feat: set supervision url through the UI protocol
[e-mobility-charging-stations-simulator.git] / src / assets / station-templates / keba.station-template.json
index 5f217ebba98988feabdbc3a2e32e0f8c588f5614..a76741d99f195f12c3f5002f63aa5cf5e741d4a5 100644 (file)
@@ -1,5 +1,5 @@
 {
-  "authorizationFile": "./src/assets/authorization-tags.json",
+  "authorizationFile": "authorization-tags.json",
   "baseName": "CS-KEBA",
   "chargePointModel": "KC-P30-ESS400C2-E0R",
   "chargePointVendor": "Keba AG",
@@ -8,22 +8,24 @@
   "powerUnit": "W",
   "numberOfConnectors": 1,
   "randomConnectors": false,
+  "amperageLimitationOcppKey": "MaxAvailableCurrent",
+  "amperageLimitationUnit": "mA",
   "Configuration": {
     "configurationKey": [
       {
         "key": "MeterValuesSampledData",
         "readonly": false,
-        "value": "Energy.Active.Import.Register"
+        "value": "Energy.Active.Import.Register,Power.Active.Import,Current.Import,Voltage"
       },
       {
         "key": "MeterValueSampleInterval",
         "readonly": false,
-        "value": 30
+        "value": "30"
       },
       {
         "key": "SupportedFeatureProfiles",
         "readonly": true,
-        "value": "Core,LocalAuthListManagement"
+        "value": "Core,FirmwareManagement,LocalAuthListManagement,SmartCharging,RemoteTrigger"
       },
       {
         "key": "LocalAuthListEnabled",
         "key": "AuthorizeRemoteTxRequests",
         "readonly": false,
         "value": "false"
+      },
+      {
+        "key": "WebSocketPingInterval",
+        "readonly": false,
+        "value": "60"
       }
     ]
   },
     "maxDelayBetweenTwoTransactions": 30,
     "probabilityOfStart": 1,
     "stopAfterHours": 0.3,
-    "stopOnConnectionFailure": false
+    "stopOnConnectionFailure": false,
+    "requireAuthorize": true
   },
   "Connectors": {
+    "0": {},
     "1": {
       "MeterValues": [
         {
-          "unit": "Wh",
-          "context": "Sample.Periodic"
+          "unit": "V",
+          "measurand": "Voltage"
+        },
+        {
+          "unit": "W",
+          "measurand": "Power.Active.Import"
+        },
+        {
+          "unit": "A",
+          "measurand": "Current.Import"
+        },
+        {
+          "unit": "Wh"
         }
       ]
     },
     "2": {
       "MeterValues": [
         {
-          "unit": "Wh",
-          "context": "Sample.Periodic"
+          "unit": "V",
+          "measurand": "Voltage"
+        },
+        {
+          "unit": "W",
+          "measurand": "Power.Active.Import"
+        },
+        {
+          "unit": "A",
+          "measurand": "Current.Import"
+        },
+        {
+          "unit": "Wh"
         }
       ]
     }