+libcec (2.2.0-1) unstable; urgency=low
+
+ * changed / added:
+ * read the physical address from X11 randr extension. credits: @smithereens
+ * support for Exynos HDMI. credits: @vamanea
+ * another vendor ID for Harman/Kardon. credits: @ksooo
+ * some 1.4 keycodes have been added. credits: @ksooo
+ * cec-client: fix typo prevent keycodes to be passed. credits: @popcornmix
+
+ * fixed:
+ * various Raspberry Pi fixes. credits: @mk01
+ * vendor specific handlers weren't used for Toshiba and Onkyo.
+ credits: @ksooo
+ * LibCecTray: keypress not sent when multiple instances of eshell.exe are
+ running. thanks @pvanbaren
+ * deadlock on exit in XBMC, because of CEC_ALERT_CONNECTION_LOST
+
+ -- Pulse-Eight Packaging <packaging@pulse-eight.com> Tue, 28 Oct 2014 10:45:00 +0200
+
+libcec (2.1.4-2) unstable; urgency=low
+
+ * fixed:
+ * OS X build
+
+ -- Pulse-Eight Packaging <packaging@pulse-eight.com> Wed, 18 Dec 2013 02:14:00 +0100
+
+libcec (2.1.4-1) unstable; urgency=low
+
+ * changed / added:
+ * set the vendor id of devices handled by libCEC to our vendor id
+ * added protection against standby without a notification from XBMC and
+ clock changes. issue #186
+ * update system audio mode when audio system devices are activated
+ * added vendor id and name 'Harman/Kardon'
+ * added vendor id and name 'Marantz'
+ * cec-tray: support for away mode
+ * cec-tray: support for screensaver events
+ * fixed:
+ * fixed potential crash when SendCommand returns NULL
+ * fixed crash when CCECProcessor::Transmit was called after
+ CCECProcessor::Close
+ * always call the SourceActivated() callback in
+ CCECBusDevice::MarkAsActiveSource(), even when we were already active,
+ and let clients handle dupes. this prevented the screensaver from
+ being cancelled in XBMC
+ * send our vendor id when the tv sends it's vendor id
+ * transmit our physical address when the TV sends it's physical address
+ * potential deadlock
+ * leak on exit in CWaitForResponse::Clear()
+ * also transmit an active source message as response to a set stream path
+ command when we were already marked as active. bugzid: 3116
+ * only send an active source message when receiving a routing change to an
+ address handled by libCEC. issue #56
+ * HandleVendorRemoteButtonUp -> HandleUserControlRelease for all vendors
+ * silence warning for xx:a0:00:09:b0:00:80:20. bugzid: 2559
+ * fixed comboKeyTimeout=0. closes #168
+ * Panasonic: doesn't request the active source status when powered up, but
+ it does send a vendor command. send an active source message when we're
+ marked as active source after receiving this command. issue #192
+ * possible crash when the tv does not respond to polls and the client isn't
+ registered yet. don't poll the tv in monitoring mode. closes #163
+ * Panasonic: standby command
+ * Panasonic: silence 'unmapped code' warning. bugzid: 2375
+ * LG: clean up and attempt to fix issue #176
+ * LG: newer firmwares don't send a second power status request after it's
+ been requested once and replied with 'standby -> on' like previous
+ versions. send an active source message in an attempt to fix this. issue:
+ #176
+ * Sharp: check whether the 'auto power on' option is disabled and tell the
+ user how to enable it
+ * Samsung: respond to vendor command 0x23 sent by samsung. attempt to fix
+ bugzid: 2164
+ * cec-client: try to reconnect when the connection was lost
+ * cec-tray: crash on load (MissingManifestResourceException)
+ * cec-tray: crash or deadlock on exit
+ * cec-tray: crash when the connection to the adapter was lost
+ * cec-tray: display TV not responding warning on top
+ * windows: build libCEC and cec-client against toolset v100 (VS2010)
+ * FreeBSD: proper the adapter detection. credits @fneufneu
+ * suppress mangling warning. credits @warped-rudi. closes #190
+
+ -- Pulse-Eight Packaging <packaging@pulse-eight.com> Sat, 13 Dec 2013 16:02:00 +0100
+
+libcec (2.1.3-1) unstable; urgency=low
+
+ * changed / added:
+ * ask users to send an email when receiving an unhandled vendor command
+ * toshiba: map top menu and dvd menu buttons. closes #148
+ * LibCecSharp: sync alert types
+ * LibCecSharp: added CurrentVersion to the version enum
+ * CecSharpClient: use CurrentVersion instead of a hardcoded version
+ * CecTray: power management
+ * CecTray: split up asyncform
+ * CecTray: try/catch xml exceptions when reading the xml config. bugzid:
+ 2082
+ * CecTray: use CurrentVersion instead of a hardcoded version
+ * CecTray: display a warning if we can't poll the TV
+ * CecTray: display alerts from libCEC
+ * CecTray: don't use lazy loading for the main controller, but pass the
+ instance. bugzid: 2082
+ * windows: converted to vs2012
+ * fixed:
+ * toshiba: toshiba handler wasn't initialised, and toshiba uses more than
+ one vendor id
+ * libCEC marked itself as inactive source when the stream path changed to
+ a device with a different physical address. bugzid: 2157
+ * TDA995x: report proper firmware revision (credits: @warped-rudi)
+ * TDA995x: avoid callback when already stopped (credits: @warped-rudi)
+ * windows: fix resource files and backwards compat dll names
+
+ -- Pulse-Eight Packaging <packaging@pulse-eight.com> Sat, 11 May 2013 10:06:00 +0000
+
+libcec (2.1.1-1) unstable; urgency=low
+
+ * changed / added:
+ * send an alert when the TV does not respond to polls
+ * fixed:
+ * LG didn't switch sources after the TV powered up
+ * always poll a device when the status is unknown, and don't try to
+ determine whether it needs to be polled by checking the status of other
+ devices
+ * don't mark a device as inactive when receiving a routing change message,
+ only when another device was made acive. fixes the issue that rc
+ passthrough doesn't work when a tv sends a quick routing change to
+ another port before requesting the active source when coming out of
+ standby
+ * LibCecSharp: fixed 14 char long OSD name (wasn't \0 terminated)
+ * LibCecSharp: fixed return value of GetActiveDevices(). issue #131
+ * cec-tray: fixed index out of range exception in CECSettingNumeric.cs.
+ bugzid: 2082
+ * cec-tray: ensure that the tray app only initialises once. bugzid: 2082
+ * rpi: don't set the physical address to 1.0.0.0 when receiving
+ VC_HDMI_UNPLUGGED. it may wake up device when they were just sent to
+ standby. issue #142
+ * osx: use the correct dylib name in cecloader.h, used by cec-client
+
+ -- Pulse-Eight Packaging <packaging@pulse-eight.com> Fri, 8 Mar 2013 17:21:00 +0100
+
+ libcec (2.1.0-1) unstable; urgency=low
+
+ * changed / added:
+ * added vendor id for Denon
+ * added DetectAdapters() method, that returns all device information for
+ detected adapters, not just the com port
+ * added new method PowerOnScreensaver. credits: @jmarcet
+ * LibCECTray: Added ability to send modifiers by nesting commands in
+ KeyInput.cs. credits: Nate Burr
+ * rpi: Added /opt/vc/include/interface/vmcs_host/linux to rpi_cflags to fix
+ building on 'next' firmware branch. credits: Nedim Lisica
+ * fixed:
+ * don't send two active source message sequences to philips. issue #118
+ * don't send deck status updates to philips when activating the source
+ * update the active source status correctly after a manual switch to
+ another source. closes #124
+ * rename cec_audio_status() to cec_audio_get_status() to avoid conflict
+ with the cec_audio_status enum. This makes the C API compile again.
+ credits: Dave Chapman
+ * LibCECTray: Fixed bug with libcec adding the keyup for button commands
+ and making sure they are still executed. credits: Nate Burr
+ * rpi: register callback for HPD. re-read the physical address when we
+ received VC_HDMI_ATTACHED. issue #109
+
+ -- Pulse-Eight Packaging <packaging@pulse-eight.com> Tue, 26 Feb 2013 23:06:00 +0100
+
+libcec (2.0.5-1) unstable; urgency=low
+
+ * changed:
+ * also try polls at least twice when it failed
+ * added methods to get the audiostatus and toggle the mute status from the
+ amplifier (if connected)
+ * added comboKey and iComboKeyTimeoutMs to libcec_configuration
+ * force cec_user_control_code_unknown to 0xFF
+ * fixed:
+ * check unsupported features properly
+ * only send an active source message when the stream path changed and we
+ weren't the active source yet
+ * don't mark as inactive source on routing changes
+ * press & hold
+ * never mark user control opcodes as unsupported
+ * report our OSD name to the TV, since some TVs don't request it
+ * initial audiostatus value
+ * don't log a no longer relevant FIXME
+
+ -- Pulse-Eight Packaging <packaging@pulse-eight.com> Thu, 6 Dec 2012 20:58:00 +0100
+
+libcec (2.0.4-1) unstable; urgency=low
+
+ * changed:
+ * dropped obsolete cec-config
+ * added CEC_CLIENT_VERSION_CURRENT and CEC_SERVER_VERSION_CURRENT. closes
+ #88
+ * support colon separated data for the 'tx' command in cec-client
+ * mark the adapter as (in)active source for firmware v3+
+ * added 'is' command to cec-client, to mark libCEC as inactive source
+ * fixed:
+ * only change the handler of the primary device if the tv has a quirks mode
+ not for other devices
+ * send an active source message when the route was set to the physical
+ address that is handled by libCEC
+ * default double tap timeout wasn't set for panasonic
+ * philips TVs sometimes keep sending key presses without key releases
+ * philips TVs ignore 'image view on' right after they were sent into
+ standby. check the power status of the tv every 5 seconds, until it
+ reports to have powered on
+ * mark a device as powered on when receiving a stream path or routing
+ change
+ * update the active source status correctly on stream path changes
+ * ensure that we only send 'image view on' when needed
+ * mark the TV as 'in transition standby -> on' after sending
+ 'image view on', so we don't spam the TV with 'image view on' command
+ while waiting for it to finish powering up. bugzid: 1603. bugzid: 1609.
+ bugzid: 1592
+ * request the active source before requesting device information in
+ cec-client, or it'll display incorrect information when called the first
+ time
+ * update the value of CCECProcessor::m_bMonitor when registering a client.
+ SetControlled() wasn't called on exit, so it took 30 seconds until it was
+ auto-enabled
+ * silence 'unused' warning properly. closes #86
+ * only change the type of the client to 'playback device' instead of
+ 'recorder' for panasonic if the TV is a panasonic. issue #84
+ * always poll the TV if it's marked as not present. issue #83. issue #84
+ * only set m_iCurrentButton when the duration isn't known yet. fixes
+ duplicate key press for vendor remote codes. closes #81
+ * delete the right registry key
+ * send active source message when we received a routing change with a
+ device that is handled by libCEC as address. issue #89
+ * return value wasn't updated in GetLogicalAddresses()
+
+ -- Pulse-Eight Packaging <packaging@pulse-eight.com> Thu, 15 Nov 2012 02:26:00 +0100
+
+libcec (2.0.3-1) unstable; urgency=low
+
+ * changed:
+ * log unhandled vendor remote keycodes in the log, so they get logged
+ without debugging enabled
+ * double tap timeout increased from 200ms to 250ms
+ * CuBox/NXP* renamed to TDA995x*
+ * fixed:
+ * handling of active route changes. github issue #56 and issue #58
+ * new combo key handling broke samsung's vendor specific remote buttons.
+ github issue #54
+ * don't try to set controlled mode when using firmware version 1 and crash.
+ github issue #76
+ * fix for LG models that send a vendor key up after a normal key down.
+ github issue #71
+ * some TVs send keypresses to us without making us the active source. mark
+ us as active source when this happens. github issue #71
+ * LG doesn't send routing changes, and marks the TV as active source when
+ switching to another source that's not been selected in the simplink menu
+ instead. this change keeps libCEC marked as powered on and keep the deck
+ state set to CEC_DECK_INFO_OTHER_STATUS_LG. fixes keypresses not working
+ after switching to another source and back to libCEC's hdmi port via the
+ source select menu instead of the simplink menu. github issue #71
+ * don't respond with an abort message when receiving a vendor remote button
+ command
+ * respond with CEC_ABORT_REASON_INVALID_OPERAND when receiving a keypress
+ without a parameter
+ * typo in stop+pause combo key that prevented one of the keys from working
+ * rpi: log what data we received exactly when we receive an response from
+ the pi's firmware that doesn't match any command that we sent. issue #77
+ * cubox: added adapter ID interface
+
+ -- Pulse-Eight Packaging <packaging@pulse-eight.com> Wed, 31 Oct 2012 15:57:00 +0100
+
+libcec (2.0.2-2) unstable; urgency=medium
+
+ * fixed:
+ * updating the device status after a poll was broken and could reset the
+ status of devices that were marked as handled by libCEC to 'not
+ present'
+ * don't keep spamming the bus with a vendor command when an active source
+ switch is pending for panasonic, but only send it when needed
+ * reset CVLCommandHandler::m_bCapabilitiesSent when the TV goes to standby
+
+ -- Pulse-Eight Packaging <packaging@pulse-eight.com> Mon, 15 Oct 2012 13:52:00 +0100
+
+libcec (2.0.2-1) unstable; urgency=low
+
+ * changed/added:
+ * missing from the previous changelog: added support for the CuBox TDA995x
+ credits: warped-rudi
+ * lower retry timeout for source switches
+ * cec-client: wait for the source switch to finish when cec-client is
+ called with the -s switch
+ * request the power status of the TV directly after registering a new
+ client
+ * fixed:
+ * don't keep trying to send 'image view on' commands to the TV when no TV
+ is connected, and just send the 'set active source' command. fixes source
+ switch and debug log spam for people without a TV connected
+ * don't keep waiting for an updated power status from the TV for Panasonic,
+ but request a status update once every 5 seconds, or we can possibly wait
+ forever for the tv to send it
+ * log what we received exactly when logging FIXME
+ * typo in CVLCommandHandler::VendorPreActivateSourceHook. bugzid: 1087
+ * if we failed to get the physical address of the device that we are
+ connected to in the config, then try to use the address that was
+ persisted in the eeprom before resetting to the default value, 1.0.0.0.
+ closes #50.
+ * don't update the device status of unregistered/broadcast
+ * log all device status changes
+ * CCECClient::IsLibCECActiveSource returns false now while the active
+ source command is pending
+ * log failed acks and other errors in the debug log again
+ * don't send 'image view on' when the TV is already powering up
+ * reset the delayed source switch timeout properly, so we don't spam
+ commands every second
+ * don't change the device status when sending a delayed source switch
+ * don't send out commands to a device that is marked as not present or
+ handled by libCEC
+
+ -- Pulse-Eight Packaging <packaging@pulse-eight.com> Thu, 11 Oct 2012 15:48:00 +0100
+
+libcec (2.0.1-1) unstable; urgency=low
+
+ * changed/added:
+ * added Loewe support
+ * added signal handlers to client applications
+ * Documentation updated
+ * replaced cec-config-gui by libCEC tray
+ * log the exact data for failed transmissions, not the opcode
+ * don't log every frame, unless debugging was enabled in ./configure or
+ visual studio
+ * changed some log levels from NOTICE to DEBUG, so the non-debugging output
+ is less spammy
+ * interface changes:
+ * WARNING: breaking API changes
+ * clean up: deprecated methods and fields removed
+ * callback parameters changed to fix plain C compilation
+ * added GetAdapterProductId()+GetAdapterVendorId()/
+ cec_get_adapter_product_id()+cec_get_adapter_vendor_id()
+ * added iDoubleTapTimeoutMs to libcec_configuration
+ * remove all pre-v2.0 compatibility checks
+ * fixed:
+ * fix plain C compilation
+ * prevent sending directly addressed commands from being sent to broadcast
+ * don't wait for a response when sending a reply, so we don't block message
+ handling
+ * message response signaling and logging
+ * prevent double taps by not sending the same key press twice within 200ms
+ * fall back to the primary client when
+ CCECProcessor::HandleLogicalAddressLost() and no client could be found
+ * no more delay up to 2 seconds when exiting libCEC
+ * don't get caught in a loop in CVLCommandHandler when the source switch
+ was not allowed and no power status request was sent
+ * always send image view on to the tv, don't check the power status
+ * only respond to vendor commands for panasonic if we are the destination
+ * rpi: current firmware first sends a change to logical address 'broadcast'
+ and then signals us that the address was lost. libCEC then failed to
+ re-register, because it didn't know any client at this address
+
+ -- Pulse-Eight Packaging <packaging@pulse-eight.com> Mon, 8 Oct 2012 21:30:00 +0100
+
+libcec (1.9.1-1) unstable; urgency=low
+
+ * changed/added:
+ * added the type of adapter to libcec_configuration,
+ and display the type in cec-client -l
+ * added device detection support for composite usb devices on windows.
+ needs the windows ddk, and it's expected to be found in
+ C:\WinDDK\7600.16385.1
+
+ * interface changes:
+ * adapter type was added to libcec_configuration
+ * moved cec_adapter_messagecode from cectypes.h to USBCECAdapterMessage.h
+
+ * fixed:
+ * retry m_port->Read(..) if an EINTR errror occurs instead of closing the
+ connection. credits @Obruni. closes #38
+ * make cec-client include cecloader.h from our project, not from system
+ * fixed duplicate entries check in CUSBCECAdapterDetection
+ * fixed missing cec_version updates in libcec_configuration
+ * transmit an active source message after <set stream path> to a device
+ that's handled by libCEC. closes #43
+ * rpi: handle vendor specific remote control presses. closes #42
+ * rpi: handle VC_CEC_LOGICAL_ADDR_LOST, sent by the Pi's firmware when
+ the logical address was taken while CEC was being reinitialised
+ * panasonic: send out an active source message when the tv started up
+ because it sometimes doesn't request this
+
+ -- Pulse-Eight Packaging <packaging@pulse-eight.com> Wed, 5 Sep 2012 16:54:00 +0100
+
+libcec (1.8.2-1) unstable; urgency=low
+
+ * changed/added:
+ * p8: match to the response provided by the firmware when checking
+ responses (added in firmware v2 rev6)
+
+ * fixed:
+ * windows: update the error message when an error occurs while writing to
+ the serial port
+ * delayed source switch time was reset, resulting in an attempt every
+ second until it succeeded
+ * ensure that the vendor commands are always sent for panasonic, and that
+ the deck status for lg isn't reset. fixes some buttons not working after
+ a second or delayed source switch
+ * added guard so ReplaceHandler() doesn't accidently try to replace a
+ handler for the broadcast address
+ * wait until the commandhandler is replaced before registering a client,
+ so we don't register a client and replace it directly afterwards if the
+ tv doesn't support the device type
+ * ensure that the command handler of the tv is replaced before registering
+ a client, or it might result in a double eeprom write attempt
+ * p8: don't disable controlled mode when switching to monitoring mode
+ * p8: do delayed eeprom writes async or it'll block processing other input
+
+ -- Pulse-Eight Packaging <packaging@pulse-eight.com> Tue, 3 Aug 2012 02:35:00 +0100
+
+libcec (1.8.1-1) unstable; urgency=low
+
+ * changed/added:
+ * added support for the Raspberry Pi.
+ * added cec-client -i / cec-client --info that calls GetLibInfo()
+ * header cleanups
+ * added CAdapterFactory, to create IAdapterCommunication instances
+ * added --debug to configure, to include -ggdb
+
+ * interface changes:
+ * added GetLibInfo()/cec_get_lib_info(), that shows how libCEC was compiled
+ and with which features included.
+ * added ToString(cec_user_control_code_key) to the interface
+
+ * fixed:
+ * disallow sending CEC_OPCODE_SET_STREAM_PATH - not allowed by the CEC spec
+ * persist the configuration in the eeprom after initialising the client.
+ fixes wrong/old settings being used in autonomous mode, which broke the
+ wake on cec funtion
+ * persist the new configuration when the hdmi port setting changed
+ * cleaned locks around callbacks
+ * always set controlled mode to false when unregistering the last client.
+ fixes 30 second timeout before controlled mode gets deactivated
+ * updated the cached device type setting properly when persisting new
+ settings. correct return value from WriteEEPROM(). lock a mutex when
+ updating the state
+ * LibCecSharp: set the primary LA in CecLogicalAddresses
+
+ -- Pulse-Eight Packaging <packaging@pulse-eight.com> Tue, 25 Jul 2012 13:05:00 +0100
+
+libcec (1.7.2-1) unstable; urgency=low
+
+ * changed/added:
+ * display a warning message if libCEC was not compiled with adapter
+ detection for the target platform
+ * panasonic: added a vendor command for panasonic that will enable routing
+ of some more buttons on the remote (guide, text, ...)
+ * standby command won't be forwarded more than once every 10 seconds
+ * added vendor ids for Akai, AOC, Benq, Daewoo, Grundig, Medion, Sharp and
+ Vizio
+ * cec-client: don't display debug output by default in 'cec-client -l'
+
+ * interface changes:
+ * added a callback for clients that is called when a source is
+ (de)activated, so the client can respond to this action
+ * added cec_command::PushArray()
+
+ * fixed:
+ * command forwarding. fixes player not going into standby mode
+ * missing virtual keyword in CCECCommandHandler::
+ GetReplacementDeviceType()
+ * replace the handler (if needed) in GetHandler()
+ * reply with abort reason 'invalid operand' to vendor commands that we
+ don't understand
+ * changed all Handle...() commands to return a cec_abort_reason and send
+ the correct abort reason to the initiator as a response to directly
+ addressed messages
+ * changed 'couldn't change the ackmask: the connection is closed' into a
+ debug message
+ * don't send active source commands when the physical address is invalid or
+ unknown
+ * set the power status of a device to 'powered on' after it sends a stream
+ path change. can save an unneeded power state update request
+ * removed dupe code around delayed activate source commands. check for
+ delayed active source commands every 5 seconds instead of 15 seconds.
+ * panasonic: reset m_bPowerUpEventReceived in CVLCommandHandler when the
+ device lets us know it went into standby mode. fixes possibly failed
+ active source switches after it succeeded once
+ * panasonic: fixed delayed source switch for panasonic
+ * panasonic: mark the tv as powered up once it sends the audiomode request
+ * set the physical address of each device controlled by a CCECClient if
+ it's valid
+ * Windows could get stuck in a loop in case there an error occured while
+ reading registry entries
+ * ABI fixes (binary compat with v1.2 for Windows and v1.5.2 for others)
+ * replace the handler directly after getting the vendor id of a device when
+ registering a client
+ * copy the class member values of the old handler when creating a new
+ command handler, or a delayed activate source will get lost when the
+ handler is switched
+ * cec-client: wrong client version
+ * Makefile cleanups. don't link cec-client and cec-config against libudev
+ and liblockdev
+ * pin libcec to the same version as libcec1
+ * LibCecSharp: update the local configuration after connecting
+ * LibCecSharp: better handling of callbacks
+
+ -- Pulse-Eight Packaging <packaging@pulse-eight.com> Wed, 27 Jun 2012 02:06:00 +0100
+
+libcec (1.7.1-1) unstable; urgency=low
+
+ * changed/added:
+ * added physical address detection via ADL for AMD graphics cards
+ * attempt to get the edid from nvidia's graphics card driver on linux via
+ /proc/acpi/video/NGFX/HDMI/EDID
+ * attempt to get the PA from the registry on windows if we fail to get the
+ physical address from the display driver
+ * changed the order in CCECClient::SetPhysicalAddress() so it first checks
+ whether a PA override is set in libcec_configuration.iPhysicalAddress,
+ then checks whether the address can be detected, and if both failed it'll
+ use the HDMI port + base device setting
+ * cec-client: only active the source when reconnecting if libcec was the
+ active source before closing the connection
+ * platform: added tcp server sockets for posix
+
+ * interface changes:
+ * libcec_configuration.bAutodetectAddress is now read-only, and will be set
+ to 1 by libCEC if the PA was autodetected
+ * LibCecSharp: don't use an int but a CecUserControlCode in a CecKeypress
+
+ * fixed:
+ * don't unregister clients in CLibCEC when disconnecting, but only in
+ CCECProcessor. fixes reconnect after close
+ * MSGCODE_TIMEOUT_ERROR is a response to a transmission
+ * retry 'activate source' every 10 seconds if it failed
+ * don't respond with a poll from the broadcast address when receiving
+ in CSLCommandHandler::HandleDeviceVendorId(), but use the primary LA of
+ the client as source instead
+ * hold a lock when changing the ackmask in
+ CUSBCECAdapterCommunication::Open
+ * don't respond with a feature abort to opcode play messages. bugzid: 873
+ * get the vendor id of the TV before allocating logical addresses, so we
+ can determine if the TV supports the requested device type directly
+ * TransmitImageViewOn() and TransmitActiveSource() always returned true,
+ even if sending the command failed, so the retry for failed source
+ activations was never triggered
+ * open libcec.so.1 instead of libcec.so in cecloader.h. credits @coling.
+ github issue #30.
+ * fixed missing firmware version and build date in cec-client -l /
+ GetDeviceInformation()
+
+ -- Pulse-Eight Packaging <packaging@pulse-eight.com> Sun, 10 Jun 2012 13:39:00 +0100
+
+libcec (1.6.1-5) unstable; urgency=low
+
+ * synced /debian directory with the one in precise (with a couple of changes)
+ * changed/added:
+ * serial port locking on linux
+ * cec-client: added -m/--monitor startup options, which will start a
+ monitor-only client. use 'mon 0' to switch to a normal client
+ * display an alert message when the firmware of the adapter can be upgraded
+ * added CEC 1.4 opcodes
+ * send a feature abort again for all unhandled commands
+ * refactored CLibCEC so a client registers itself within CCECProcessor,
+ which then allocates one or more logical addresses for it.
+
+ * interface changes:
+ * added a new setting, bMonitorOnly, which will start a monitor-only client
+
+ * fixed:
+ * ensure that we don't crash out when trying to stop a thread that hasn't
+ been started yet
+ * don't send a 'disconnected' alert when the close method is called
+ * use the correct source when transmitting an abort message as a reposonse
+ to a vendor command with id
+ * removed statics
+ * check the client version, not the server version in
+ libcec_configuration::operator==()
+ * cec-config: fix physical address detection
+ * LibCecSharp: fixed buffer overrun when copying libcec_configuration.
+ fixes crash when trying to save the configuration in the config gui.
+
+ -- Pulse-Eight Packaging <packaging@pulse-eight.com> Mon, 14 May 2012 22:39:00 +0100
+
+libcec (1.6.1-2) unstable; urgency=low
+
+ * Build depends on pkg-config. (Closes: #669919)
+ * libudev-dev only optionally needed for Linux.
+
+ -- Andres Mejia <amejia@debian.org> Sat, 21 Apr 2012 19:03:19 -0400
+
+libcec (1.6.1-1) unstable; urgency=low
+
+ [ Mario Limonciello ]
+ * New upstream version (LP: #982272)
+
+ [ Andres Mejia ]
+ * New release fixes build failure with GCC-4.7. (Closes: #667241)
+ * Bump to Standards-Version 3.9.3.
+
+ -- Andres Mejia <amejia@debian.org> Sat, 21 Apr 2012 00:02:08 -0400
+
+libcec (1.3.2-3) unstable; urgency=low
+
+ * Make dpkg-source options default for packaging.
+
+ -- Andres Mejia <amejia@debian.org> Tue, 10 Jan 2012 18:12:57 -0500
+
+libcec (1.3.2-2) unstable; urgency=low
+
+ * Add options to pass to dpkg-source.
+
+ -- Andres Mejia <amejia@debian.org> Sun, 08 Jan 2012 22:59:34 -0500
+
+libcec (1.3.2-1) unstable; urgency=low
+
+ * Initial release. (Closes: #655143)
+
+ -- Andres Mejia <amejia@debian.org> Sun, 08 Jan 2012 15:36:49 -0500
+
+libcec (1.6-3) unstable; urgency=low
+
+ * changed/added:
+ * cec-client: show the firmware build date if available in cec-client -l
+ * cec-client: don't activate the source when starting
+ * cec-client: group up the output of the 'scan' command, and add the
+ currently active source to the output
+ * log the libCEC version in the 'connected to the CEC adapter' log entry,
+ and add the firmware build date to the line if it's available, so all
+ relevant version info is available in 1 log line.
+ * async writes for CUSBCECAdapterCommunication. less locks and polls, more
+ speed
+ * added 'make docs' target, that updates the doxygen documentation
+
+ * interface changes:
+ * added operator == and != for libcec_configuration
+ * added GetResponseOpcode(cec_opcode opcode) to cec_command
+ * added the firmware build date to libcec_configuration, so it can be
+ displayed by the client too.
+ * added static CLibCEC::Alert() method and CEC_ALERT_CONNECTION_LOST value
+ * added a callback to handle menu state changes. if the callback method
+ returns 1, then the change is processed by the CCECBusDevice too. if 0,
+ then the CCECBusDevice will always have menu state 'activated', so
+ keypresses are routed. bugzid: 724
+ * added a default menu language to libcec_configuration and set this
+ language for devices controlled by libcec. bugzid: 69
+
+ * fixed
+ * CCECProcessor::IsActiveSource() - TV was never checked
+ * don't call the deprecated SetActiveView() method in cec-client
+ * request the active source if unknown in CCECProcessor::GetActiveSource()
+ * don't try to match a device with PA 0xFFFF.
+ * don't change the power status of a device when changing the stream path
+ * don't set the power status to 'powered off' when marking the source
+ managed by libcec as inactive, or the tv will might send a power control
+ keycode when making it active again, potentially shutting down the system
+ * potential segfault in CCECProcessor::GetDeviceByPhysicalAddress()
+ * stream path changes when changed to the TV source (PA 0)
+ * clear the unsupported features list in CCECBusDevice::ResetDeviceStatus()
+ * never mark vendor commands as unsupported (only some may be unsupported),
+ as well as some others that should never be marked unsupported
+ * don't retry in CCECCommandHandler if the command has been marked as
+ unsupported
+ * don't request the PA of devices when handling an incoming CEC command, or
+ it'll block things while waiting for a response. if that response never
+ comes, or comes late, then other incoming commands will be timed out
+ before they are handled
+ * optimisation - strip unneeded virtual keywords from top level
+ implementations
+ * use the vlcommandhandler for the primary device that is handled by libCEC
+ when a panasonic tv is detected, so delayed activate source commands are
+ using the correct handler. bugzid: 723
+ * set the power status of device controlled by libCEC to
+ CEC_POWER_STATUS_ON
+ instead of IN_TRANSITION_STANDBY_TO_ON. reset the device status of a
+ device if it was detected as removed. bugzid: 755
+ * potentially uninitialised values in cec_command
+ * delay the 'active source' command for panasonic, until the vendor command
+ that reports that the TV is powered on has been received. bugzid: 723
+ * only respond to Give Physical Address with Report Physical Address.
+ bugzid: 592
+ This fixes several reports of the TV improperly switching to the libcec
+ device after it has previously switched to another source. Fix confirmed
+ with Panasonic and also reported to be an issue with Samsung and
+ Philips.
+ * check whether callback methods are set to a valid ptr
+ * number of retries for polls
+ * win32: fix build in paths with spaces. bugzid: 730
+ * LibCecSharp: free the alert GC callback when cleaning up
+ * the wrong setting was being read when powering on devices
+ * close the connection when a comm error was detected, and notify the
+ client via an alert
+ * don't segfault when calling ThreadsWait() without a valid thread
+ * lib/platform: fixed memleak
+ * leak in CCECAdapterMessageQueue::Write
+ * don't send commands if we know them to be unsupported. bugzid: 725
+
+ -- Pulse-Eight Packaging <packaging@pulse-eight.com> Wed, 18 Apr 2012 11:30:00 +0100
+
+libcec (1.6-2) unstable; urgency=low
+
+ * fixed:
+ * fixed typo in CUSBCECAdapterCommands::RequestSettings() that prevented
+ the settings from being read. the settings were still written, but never
+ read when bGetSettingsFromROM = 1.
+
+ -- Pulse-Eight Packaging <packaging@pulse-eight.com> Wed, 18 Apr 2012 11:30:00 +0100
+
+libcec (1.6-1) unstable; urgency=medium
+
+ * changed/added:
+ * full firmware V2 support
+ * -o/--osdname argument for cec-client to set a custom osd name
+ * added the firmware version to cec-client's -l / --list-devices command.
+ bugzid: 631
+ * added power on command for Samsung AVR devices. bugzid: 361
+ * added buttoncode for 'channels list' on Samsung (0x96)
+ * don't check for the windows ddk when a prebuilt driver installer is
+ present
+ * respond to Get Menu Language. bugzid: 547. In the event that the menu
+ language is undefined in libcec (currently the default), the response
+ will be a feature abort.
+
+ * interface changes:
+ * added the firmware version to libcec_configuration (read-only). bumped
+ server version to 1.6.0. fixed 'unknown server version' message on
+ startup. bugzid: 631
+ * added a new setting to control whether to put the TV in standby when the
+ player is put in standby. added some missing bits (version numbers,
+ config) to LibCecSharp. bugzid: 558
+ * added an alert callback. bugzid: 462
+ * added bShutdownOnStandby to libcec_configuration. bugzid: 660. This
+ setting tells the client to shutdown when the TV switches off and is
+ complimentary to bPowerOffOnStandby, which tells the PC to suspend.
+ They are kept separate to maintain backwards compatability.
+
+ * fixed
+ * gcc 4.7 compilation
+ * poll doesn't have an opcode. bugzid: 591
+ * wait for MSGEND when data was received when opening the connection.
+ bugzid: 536
+ * mark the correct device as active source after a stream path change.
+ if the new address is not found, but the old address is, then mark the
+ old address as inactive. fixes TV switching back to the old active source
+ when it scans for devices. bugzid: 592
+ * ensure that the vendor ID is sent before trying to activate any SL device
+ bugzid: 574
+ * fixed possible crash when in CLibCEC::IsLibCECActiveSource() when libCEC
+ doesn't know which device is the active source. bugzid: 479
+ * correct handling CEC_USER_CONTROL_CODE_POWER. This ensures that the power
+ code always operates as a toggle, depending on the current state, and
+ that SetCurrentButton is always called for a valid user control code.
+ bugzid: 570
+ * frequency wasn't checked in GetTimeMs(), leading to incorrect wait times
+ on some windows systems
+ * refactored USB adapter communication. less locks, shorter locks, added
+ documentation, lots of clean ups and no more incoming messages that are
+ skipped
+ * the destructor of CSerialSocket didn't call Close()
+ * added guards in CSerialPort
+ * reset m_socket to INVALID_SERIAL_SOCKET_VALUE after closing the
+ connection
+ * always wait for thread exit in CThread's desctructor
+ * crash on exit after GetDeviceInformation()
+ * check whether the destination is valid before setting anything in
+ m_bWaitingForAck. fixes heap corruption and crash on exit. bugzid: 479
+ * bUseTVMenuLanguage from libcec_configuration wasn't copied in
+ SetConfiguration(), so this setting was reset to the default value
+ (enabled) every time. bugzid: 617
+ * request the vendor id of a device if needed when the device status is
+ changed into 'present'. bugzid: 361
+ * give priority to messages from the TV. removed the global lock in
+ CCECProcessor when sending. this is no longer needed. bugzid: 238
+ * add some bounds checking to the HDMI port number. bugzid: 508
+ * fixed usbser.sys copying in the driver .INF. bugzid: 503
+ * only update the physical address when it has actually changed. bugzid:
+ 672
+ * moved the static variables in os-threads from the header to a separate
+ cpp file, or it could lead to problems when included multiple times
+ * don't send an active source command when the physical address couldn't be
+ set, or it might confuse other CEC devices
+ * serial socket timeouts. bugzid: 654
+ * fixed possible crash when trying to request a vendor id of a device when
+ the address of libCEC isn't known yet. bugzid: 654
+ * extra guard so no commands are transmitted without a valid initiator.
+ bugzid: 654
+ * moved the timed ping to a separate thread. bugzid: 654
+ * persist settings directly when they're changed, only persist settings
+ that actually changed, only instruct the device to persist the settings
+ in eeprom when something changed, and don't persist settings on exit.
+ bugzid: 715
+ * cec-config-gui: persist settings both in the eeprom and in the settings
+ xml file
+ * validate the input in CCECProcessor::IsActiveSource(). fixes potential
+ crash when the active source isn't known. bugzid: 671
+
+ -- Pulse-Eight Packaging <packaging@pulse-eight.com> Mon, 16 Apr 2012 18:03:00 +0100
+
+libcec (1.5-4) unstable; urgency=low
+
+ * changed/added:
+ * OS-X installation requirements and pointer
+ * full v2 firmware support:
+ * ping the adapter every 15 seconds. bugzid: 541
+ * added v2 msgcodes. bugzid: 543
+ * implemented the write methods for the v2 configuration. bugzid: 543
+ * included the logical addresses in the persisted configuration for v2.
+ bugzid: 543
+ * persist the configuration before closing the connection. only try to
+ persist the configuration when talking to a v2 firmware. bugzid: 543
+ * added GetSetting() to CUSBCECAdapterCommunication. bugzid: 543
+ * read the persisted settings from the ROM, and update it in
+ libcec_configuration if found. bugzid: 543
+ * cec-client: set bGetSettingsFromROM to 1 in cec-client. bugzid: 543
+ * cec-client: only read persisted EEPROM settings when -r or --rom is
+ provided as cmdline arg. bugzid: 543
+ * call SetControlledMode(false) as last command when closing the
+ connection in v2. bugzid: 542
+ * initial FreeBSD support: simply try to use ttyU*
+
+ * fixed:
+ * set controlled mode and retry to send the previous command if it failed
+ with MSGCODE_COMMAND_REJECTED
+ * m_iLineTimeout was never initialised and used. fixes MSGCODE_REJECTED
+ when transmitting a message and incorrect line timeouts being used
+ * mac configure compile bugzid: 157
+ * cec-config-gui: fixed application exit when the user clicked 'no' when
+ asked to reconnect. bugzid: 556
+ * only wait for multiple 'command accepted' response when sending a
+ transmit command, and only to 1 in other cases. bugzid: 543
+ * set the correct logical address mask before switching to autonomous mode.
+ bugzid: 543
+ * re-added SetLineTimeout(). bugzid: 543
+ * CUSBCECAdapterCommunication::SetControlledMode checked for the wrong sent
+ state
+ * os-x: don't add 0.5 before dividing in GetTimeMs()
+ * os-x: struct timespec now values weren't set correctly
+
+ -- Pulse-Eight Packaging <packaging@pulse-eight.com> Fri, 16 Mar 2012 10:12:00 +0100
+