cec: fixed return value in CCECProcessor::SetStreamPath(), which prevented active...
[deb_libcec.git] / ChangeLog
index b6fd44c6338d1f52e5adb96811eed4a92d70eee9..8af478c706e8b24ecc61d51272a5673edcae0ec1 100644 (file)
--- a/ChangeLog
+++ b/ChangeLog
@@ -1,3 +1,139 @@
+libcec (1.1-2) unstable; urgency=low
+
+  * forgot to update the headers to v1.1
+
+ -- Pulse-Eight Packaging <packaging@pulse-eight.com>  Fri, 11 Nov 2011 18:56:00 +0100
+
+libcec (1.1-1) unstable; urgency=low
+
+  * interface changes:
+    * added logical address autodetection and let libcec handle multiple types
+      simultaniously. for logical address autodetection, you have to use
+      CECInit()/cec_init_typed() instead of CECCreate()/cec_init()
+    * added SetActiveSource()/cec_set_active_source() to the interface.
+      deprecated SetActiveView()/cec_set_active_view()
+    * added SetMenuState()
+    * added PollDevice()/cec_poll_device()
+    * removed duplicate method SetActiveSource() / SetActiveView()
+    * added SetDeckControlMode() and SetDeckInfo()
+  * fixed:
+    * added vendor detection for panasonic and broadcast active view and set
+      menu state when a panasonic device sets the stream path. thanks for the
+      pointer cptcoconut.
+    * added vendor code for pioneer
+    * osd string is 13 chars max. don't send more
+    * send the correct cec version for each device
+    * switch to panasonic specific cec implementation if a panasonic device was
+      detected
+    * send the correct device type in TransmitPhysicalAddress()
+    * send a reply from the correct device when the stream path is requested
+    * opcode 0x80 means the stream path changed, not the physical address
+    * don't poll for a vendor ID in monitoring mode
+    * fixed parameter parsing in SetVendorId()
+    * buffer up commands that are received while waiting for an ack. only send
+      'active source' message for the actual active source
+    * win32: prepend the com port path with '\\.\', so com ports > 9 can be
+      accessed. thanks smolesen
+    * audio systems cannot be an active source, so don't transmit active
+      source message from this device
+    * only send 'active source' when powered on
+    * only set the osd name for the primary device. use default values for
+      others
+    * increase physical address with 0x100 per device
+    * win32: removed unneeded afxres.h include in the resource files, which
+      is not present when using studio express. thanks Ghuron
+    * fixed C headers
+    * mark the active source as active and other devices as inactive
+    * set the power status to 'on' when receiving CEC_USER_CONTROL_CODE_POWER
+    * transmit the menu state as (active) when the stream path is set
+  * changed:
+    * changed copyright of boblight files with permission of the original
+      author
+    * partial handling of audio related opcodes
+    * more consistent log messages
+    * set a device type and name for each CCECBusDevice
+    * keep a power and menu state per device
+    * renamed all Broadcast...() and Report...() methods to Transmit...()
+    * renamed SetOSDString() to TransmitOSDString()
+    * changed debug level of 'did not receive ack' from error to debug
+    * only set the power status to 'on' for the primary device
+    * moved method decriptions from cecc.h to cec.h
+    * only send a power on command when a device isn't on already and set
+      the power state to CEC_POWER_STATUS_IN_TRANSITION_STANDBY_TO_ON while
+      powering on
+    * handle CEC_OPCODE_STANDBY
+    * handle CEC_OPCODE_ACTIVE_SOURCE
+    * always start in standby mode and let the tv (or other device) send the
+      power on command
+    * renamed the last few enums
+    * handle deck related opcodes.
+    * added TransmitVendorId(), but only transmit the id if it's not set to 'unknown'
+
+ -- Pulse-Eight Packaging <packaging@pulse-eight.com>  Fri, 11 Nov 2011 17:42:00 +0100
+
+libcec (1.0-1) unstable; urgency=low
+
+  * interface changes:
+    * set lib interface version back to 1.0 and rename GetLibVersion() to
+      GetLibVersionMajor() and GetMinVersion() to GetMinLibVersion()
+    * added GetLibVersionMinor()/cec_get_lib_version_minor() and set the minor
+      version number to 1
+  * fixed:
+    * samsung's vendor specific remote keypresses don't send key releases. added
+      call to AddKey() directly after the keypress
+    * always reset the button press time in CLibCEC::AddKey()
+    * always wait for a signal in CCECProcessor::Transmit()
+  * changed:
+    * drop shared_ptr and use a normal pointer. removed boost dependency
+
+ -- Pulse-Eight Packaging <packaging@pulse-eight.com>  Fri, 04 Nov 2011 00:14:00 +0100
+
+libcec (0.8-2) unstable; urgency=low
+
+  * added 'libboost-dev' to build deps
+
+ -- Pulse-Eight Packaging <packaging@pulse-eight.com>  Tue, 01 Nov 2011 23:31:00 +0100
+
+libcec (0.8-1) unstable; urgency=low
+
+  * interface changes:
+    * added GetDevicePowerStatus()/cec_get_device_power_status()
+    * added GetDeviceVendorId()/cec_get_device_vendor_id()
+    * added GetDeviceMenuLanguage()/cec_get_device_menu_language()
+    * added GetDeviceCecVersion()/cec_get_device_cec_version()
+    * added SwitchMonitoring()/cec_switch_monitoring() to the interface. when
+      monitoring is enabled, the device will only log the data it received,
+      but will not respond to any message
+    * removed timeout parameter in Transmit() and included the ack timeout in
+       the cec_command struct
+    * made the vendor id -> vendor name translation available
+    * made CEC_LOG levels powers of 2
+    * introduced CEC_LOG_TRAFFIC log level
+  * fixed:
+    * set the correct ackmask on startup
+    * wait for ack while keeping a lock
+    * wait for the processor thread to start before continueing on startup
+    * wait for messages to be transmitted before continueing in
+      CCECProcessor::Transmit()
+    * only set the logical address once when it has changed
+    * correct source for broadcast messages
+    * win32: create Release type installer
+  * changed:
+    * make all reads and write in CAdapterCommunication go through buffers.
+    * poll for a vendor ID of connected devices and switch to a non-standard
+      CEC implementation if needed.
+    * added vendor detection of Samsung and LG devices
+    * handle samsung remote command 'return'
+  * cec-client:
+    * added -la and --logical-address to the command line params
+    * added -d and --log-level params to cec-client
+    * added -sf and --short-log-file, which only log the actual messages, not
+      the level and timestamp
+    * added -f and --log-file parameters to cec-client
+    * added option to change the log level to cec-client
+
+ -- Pulse-Eight Packaging <packaging@pulse-eight.com>  Tue, 01 Nov 2011 22:58:00 +0100
+
 libcec (0.7-1) unstable; urgency=low
 
   * send a keypress with 0 duration when a key is pressed and with a duration