+libcec (1.8.1-1) unstable; urgency=low
+
+ * changed/added:
+ * added cec-client -i / cec-client --info that calls GetLibInfo()
+ * header cleanups
+ * added CAdapterFactory, to create IAdapterCommunication instances
+ * added --debug to configure, to include -ggdb
+
+ * interface changes:
+ * added GetLibInfo()/cec_get_lib_info(), that shows how libCEC was compiled
+ and with which features included.
+ * added ToString(cec_user_control_code_key) to the interface
+
+ * fixed:
+ * disallow sending CEC_OPCODE_SET_STREAM_PATH - not allowed by the CEC spec
+ * persist the configuration in the eeprom after initialising the client.
+ fixes wrong/old settings being used in autonomous mode, which broke the
+ wake on cec funtion
+ * persist the new configuration when the hdmi port setting changed
+ * cleaned locks around callbacks
+ * LibCecSharp: set the primary LA in CecLogicalAddresses
+
+ -- Pulse-Eight Packaging <packaging@pulse-eight.com> Thu, 12 Jul 2012 16:48:00 +0100
+
libcec (1.7.2-1) unstable; urgency=low
* changed/added:
* panasonic: added a vendor command for panasonic that will enable routing
of some more buttons on the remote (guide, text, ...)
* standby command won't be forwarded more than once every 10 seconds
+ * added vendor ids for Akai, AOC, Benq, Daewoo, Grundig, Medion, Sharp and
+ Vizio
* cec-client: don't display debug output by default in 'cec-client -l'
* interface changes:
device lets us know it went into standby mode. fixes possibly failed
active source switches after it succeeded once
* panasonic: fixed delayed source switch for panasonic
+ * panasonic: mark the tv as powered up once it sends the audiomode request
* set the physical address of each device controlled by a CCECClient if
it's valid
* Windows could get stuck in a loop in case there an error occured while
reading registry entries
+ * ABI fixes (binary compat with v1.2 for Windows and v1.5.2 for others)
+ * replace the handler directly after getting the vendor id of a device when
+ registering a client
+ * copy the class member values of the old handler when creating a new
+ command handler, or a delayed activate source will get lost when the
+ handler is switched
* cec-client: wrong client version
* Makefile cleanups. don't link cec-client and cec-config against libudev
and liblockdev
* LibCecSharp: update the local configuration after connecting
* LibCecSharp: better handling of callbacks
- -- Pulse-Eight Packaging <packaging@pulse-eight.com> Mon, 25 Jun 2012 13:02:00 +0100
+ -- Pulse-Eight Packaging <packaging@pulse-eight.com> Wed, 27 Jun 2012 02:06:00 +0100