+libcec (1.1-3) unstable; urgency=low
+
+ * fixed return value in CCECProcessor::SetStreamPath(), which prevented
+ active source and menu state from being sent
+
+ -- Pulse-Eight Packaging <packaging@pulse-eight.com> Fri, 11 Nov 2011 23:36:00 +0100
+
+libcec (1.1-2) unstable; urgency=low
+
+ * forgot to update the headers to v1.1
+
+ -- Pulse-Eight Packaging <packaging@pulse-eight.com> Fri, 11 Nov 2011 18:56:00 +0100
+
+libcec (1.1-1) unstable; urgency=low
+
+ * interface changes:
+ * added logical address autodetection and let libcec handle multiple types
+ simultaniously. for logical address autodetection, you have to use
+ CECInit()/cec_init_typed() instead of CECCreate()/cec_init()
+ * added SetActiveSource()/cec_set_active_source() to the interface.
+ deprecated SetActiveView()/cec_set_active_view()
+ * added SetMenuState()
+ * added PollDevice()/cec_poll_device()
+ * removed duplicate method SetActiveSource() / SetActiveView()
+ * added SetDeckControlMode() and SetDeckInfo()
+ * fixed:
+ * added vendor detection for panasonic and broadcast active view and set
+ menu state when a panasonic device sets the stream path. thanks for the
+ pointer cptcoconut.
+ * added vendor code for pioneer
+ * osd string is 13 chars max. don't send more
+ * send the correct cec version for each device
+ * switch to panasonic specific cec implementation if a panasonic device was
+ detected
+ * send the correct device type in TransmitPhysicalAddress()
+ * send a reply from the correct device when the stream path is requested
+ * opcode 0x80 means the stream path changed, not the physical address
+ * don't poll for a vendor ID in monitoring mode
+ * fixed parameter parsing in SetVendorId()
+ * buffer up commands that are received while waiting for an ack. only send
+ 'active source' message for the actual active source
+ * win32: prepend the com port path with '\\.\', so com ports > 9 can be
+ accessed. thanks smolesen
+ * audio systems cannot be an active source, so don't transmit active
+ source message from this device
+ * only send 'active source' when powered on
+ * only set the osd name for the primary device. use default values for
+ others
+ * increase physical address with 0x100 per device
+ * win32: removed unneeded afxres.h include in the resource files, which
+ is not present when using studio express. thanks Ghuron
+ * fixed C headers
+ * mark the active source as active and other devices as inactive
+ * set the power status to 'on' when receiving CEC_USER_CONTROL_CODE_POWER
+ * transmit the menu state as (active) when the stream path is set
+ * changed:
+ * changed copyright of boblight files with permission of the original
+ author
+ * partial handling of audio related opcodes
+ * more consistent log messages
+ * set a device type and name for each CCECBusDevice
+ * keep a power and menu state per device
+ * renamed all Broadcast...() and Report...() methods to Transmit...()
+ * renamed SetOSDString() to TransmitOSDString()
+ * changed debug level of 'did not receive ack' from error to debug
+ * only set the power status to 'on' for the primary device
+ * moved method decriptions from cecc.h to cec.h
+ * only send a power on command when a device isn't on already and set
+ the power state to CEC_POWER_STATUS_IN_TRANSITION_STANDBY_TO_ON while
+ powering on
+ * handle CEC_OPCODE_STANDBY
+ * handle CEC_OPCODE_ACTIVE_SOURCE
+ * always start in standby mode and let the tv (or other device) send the
+ power on command
+ * renamed the last few enums
+ * handle deck related opcodes.
+ * added TransmitVendorId(), but only transmit the id if it's not set to 'unknown'
+
+ -- Pulse-Eight Packaging <packaging@pulse-eight.com> Fri, 11 Nov 2011 17:42:00 +0100
+
+libcec (1.0-1) unstable; urgency=low
+
+ * interface changes:
+ * set lib interface version back to 1.0 and rename GetLibVersion() to
+ GetLibVersionMajor() and GetMinVersion() to GetMinLibVersion()
+ * added GetLibVersionMinor()/cec_get_lib_version_minor() and set the minor
+ version number to 1
+ * fixed:
+ * samsung's vendor specific remote keypresses don't send key releases. added
+ call to AddKey() directly after the keypress
+ * always reset the button press time in CLibCEC::AddKey()
+ * always wait for a signal in CCECProcessor::Transmit()
+ * changed:
+ * drop shared_ptr and use a normal pointer. removed boost dependency
+
+ -- Pulse-Eight Packaging <packaging@pulse-eight.com> Fri, 04 Nov 2011 00:14:00 +0100
+
+libcec (0.8-2) unstable; urgency=low
+
+ * added 'libboost-dev' to build deps
+
+ -- Pulse-Eight Packaging <packaging@pulse-eight.com> Tue, 01 Nov 2011 23:31:00 +0100
+
+libcec (0.8-1) unstable; urgency=low
+
+ * interface changes:
+ * added GetDevicePowerStatus()/cec_get_device_power_status()
+ * added GetDeviceVendorId()/cec_get_device_vendor_id()
+ * added GetDeviceMenuLanguage()/cec_get_device_menu_language()
+ * added GetDeviceCecVersion()/cec_get_device_cec_version()
+ * added SwitchMonitoring()/cec_switch_monitoring() to the interface. when
+ monitoring is enabled, the device will only log the data it received,
+ but will not respond to any message
+ * removed timeout parameter in Transmit() and included the ack timeout in
+ the cec_command struct
+ * made the vendor id -> vendor name translation available
+ * made CEC_LOG levels powers of 2
+ * introduced CEC_LOG_TRAFFIC log level
+ * fixed:
+ * set the correct ackmask on startup
+ * wait for ack while keeping a lock
+ * wait for the processor thread to start before continueing on startup
+ * wait for messages to be transmitted before continueing in
+ CCECProcessor::Transmit()
+ * only set the logical address once when it has changed
+ * correct source for broadcast messages
+ * win32: create Release type installer
+ * changed:
+ * make all reads and write in CAdapterCommunication go through buffers.
+ * poll for a vendor ID of connected devices and switch to a non-standard
+ CEC implementation if needed.
+ * added vendor detection of Samsung and LG devices
+ * handle samsung remote command 'return'
+ * cec-client:
+ * added -la and --logical-address to the command line params
+ * added -d and --log-level params to cec-client
+ * added -sf and --short-log-file, which only log the actual messages, not
+ the level and timestamp
+ * added -f and --log-file parameters to cec-client
+ * added option to change the log level to cec-client
+
+ -- Pulse-Eight Packaging <packaging@pulse-eight.com> Tue, 01 Nov 2011 22:58:00 +0100
+
+libcec (0.7-1) unstable; urgency=low
+
+ * send a keypress with 0 duration when a key is pressed and with a duration
+ set when it's released
+ * added SetOSDString() to the interface (not supported by all tvs)
+ * fixed: 'routing change' is a broadcast message. log routing changes, but
+ don't send a 'set active view' message, so the active input won't be
+ changed
+ * log keypresses in the debug log
+ * added 'pa' command to cec-client, to change the physical address
+ * added SetPhysicalAddress()/cec_set_physical_address() to the interface, so
+ the HDMI port number to use can be changed
+ * fixed: put the message processing code from WaitForAck() in ParseMessage().
+ fixes missing incoming message logging of non-data messages when not
+ waiting for an ACK
+ * added 'txn' command to cec-client. same as 'tx', but doesn't wait for ACK
+ before returning
+ * fixed: set initiator and destination first in cec_command::push_back().
+ fixes 'tx' command in cec-client
+ * fixed: keep trying to connect while iTimeout isn't reached (default 10
+ seconds). fixes exit with a 'permission denied' error when the device isn't
+ ready yet. remove CEC_SETTLE_DOWN_TIME
+ * fixed: don't call SetActiveView() when reporting the power status. fixes
+ loop which causes some TVs to report failed connections
+ * fixed: eom was not being parsed when receiving MSGCODE_FRAME_DATA. fixed.
+ * fixed: add the device type as parameter when sending the physical address.
+ thanks bobo1on1
+ * fixed: typo in libcec.pc.in
+ * added optional strLib parameter to LoadLibCec(), so the location of the
+ shared library can be specified
+ * only link cec-client against ld. use AC_SEARCH_LIBS instead of AC_CHECK_LIB
+ * use int instead of bool on the public C interface and remove stdbool.h include
+ * renamed: CECExports.h => cec.h, CECExportsC.h => cecc.h, CECLoader.h =>
+ cecloader.h, CECTypes.h => cectypes.h
+ * updated debian package. split up libcec and libcec-dev
+ * fixed: changed to use dlopen instead of static linkage. shuffled headers a
+ bit. bumped interface to version 7
+ * removed 'rt' from libraries. it's not needed (anymore)
+ * fixed: reset the active view after a routing change. issue #1
+ * fixed: changed attached license to be GPLv2 instead of GPLv3 this was an
+ error as libCEC is licensed GPLv2 not GPLv3 thanks @garbear
+ * added contributors link
+
+ -- Pulse-Eight Packaging <packaging@pulse-eight.com> Fri, 14 Oct 2011 17:34:00 +0200
+
+libcec (0.6-1) unstable; urgency=low
+
+ * bumped interface version to 6
+ * fixed packet output (reporting the OSD name correctly now)
+ * refactored packet structs: split up in cec commands and adapter messages
+ * fixed i/o timings
+ * added Darwin support (thanks Davilla!)
+ * fixed WaitForAck()
+ * fixed possible deadlock when starting a new thread
+ * implemented vendor id and device class parsing. full detection will follow
+ * added "on" and "standby" commands to the test client
+ * retransmit packets if needed
+ * fix GetTimeMs() on linux
+ * added timestamp to log messages
+
+ -- Pulse-Eight Packaging <packaging@pulse-eight.com> Sun, 09 Oct 2011 15:15:00 +0200
+
libcec (0.5-1) unstable; urgency=low
* bumped interface version to 5
* fixed some memory leaks
* reset all structs to default values before doing with them
- -- Pulse-Eight Packaging <packaging@pulse-eight.com> Thu, 07 Oct 2011 22:00:00 +0200
+ -- Pulse-Eight Packaging <packaging@pulse-eight.com> Fri, 07 Oct 2011 22:00:00 +0200
libcec (0.4-3) unstable; urgency=low