Simple [node.js](https://nodejs.org/) program to simulate a set of charging stations based on the OCPP-J 1.6 protocol.
-## Start
-
-To start the program, run: `npm start`.
-
## Configuration syntax
All configuration files are in the JSON standard format.
supervisionURLs | | [] | string[] | array of connection URIs to OCPP-J servers
distributeStationsToTenantsEqually | true/false | true | boolean | distribute charging stations uniformly to the OCPP-J servers
statisticsDisplayInterval | | 60 | integer | seconds between charging stations statistics output in the logs
-workerProcess | workerSet/staticPool/dynamicPool | workerSet | string | worker threads process type
+workerProcess | workerSet/staticPool/dynamicPool | workerSet | string | worker threads process type
+workerStartDelay | | 500 | integer | milliseconds to wait at charging station worker threads startup
workerPoolMinSize | | 4 | integer | worker threads pool minimum number of threads
workerPoolMaxSize | | 16 | integer | worker threads pool maximum number of threads
+workerPoolStrategy | ROUND_ROBIN/LESS_RECENTLY_USED/... | [poolifier](https://github.com/pioardi/poolifier) default: ROUND_ROBBIN | string | worker threads pool [poolifier](https://github.com/pioardi/poolifier) worker choice strategy
chargingStationsPerWorker | | 1 | integer | number of charging stations per worker threads for the `workerSet` process type
logConsole | true/false | false | boolean | output logs on the console
logFormat | | simple | string | winston log format
logRotate | true/false | true | boolean | enable daily log files rotation
-logMaxFiles | | 7 | integer | maximum number of files to keep
+logMaxFiles | | 7 | integer | maximum number of log files to keep
logLevel | emerg/alert/crit/error/warning/notice/info/debug | info | string | winston logging level
logFile | | combined.log | string | log file relative path
logErrorFile | | error.log | string | error log file relative path
chargePointVendor | | '' | string | charging stations vendor
chargeBoxSerialNumberPrefix | | '' | string | charging stations serial number prefix
firmwareVersion | | '' | string | charging stations firmware version
-power | | | integer\|integer[] | charging stations maximum power value(s)
+power | | | float\|float[] | charging stations maximum power value(s)
powerSharedByConnectors | true/false | false | boolean | charging stations power shared by its connectors
powerUnit | W/kW | W | string | charging stations power unit
+currentOutType | AC/DC | AC | string | charging stations current out type
+voltageOut | | AC:230/DC:400 | integer | charging stations voltage out
+numberOfPhases | 0/1/3 | AC:3/DC:0 | integer | charging stations number of phase(s)
+numberOfConnectors | | | integer\|integer[] | charging stations number of connector(s)
+useConnectorId0 | true/false | true | boolean | use connector id 0 definition from the template
+randomConnectors | true/false | false | boolean | randomize runtime connector id affectation from the connector id definition in template
+resetTime | | 60 | integer | seconds to wait before the charging stations come back at reset
+autoReconnectMaxRetries | | -1 (unlimited) | integer | connection retries to the OCPP-J server
+reconnectExponentialDelay | true/false | false | boolean | connection delay retry to the OCPP-J server
+registrationMaxRetries | | -1 (unlimited) | integer | charging stations boot notification retries
+enableStatistics | true/false | true | boolean | enable charging stations statistics
+mayAuthorizeAtRemoteStart | true/false | true | boolean | always send authorize at remote start transaction when AuthorizeRemoteTxRequests is enabled
+beginEndMeterValues | true/false | false | boolean | enable Transaction.{Begin,End} MeterValues
+outOfOrderEndMeterValues | true/false | false | boolean | send Transaction.End MeterValues out of order
+meteringPerTransaction | true/false | true | boolean | enable metering history on a per transaction basis
+transactionDataMeterValues | true/false | false | boolean | enable transaction data MeterValues at stop transaction
+mainVoltageMeterValues | true/false | true | boolean | include charging station main voltage MeterValues on three phased charging stations
+phaseLineToLineVoltageMeterValues | true/false | true | boolean | include charging station line to line voltage MeterValues on three phased charging stations
+Configuration | | | ChargingStationConfiguration | charging stations OCPP configuration parameters
+AutomaticTransactionGenerator | | | AutomaticTransactionGenerator | charging stations ATG configuration
+Connectors | | | Connectors | charging stations connectors configuration
+
+#### Configuration section
+
+```json
+ "Configuration": {
+ "configurationKey": [
+ ...
+ {
+ "key": "StandardKey",
+ "readonly": false,
+ "value": "StandardValue",
+ "visible": true,
+ "reboot": false
+ },
+ ...
+ {
+ "key": "VendorKey",
+ "readonly": false,
+ "value": "VendorValue",
+ "visible": false,
+ "reboot": true
+ },
+ ...
+ ]
+ }
+```
+
+#### AutomaticTransactionGenerator section
+
+```json
+ "AutomaticTransactionGenerator": {
+ "enable": false,
+ "minDuration": 60,
+ "maxDuration": 80,
+ "minDelayBetweenTwoTransactions": 15,
+ "maxDelayBetweenTwoTransactions": 30,
+ "probabilityOfStart": 1,
+ "stopAfterHours": 0.3,
+ "stopOnConnectionFailure": true,
+ "requireAuthorize": true
+ }
+```
+#### Connectors section
+
+```json
+ "Connectors": {
+ "0": {},
+ "1": {
+ "bootStatus": "Available",
+ "MeterValues": [
+ ...
+ {
+ "unit": "W",
+ "measurand": "Power.Active.Import",
+ "phase": "L1-N",
+ "value": "5000",
+ "fluctuationPercent": "10"
+ },
+ ...
+ {
+ "unit": "A",
+ "measurand": "Current.Import"
+ },
+ ...
+ {
+ "unit": "Wh"
+ },
+ ...
+ ]
+ }
+ },
+```
+
+## Start
+
+To start the program, run: `npm start`.
+
+## Docker
+
+In the [docker](./docker) folder:
+
+```bash
+make
+```
+
+Or without the optional git submodules:
+
+```bash
+make SUBMODULES_INIT=false
+```
+
+## OCPP-J commands supported
+
+### Version 1.6
+
+#### Core Profile
+
+- :white_check_mark: Authorize
+- :white_check_mark: BootNotification
+- :white_check_mark: ChangeAvailability
+- :white_check_mark: ChangeConfiguration
+- :white_check_mark: ClearCache
+- :x: DataTransfer
+- :white_check_mark: GetConfiguration
+- :white_check_mark: Heartbeat
+- :white_check_mark: MeterValues
+- :white_check_mark: RemoteStartTransaction
+- :white_check_mark: RemoteStopTransaction
+- :white_check_mark: Reset
+- :white_check_mark: StartTransaction
+- :white_check_mark: StatusNotification
+- :white_check_mark: StopTransaction
+- :white_check_mark: UnlockConnector
+
+#### Firmware Management Profile
+
+- :x: GetDiagnostics
+- :x: DiagnosticsStatusNotification
+- :x: FirmwareStatusNotification
+- :x: UpdateFirmware
+
+#### Local Auth List Management Profile
+
+- :x: GetLocalListVersion
+- :x: SendLocalList
+
+#### Reservation Profile
+
+- :x: CancelReservation
+- :x: ReserveNow
+
+#### Smart Charging Profile
+
+- :white_check_mark: ClearChargingProfile
+- :white_check_mark: GetCompositeSchedule
+- :white_check_mark: SetChargingProfile
+
+#### Remote Trigger Profile
+
+- :x: TriggerMessage
+
+## OCPP-J standard parameters supported
+
+All kind of OCPP parameters are supported in a charging station template. The list here mention the standard ones also handled automatically in the simulator.
+
+### Version 1.6
+
+#### Core Profile
+
+- :white_check_mark: AuthorizeRemoteTxRequests (type: boolean) (units: -)
+- :x: ClockAlignedDataInterval (type: integer) (units: seconds)
+- :white_check_mark: ConnectionTimeOut (type: integer) (units: seconds)
+- :x: GetConfigurationMaxKeys (type: integer) (units: -)
+- :white_check_mark: HeartbeatInterval (type: integer) (units: seconds)
+- :x: LocalAuthorizeOffline (type: boolean) (units: -)
+- :x: LocalPreAuthorize (type: boolean) (units: -)
+- :x: MeterValuesAlignedData (type: CSL) (units: -)
+- :white_check_mark: MeterValuesSampledData (type: CSL) (units: -)
+- :white_check_mark: MeterValueSampleInterval (type: integer) (units: seconds)
+- :white_check_mark: NumberOfConnectors (type: integer) (units: -)
+- :x: ResetRetries (type: integer) (units: times)
+- :white_check_mark: ConnectorPhaseRotation (type: CSL) (units: -)
+- :x: StopTransactionOnEVSideDisconnect (type: boolean) (units: -)
+- :x: StopTransactionOnInvalidId (type: boolean) (units: -)
+- :x: StopTxnAlignedData (type: CSL) (units: -)
+- :x: StopTxnSampledData (type: CSL) (units: -)
+- :white_check_mark: SupportedFeatureProfiles (type: CSL) (units: -)
+- :x: TransactionMessageAttempts (type: integer) (units: times)
+- :x: TransactionMessageRetryInterval (type: integer) (units: seconds)
+- :x: UnlockConnectorOnEVSideDisconnect (type: boolean) (units: -)
+- :white_check_mark: WebSocketPingInterval (type: integer) (units: seconds)
+
+#### Firmware Management Profile
+
+- *none*
+
+#### Local Auth List Management Profile
+
+- :white_check_mark: LocalAuthListEnabled (type: boolean) (units: -)
+- :x: LocalAuthListMaxLength (type: integer) (units: -)
+- :x: SendLocalListMaxLength (type: integer) (units: -)
+
+#### Reservation Profile
+
+- *none*
+
+#### Smart Charging Profile
+
+- :x: ChargeProfileMaxStackLevel (type: integer) (units: -)
+- :x: ChargingScheduleAllowedChargingRateUnit (type: CSL) (units: -)
+- :x: ChargingScheduleMaxPeriods (type: integer) (units: -)
+- :x: MaxChargingProfilesInstalled (type: integer) (units: -)
+
+#### Remote Trigger Profile
+
+- *none*
## License