounded}`);
- }
- }
- const payload: MeterValuesRequest = {
- connectorId,
- transactionId,
- meterValue,
- };
- await self.sendMessage(Utils.generateUUID(), payload, MessageType.CALL_MESSAGE, OCPP16RequestCommand.METER_VALUES);
- } catch (error) {
- self.handleRequestError(OCPP16RequestCommand.METER_VALUES, error);
+ private buildRequestPayload<Request extends JsonType>(
+ commandName: OCPP16RequestCommand,
+ commandParams?: JsonType
+ ): Request {
+ let connectorId: number;
+ switch (commandName) {
+ case OCPP16RequestCommand.AUTHORIZE:
+ return {
+ ...(!Utils.isUndefined(commandParams?.idTag)
+ ? { idTag: commandParams.idTag }
+ : { idTag: Constants.DEFAULT_IDTAG }),
+ } as unknown as Request;
+ case OCPP16RequestCommand.BOOT_NOTIFICATION:
+ return {
+ chargePointModel: commandParams?.chargePointModel,
+ chargePointVendor: commandParams?.chargePointVendor,
+ ...(!Utils.isUndefined(commandParams?.chargeBoxSerialNumber) && {
+ chargeBoxSerialNumber: commandParams.chargeBoxSerialNumber,
+ }),
+ ...(!Utils.isUndefined(commandParams?.chargePointSerialNumber) && {
+ chargePointSerialNumber: commandParams.chargePointSerialNumber,
+ }),
+ ...(!Utils.isUndefined(commandParams?.firmwareVersion) && {
+ firmwareVersion: commandParams.firmwareVersion,
+ }),
+ ...(!Utils.isUndefined(commandParams?.iccid) && { iccid: commandParams.iccid }),
+ ...(!Utils.isUndefined(commandParams?.imsi) && { imsi: commandParams.imsi }),
+ ...(!Utils.isUndefined(commandParams?.meterSerialNumber) && {
+ meterSerialNumber: commandParams.meterSerialNumber,
+ }),
+ ...(!Utils.isUndefined(commandParams?.meterType) && {
+ meterType: commandParams.meterType,
+ }),
+ } as unknown as Request;
+ case OCPP16RequestCommand.DIAGNOSTICS_STATUS_NOTIFICATION:
+ return {
+ status: commandParams?.diagnosticsStatus,
+ } as unknown as Request;
+ case OCPP16RequestCommand.HEARTBEAT:
+ return {} as unknown as Request;
+ case OCPP16RequestCommand.METER_VALUES:
+ return {
+ connectorId: commandParams?.connectorId,
+ transactionId: commandParams?.transactionId,
+ meterValue: Array.isArray(commandParams?.meterValue)
+ ? commandParams?.meterValue
+ : [commandParams?.meterValue],
+ } as unknown as Request;
+ case OCPP16RequestCommand.STATUS_NOTIFICATION:
+ return {
+ connectorId: commandParams?.connectorId,
+ status: commandParams?.status,
+ errorCode: commandParams?.errorCode,
+ } as unknown as Request;
+ case OCPP16RequestCommand.START_TRANSACTION:
+ return {
+ connectorId: commandParams?.connectorId,
+ ...(!Utils.isUndefined(commandParams?.idTag)
+ ? { idTag: commandParams?.idTag }
+ : { idTag: Constants.DEFAULT_IDTAG }),
+ meterStart: this.chargingStation.getEnergyActiveImportRegisterByConnectorId(
+ commandParams?.connectorId as number
+ ),
+ timestamp: new Date().toISOString(),
+ } as unknown as Request;
+ case OCPP16RequestCommand.STOP_TRANSACTION:
+ connectorId = this.chargingStation.getConnectorIdByTransactionId(
+ commandParams?.transactionId as number
+ );
+ return {
+ transactionId: commandParams?.transactionId,
+ ...(!Utils.isUndefined(commandParams?.idTag) && { idTag: commandParams.idTag }),
+ meterStop: commandParams?.meterStop,
+ timestamp: new Date().toISOString(),
+ ...(commandParams?.reason && { reason: commandParams.reason }),
+ ...(this.chargingStation.getTransactionDataMeterValues() && {
+ transactionData: OCPP16ServiceUtils.buildTransactionDataMeterValues(
+ this.chargingStation.getConnectorStatus(connectorId).transactionBeginMeterValue,
+ OCPP16ServiceUtils.buildTransactionEndMeterValue(
+ this.chargingStation,
+ connectorId,
+ commandParams?.meterStop as number
+ )
+ ),
+ }),
+ } as unknown as Request;
+ default:
+ throw new OCPPError(
+ ErrorType.NOT_SUPPORTED,
+ // eslint-disable-next-line @typescript-eslint/restrict-template-expressions
+ `${moduleName}.buildRequestPayload: Unsupported OCPP command: ${commandName}`,
+ commandName,
+ { commandName }
+ );
}
}
-
- public async sendTransactionBeginMeterValues(connectorId: number, transactionId: number, beginMeterValue: OCPP16MeterValue): Promise<void> {
- const payload: MeterValuesRequest = {
- connectorId,
- transactionId,
- meterValue: beginMeterValue,
- };
- await this.sendMessage(Utils.generateUUID(), payload, MessageType.CALL_MESSAGE, OCPP16RequestCommand.METER_VALUES);
- }
-
- public async sendTransactionEndMeterValues(connectorId: number, transactionId: number, endMeterValue: OCPP16MeterValue): Promise<void> {
- const payload: MeterValuesRequest = {
- connectorId,
- transactionId,
- meterValue: endMeterValue,
- };
- await this.sendMessage(Utils.generateUUID(), payload, MessageType.CALL_MESSAGE, OCPP16RequestCommand.METER_VALUES);
- }
-
- public async sendDiagnosticsStatusNotification(diagnosticsStatus: OCPP16DiagnosticsStatus): Promise<void> {
- const payload: DiagnosticsStatusNotificationRequest = {
- status: diagnosticsStatus
- };
- await this.sendMessage(Utils.generateUUID(), payload, MessageType.CALL_MESSAGE, OCPP16RequestCommand.DIAGNOSTICS_STATUS_NOTIFICATION);
- }
-
- public async sendError(messageId: string, error: OCPPError, commandName: OCPP16RequestCommand | OCPP16IncomingRequestCommand): Promise<unknown> {
- // Send error
- return this.sendMessage(messageId, error, MessageType.CALL_ERROR_MESSAGE, commandName);
- }
}