Fix type comparisons
[e-mobility-charging-stations-simulator.git] / src / assets / station / schneider-imredd.station
index b5cc6bc15cc78d16c2290d72d0f0d19316564bff..a86269053540243182a831344773177a8a218f14 100644 (file)
@@ -9,8 +9,9 @@
     "randomConnectors": false,
     "Configuration": { "configurationKey": [
             { "key": "NumberOfConnectors", "readonly": true, "value": 2},
-            { "key": "param1", "readonly": false, "value": "test"},
-            { "key": "meterValueInterval", "readonly": false, "value": 20},
+            { "key": "MeterValueSampleInterval", "readonly": false, "value": 20},
+            { "key": "SupportedFeatureProfiles", "readonly": true, "value": "Core,LocalAuthListManagement"},
+            { "key": "LocalAuthListEnabled", "readonly": false, "value": false},
             { "key": "AuthorizeRemoteTxRequests", "readonly": false, "value": false}
         ]
     },
@@ -39,4 +40,4 @@
             ]
         }
     }
-}
\ No newline at end of file
+}