cec: updated changelog for new package
[deb_libcec.git] / debian / changelog
index 10c85f199556890f357c851bd110adddc40308c3..8af478c706e8b24ecc61d51272a5673edcae0ec1 100644 (file)
@@ -1,3 +1,233 @@
+libcec (1.1-2) unstable; urgency=low
+
+  * forgot to update the headers to v1.1
+
+ -- Pulse-Eight Packaging <packaging@pulse-eight.com>  Fri, 11 Nov 2011 18:56:00 +0100
+
+libcec (1.1-1) unstable; urgency=low
+
+  * interface changes:
+    * added logical address autodetection and let libcec handle multiple types
+      simultaniously. for logical address autodetection, you have to use
+      CECInit()/cec_init_typed() instead of CECCreate()/cec_init()
+    * added SetActiveSource()/cec_set_active_source() to the interface.
+      deprecated SetActiveView()/cec_set_active_view()
+    * added SetMenuState()
+    * added PollDevice()/cec_poll_device()
+    * removed duplicate method SetActiveSource() / SetActiveView()
+    * added SetDeckControlMode() and SetDeckInfo()
+  * fixed:
+    * added vendor detection for panasonic and broadcast active view and set
+      menu state when a panasonic device sets the stream path. thanks for the
+      pointer cptcoconut.
+    * added vendor code for pioneer
+    * osd string is 13 chars max. don't send more
+    * send the correct cec version for each device
+    * switch to panasonic specific cec implementation if a panasonic device was
+      detected
+    * send the correct device type in TransmitPhysicalAddress()
+    * send a reply from the correct device when the stream path is requested
+    * opcode 0x80 means the stream path changed, not the physical address
+    * don't poll for a vendor ID in monitoring mode
+    * fixed parameter parsing in SetVendorId()
+    * buffer up commands that are received while waiting for an ack. only send
+      'active source' message for the actual active source
+    * win32: prepend the com port path with '\\.\', so com ports > 9 can be
+      accessed. thanks smolesen
+    * audio systems cannot be an active source, so don't transmit active
+      source message from this device
+    * only send 'active source' when powered on
+    * only set the osd name for the primary device. use default values for
+      others
+    * increase physical address with 0x100 per device
+    * win32: removed unneeded afxres.h include in the resource files, which
+      is not present when using studio express. thanks Ghuron
+    * fixed C headers
+    * mark the active source as active and other devices as inactive
+    * set the power status to 'on' when receiving CEC_USER_CONTROL_CODE_POWER
+    * transmit the menu state as (active) when the stream path is set
+  * changed:
+    * changed copyright of boblight files with permission of the original
+      author
+    * partial handling of audio related opcodes
+    * more consistent log messages
+    * set a device type and name for each CCECBusDevice
+    * keep a power and menu state per device
+    * renamed all Broadcast...() and Report...() methods to Transmit...()
+    * renamed SetOSDString() to TransmitOSDString()
+    * changed debug level of 'did not receive ack' from error to debug
+    * only set the power status to 'on' for the primary device
+    * moved method decriptions from cecc.h to cec.h
+    * only send a power on command when a device isn't on already and set
+      the power state to CEC_POWER_STATUS_IN_TRANSITION_STANDBY_TO_ON while
+      powering on
+    * handle CEC_OPCODE_STANDBY
+    * handle CEC_OPCODE_ACTIVE_SOURCE
+    * always start in standby mode and let the tv (or other device) send the
+      power on command
+    * renamed the last few enums
+    * handle deck related opcodes.
+    * added TransmitVendorId(), but only transmit the id if it's not set to 'unknown'
+
+ -- Pulse-Eight Packaging <packaging@pulse-eight.com>  Fri, 11 Nov 2011 17:42:00 +0100
+
+libcec (1.0-1) unstable; urgency=low
+
+  * interface changes:
+    * set lib interface version back to 1.0 and rename GetLibVersion() to
+      GetLibVersionMajor() and GetMinVersion() to GetMinLibVersion()
+    * added GetLibVersionMinor()/cec_get_lib_version_minor() and set the minor
+      version number to 1
+  * fixed:
+    * samsung's vendor specific remote keypresses don't send key releases. added
+      call to AddKey() directly after the keypress
+    * always reset the button press time in CLibCEC::AddKey()
+    * always wait for a signal in CCECProcessor::Transmit()
+  * changed:
+    * drop shared_ptr and use a normal pointer. removed boost dependency
+
+ -- Pulse-Eight Packaging <packaging@pulse-eight.com>  Fri, 04 Nov 2011 00:14:00 +0100
+
+libcec (0.8-2) unstable; urgency=low
+
+  * added 'libboost-dev' to build deps
+
+ -- Pulse-Eight Packaging <packaging@pulse-eight.com>  Tue, 01 Nov 2011 23:31:00 +0100
+
+libcec (0.8-1) unstable; urgency=low
+
+  * interface changes:
+    * added GetDevicePowerStatus()/cec_get_device_power_status()
+    * added GetDeviceVendorId()/cec_get_device_vendor_id()
+    * added GetDeviceMenuLanguage()/cec_get_device_menu_language()
+    * added GetDeviceCecVersion()/cec_get_device_cec_version()
+    * added SwitchMonitoring()/cec_switch_monitoring() to the interface. when
+      monitoring is enabled, the device will only log the data it received,
+      but will not respond to any message
+    * removed timeout parameter in Transmit() and included the ack timeout in
+       the cec_command struct
+    * made the vendor id -> vendor name translation available
+    * made CEC_LOG levels powers of 2
+    * introduced CEC_LOG_TRAFFIC log level
+  * fixed:
+    * set the correct ackmask on startup
+    * wait for ack while keeping a lock
+    * wait for the processor thread to start before continueing on startup
+    * wait for messages to be transmitted before continueing in
+      CCECProcessor::Transmit()
+    * only set the logical address once when it has changed
+    * correct source for broadcast messages
+    * win32: create Release type installer
+  * changed:
+    * make all reads and write in CAdapterCommunication go through buffers.
+    * poll for a vendor ID of connected devices and switch to a non-standard
+      CEC implementation if needed.
+    * added vendor detection of Samsung and LG devices
+    * handle samsung remote command 'return'
+  * cec-client:
+    * added -la and --logical-address to the command line params
+    * added -d and --log-level params to cec-client
+    * added -sf and --short-log-file, which only log the actual messages, not
+      the level and timestamp
+    * added -f and --log-file parameters to cec-client
+    * added option to change the log level to cec-client
+
+ -- Pulse-Eight Packaging <packaging@pulse-eight.com>  Tue, 01 Nov 2011 22:58:00 +0100
+
+libcec (0.7-1) unstable; urgency=low
+
+  * send a keypress with 0 duration when a key is pressed and with a duration
+    set when it's released
+  * added SetOSDString() to the interface (not supported by all tvs)
+  * fixed: 'routing change' is a broadcast message. log routing changes, but
+    don't send a 'set active view' message, so the active input won't be
+    changed
+  * log keypresses in the debug log
+  * added 'pa' command to cec-client, to change the physical address
+  * added SetPhysicalAddress()/cec_set_physical_address() to the interface, so
+    the HDMI port number to use can be changed
+  * fixed: put the message processing code from WaitForAck() in ParseMessage().
+    fixes missing incoming message logging of non-data messages when not
+    waiting for an ACK
+  * added 'txn' command to cec-client. same as 'tx', but doesn't wait for ACK
+    before returning
+  * fixed: set initiator and destination first in cec_command::push_back().
+    fixes 'tx' command in cec-client
+  * fixed: keep trying to connect while iTimeout isn't reached (default 10
+    seconds). fixes exit with a 'permission denied' error when the device isn't
+    ready yet. remove CEC_SETTLE_DOWN_TIME
+  * fixed: don't call SetActiveView() when reporting the power status. fixes
+    loop which causes some TVs to report failed connections
+  * fixed: eom was not being parsed when receiving MSGCODE_FRAME_DATA. fixed.
+  * fixed: add the device type as parameter when sending the physical address.
+    thanks bobo1on1
+  * fixed: typo in libcec.pc.in
+  * added optional strLib parameter to LoadLibCec(), so the location of the
+    shared library can be specified
+  * only link cec-client against ld. use AC_SEARCH_LIBS instead of AC_CHECK_LIB
+  * use int instead of bool on the public C interface and remove stdbool.h include
+  * renamed: CECExports.h => cec.h, CECExportsC.h => cecc.h, CECLoader.h =>
+    cecloader.h, CECTypes.h => cectypes.h
+  * updated debian package. split up libcec and libcec-dev
+  * fixed: changed to use dlopen instead of static linkage. shuffled headers a
+    bit. bumped interface to version 7
+  * removed 'rt' from libraries. it's not needed (anymore)
+  * fixed: reset the active view after a routing change. issue #1
+  * fixed: changed attached license to be GPLv2 instead of GPLv3 this was an
+    error as libCEC is licensed GPLv2 not GPLv3 thanks @garbear
+  * added contributors link
+
+ -- Pulse-Eight Packaging <packaging@pulse-eight.com>  Fri, 14 Oct 2011 17:34:00 +0200
+
+libcec (0.6-1) unstable; urgency=low
+
+  * bumped interface version to 6
+  * fixed packet output (reporting the OSD name correctly now)
+  * refactored packet structs: split up in cec commands and adapter messages
+  * fixed i/o timings
+  * added Darwin support (thanks Davilla!)
+  * fixed WaitForAck()
+  * fixed possible deadlock when starting a new thread
+  * implemented vendor id and device class parsing. full detection will follow
+  * added "on" and "standby" commands to the test client
+  * retransmit packets if needed
+  * fix GetTimeMs() on linux
+  * added timestamp to log messages
+
+ -- Pulse-Eight Packaging <packaging@pulse-eight.com>  Sun, 09 Oct 2011 15:15:00 +0200
+
+libcec (0.5-1) unstable; urgency=low
+
+  * bumped interface version to 5
+  * don't pass std::string and std::vector accross the interface
+  * fixed heap corruption crashes on windows
+  * fixed some memory leaks
+  * reset all structs to default values before doing with them
+
+ -- Pulse-Eight Packaging <packaging@pulse-eight.com>  Fri, 07 Oct 2011 22:00:00 +0200
+
+libcec (0.4-3) unstable; urgency=low
+
+  * fixed reconnect
+  * fixed some threading related bugs
+  * fixed deadlock on exit
+  * fixed wrongly reported physical address
+
+ -- Pulse-Eight Packaging <packaging@pulse-eight.com>  Thu, 06 Oct 2011 00:19:00 +0200
+
+libcec (0.4-2) unstable; urgency=low
+
+  * fixed int parameter sizes and some signed/unsigned warnings
+  * check whether m_port isn't NULL in ReadFromDevice
+  * stop the processor thread and delete the CSerialPort instance on exit
+  * added mutex in CSerialPort
+  * fix segfault on exit
+  * renamed libPlatform -> platform.
+  * stuck everything from libCEC in the CEC namespace to avoid namespace
+    polution
+
+ -- Pulse-Eight Packaging <packaging@pulse-eight.com>  Tue, 04 Oct 2011 23:45:00 +0200
+
 libcec (0.4-1) unstable; urgency=low
 
   * bumped interface version to 4