Add GetDiagnostics command support
[e-mobility-charging-stations-simulator.git] / README.md
index c9f85dd35472c8e31cac339e0abd6fecce251680..bcdefa604e29ee0a38d46877dddbb152a17e48d6 100644 (file)
--- a/README.md
+++ b/README.md
@@ -63,15 +63,18 @@ numberOfConnectors | | | integer\|integer[] | charging stations number of connec
 useConnectorId0 | true/false | true | boolean | use connector id 0 definition from the template
 randomConnectors | true/false | false | boolean | randomize runtime connector id affectation from the connector id definition in template
 resetTime | | 60 | integer | seconds to wait before the charging stations come back at reset
-connectionTimeout | | 30 | integer | connection timeout to the OCPP-J server
+autoRegister | true/false | false | boolean | set the charging station as registered at boot notification for testing purpose
 autoReconnectMaxRetries | | -1 (unlimited) | integer | connection retries to the OCPP-J server
 reconnectExponentialDelay | true/false | false | boolean | connection delay retry to the OCPP-J server
 registrationMaxRetries | | -1 (unlimited) | integer | charging stations boot notification retries
 enableStatistics | true/false | true | boolean | enable charging stations statistics
+mayAuthorizeAtRemoteStart | true/false | true | boolean | always send authorize at remote start transaction when AuthorizeRemoteTxRequests is enabled
 beginEndMeterValues | true/false | false | boolean | enable Transaction.{Begin,End} MeterValues
 outOfOrderEndMeterValues | true/false | false | boolean | send Transaction.End MeterValues out of order
-meteringPerTransaction | true/false | true | boolean | disable metering on a per transaction basis
+meteringPerTransaction | true/false | true | boolean | enable metering history on a per transaction basis
 transactionDataMeterValues | true/false | false | boolean | enable transaction data MeterValues at stop transaction
+mainVoltageMeterValues | true/false | true | boolean | include charging station main voltage MeterValues on three phased charging stations
+phaseLineToLineVoltageMeterValues | true/false | true | boolean | include charging station line to line voltage MeterValues on three phased charging stations
 Configuration | | | ChargingStationConfiguration | charging stations OCPP configuration parameters
 AutomaticTransactionGenerator | | | AutomaticTransactionGenerator | charging stations ATG configuration
 Connectors | | | Connectors | charging stations connectors configuration
@@ -125,6 +128,14 @@ Connectors | | | Connectors | charging stations connectors configuration
     "1": {
       "bootStatus": "Available",
       "MeterValues": [
+        ...
+        {
+          "unit": "W",
+          "measurand": "Power.Active.Import",
+          "phase": "L1-N",
+          "value": "5000",
+          "fluctuationPercent": "10"
+        },
         ...
         {
           "unit": "A",
@@ -210,7 +221,7 @@ make SUBMODULES_INIT=false
 
 ## OCPP-J standard parameters supported
 
-All kind of OCPP parameters is supported in a charging station template. The list here mention the standard ones also handled automatically in the simulator. 
+All kind of OCPP parameters are supported in a charging station template. The list here mention the standard ones also handled automatically in the simulator. 
 
 ### Version 1.6
 
@@ -218,7 +229,7 @@ All kind of OCPP parameters is supported in a charging station template. The lis
 
 - :white_check_mark: AuthorizeRemoteTxRequests (type: boolean) (units: -)
 - :x: ClockAlignedDataInterval (type: integer) (units: seconds)
-- :x: ConnectionTimeOut (type: integer) (units: seconds)
+- :white_check_mark: ConnectionTimeOut (type: integer) (units: seconds)
 - :x: GetConfigurationMaxKeys (type: integer) (units: -)
 - :white_check_mark: HeartbeatInterval (type: integer) (units: seconds)
 - :x: LocalAuthorizeOffline (type: boolean) (units: -)
@@ -233,10 +244,11 @@ All kind of OCPP parameters is supported in a charging station template. The lis
 - :x: StopTransactionOnInvalidId (type: boolean) (units: -)
 - :x: StopTxnAlignedData (type: CSL) (units: -)
 - :x: StopTxnSampledData (type: CSL) (units: -)
-- :x: SupportedFeatureProfiles (type: CSL) (units: -)
+- :white_check_mark: SupportedFeatureProfiles (type: CSL) (units: -)
 - :x: TransactionMessageAttempts (type: integer) (units: times)
 - :x: TransactionMessageRetryInterval (type: integer) (units: seconds)
 - :x: UnlockConnectorOnEVSideDisconnect (type: boolean) (units: -)
+- :white_check_mark: WebSocketPingInterval (type: integer) (units: seconds)
 
 #### Firmware Management Profile
 
@@ -244,7 +256,7 @@ All kind of OCPP parameters is supported in a charging station template. The lis
 
 #### Local Auth List Management Profile
 
-- :x: LocalAuthListEnabled (type: boolean) (units: -)
+- :white_check_mark: LocalAuthListEnabled (type: boolean) (units: -)
 - :x: LocalAuthListMaxLength (type: integer) (units: -)
 - :x: SendLocalListMaxLength (type: integer) (units: -)