Storage: storage records in JSON file as an array to ease import.
[e-mobility-charging-stations-simulator.git] / README.md
index 0813c836a430ebb064cbe7dfb50938d784759546..84d9736b638beefd634632e7b548dc5439bf25e1 100644 (file)
--- a/README.md
+++ b/README.md
@@ -4,10 +4,6 @@
 
 Simple [node.js](https://nodejs.org/) program to simulate a set of charging stations based on the OCPP-J 1.6 protocol.
 
-## Start
-
-To start the program, run: `npm start`.
-
 ## Configuration syntax
 
 All configuration files are in the JSON standard format.  
@@ -26,25 +22,30 @@ Key | Value(s) | Default Value | Value type | Description
 --- | -------| --------------| ---------- | ------------
 supervisionURLs | | [] | string[] |  array of connection URIs to OCPP-J servers
 distributeStationsToTenantsEqually | true/false | true | boolean | distribute charging stations uniformly to the OCPP-J servers
-statisticsDisplayInterval | | 60 | integer | seconds between charging stations statistics output in the logs 
-workerProcess | workerSet/staticPool/dynamicPool | workerSet | string | worker threads process type           
+workerProcess | workerSet/staticPool/dynamicPool | workerSet | string | worker threads process type
+workerStartDelay | | 500 | integer | milliseconds to wait at charging station worker threads startup
 workerPoolMinSize | | 4 | integer | worker threads pool minimum number of threads
 workerPoolMaxSize | | 16 | integer | worker threads pool maximum number of threads
+workerPoolStrategy | ROUND_ROBIN/LESS_RECENTLY_USED/... | [poolifier](https://github.com/poolifier/poolifier) default: ROUND_ROBBIN | string | worker threads pool [poolifier](https://github.com/poolifier/poolifier) worker choice strategy
 chargingStationsPerWorker | | 1 | integer | number of charging stations per worker threads for the `workerSet` process type
+logStatisticsInterval | | 60 | integer | seconds between charging stations statistics output in the logs 
 logConsole | true/false | false | boolean | output logs on the console 
 logFormat | | simple | string | winston log format
 logRotate | true/false | true | boolean | enable daily log files rotation
-logMaxFiles | | 7 | integer | maximum number of files to keep
+logMaxFiles | | 7 | integer | maximum number of log files to keep
 logLevel | emerg/alert/crit/error/warning/notice/info/debug | info | string | winston logging level
 logFile | | combined.log | string | log file relative path
 logErrorFile | | error.log | string | error log file relative path 
-stationTemplateURLs | | {}[] | { file: string; numberOfStations: number; }[] | array of charging template file URIs
+performanceStorage | | { "enabled": false, "type": "jsonfile", "file:///performanceMeasurements.json" } | { enabled: string; type: string; URI: string; } | performance storage configuration section
+stationTemplateURLs | | {}[] | { file: string; numberOfStations: number; }[] | array of charging station templates URIs configuration section (template file name and number of stations)
  
 ### Charging station template
 
 Key | Value(s) | Default Value | Value type | Description 
 --- | -------| --------------| ---------- | ------------
 supervisionURL | | '' | string | connection URI to OCPP-J server
+supervisionUser | | '' | string | basic HTTP authentication user to OCPP-J server
+supervisionPassword | | '' | string | basic HTTP authentication password to OCPP-J server
 ocppVersion | 1.6 | 1.6 | string | OCPP version 
 ocppProtocol | json | json | string | OCPP protocol
 authorizationFile | | '' | string | RFID tags list file relative to src/assets path
@@ -55,12 +56,230 @@ chargePointModel | | '' | string | charging stations model
 chargePointVendor | | '' | string | charging stations vendor
 chargeBoxSerialNumberPrefix | | '' | string | charging stations serial number prefix
 firmwareVersion | | '' | string | charging stations firmware version
-power | | | integer\|integer[] | charging stations maximum power value(s)
+power | | | float\|float[] | charging stations maximum power value(s)
 powerSharedByConnectors | true/false | false | boolean | charging stations power shared by its connectors
 powerUnit | W/kW | W | string | charging stations power unit
+currentOutType | AC/DC | AC | string | charging stations current out type
+voltageOut | | AC:230/DC:400 | integer | charging stations voltage out
+numberOfPhases | 0/1/3 | AC:3/DC:0 | integer | charging stations number of phase(s) 
+numberOfConnectors | | | integer\|integer[] | charging stations number of connector(s)
+useConnectorId0 | true/false | true | boolean | use connector id 0 definition from the template
+randomConnectors | true/false | false | boolean | randomize runtime connector id affectation from the connector id definition in template
+resetTime | | 60 | integer | seconds to wait before the charging stations come back at reset
+autoRegister | true/false | false | boolean | set the charging station as registered at boot notification for testing purpose
+autoReconnectMaxRetries | | -1 (unlimited) | integer | connection retries to the OCPP-J server
+reconnectExponentialDelay | true/false | false | boolean | connection delay retry to the OCPP-J server
+registrationMaxRetries | | -1 (unlimited) | integer | charging stations boot notification retries
+enableStatistics | true/false | true | boolean | enable charging stations statistics
+mayAuthorizeAtRemoteStart | true/false | true | boolean | always send authorize at remote start transaction when AuthorizeRemoteTxRequests is enabled
+beginEndMeterValues | true/false | false | boolean | enable Transaction.{Begin,End} MeterValues
+outOfOrderEndMeterValues | true/false | false | boolean | send Transaction.End MeterValues out of order
+meteringPerTransaction | true/false | true | boolean | enable metering history on a per transaction basis
+transactionDataMeterValues | true/false | false | boolean | enable transaction data MeterValues at stop transaction
+mainVoltageMeterValues | true/false | true | boolean | include charging station main voltage MeterValues on three phased charging stations
+phaseLineToLineVoltageMeterValues | true/false | true | boolean | include charging station line to line voltage MeterValues on three phased charging stations
+Configuration | | | ChargingStationConfiguration | charging stations OCPP parameters configuration section
+AutomaticTransactionGenerator | | | AutomaticTransactionGenerator | charging stations ATG configuration section
+Connectors | | | Connectors | charging stations connectors configuration section
+
+#### Configuration section
+
+```json
+  "Configuration": {
+    "configurationKey": [
+       ...
+       {
+        "key": "StandardKey",
+        "readonly": false,
+        "value": "StandardValue",
+        "visible": true,
+        "reboot": false
+      },
+      ...
+      {
+        "key": "VendorKey",
+        "readonly": false,
+        "value": "VendorValue",
+        "visible": false,
+        "reboot": true
+      },
+      ...
+    ]
+  }
+```
+
+#### AutomaticTransactionGenerator section
+
+```json
+  "AutomaticTransactionGenerator": {
+    "enable": false,
+    "minDuration": 60,
+    "maxDuration": 80,
+    "minDelayBetweenTwoTransactions": 15,
+    "maxDelayBetweenTwoTransactions": 30,
+    "probabilityOfStart": 1,
+    "stopAfterHours": 0.3,
+    "stopOnConnectionFailure": true,
+    "requireAuthorize": true
+  }
+```
+#### Connectors section
+
+```json
+  "Connectors": {
+    "0": {},
+    "1": {
+      "bootStatus": "Available",
+      "MeterValues": [
+        ...
+        {
+          "unit": "W",
+          "measurand": "Power.Active.Import",
+          "phase": "L1-N",
+          "value": "5000",
+          "fluctuationPercent": "10"
+        },
+        ...
+        {
+          "unit": "A",
+          "measurand": "Current.Import"
+        },
+        ...
+        {
+          "unit": "Wh"
+        },
+        ...
+      ]
+    }
+  },
+```
+
+## Start
+
+To start the program, run: `npm start`.
+
+## Docker
+
+In the [docker](./docker) folder:
+
+```bash
+make
+```
+
+Or without the optional git submodules:
+
+```bash
+make SUBMODULES_INIT=false
+```
+
+## OCPP-J commands supported
+
+### Version 1.6
+
+#### Core Profile
+
+- :white_check_mark: Authorize
+- :white_check_mark: BootNotification
+- :white_check_mark: ChangeAvailability
+- :white_check_mark: ChangeConfiguration
+- :white_check_mark: ClearCache
+- :x: DataTransfer
+- :white_check_mark: GetConfiguration
+- :white_check_mark: Heartbeat
+- :white_check_mark: MeterValues
+- :white_check_mark: RemoteStartTransaction
+- :white_check_mark: RemoteStopTransaction
+- :white_check_mark: Reset
+- :white_check_mark: StartTransaction
+- :white_check_mark: StatusNotification
+- :white_check_mark: StopTransaction
+- :white_check_mark: UnlockConnector
+
+#### Firmware Management Profile
+
+- :white_check_mark: GetDiagnostics
+- :x: DiagnosticsStatusNotification
+- :x: FirmwareStatusNotification
+- :x: UpdateFirmware
+
+#### Local Auth List Management Profile
+
+- :x: GetLocalListVersion
+- :x: SendLocalList
+
+#### Reservation Profile
+
+- :x: CancelReservation
+- :x: ReserveNow
+
+#### Smart Charging Profile
+
+- :white_check_mark: ClearChargingProfile
+- :white_check_mark: GetCompositeSchedule
+- :white_check_mark: SetChargingProfile
+
+#### Remote Trigger Profile
+
+- :x: TriggerMessage
+
+## OCPP-J standard parameters supported
+
+All kind of OCPP parameters are supported in a charging station template. The list here mention the standard ones also handled automatically in the simulator. 
+
+### Version 1.6
+
+#### Core Profile
+
+- :white_check_mark: AuthorizeRemoteTxRequests (type: boolean) (units: -)
+- :x: ClockAlignedDataInterval (type: integer) (units: seconds)
+- :white_check_mark: ConnectionTimeOut (type: integer) (units: seconds)
+- :x: GetConfigurationMaxKeys (type: integer) (units: -)
+- :white_check_mark: HeartbeatInterval (type: integer) (units: seconds)
+- :x: LocalAuthorizeOffline (type: boolean) (units: -)
+- :x: LocalPreAuthorize (type: boolean) (units: -)
+- :x: MeterValuesAlignedData (type: CSL) (units: -)
+- :white_check_mark: MeterValuesSampledData (type: CSL) (units: -)
+- :white_check_mark: MeterValueSampleInterval (type: integer) (units: seconds)
+- :white_check_mark: NumberOfConnectors (type: integer) (units: -)
+- :x: ResetRetries (type: integer) (units: times)
+- :white_check_mark: ConnectorPhaseRotation (type: CSL) (units: -)
+- :x: StopTransactionOnEVSideDisconnect (type: boolean) (units: -)
+- :x: StopTransactionOnInvalidId (type: boolean) (units: -)
+- :x: StopTxnAlignedData (type: CSL) (units: -)
+- :x: StopTxnSampledData (type: CSL) (units: -)
+- :white_check_mark: SupportedFeatureProfiles (type: CSL) (units: -)
+- :x: TransactionMessageAttempts (type: integer) (units: times)
+- :x: TransactionMessageRetryInterval (type: integer) (units: seconds)
+- :x: UnlockConnectorOnEVSideDisconnect (type: boolean) (units: -)
+- :white_check_mark: WebSocketPingInterval (type: integer) (units: seconds)
+
+#### Firmware Management Profile
+
+- *none*
+
+#### Local Auth List Management Profile
+
+- :white_check_mark: LocalAuthListEnabled (type: boolean) (units: -)
+- :x: LocalAuthListMaxLength (type: integer) (units: -)
+- :x: SendLocalListMaxLength (type: integer) (units: -)
+
+#### Reservation Profile
+
+- *none*
+
+#### Smart Charging Profile
+
+- :x: ChargeProfileMaxStackLevel (type: integer) (units: -)
+- :x: ChargingScheduleAllowedChargingRateUnit (type: CSL) (units: -)
+- :x: ChargingScheduleMaxPeriods (type: integer) (units: -)
+- :x: MaxChargingProfilesInstalled (type: integer) (units: -)
+
+#### Remote Trigger Profile
+
+- *none*
 
 ## License
 
-This file and all other files in this repository are licensed under the Apache Software License, v.2 and copyrighted under the copyright in [NOTICE](NOTICE) file, except as noted otherwise in the [LICENSE](LICENSE) file.
+This file and all other files in this repository are licensed under the Apache Software License, v.2 and copyrighted under the copyright in [NOTICE](NOTICE) file, except as noted otherwise in the [LICENSE](LICENSE) file or the code source file header.
 
 Please note that Docker images can contain other software which may be licensed under different licenses. This LICENSE and NOTICE files are also included in the Docker image. For any usage of built Docker images please make sure to check the licenses of the artifacts contained in the images.