-import { ChargingProfile, ChargingSchedulePeriod } from '../types/ocpp/ChargingProfile';
-import { ChargingProfileKindType, RecurrencyKindType } from '../types/ocpp/1.6/ChargingProfile';
-import ChargingStationTemplate, {
+import { createHash, randomBytes } from 'node:crypto';
+import type { EventEmitter } from 'node:events';
+import { basename, dirname, join } from 'node:path';
+import { fileURLToPath } from 'node:url';
+
+import chalk from 'chalk';
+import {
+ addDays,
+ addSeconds,
+ addWeeks,
+ differenceInDays,
+ differenceInWeeks,
+ endOfDay,
+ endOfWeek,
+ isAfter,
+ isBefore,
+ startOfDay,
+ startOfWeek,
+} from 'date-fns';
+
+import type { ChargingStation } from './ChargingStation';
+import { BaseError } from '../exception';
+import {
AmpereUnits,
+ AvailabilityType,
+ type BootNotificationRequest,
+ BootReasonEnumType,
+ type ChargingProfile,
+ ChargingProfileKindType,
+ ChargingRateUnitType,
+ type ChargingSchedulePeriod,
+ type ChargingStationInfo,
+ type ChargingStationTemplate,
+ ChargingStationWorkerMessageEvents,
+ ConnectorPhaseRotation,
+ type ConnectorStatus,
+ ConnectorStatusEnum,
CurrentType,
+ type EvseTemplate,
+ type OCPP16BootNotificationRequest,
+ type OCPP20BootNotificationRequest,
+ OCPPVersion,
+ RecurrencyKindType,
Voltage,
-} from '../types/ChargingStationTemplate';
-import { MeterValueMeasurand, MeterValuePhase } from '../types/ocpp/MeterValues';
-
-import BaseError from '../exception/BaseError';
-import { BootNotificationRequest } from '../types/ocpp/Requests';
-import ChargingStation from './ChargingStation';
-import ChargingStationConfiguration from '../types/ChargingStationConfiguration';
-import { ChargingStationConfigurationUtils } from './ChargingStationConfigurationUtils';
-import ChargingStationInfo from '../types/ChargingStationInfo';
-import Configuration from '../utils/Configuration';
-import Constants from '../utils/Constants';
-import { FileType } from '../types/FileType';
-import FileUtils from '../utils/FileUtils';
-import { SampledValueTemplate } from '../types/MeasurandPerPhaseSampledValueTemplates';
-import { StandardParametersKey } from '../types/ocpp/Configuration';
-import Utils from '../utils/Utils';
-import { WebSocketCloseEventStatusString } from '../types/WebSocket';
-import { WorkerProcessType } from '../types/Worker';
-import crypto from 'crypto';
-import fs from 'fs';
-import logger from '../utils/Logger';
-import moment from 'moment';
-import path from 'path';
-
-export class ChargingStationUtils {
- public static getChargingStationId(
- index: number,
- stationTemplate: ChargingStationTemplate
- ): string {
- // In case of multiple instances: add instance index to charging station id
- const instanceIndex = process.env.CF_INSTANCE_INDEX ?? 0;
- const idSuffix = stationTemplate.nameSuffix ?? '';
- const idStr = '000000000' + index.toString();
- return stationTemplate?.fixedName
- ? stationTemplate.baseName
- : stationTemplate.baseName +
- '-' +
- instanceIndex.toString() +
- idStr.substring(idStr.length - 4) +
- idSuffix;
+} from '../types';
+import {
+ ACElectricUtils,
+ Constants,
+ DCElectricUtils,
+ cloneObject,
+ convertToDate,
+ convertToInt,
+ isEmptyObject,
+ isEmptyString,
+ isNotEmptyArray,
+ isNotEmptyString,
+ isNullOrUndefined,
+ isUndefined,
+ logger,
+ secureRandom,
+} from '../utils';
+
+const moduleName = 'ChargingStationUtils';
+
+export const getChargingStationId = (
+ index: number,
+ stationTemplate: ChargingStationTemplate,
+): string => {
+ // In case of multiple instances: add instance index to charging station id
+ const instanceIndex = process.env.CF_INSTANCE_INDEX ?? 0;
+ const idSuffix = stationTemplate?.nameSuffix ?? '';
+ const idStr = `000000000${index.toString()}`;
+ return stationTemplate?.fixedName
+ ? stationTemplate.baseName
+ : `${stationTemplate.baseName}-${instanceIndex.toString()}${idStr.substring(
+ idStr.length - 4,
+ )}${idSuffix}`;
+};
+
+export const countReservableConnectors = (connectors: Map<number, ConnectorStatus>) => {
+ let reservableConnectors = 0;
+ for (const [connectorId, connectorStatus] of connectors) {
+ if (connectorId === 0) {
+ continue;
+ }
+ if (connectorStatus.status === ConnectorStatusEnum.Available) {
+ ++reservableConnectors;
+ }
}
+ return reservableConnectors;
+};
+
+export const getHashId = (index: number, stationTemplate: ChargingStationTemplate): string => {
+ const chargingStationInfo = {
+ chargePointModel: stationTemplate.chargePointModel,
+ chargePointVendor: stationTemplate.chargePointVendor,
+ ...(!isUndefined(stationTemplate.chargeBoxSerialNumberPrefix) && {
+ chargeBoxSerialNumber: stationTemplate.chargeBoxSerialNumberPrefix,
+ }),
+ ...(!isUndefined(stationTemplate.chargePointSerialNumberPrefix) && {
+ chargePointSerialNumber: stationTemplate.chargePointSerialNumberPrefix,
+ }),
+ ...(!isUndefined(stationTemplate.meterSerialNumberPrefix) && {
+ meterSerialNumber: stationTemplate.meterSerialNumberPrefix,
+ }),
+ ...(!isUndefined(stationTemplate.meterType) && {
+ meterType: stationTemplate.meterType,
+ }),
+ };
+ return createHash(Constants.DEFAULT_HASH_ALGORITHM)
+ .update(`${JSON.stringify(chargingStationInfo)}${getChargingStationId(index, stationTemplate)}`)
+ .digest('hex');
+};
- public static getHashId(index: number, stationTemplate: ChargingStationTemplate): string {
- const hashBootNotificationRequest = {
- chargePointModel: stationTemplate.chargePointModel,
- chargePointVendor: stationTemplate.chargePointVendor,
- ...(!Utils.isUndefined(stationTemplate.chargeBoxSerialNumberPrefix) && {
- chargeBoxSerialNumber: stationTemplate.chargeBoxSerialNumberPrefix,
- }),
- ...(!Utils.isUndefined(stationTemplate.chargePointSerialNumberPrefix) && {
- chargePointSerialNumber: stationTemplate.chargePointSerialNumberPrefix,
- }),
- ...(!Utils.isUndefined(stationTemplate.firmwareVersion) && {
- firmwareVersion: stationTemplate.firmwareVersion,
- }),
- ...(!Utils.isUndefined(stationTemplate.iccid) && { iccid: stationTemplate.iccid }),
- ...(!Utils.isUndefined(stationTemplate.imsi) && { imsi: stationTemplate.imsi }),
- ...(!Utils.isUndefined(stationTemplate.meterSerialNumberPrefix) && {
- meterSerialNumber: stationTemplate.meterSerialNumberPrefix,
- }),
- ...(!Utils.isUndefined(stationTemplate.meterType) && {
- meterType: stationTemplate.meterType,
- }),
- };
- return crypto
- .createHash(Constants.DEFAULT_HASH_ALGORITHM)
- .update(
- JSON.stringify(hashBootNotificationRequest) +
- ChargingStationUtils.getChargingStationId(index, stationTemplate)
- )
- .digest('hex');
+export const checkChargingStation = (
+ chargingStation: ChargingStation,
+ logPrefix: string,
+): boolean => {
+ if (chargingStation.started === false && chargingStation.starting === false) {
+ logger.warn(`${logPrefix} charging station is stopped, cannot proceed`);
+ return false;
}
+ return true;
+};
- public static getTemplateMaxNumberOfConnectors(stationTemplate: ChargingStationTemplate): number {
- const templateConnectors = stationTemplate?.Connectors;
- if (!templateConnectors) {
- return -1;
- }
- return Object.keys(templateConnectors).length;
+export const getPhaseRotationValue = (
+ connectorId: number,
+ numberOfPhases: number,
+): string | undefined => {
+ // AC/DC
+ if (connectorId === 0 && numberOfPhases === 0) {
+ return `${connectorId}.${ConnectorPhaseRotation.RST}`;
+ } else if (connectorId > 0 && numberOfPhases === 0) {
+ return `${connectorId}.${ConnectorPhaseRotation.NotApplicable}`;
+ // AC
+ } else if (connectorId > 0 && numberOfPhases === 1) {
+ return `${connectorId}.${ConnectorPhaseRotation.NotApplicable}`;
+ } else if (connectorId > 0 && numberOfPhases === 3) {
+ return `${connectorId}.${ConnectorPhaseRotation.RST}`;
}
+};
- public static checkTemplateMaxConnectors(
- templateMaxConnectors: number,
- templateFile: string,
- logPrefix: string
- ): void {
- if (templateMaxConnectors === 0) {
- logger.warn(
- `${logPrefix} Charging station information from template ${templateFile} with empty connectors configuration`
- );
- } else if (templateMaxConnectors < 0) {
- logger.error(
- `${logPrefix} Charging station information from template ${templateFile} with no connectors configuration defined`
- );
- }
+export const getMaxNumberOfEvses = (evses: Record<string, EvseTemplate>): number => {
+ if (!evses) {
+ return -1;
}
+ return Object.keys(evses).length;
+};
- public static getConfiguredNumberOfConnectors(
- index: number,
- stationTemplate: ChargingStationTemplate
- ): number {
- let configuredMaxConnectors: number;
- if (!Utils.isEmptyArray(stationTemplate.numberOfConnectors)) {
- const numberOfConnectors = stationTemplate.numberOfConnectors as number[];
- // Distribute evenly the number of connectors
- configuredMaxConnectors = numberOfConnectors[(index - 1) % numberOfConnectors.length];
- } else if (!Utils.isUndefined(stationTemplate.numberOfConnectors)) {
- configuredMaxConnectors = stationTemplate.numberOfConnectors as number;
- } else {
- configuredMaxConnectors = stationTemplate?.Connectors[0]
- ? ChargingStationUtils.getTemplateMaxNumberOfConnectors(stationTemplate) - 1
- : ChargingStationUtils.getTemplateMaxNumberOfConnectors(stationTemplate);
- }
- return configuredMaxConnectors;
+const getMaxNumberOfConnectors = (connectors: Record<string, ConnectorStatus>): number => {
+ if (!connectors) {
+ return -1;
}
+ return Object.keys(connectors).length;
+};
- public static checkConfiguredMaxConnectors(
- configuredMaxConnectors: number,
- templateFile: string,
- logPrefix: string
- ): void {
- if (configuredMaxConnectors <= 0) {
- logger.warn(
- `${logPrefix} Charging station information from template ${templateFile} with ${configuredMaxConnectors} connectors`
- );
- }
+export const getBootConnectorStatus = (
+ chargingStation: ChargingStation,
+ connectorId: number,
+ connectorStatus: ConnectorStatus,
+): ConnectorStatusEnum => {
+ let connectorBootStatus: ConnectorStatusEnum;
+ if (
+ !connectorStatus?.status &&
+ (chargingStation.isChargingStationAvailable() === false ||
+ chargingStation.isConnectorAvailable(connectorId) === false)
+ ) {
+ connectorBootStatus = ConnectorStatusEnum.Unavailable;
+ } else if (!connectorStatus?.status && connectorStatus?.bootStatus) {
+ // Set boot status in template at startup
+ connectorBootStatus = connectorStatus?.bootStatus;
+ } else if (connectorStatus?.status) {
+ // Set previous status at startup
+ connectorBootStatus = connectorStatus?.status;
+ } else {
+ // Set default status
+ connectorBootStatus = ConnectorStatusEnum.Available;
}
+ return connectorBootStatus;
+};
- public static createBootNotificationRequest(
- stationInfo: ChargingStationInfo
- ): BootNotificationRequest {
- return {
- chargePointModel: stationInfo.chargePointModel,
- chargePointVendor: stationInfo.chargePointVendor,
- ...(!Utils.isUndefined(stationInfo.chargeBoxSerialNumber) && {
- chargeBoxSerialNumber: stationInfo.chargeBoxSerialNumber,
- }),
- ...(!Utils.isUndefined(stationInfo.chargePointSerialNumber) && {
- chargePointSerialNumber: stationInfo.chargePointSerialNumber,
- }),
- ...(!Utils.isUndefined(stationInfo.firmwareVersion) && {
- firmwareVersion: stationInfo.firmwareVersion,
- }),
- ...(!Utils.isUndefined(stationInfo.iccid) && { iccid: stationInfo.iccid }),
- ...(!Utils.isUndefined(stationInfo.imsi) && { imsi: stationInfo.imsi }),
- ...(!Utils.isUndefined(stationInfo.meterSerialNumber) && {
- meterSerialNumber: stationInfo.meterSerialNumber,
- }),
- ...(!Utils.isUndefined(stationInfo.meterType) && {
- meterType: stationInfo.meterType,
- }),
- };
+export const checkTemplate = (
+ stationTemplate: ChargingStationTemplate,
+ logPrefix: string,
+ templateFile: string,
+): void => {
+ if (isNullOrUndefined(stationTemplate)) {
+ const errorMsg = `Failed to read charging station template file ${templateFile}`;
+ logger.error(`${logPrefix} ${errorMsg}`);
+ throw new BaseError(errorMsg);
}
+ if (isEmptyObject(stationTemplate)) {
+ const errorMsg = `Empty charging station information from template file ${templateFile}`;
+ logger.error(`${logPrefix} ${errorMsg}`);
+ throw new BaseError(errorMsg);
+ }
+ if (isEmptyObject(stationTemplate.AutomaticTransactionGenerator!)) {
+ stationTemplate.AutomaticTransactionGenerator = Constants.DEFAULT_ATG_CONFIGURATION;
+ logger.warn(
+ `${logPrefix} Empty automatic transaction generator configuration from template file ${templateFile}, set to default: %j`,
+ Constants.DEFAULT_ATG_CONFIGURATION,
+ );
+ }
+ if (isNullOrUndefined(stationTemplate.idTagsFile) || isEmptyString(stationTemplate.idTagsFile)) {
+ logger.warn(
+ `${logPrefix} Missing id tags file in template file ${templateFile}. That can lead to issues with the Automatic Transaction Generator`,
+ );
+ }
+};
- public static workerPoolInUse(): boolean {
- return [WorkerProcessType.DYNAMIC_POOL, WorkerProcessType.STATIC_POOL].includes(
- Configuration.getWorkerProcess()
+export const checkConnectorsConfiguration = (
+ stationTemplate: ChargingStationTemplate,
+ logPrefix: string,
+ templateFile: string,
+): {
+ configuredMaxConnectors: number;
+ templateMaxConnectors: number;
+ templateMaxAvailableConnectors: number;
+} => {
+ const configuredMaxConnectors = getConfiguredNumberOfConnectors(stationTemplate);
+ checkConfiguredMaxConnectors(configuredMaxConnectors, logPrefix, templateFile);
+ const templateMaxConnectors = getMaxNumberOfConnectors(stationTemplate.Connectors!);
+ checkTemplateMaxConnectors(templateMaxConnectors, logPrefix, templateFile);
+ const templateMaxAvailableConnectors = stationTemplate.Connectors![0]
+ ? templateMaxConnectors - 1
+ : templateMaxConnectors;
+ if (
+ configuredMaxConnectors > templateMaxAvailableConnectors &&
+ !stationTemplate?.randomConnectors
+ ) {
+ logger.warn(
+ `${logPrefix} Number of connectors exceeds the number of connector configurations in template ${templateFile}, forcing random connector configurations affectation`,
);
+ stationTemplate.randomConnectors = true;
}
+ return { configuredMaxConnectors, templateMaxConnectors, templateMaxAvailableConnectors };
+};
- public static workerDynamicPoolInUse(): boolean {
- return Configuration.getWorkerProcess() === WorkerProcessType.DYNAMIC_POOL;
+export const checkStationInfoConnectorStatus = (
+ connectorId: number,
+ connectorStatus: ConnectorStatus,
+ logPrefix: string,
+ templateFile: string,
+): void => {
+ if (!isNullOrUndefined(connectorStatus?.status)) {
+ logger.warn(
+ `${logPrefix} Charging station information from template ${templateFile} with connector id ${connectorId} status configuration defined, undefine it`,
+ );
+ delete connectorStatus.status;
}
+};
- /**
- * Convert websocket error code to human readable string message
- *
- * @param code websocket error code
- * @returns human readable string message
- */
- public static getWebSocketCloseEventStatusString(code: number): string {
- if (code >= 0 && code <= 999) {
- return '(Unused)';
- } else if (code >= 1016) {
- if (code <= 1999) {
- return '(For WebSocket standard)';
- } else if (code <= 2999) {
- return '(For WebSocket extensions)';
- } else if (code <= 3999) {
- return '(For libraries and frameworks)';
- } else if (code <= 4999) {
- return '(For applications)';
- }
- }
- if (!Utils.isUndefined(WebSocketCloseEventStatusString[code])) {
- return WebSocketCloseEventStatusString[code] as string;
+export const buildConnectorsMap = (
+ connectors: Record<string, ConnectorStatus>,
+ logPrefix: string,
+ templateFile: string,
+): Map<number, ConnectorStatus> => {
+ const connectorsMap = new Map<number, ConnectorStatus>();
+ if (getMaxNumberOfConnectors(connectors) > 0) {
+ for (const connector in connectors) {
+ const connectorStatus = connectors[connector];
+ const connectorId = convertToInt(connector);
+ checkStationInfoConnectorStatus(connectorId, connectorStatus, logPrefix, templateFile);
+ connectorsMap.set(connectorId, cloneObject<ConnectorStatus>(connectorStatus));
}
- return '(Unknown)';
+ } else {
+ logger.warn(
+ `${logPrefix} Charging station information from template ${templateFile} with no connectors, cannot build connectors map`,
+ );
}
+ return connectorsMap;
+};
- public static warnDeprecatedTemplateKey(
- template: ChargingStationTemplate,
- key: string,
- templateFile: string,
- logPrefix: string,
- logMsgToAppend = ''
- ): void {
- if (!Utils.isUndefined(template[key])) {
+export const initializeConnectorsMapStatus = (
+ connectors: Map<number, ConnectorStatus>,
+ logPrefix: string,
+): void => {
+ for (const connectorId of connectors.keys()) {
+ if (connectorId > 0 && connectors.get(connectorId)?.transactionStarted === true) {
logger.warn(
- `${logPrefix} Deprecated template key '${key}' usage in file '${templateFile}'${
- logMsgToAppend && '. ' + logMsgToAppend
- }`
+ `${logPrefix} Connector id ${connectorId} at initialization has a transaction started with id ${connectors.get(
+ connectorId,
+ )?.transactionId}`,
);
}
+ if (connectorId === 0) {
+ connectors.get(connectorId)!.availability = AvailabilityType.Operative;
+ if (isUndefined(connectors.get(connectorId)?.chargingProfiles)) {
+ connectors.get(connectorId)!.chargingProfiles = [];
+ }
+ } else if (
+ connectorId > 0 &&
+ isNullOrUndefined(connectors.get(connectorId)?.transactionStarted)
+ ) {
+ initializeConnectorStatus(connectors.get(connectorId)!);
+ }
}
+};
- public static convertDeprecatedTemplateKey(
- template: ChargingStationTemplate,
- deprecatedKey: string,
- key: string
- ): void {
- if (!Utils.isUndefined(template[deprecatedKey])) {
- template[key] = template[deprecatedKey] as unknown;
- delete template[deprecatedKey];
- }
+export const resetConnectorStatus = (connectorStatus: ConnectorStatus): void => {
+ connectorStatus.idTagLocalAuthorized = false;
+ connectorStatus.idTagAuthorized = false;
+ connectorStatus.transactionRemoteStarted = false;
+ connectorStatus.transactionStarted = false;
+ delete connectorStatus?.localAuthorizeIdTag;
+ delete connectorStatus?.authorizeIdTag;
+ delete connectorStatus?.transactionId;
+ delete connectorStatus?.transactionIdTag;
+ connectorStatus.transactionEnergyActiveImportRegisterValue = 0;
+ delete connectorStatus?.transactionBeginMeterValue;
+};
+
+export const createBootNotificationRequest = (
+ stationInfo: ChargingStationInfo,
+ bootReason: BootReasonEnumType = BootReasonEnumType.PowerUp,
+): BootNotificationRequest => {
+ const ocppVersion = stationInfo.ocppVersion ?? OCPPVersion.VERSION_16;
+ switch (ocppVersion) {
+ case OCPPVersion.VERSION_16:
+ return {
+ chargePointModel: stationInfo.chargePointModel,
+ chargePointVendor: stationInfo.chargePointVendor,
+ ...(!isUndefined(stationInfo.chargeBoxSerialNumber) && {
+ chargeBoxSerialNumber: stationInfo.chargeBoxSerialNumber,
+ }),
+ ...(!isUndefined(stationInfo.chargePointSerialNumber) && {
+ chargePointSerialNumber: stationInfo.chargePointSerialNumber,
+ }),
+ ...(!isUndefined(stationInfo.firmwareVersion) && {
+ firmwareVersion: stationInfo.firmwareVersion,
+ }),
+ ...(!isUndefined(stationInfo.iccid) && { iccid: stationInfo.iccid }),
+ ...(!isUndefined(stationInfo.imsi) && { imsi: stationInfo.imsi }),
+ ...(!isUndefined(stationInfo.meterSerialNumber) && {
+ meterSerialNumber: stationInfo.meterSerialNumber,
+ }),
+ ...(!isUndefined(stationInfo.meterType) && {
+ meterType: stationInfo.meterType,
+ }),
+ } as OCPP16BootNotificationRequest;
+ case OCPPVersion.VERSION_20:
+ case OCPPVersion.VERSION_201:
+ return {
+ reason: bootReason,
+ chargingStation: {
+ model: stationInfo.chargePointModel,
+ vendorName: stationInfo.chargePointVendor,
+ ...(!isUndefined(stationInfo.firmwareVersion) && {
+ firmwareVersion: stationInfo.firmwareVersion,
+ }),
+ ...(!isUndefined(stationInfo.chargeBoxSerialNumber) && {
+ serialNumber: stationInfo.chargeBoxSerialNumber,
+ }),
+ ...((!isUndefined(stationInfo.iccid) || !isUndefined(stationInfo.imsi)) && {
+ modem: {
+ ...(!isUndefined(stationInfo.iccid) && { iccid: stationInfo.iccid }),
+ ...(!isUndefined(stationInfo.imsi) && { imsi: stationInfo.imsi }),
+ },
+ }),
+ },
+ } as OCPP20BootNotificationRequest;
}
+};
- public static stationTemplateToStationInfo(
- stationTemplate: ChargingStationTemplate
- ): ChargingStationInfo {
- stationTemplate = Utils.cloneObject(stationTemplate);
- delete stationTemplate.power;
- delete stationTemplate.powerUnit;
- delete stationTemplate.Configuration;
- delete stationTemplate.AutomaticTransactionGenerator;
- delete stationTemplate.chargeBoxSerialNumberPrefix;
- delete stationTemplate.chargePointSerialNumberPrefix;
- delete stationTemplate.meterSerialNumberPrefix;
- return stationTemplate;
+export const warnTemplateKeysDeprecation = (
+ stationTemplate: ChargingStationTemplate,
+ logPrefix: string,
+ templateFile: string,
+) => {
+ const templateKeys: { deprecatedKey: string; key?: string }[] = [
+ { deprecatedKey: 'supervisionUrl', key: 'supervisionUrls' },
+ { deprecatedKey: 'authorizationFile', key: 'idTagsFile' },
+ { deprecatedKey: 'payloadSchemaValidation', key: 'ocppStrictCompliance' },
+ ];
+ for (const templateKey of templateKeys) {
+ warnDeprecatedTemplateKey(
+ stationTemplate,
+ templateKey.deprecatedKey,
+ logPrefix,
+ templateFile,
+ !isUndefined(templateKey.key) ? `Use '${templateKey.key}' instead` : undefined,
+ );
+ convertDeprecatedTemplateKey(stationTemplate, templateKey.deprecatedKey, templateKey.key);
}
+};
+
+export const stationTemplateToStationInfo = (
+ stationTemplate: ChargingStationTemplate,
+): ChargingStationInfo => {
+ stationTemplate = cloneObject<ChargingStationTemplate>(stationTemplate);
+ delete stationTemplate.power;
+ delete stationTemplate.powerUnit;
+ delete stationTemplate.Connectors;
+ delete stationTemplate.Evses;
+ delete stationTemplate.Configuration;
+ delete stationTemplate.AutomaticTransactionGenerator;
+ delete stationTemplate.chargeBoxSerialNumberPrefix;
+ delete stationTemplate.chargePointSerialNumberPrefix;
+ delete stationTemplate.meterSerialNumberPrefix;
+ return stationTemplate as unknown as ChargingStationInfo;
+};
+
+export const createSerialNumber = (
+ stationTemplate: ChargingStationTemplate,
+ stationInfo: ChargingStationInfo,
+ params: {
+ randomSerialNumberUpperCase?: boolean;
+ randomSerialNumber?: boolean;
+ } = {
+ randomSerialNumberUpperCase: true,
+ randomSerialNumber: true,
+ },
+): void => {
+ params = { ...{ randomSerialNumberUpperCase: true, randomSerialNumber: true }, ...params };
+ const serialNumberSuffix = params?.randomSerialNumber
+ ? getRandomSerialNumberSuffix({
+ upperCase: params.randomSerialNumberUpperCase,
+ })
+ : '';
+ isNotEmptyString(stationTemplate?.chargePointSerialNumberPrefix) &&
+ (stationInfo.chargePointSerialNumber = `${stationTemplate.chargePointSerialNumberPrefix}${serialNumberSuffix}`);
+ isNotEmptyString(stationTemplate?.chargeBoxSerialNumberPrefix) &&
+ (stationInfo.chargeBoxSerialNumber = `${stationTemplate.chargeBoxSerialNumberPrefix}${serialNumberSuffix}`);
+ isNotEmptyString(stationTemplate?.meterSerialNumberPrefix) &&
+ (stationInfo.meterSerialNumber = `${stationTemplate.meterSerialNumberPrefix}${serialNumberSuffix}`);
+};
- public static createStationInfoHash(stationInfo: ChargingStationInfo): void {
- delete stationInfo.infoHash;
- stationInfo.infoHash = crypto
- .createHash(Constants.DEFAULT_HASH_ALGORITHM)
- .update(JSON.stringify(stationInfo))
- .digest('hex');
+export const propagateSerialNumber = (
+ stationTemplate: ChargingStationTemplate,
+ stationInfoSrc: ChargingStationInfo,
+ stationInfoDst: ChargingStationInfo,
+) => {
+ if (!stationInfoSrc || !stationTemplate) {
+ throw new BaseError(
+ 'Missing charging station template or existing configuration to propagate serial number',
+ );
}
+ stationTemplate?.chargePointSerialNumberPrefix && stationInfoSrc?.chargePointSerialNumber
+ ? (stationInfoDst.chargePointSerialNumber = stationInfoSrc.chargePointSerialNumber)
+ : stationInfoDst?.chargePointSerialNumber && delete stationInfoDst.chargePointSerialNumber;
+ stationTemplate?.chargeBoxSerialNumberPrefix && stationInfoSrc?.chargeBoxSerialNumber
+ ? (stationInfoDst.chargeBoxSerialNumber = stationInfoSrc.chargeBoxSerialNumber)
+ : stationInfoDst?.chargeBoxSerialNumber && delete stationInfoDst.chargeBoxSerialNumber;
+ stationTemplate?.meterSerialNumberPrefix && stationInfoSrc?.meterSerialNumber
+ ? (stationInfoDst.meterSerialNumber = stationInfoSrc.meterSerialNumber)
+ : stationInfoDst?.meterSerialNumber && delete stationInfoDst.meterSerialNumber;
+};
- public static createSerialNumber(
- stationTemplate: ChargingStationTemplate,
- stationInfo: ChargingStationInfo = {} as ChargingStationInfo,
- params: {
- randomSerialNumberUpperCase?: boolean;
- randomSerialNumber?: boolean;
- } = {
- randomSerialNumberUpperCase: true,
- randomSerialNumber: true,
- }
- ): void {
- params = params ?? {};
- params.randomSerialNumberUpperCase = params?.randomSerialNumberUpperCase ?? true;
- params.randomSerialNumber = params?.randomSerialNumber ?? true;
- const serialNumberSuffix = params?.randomSerialNumber
- ? ChargingStationUtils.getRandomSerialNumberSuffix({
- upperCase: params.randomSerialNumberUpperCase,
- })
- : '';
- stationInfo.chargePointSerialNumber =
- stationTemplate?.chargePointSerialNumberPrefix &&
- stationTemplate.chargePointSerialNumberPrefix + serialNumberSuffix;
- stationInfo.chargeBoxSerialNumber =
- stationTemplate?.chargeBoxSerialNumberPrefix &&
- stationTemplate.chargeBoxSerialNumberPrefix + serialNumberSuffix;
- stationInfo.meterSerialNumber =
- stationTemplate?.meterSerialNumberPrefix &&
- stationTemplate.meterSerialNumberPrefix + serialNumberSuffix;
+export const getAmperageLimitationUnitDivider = (stationInfo: ChargingStationInfo): number => {
+ let unitDivider = 1;
+ switch (stationInfo.amperageLimitationUnit) {
+ case AmpereUnits.DECI_AMPERE:
+ unitDivider = 10;
+ break;
+ case AmpereUnits.CENTI_AMPERE:
+ unitDivider = 100;
+ break;
+ case AmpereUnits.MILLI_AMPERE:
+ unitDivider = 1000;
+ break;
}
+ return unitDivider;
+};
- public static propagateSerialNumber(
- stationTemplate: ChargingStationTemplate,
- stationInfoSrc: ChargingStationInfo,
- stationInfoDst: ChargingStationInfo = {} as ChargingStationInfo
- ) {
- if (!stationInfoSrc || !stationTemplate) {
- throw new BaseError(
- 'Missing charging station template or existing configuration to propagate serial number'
- );
+export const getChargingStationConnectorChargingProfilesPowerLimit = (
+ chargingStation: ChargingStation,
+ connectorId: number,
+): number | undefined => {
+ let limit: number | undefined, matchingChargingProfile: ChargingProfile | undefined;
+ // Get charging profiles for connector and sort by stack level
+ const chargingProfiles =
+ cloneObject<ChargingProfile[]>(
+ chargingStation.getConnectorStatus(connectorId)!.chargingProfiles!,
+ )?.sort((a, b) => b.stackLevel - a.stackLevel) ?? [];
+ // Get profiles on connector 0
+ if (chargingStation.getConnectorStatus(0)?.chargingProfiles) {
+ chargingProfiles.push(
+ ...cloneObject<ChargingProfile[]>(
+ chargingStation.getConnectorStatus(0)!.chargingProfiles!,
+ ).sort((a, b) => b.stackLevel - a.stackLevel),
+ );
+ }
+ if (isNotEmptyArray(chargingProfiles)) {
+ const result = getLimitFromChargingProfiles(chargingProfiles, chargingStation.logPrefix());
+ if (!isNullOrUndefined(result)) {
+ limit = result?.limit;
+ matchingChargingProfile = result?.matchingChargingProfile;
+ switch (chargingStation.getCurrentOutType()) {
+ case CurrentType.AC:
+ limit =
+ matchingChargingProfile?.chargingSchedule?.chargingRateUnit ===
+ ChargingRateUnitType.WATT
+ ? limit
+ : ACElectricUtils.powerTotal(
+ chargingStation.getNumberOfPhases(),
+ chargingStation.getVoltageOut(),
+ limit!,
+ );
+ break;
+ case CurrentType.DC:
+ limit =
+ matchingChargingProfile?.chargingSchedule?.chargingRateUnit ===
+ ChargingRateUnitType.WATT
+ ? limit
+ : DCElectricUtils.power(chargingStation.getVoltageOut(), limit!);
+ }
+ const connectorMaximumPower =
+ chargingStation.getMaximumPower() / chargingStation.powerDivider;
+ if (limit! > connectorMaximumPower) {
+ logger.error(
+ `${chargingStation.logPrefix()} Charging profile id ${matchingChargingProfile?.chargingProfileId} limit ${limit} is greater than connector id ${connectorId} maximum ${connectorMaximumPower}: %j`,
+ result,
+ );
+ limit = connectorMaximumPower;
+ }
}
- stationTemplate?.chargePointSerialNumberPrefix && stationInfoSrc?.chargePointSerialNumber
- ? (stationInfoDst.chargePointSerialNumber = stationInfoSrc.chargePointSerialNumber)
- : stationInfoDst?.chargePointSerialNumber && delete stationInfoDst.chargePointSerialNumber;
- stationTemplate?.chargeBoxSerialNumberPrefix && stationInfoSrc?.chargeBoxSerialNumber
- ? (stationInfoDst.chargeBoxSerialNumber = stationInfoSrc.chargeBoxSerialNumber)
- : stationInfoDst?.chargeBoxSerialNumber && delete stationInfoDst.chargeBoxSerialNumber;
- stationTemplate?.meterSerialNumberPrefix && stationInfoSrc?.meterSerialNumber
- ? (stationInfoDst.meterSerialNumber = stationInfoSrc.meterSerialNumber)
- : stationInfoDst?.meterSerialNumber && delete stationInfoDst.meterSerialNumber;
}
+ return limit;
+};
- public static getAmperageLimitationUnitDivider(stationInfo: ChargingStationInfo): number {
- let unitDivider = 1;
- switch (stationInfo.amperageLimitationUnit) {
- case AmpereUnits.DECI_AMPERE:
- unitDivider = 10;
- break;
- case AmpereUnits.CENTI_AMPERE:
- unitDivider = 100;
- break;
- case AmpereUnits.MILLI_AMPERE:
- unitDivider = 1000;
- break;
- }
- return unitDivider;
+export const getDefaultVoltageOut = (
+ currentType: CurrentType,
+ logPrefix: string,
+ templateFile: string,
+): Voltage => {
+ const errorMsg = `Unknown ${currentType} currentOutType in template file ${templateFile}, cannot define default voltage out`;
+ let defaultVoltageOut: number;
+ switch (currentType) {
+ case CurrentType.AC:
+ defaultVoltageOut = Voltage.VOLTAGE_230;
+ break;
+ case CurrentType.DC:
+ defaultVoltageOut = Voltage.VOLTAGE_400;
+ break;
+ default:
+ logger.error(`${logPrefix} ${errorMsg}`);
+ throw new BaseError(errorMsg);
}
+ return defaultVoltageOut;
+};
- /**
- * Charging profiles should already be sorted by connectorId and stack level (highest stack level has priority)
- *
- * @param {ChargingProfile[]} chargingProfiles
- * @param {string} logPrefix
- * @returns {{ limit, matchingChargingProfile }}
- */
- public static getLimitFromChargingProfiles(
- chargingProfiles: ChargingProfile[],
- logPrefix: string
- ): {
- limit: number;
- matchingChargingProfile: ChargingProfile;
- } | null {
- for (const chargingProfile of chargingProfiles) {
- // Set helpers
- const currentMoment = moment();
- const chargingSchedule = chargingProfile.chargingSchedule;
- // Check type (recurring) and if it is already active
- // Adjust the daily recurring schedule to today
- if (
- chargingProfile.chargingProfileKind === ChargingProfileKindType.RECURRING &&
- chargingProfile.recurrencyKind === RecurrencyKindType.DAILY &&
- currentMoment.isAfter(chargingSchedule.startSchedule)
- ) {
- const currentDate = new Date();
- chargingSchedule.startSchedule = new Date(chargingSchedule.startSchedule);
- chargingSchedule.startSchedule.setFullYear(
- currentDate.getFullYear(),
- currentDate.getMonth(),
- currentDate.getDate()
- );
- // Check if the start of the schedule is yesterday
- if (moment(chargingSchedule.startSchedule).isAfter(currentMoment)) {
- chargingSchedule.startSchedule.setDate(currentDate.getDate() - 1);
- }
- } else if (moment(chargingSchedule.startSchedule).isAfter(currentMoment)) {
- return null;
+export const getIdTagsFile = (stationInfo: ChargingStationInfo): string | undefined => {
+ return (
+ stationInfo.idTagsFile &&
+ join(dirname(fileURLToPath(import.meta.url)), 'assets', basename(stationInfo.idTagsFile))
+ );
+};
+
+export const waitChargingStationEvents = async (
+ emitter: EventEmitter,
+ event: ChargingStationWorkerMessageEvents,
+ eventsToWait: number,
+): Promise<number> => {
+ return new Promise<number>((resolve) => {
+ let events = 0;
+ if (eventsToWait === 0) {
+ resolve(events);
+ }
+ emitter.on(event, () => {
+ ++events;
+ if (events === eventsToWait) {
+ resolve(events);
}
- // Check if the charging profile is active
- if (
- moment(chargingSchedule.startSchedule)
- .add(chargingSchedule.duration, 's')
- .isAfter(currentMoment)
- ) {
- let lastButOneSchedule: ChargingSchedulePeriod;
- // Search the right schedule period
- for (const schedulePeriod of chargingSchedule.chargingSchedulePeriod) {
- // Handling of only one period
- if (
- chargingSchedule.chargingSchedulePeriod.length === 1 &&
- schedulePeriod.startPeriod === 0
- ) {
- const result = {
- limit: schedulePeriod.limit,
- matchingChargingProfile: chargingProfile,
- };
- logger.debug(
- `${logPrefix} Matching charging profile found for power limitation: %j`,
- result
- );
- return result;
- }
- // Find the right schedule period
- if (
- moment(chargingSchedule.startSchedule)
- .add(schedulePeriod.startPeriod, 's')
- .isAfter(currentMoment)
- ) {
- // Found the schedule: last but one is the correct one
- const result = {
- limit: lastButOneSchedule.limit,
- matchingChargingProfile: chargingProfile,
- };
- logger.debug(
- `${logPrefix} Matching charging profile found for power limitation: %j`,
- result
- );
- return result;
- }
- // Keep it
- lastButOneSchedule = schedulePeriod;
- // Handle the last schedule period
- if (
- schedulePeriod.startPeriod ===
- chargingSchedule.chargingSchedulePeriod[
- chargingSchedule.chargingSchedulePeriod.length - 1
- ].startPeriod
- ) {
- const result = {
- limit: lastButOneSchedule.limit,
- matchingChargingProfile: chargingProfile,
- };
- logger.debug(
- `${logPrefix} Matching charging profile found for power limitation: %j`,
- result
- );
- return result;
- }
- }
+ });
+ });
+};
+
+const getConfiguredNumberOfConnectors = (stationTemplate: ChargingStationTemplate): number => {
+ let configuredMaxConnectors = 0;
+ if (isNotEmptyArray(stationTemplate.numberOfConnectors) === true) {
+ const numberOfConnectors = stationTemplate.numberOfConnectors as number[];
+ configuredMaxConnectors =
+ numberOfConnectors[Math.floor(secureRandom() * numberOfConnectors.length)];
+ } else if (isUndefined(stationTemplate.numberOfConnectors) === false) {
+ configuredMaxConnectors = stationTemplate.numberOfConnectors as number;
+ } else if (stationTemplate.Connectors && !stationTemplate.Evses) {
+ configuredMaxConnectors = stationTemplate.Connectors[0]
+ ? getMaxNumberOfConnectors(stationTemplate.Connectors) - 1
+ : getMaxNumberOfConnectors(stationTemplate.Connectors);
+ } else if (stationTemplate.Evses && !stationTemplate.Connectors) {
+ for (const evse in stationTemplate.Evses) {
+ if (evse === '0') {
+ continue;
}
+ configuredMaxConnectors += getMaxNumberOfConnectors(stationTemplate.Evses[evse].Connectors);
}
- return null;
}
+ return configuredMaxConnectors;
+};
+
+const checkConfiguredMaxConnectors = (
+ configuredMaxConnectors: number,
+ logPrefix: string,
+ templateFile: string,
+): void => {
+ if (configuredMaxConnectors <= 0) {
+ logger.warn(
+ `${logPrefix} Charging station information from template ${templateFile} with ${configuredMaxConnectors} connectors`,
+ );
+ }
+};
+
+const checkTemplateMaxConnectors = (
+ templateMaxConnectors: number,
+ logPrefix: string,
+ templateFile: string,
+): void => {
+ if (templateMaxConnectors === 0) {
+ logger.warn(
+ `${logPrefix} Charging station information from template ${templateFile} with empty connectors configuration`,
+ );
+ } else if (templateMaxConnectors < 0) {
+ logger.error(
+ `${logPrefix} Charging station information from template ${templateFile} with no connectors configuration defined`,
+ );
+ }
+};
+
+const initializeConnectorStatus = (connectorStatus: ConnectorStatus): void => {
+ connectorStatus.availability = AvailabilityType.Operative;
+ connectorStatus.idTagLocalAuthorized = false;
+ connectorStatus.idTagAuthorized = false;
+ connectorStatus.transactionRemoteStarted = false;
+ connectorStatus.transactionStarted = false;
+ connectorStatus.energyActiveImportRegisterValue = 0;
+ connectorStatus.transactionEnergyActiveImportRegisterValue = 0;
+ if (isUndefined(connectorStatus.chargingProfiles)) {
+ connectorStatus.chargingProfiles = [];
+ }
+};
+
+const warnDeprecatedTemplateKey = (
+ template: ChargingStationTemplate,
+ key: string,
+ logPrefix: string,
+ templateFile: string,
+ logMsgToAppend = '',
+): void => {
+ if (!isUndefined(template[key as keyof ChargingStationTemplate])) {
+ const logMsg = `Deprecated template key '${key}' usage in file '${templateFile}'${
+ isNotEmptyString(logMsgToAppend) ? `. ${logMsgToAppend}` : ''
+ }`;
+ logger.warn(`${logPrefix} ${logMsg}`);
+ console.warn(chalk.yellow(`${logMsg}`));
+ }
+};
- public static getDefaultVoltageOut(
- currentType: CurrentType,
- templateFile: string,
- logPrefix: string
- ): Voltage {
- const errMsg = `${logPrefix} Unknown ${currentType} currentOutType in template file ${templateFile}, cannot define default voltage out`;
- let defaultVoltageOut: number;
- switch (currentType) {
- case CurrentType.AC:
- defaultVoltageOut = Voltage.VOLTAGE_230;
- break;
- case CurrentType.DC:
- defaultVoltageOut = Voltage.VOLTAGE_400;
- break;
- default:
- logger.error(errMsg);
- throw new Error(errMsg);
+const convertDeprecatedTemplateKey = (
+ template: ChargingStationTemplate,
+ deprecatedKey: string,
+ key?: string,
+): void => {
+ if (!isUndefined(template[deprecatedKey as keyof ChargingStationTemplate])) {
+ if (!isUndefined(key)) {
+ (template as unknown as Record<string, unknown>)[key!] =
+ template[deprecatedKey as keyof ChargingStationTemplate];
}
- return defaultVoltageOut;
+ delete template[deprecatedKey as keyof ChargingStationTemplate];
}
+};
- public static getSampledValueTemplate(
- chargingStation: ChargingStation,
- connectorId: number,
- measurand: MeterValueMeasurand = MeterValueMeasurand.ENERGY_ACTIVE_IMPORT_REGISTER,
- phase?: MeterValuePhase
- ): SampledValueTemplate | undefined {
- const onPhaseStr = phase ? `on phase ${phase} ` : '';
- if (!Constants.SUPPORTED_MEASURANDS.includes(measurand)) {
+/**
+ * Charging profiles should already be sorted by connector id and stack level (highest stack level has priority)
+ *
+ * @param chargingProfiles -
+ * @param logPrefix -
+ * @returns
+ */
+const getLimitFromChargingProfiles = (
+ chargingProfiles: ChargingProfile[],
+ logPrefix: string,
+):
+ | {
+ limit: number;
+ matchingChargingProfile: ChargingProfile;
+ }
+ | undefined => {
+ const debugLogMsg = `${logPrefix} ${moduleName}.getLimitFromChargingProfiles: Matching charging profile found for power limitation: %j`;
+ const currentDate = new Date();
+ for (const chargingProfile of chargingProfiles) {
+ // Set helpers
+ const chargingSchedule = chargingProfile.chargingSchedule;
+ if (!chargingSchedule?.startSchedule) {
logger.warn(
- `${chargingStation.logPrefix()} Trying to get unsupported MeterValues measurand '${measurand}' ${onPhaseStr}in template on connectorId ${connectorId}`
+ `${logPrefix} ${moduleName}.getLimitFromChargingProfiles: startSchedule is not defined in charging profile id ${chargingProfile.chargingProfileId}`,
);
- return;
}
- if (
- measurand !== MeterValueMeasurand.ENERGY_ACTIVE_IMPORT_REGISTER &&
- !ChargingStationConfigurationUtils.getConfigurationKey(
- chargingStation,
- StandardParametersKey.MeterValuesSampledData
- )?.value.includes(measurand)
- ) {
- logger.debug(
- `${chargingStation.logPrefix()} Trying to get MeterValues measurand '${measurand}' ${onPhaseStr}in template on connectorId ${connectorId} not found in '${
- StandardParametersKey.MeterValuesSampledData
- }' OCPP parameter`
+ if (!(chargingSchedule?.startSchedule instanceof Date)) {
+ logger.warn(
+ `${logPrefix} ${moduleName}.getLimitFromChargingProfiles: startSchedule is not a Date object in charging profile id ${chargingProfile.chargingProfileId}. Trying to convert it to a Date object`,
);
- return;
+ chargingSchedule.startSchedule = convertToDate(chargingSchedule.startSchedule)!;
}
- const sampledValueTemplates: SampledValueTemplate[] =
- chargingStation.getConnectorStatus(connectorId).MeterValues;
- for (
- let index = 0;
- !Utils.isEmptyArray(sampledValueTemplates) && index < sampledValueTemplates.length;
- index++
- ) {
- if (
- !Constants.SUPPORTED_MEASURANDS.includes(
- sampledValueTemplates[index]?.measurand ??
- MeterValueMeasurand.ENERGY_ACTIVE_IMPORT_REGISTER
- )
- ) {
- logger.warn(
- `${chargingStation.logPrefix()} Unsupported MeterValues measurand '${measurand}' ${onPhaseStr}in template on connectorId ${connectorId}`
- );
- } else if (
- phase &&
- sampledValueTemplates[index]?.phase === phase &&
- sampledValueTemplates[index]?.measurand === measurand &&
- ChargingStationConfigurationUtils.getConfigurationKey(
- chargingStation,
- StandardParametersKey.MeterValuesSampledData
- )?.value.includes(measurand)
- ) {
- return sampledValueTemplates[index];
- } else if (
- !phase &&
- !sampledValueTemplates[index].phase &&
- sampledValueTemplates[index]?.measurand === measurand &&
- ChargingStationConfigurationUtils.getConfigurationKey(
- chargingStation,
- StandardParametersKey.MeterValuesSampledData
- )?.value.includes(measurand)
- ) {
- return sampledValueTemplates[index];
- } else if (
- measurand === MeterValueMeasurand.ENERGY_ACTIVE_IMPORT_REGISTER &&
- (!sampledValueTemplates[index].measurand ||
- sampledValueTemplates[index].measurand === measurand)
- ) {
- return sampledValueTemplates[index];
+ // Adjust recurring start schedule
+ if (chargingProfile.chargingProfileKind === ChargingProfileKindType.RECURRING) {
+ switch (chargingProfile.recurrencyKind) {
+ case RecurrencyKindType.DAILY:
+ if (isBefore(chargingSchedule.startSchedule, startOfDay(currentDate))) {
+ addDays(
+ chargingSchedule.startSchedule,
+ differenceInDays(chargingSchedule.startSchedule, endOfDay(currentDate)),
+ );
+ }
+ break;
+ case RecurrencyKindType.WEEKLY:
+ if (isBefore(chargingSchedule.startSchedule, startOfWeek(currentDate))) {
+ addWeeks(
+ chargingSchedule.startSchedule,
+ differenceInWeeks(chargingSchedule.startSchedule, endOfWeek(currentDate)),
+ );
+ }
+ break;
}
}
- if (measurand === MeterValueMeasurand.ENERGY_ACTIVE_IMPORT_REGISTER) {
- const errorMsg = `${chargingStation.logPrefix()} Missing MeterValues for default measurand '${measurand}' in template on connectorId ${connectorId}`;
- logger.error(errorMsg);
- throw new Error(errorMsg);
- }
- logger.debug(
- `${chargingStation.logPrefix()} No MeterValues for measurand '${measurand}' ${onPhaseStr}in template on connectorId ${connectorId}`
- );
- }
-
- public static getAuthorizedTags(
- stationInfo: ChargingStationInfo,
- templateFile: string,
- logPrefix: string
- ): string[] {
- let authorizedTags: string[] = [];
- const authorizationFile = ChargingStationUtils.getAuthorizationFile(stationInfo);
- if (authorizationFile) {
- try {
- // Load authorization file
- authorizedTags = JSON.parse(fs.readFileSync(authorizationFile, 'utf8')) as string[];
- } catch (error) {
- FileUtils.handleFileException(
- logPrefix,
- FileType.Authorization,
- authorizationFile,
- error as NodeJS.ErrnoException
- );
+ // Check if the charging profile is active
+ if (
+ isAfter(addSeconds(chargingSchedule.startSchedule, chargingSchedule.duration!), currentDate)
+ ) {
+ let lastButOneSchedule: ChargingSchedulePeriod | undefined;
+ // Search the right schedule period
+ for (const schedulePeriod of chargingSchedule.chargingSchedulePeriod) {
+ // Handling of only one period
+ if (
+ chargingSchedule.chargingSchedulePeriod.length === 1 &&
+ schedulePeriod.startPeriod === 0
+ ) {
+ const result = {
+ limit: schedulePeriod.limit,
+ matchingChargingProfile: chargingProfile,
+ };
+ logger.debug(debugLogMsg, result);
+ return result;
+ }
+ // Find the right schedule period
+ if (
+ isAfter(
+ addSeconds(chargingSchedule.startSchedule, schedulePeriod.startPeriod),
+ currentDate,
+ )
+ ) {
+ // Found the schedule: last but one is the correct one
+ const result = {
+ limit: lastButOneSchedule!.limit,
+ matchingChargingProfile: chargingProfile,
+ };
+ logger.debug(debugLogMsg, result);
+ return result;
+ }
+ // Keep it
+ lastButOneSchedule = schedulePeriod;
+ // Handle the last schedule period
+ if (
+ schedulePeriod.startPeriod ===
+ chargingSchedule.chargingSchedulePeriod[
+ chargingSchedule.chargingSchedulePeriod.length - 1
+ ].startPeriod
+ ) {
+ const result = {
+ limit: lastButOneSchedule.limit,
+ matchingChargingProfile: chargingProfile,
+ };
+ logger.debug(debugLogMsg, result);
+ return result;
+ }
}
- } else {
- logger.info(logPrefix + ' No authorization file given in template file ' + templateFile);
}
- return authorizedTags;
- }
-
- public static getAuthorizationFile(stationInfo: ChargingStationInfo): string | undefined {
- return (
- stationInfo.authorizationFile &&
- path.join(
- path.resolve(__dirname, '../'),
- 'assets',
- path.basename(stationInfo.authorizationFile)
- )
- );
- }
-
- public static isChargingStationConfigurationCacheable(
- chargingStationConfiguration: ChargingStationConfiguration
- ): boolean {
- return (
- !Utils.isNullOrUndefined(chargingStationConfiguration?.configurationKey) &&
- !Utils.isNullOrUndefined(chargingStationConfiguration?.stationInfo) &&
- !Utils.isNullOrUndefined(chargingStationConfiguration?.configurationHash) &&
- !Utils.isEmptyArray(chargingStationConfiguration?.configurationKey) &&
- !Utils.isEmptyObject(chargingStationConfiguration?.stationInfo) &&
- !Utils.isEmptyString(chargingStationConfiguration?.configurationHash)
- );
}
+};
- private static getRandomSerialNumberSuffix(params?: {
- randomBytesLength?: number;
- upperCase?: boolean;
- }): string {
- const randomSerialNumberSuffix = crypto
- .randomBytes(params?.randomBytesLength ?? 16)
- .toString('hex');
- if (params?.upperCase) {
- return randomSerialNumberSuffix.toUpperCase();
- }
- return randomSerialNumberSuffix;
+const getRandomSerialNumberSuffix = (params?: {
+ randomBytesLength?: number;
+ upperCase?: boolean;
+}): string => {
+ const randomSerialNumberSuffix = randomBytes(params?.randomBytesLength ?? 16).toString('hex');
+ if (params?.upperCase) {
+ return randomSerialNumberSuffix.toUpperCase();
}
-}
+ return randomSerialNumberSuffix;
+};