+libcec (2.1.3-1) unstable; urgency=low
+
+ * changed / added:
+ * ask users to send an email when receiving an unhandled vendor command
+ * toshiba: map top menu and dvd menu buttons. closes #148
+ * LibCecSharp: sync alert types
+ * LibCecSharp: added CurrentVersion to the version enum
+ * CecSharpClient: use CurrentVersion instead of a hardcoded version
+ * CecTray: power management
+ * CecTray: split up asyncform
+ * CecTray: try/catch xml exceptions when reading the xml config. bugzid:
+ 2082
+ * CecTray: use CurrentVersion instead of a hardcoded version
+ * CecTray: display a warning if we can't poll the TV
+ * CecTray: display alerts from libCEC
+ * CecTray: don't use lazy loading for the main controller, but pass the
+ instance. bugzid: 2082
+ * windows: converted to vs2012
+ * fixed:
+ * toshiba: toshiba handler wasn't initialised, and toshiba uses more than
+ one vendor id
+ * libCEC marked itself as inactive source when the stream path changed to
+ a device with a different physical address. bugzid: 2157
+ * TDA995x: report proper firmware revision (credits: @warped-rudi)
+ * TDA995x: avoid callback when already stopped (credits: @warped-rudi)
+ * windows: fix resource files and backwards compat dll names
+
+ -- Pulse-Eight Packaging <packaging@pulse-eight.com> Sat, 11 May 2013 10:06:00 +0000
+
libcec (2.1.1-1) unstable; urgency=low
* changed / added:
* send an alert when the TV does not respond to polls
* fixed:
* LG didn't switch sources after the TV powered up
- * always poll a device when the status is unknown, and don't try to
- determine whether it needs to be polled by checking the status of other
- devices
- * don't mark a device as inactive when receiving a routing change message,
- only when another device was made acive. fixes the issue that rc
- passthrough doesn't work when a tv sends a quick routing change to
- another port before requesting the active source when coming out of
- standby
+ * always poll a device when the status is unknown, and don't try to
+ determine whether it needs to be polled by checking the status of other
+ devices
+ * don't mark a device as inactive when receiving a routing change message,
+ only when another device was made acive. fixes the issue that rc
+ passthrough doesn't work when a tv sends a quick routing change to
+ another port before requesting the active source when coming out of
+ standby
* LibCecSharp: fixed 14 char long OSD name (wasn't \0 terminated)
- * LibCecSharp: fixed return value of GetActiveDevices(). issue #131
- * cec-tray: fixed index out of range exception in CECSettingNumeric.cs.
- bugzid: 2082
- * cec-tray: ensure that the tray app only initialises once. bugzid: 2082
- * rpi: don't set the physical address to 1.0.0.0 when receiving
- VC_HDMI_UNPLUGGED. it may wake up device when they were just sent to
- standby. issue #142
- * osx: use the correct dylib name in cecloader.h, used by cec-client
+ * LibCecSharp: fixed return value of GetActiveDevices(). issue #131
+ * cec-tray: fixed index out of range exception in CECSettingNumeric.cs.
+ bugzid: 2082
+ * cec-tray: ensure that the tray app only initialises once. bugzid: 2082
+ * rpi: don't set the physical address to 1.0.0.0 when receiving
+ VC_HDMI_UNPLUGGED. it may wake up device when they were just sent to
+ standby. issue #142
+ * osx: use the correct dylib name in cecloader.h, used by cec-client
-- Pulse-Eight Packaging <packaging@pulse-eight.com> Fri, 8 Mar 2013 17:21:00 +0100