-Key | Value(s) | Default Value | Value type | Description
---- | -------| --------------| ---------- | ------------
-supervisionURLs | | [] | string[] | array of connection URIs to OCPP-J servers
-distributeStationsToTenantsEqually | true/false | true | boolean | distribute charging stations uniformly to the OCPP-J servers
-statisticsDisplayInterval | | 60 | integer | seconds between charging stations statistics output in the logs
-workerProcess | workerSet/staticPool/dynamicPool | workerSet | string | worker threads process type
-workerStartDelay | | 500 | integer | milliseconds to wait at charging station worker threads startup
-workerPoolMinSize | | 4 | integer | worker threads pool minimum number of threads
-workerPoolMaxSize | | 16 | integer | worker threads pool maximum number of threads
-workerPoolStrategy | ROUND_ROBIN/LESS_RECENTLY_USED/... | [poolifier](https://github.com/pioardi/poolifier) default: ROUND_ROBBIN | string | worker threads pool [poolifier](https://github.com/pioardi/poolifier) worker choice strategy
-chargingStationsPerWorker | | 1 | integer | number of charging stations per worker threads for the `workerSet` process type
-logConsole | true/false | false | boolean | output logs on the console
-logFormat | | simple | string | winston log format
-logRotate | true/false | true | boolean | enable daily log files rotation
-logMaxFiles | | 7 | integer | maximum number of log files to keep
-logLevel | emerg/alert/crit/error/warning/notice/info/debug | info | string | winston logging level
-logFile | | combined.log | string | log file relative path
-logErrorFile | | error.log | string | error log file relative path
-stationTemplateURLs | | {}[] | { file: string; numberOfStations: number; }[] | array of charging template file URIs
-
-### Charging station template
-
-Key | Value(s) | Default Value | Value type | Description
---- | -------| --------------| ---------- | ------------
-supervisionURL | | '' | string | connection URI to OCPP-J server
-ocppVersion | 1.6 | 1.6 | string | OCPP version
-ocppProtocol | json | json | string | OCPP protocol
-authorizationFile | | '' | string | RFID tags list file relative to src/assets path
-baseName | | '' | string | base name to build charging stations name
-nameSuffix | | '' | string | name suffix to build charging stations name
-fixedName | true/false | false | boolean | use the baseName as the charging stations unique name
-chargePointModel | | '' | string | charging stations model
-chargePointVendor | | '' | string | charging stations vendor
-chargeBoxSerialNumberPrefix | | '' | string | charging stations serial number prefix
-firmwareVersion | | '' | string | charging stations firmware version
-power | | | integer\|integer[] | charging stations maximum power value(s)
-powerSharedByConnectors | true/false | false | boolean | charging stations power shared by its connectors
-powerUnit | W/kW | W | string | charging stations power unit
-currentOutType | AC/DC | AC | string | charging stations current out type
-numberOfPhases | 0/1/3 | AC:3/DC:0 | integer | charging stations number of phase(s)
-numberOfConnectors | | | integer\|integer[] | charging stations number of connector(s)
-useConnectorId0 | true/false | true | boolean | use connector id 0 definition from the template
-randomConnectors | true/false | false | boolean | randomize runtime connector id affectation from the connector id definition in template
-resetTime | | 60 | integer | seconds to wait before the charging stations come back at reset
-connectionTimeout | | 30 | integer | connection timeout to the OCPP-J server
-autoReconnectMaxRetries | | -1 (unlimited) | integer | connection retries to the OCPP-J server
-reconnectExponentialDelay | true/false | false | boolean | connection delay retry to the OCPP-J server
-registrationMaxRetries | | -1 (unlimited) | integer | charging stations boot notification retries
-enableStatistics | true/false | true | boolean | enable charging stations statistics
-voltageOut | | AC:230/DC:400 | integer | charging stations voltage out
-Configuration | | | ChargingStationConfiguration | charging stations OCPP configuration parameters
-AutomaticTransactionGenerator | | | AutomaticTransactionGenerator | charging stations ATG configuration
-Connectors | | | Connectors | charging stations connectors configuration
+| Key | Value(s) | Default Value | Value type | Description |
+| -------------------------- | ------------------------------------------------ | -------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------- | ----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------- | ------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------- |
+| supervisionUrls | | [] | string \| string[] | string or array of global connection URIs to OCPP-J servers |
+| supervisionUrlDistribution | round-robin/random/sequential | round-robin | boolean | supervision urls distribution policy to simulated charging stations |
+| logStatisticsInterval | | 60 | integer | seconds between charging stations statistics output in the logs |
+| logConsole | true/false | false | boolean | output logs on the console |
+| logFormat | | simple | string | winston log format |
+| logRotate | true/false | true | boolean | enable daily log files rotation |
+| logMaxFiles | | 7 | integer | maximum number of log files to keep |
+| logLevel | emerg/alert/crit/error/warning/notice/info/debug | info | string | winston logging level |
+| logFile | | combined.log | string | log file relative path |
+| logErrorFile | | error.log | string | error log file relative path |
+| worker | | {<br />"processType": "workerSet",<br />"startDelay": 500,<br />"elementStartDelay": 0,<br />"elementsPerWorker": 1,<br />"poolMinSize": 4,<br />"poolMaxSize": 16,<br />"poolStrategy": "ROUND_ROBBIN"<br />} | {<br />processType: WorkerProcessType;<br />startDelay: number;<br />elementStartDelay: number;<br />elementsPerWorker: number;<br />poolMinSize: number;<br />poolMaxSize: number;<br />poolStrategy: WorkerChoiceStrategy;<br />} | Worker configuration section:<br />- processType: worker threads process type (workerSet/staticPool/dynamicPool)<br />- startDelay: milliseconds to wait at worker threads startup (only for workerSet threads process type)<br />- elementStartDelay: milliseconds to wait at charging station startup<br />- elementsPerWorker: number of charging stations per worker threads for the `workerSet` process type<br />- poolMinSize: worker threads pool minimum number of threads</br >- poolMaxSize: worker threads pool maximum number of threads<br />- poolStrategy: worker threads pool [poolifier](https://github.com/poolifier/poolifier) worker choice strategy |
+| uiServer | | {<br />"enabled": true,<br />"options": {<br />"host: "localhost",<br />"port": 8080<br />}<br />} | {<br />enabled: boolean;<br />options: ServerOptions;<br />} | UI WebSocket server configuration section |
+| performanceStorage | | {<br />"enabled": false,<br />"type": "jsonfile",<br />"file:///performanceRecords.json"<br />} | {<br />enabled: boolean;<br />type: string;<br />URI: string;<br />}<br />where type can be 'jsonfile' or 'mongodb' | performance storage configuration section |
+| stationTemplateUrls | | {}[] | {<br />file: string;<br />numberOfStations: number;<br />}[] | array of charging station configuration templates URIs configuration section (charging station configuration template file name and number of stations) |
+
+#### Worker process model:
+
+- **workerSet**:
+ Worker set executing each a static number (chargingStationsPerWorker) of simulated charging stations from the total
+
+- **staticPool**:
+ Statically sized worker pool executing a static total number of simulated charging stations
+
+- **dynamicPool**:
+ Dynamically sized worker pool executing a static total number of simulated charging stations
+
+### Charging station configuration template
+
+**src/assets/station-templates/\<name\>.json**:
+
+| Key | Value(s) | Default Value | Value type | Description |
+| ---------------------------------- | ---------- | ----------------------------------------------------------------- | ---------------------------------------------------------------------------------------------------------------------------------- | ----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------- |
+| supervisionUrls | | '' | string \| string[] | string or array of connection URIs to OCPP-J servers |
+| supervisionUser | | '' | string | basic HTTP authentication user to OCPP-J server |
+| supervisionPassword | | '' | string | basic HTTP authentication password to OCPP-J server |
+| supervisionUrlOcppConfiguration | true/false | false | boolean | allow supervision URL configuration via a vendor OCPP parameter key |
+| supervisionUrlOcppKey | | 'ConnectionUrl' | string | the vendor string that will be used as a vendor OCPP parameter key to set the supervision URL |
+| ocppVersion | 1.6 | 1.6 | string | OCPP version |
+| ocppProtocol | json | json | string | OCPP protocol |
+| ocppStrictCompliance | true/false | false | boolean | strict adherence to the OCPP version and protocol specifications |
+| ocppPersistentConfiguration | true/false | true | boolean | enable persistent OCPP parameters storage by charging stations 'hashId'. The persistency is ensured by the charging stations configuration files in dist/assets/configurations |
+| stationInfoPersistentConfiguration | true/false | true | boolean | enable persistent station information and specifications storage by charging stations 'hashId'. The persistency is ensured by the charging stations configuration files in dist/assets/configurations |
+| wsOptions | | {} | ClientOptions & ClientRequestArgs | [ws](https://github.com/websockets/ws) and node.js [http](https://nodejs.org/api/http.html) clients options intersection |
+| authorizationFile | | '' | string | RFID tags list file relative to src/assets path |
+| baseName | | '' | string | base name to build charging stations id |
+| nameSuffix | | '' | string | name suffix to build charging stations id |
+| fixedName | true/false | false | boolean | use the baseName as the charging stations unique name |
+| chargePointModel | | '' | string | charging stations model |
+| chargePointVendor | | '' | string | charging stations vendor |
+| chargePointSerialNumberPrefix | | '' | string | charge point serial number prefix |
+| chargeBoxSerialNumberPrefix | | '' | string | charge box serial number prefix (deprecated in OCPP 1.6) |
+| firmwareVersion | | '' | string | charging stations firmware version |
+| power | | | float \| float[] | charging stations maximum power value(s) |
+| powerSharedByConnectors | true/false | false | boolean | charging stations power shared by its connectors |
+| powerUnit | W/kW | W | string | charging stations power unit |
+| currentOutType | AC/DC | AC | string | charging stations current out type |
+| voltageOut | | AC:230/DC:400 | integer | charging stations voltage out |
+| numberOfPhases | 0/1/3 | AC:3/DC:0 | integer | charging stations number of phase(s) |
+| numberOfConnectors | | | integer \| integer[] | charging stations number of connector(s) |
+| useConnectorId0 | true/false | true | boolean | use connector id 0 definition from the charging station configuration template |
+| randomConnectors | true/false | false | boolean | randomize runtime connector id affectation from the connector id definition in charging station configuration template |
+| resetTime | | 60 | integer | seconds to wait before the charging stations come back at reset |
+| autoRegister | true/false | false | boolean | set charging stations as registered at boot notification for testing purpose |
+| autoReconnectMaxRetries | | -1 (unlimited) | integer | connection retries to the OCPP-J server |
+| reconnectExponentialDelay | true/false | false | boolean | connection delay retry to the OCPP-J server |
+| registrationMaxRetries | | -1 (unlimited) | integer | charging stations boot notification retries |
+| amperageLimitationOcppKey | | undefined | string | charging stations OCPP parameter key used to set the amperage limit, per phase for each connector on AC and global for DC |
+| amperageLimitationUnit | A/cA/dA/mA | A | string | charging stations amperage limit unit |
+| enableStatistics | true/false | true | boolean | enable charging stations statistics |
+| mayAuthorizeAtRemoteStart | true/false | true | boolean | always send authorize at remote start transaction when AuthorizeRemoteTxRequests is enabled |
+| beginEndMeterValues | true/false | false | boolean | enable Transaction.{Begin,End} MeterValues |
+| outOfOrderEndMeterValues | true/false | false | boolean | send Transaction.End MeterValues out of order. Need to relax OCPP specifications strict compliance ('ocppStrictCompliance' parameter) |
+| meteringPerTransaction | true/false | true | boolean | enable metering history on a per transaction basis |
+| transactionDataMeterValues | true/false | false | boolean | enable transaction data MeterValues at stop transaction |
+| mainVoltageMeterValues | true/false | true | boolean | include charging stations main voltage MeterValues on three phased charging stations |
+| phaseLineToLineVoltageMeterValues | true/false | true | boolean | include charging stations line to line voltage MeterValues on three phased charging stations |
+| customValueLimitationMeterValues | true/false | true | boolean | enable limitation on custom fluctuated value in MeterValues |
+| commandsSupport | | {<br />"incomingCommands": {},<br />"outgoingCommands": {}<br />} | {<br /> incomingCommands: Record<IncomingRequestCommand, boolean>;<br />outgoingCommands?: Record<RequestCommand, boolean>;<br />} | Configuration section for OCPP commands support. Empty section or subsections means all implemented commands are supported |
+| Configuration | | | ChargingStationConfiguration | charging stations OCPP parameters configuration section |
+| AutomaticTransactionGenerator | | | AutomaticTransactionGenerator | charging stations ATG configuration section |
+| Connectors | | | Connectors | charging stations connectors configuration section |