Add occpStrictCompliance template tunable
[e-mobility-charging-stations-simulator.git] / src / charging-station / ocpp / 1.6 / OCPP16RequestService.ts
index eb502d6ef38c84bf28cce7ca3aaeb8fc01798676..3580cc52e18701ff05f8a6939b6714bb5be9113a 100644 (file)
@@ -1,34 +1,41 @@
+// Partial Copyright Jerome Benoit. 2021. All Rights Reserved.
+
 import { ACElectricUtils, DCElectricUtils } from '../../../utils/ElectricUtils';
 import { AuthorizeRequest, OCPP16AuthorizeResponse, OCPP16StartTransactionResponse, OCPP16StopTransactionReason, OCPP16StopTransactionResponse, StartTransactionRequest, StopTransactionRequest } from '../../../types/ocpp/1.6/Transaction';
-import { CurrentOutType, VoltageOut } from '../../../types/ChargingStationTemplate';
-import { HeartbeatRequest, OCPP16BootNotificationRequest, OCPP16IncomingRequestCommand, OCPP16RequestCommand, StatusNotificationRequest } from '../../../types/ocpp/1.6/Requests';
+import { CurrentType, Voltage } from '../../../types/ChargingStationTemplate';
+import { DiagnosticsStatusNotificationRequest, HeartbeatRequest, OCPP16BootNotificationRequest, OCPP16IncomingRequestCommand, OCPP16RequestCommand, StatusNotificationRequest } from '../../../types/ocpp/1.6/Requests';
 import { MeterValueUnit, MeterValuesRequest, OCPP16MeterValue, OCPP16MeterValueMeasurand, OCPP16MeterValuePhase } from '../../../types/ocpp/1.6/MeterValues';
 
 import Constants from '../../../utils/Constants';
+import { ErrorType } from '../../../types/ocpp/ErrorType';
+import { JsonType } from '../../../types/JsonType';
 import MeasurandPerPhaseSampledValueTemplates from '../../../types/MeasurandPerPhaseSampledValueTemplates';
 import MeasurandValues from '../../../types/MeasurandValues';
 import { MessageType } from '../../../types/ocpp/MessageType';
 import { OCPP16BootNotificationResponse } from '../../../types/ocpp/1.6/Responses';
 import { OCPP16ChargePointErrorCode } from '../../../types/ocpp/1.6/ChargePointErrorCode';
 import { OCPP16ChargePointStatus } from '../../../types/ocpp/1.6/ChargePointStatus';
+import { OCPP16DiagnosticsStatus } from '../../../types/ocpp/1.6/DiagnosticsStatus';
 import { OCPP16ServiceUtils } from './OCPP16ServiceUtils';
-import OCPPError from '../../OcppError';
+import OCPPError from '../../../exception/OCPPError';
 import OCPPRequestService from '../OCPPRequestService';
+import { SendParams } from '../../../types/ocpp/Requests';
 import Utils from '../../../utils/Utils';
 import logger from '../../../utils/Logger';
 
 export default class OCPP16RequestService extends OCPPRequestService {
-  public async sendHeartbeat(): Promise<void> {
+  public async sendHeartbeat(params?: SendParams): Promise<void> {
     try {
       const payload: HeartbeatRequest = {};
-      await this.sendMessage(Utils.generateUUID(), payload, MessageType.CALL_MESSAGE, OCPP16RequestCommand.HEARTBEAT);
+      await this.sendMessage(Utils.generateUUID(), payload, MessageType.CALL_MESSAGE, OCPP16RequestCommand.HEARTBEAT, params);
     } catch (error) {
-      this.handleRequestError(OCPP16RequestCommand.HEARTBEAT, error);
+      this.handleRequestError(OCPP16RequestCommand.HEARTBEAT, error as Error);
     }
   }
 
   public async sendBootNotification(chargePointModel: string, chargePointVendor: string, chargeBoxSerialNumber?: string, firmwareVersion?: string,
-      chargePointSerialNumber?: string, iccid?: string, imsi?: string, meterSerialNumber?: string, meterType?: string): Promise<OCPP16BootNotificationResponse> {
+      chargePointSerialNumber?: string, iccid?: string, imsi?: string, meterSerialNumber?: string, meterType?: string,
+      params?: SendParams): Promise<OCPP16BootNotificationResponse> {
     try {
       const payload: OCPP16BootNotificationRequest = {
         chargePointModel,
@@ -41,9 +48,10 @@ export default class OCPP16RequestService extends OCPPRequestService {
         ...!Utils.isUndefined(meterSerialNumber) && { meterSerialNumber },
         ...!Utils.isUndefined(meterType) && { meterType }
       };
-      return await this.sendMessage(Utils.generateUUID(), payload, MessageType.CALL_MESSAGE, OCPP16RequestCommand.BOOT_NOTIFICATION) as OCPP16BootNotificationResponse;
+      return await this.sendMessage(Utils.generateUUID(), payload, MessageType.CALL_MESSAGE,
+        OCPP16RequestCommand.BOOT_NOTIFICATION, { ...params, skipBufferingOnError: true }) as OCPP16BootNotificationResponse;
     } catch (error) {
-      this.handleRequestError(OCPP16RequestCommand.BOOT_NOTIFICATION, error);
+      this.handleRequestError(OCPP16RequestCommand.BOOT_NOTIFICATION, error as Error);
     }
   }
 
@@ -57,7 +65,7 @@ export default class OCPP16RequestService extends OCPPRequestService {
       };
       await this.sendMessage(Utils.generateUUID(), payload, MessageType.CALL_MESSAGE, OCPP16RequestCommand.STATUS_NOTIFICATION);
     } catch (error) {
-      this.handleRequestError(OCPP16RequestCommand.STATUS_NOTIFICATION, error);
+      this.handleRequestError(OCPP16RequestCommand.STATUS_NOTIFICATION, error as Error);
     }
   }
 
@@ -66,10 +74,10 @@ export default class OCPP16RequestService extends OCPPRequestService {
       const payload: AuthorizeRequest = {
         ...!Utils.isUndefined(idTag) ? { idTag } : { idTag: Constants.TRANSACTION_DEFAULT_IDTAG },
       };
-      this.chargingStation.getConnector(connectorId).authorizeIdTag = idTag;
+      this.chargingStation.getConnectorStatus(connectorId).authorizeIdTag = idTag;
       return await this.sendMessage(Utils.generateUUID(), payload, MessageType.CALL_MESSAGE, OCPP16RequestCommand.AUTHORIZE) as OCPP16AuthorizeResponse;
     } catch (error) {
-      this.handleRequestError(OCPP16RequestCommand.AUTHORIZE, error);
+      this.handleRequestError(OCPP16RequestCommand.AUTHORIZE, error as Error);
     }
   }
 
@@ -83,7 +91,7 @@ export default class OCPP16RequestService extends OCPPRequestService {
       };
       return await this.sendMessage(Utils.generateUUID(), payload, MessageType.CALL_MESSAGE, OCPP16RequestCommand.START_TRANSACTION) as OCPP16StartTransactionResponse;
     } catch (error) {
-      this.handleRequestError(OCPP16RequestCommand.START_TRANSACTION, error);
+      this.handleRequestError(OCPP16RequestCommand.START_TRANSACTION, error as Error);
     }
   }
 
@@ -91,15 +99,15 @@ export default class OCPP16RequestService extends OCPPRequestService {
       reason: OCPP16StopTransactionReason = OCPP16StopTransactionReason.NONE): Promise<OCPP16StopTransactionResponse> {
     try {
       let connectorId: number;
-      for (const connector in this.chargingStation.connectors) {
-        if (Utils.convertToInt(connector) > 0 && this.chargingStation.getConnector(Utils.convertToInt(connector))?.transactionId === transactionId) {
-          connectorId = Utils.convertToInt(connector);
+      for (const id of this.chargingStation.connectors.keys()) {
+        if (id > 0 && this.chargingStation.getConnectorStatus(id)?.transactionId === transactionId) {
+          connectorId = id;
           break;
         }
       }
       const transactionEndMeterValue = OCPP16ServiceUtils.buildTransactionEndMeterValue(this.chargingStation, connectorId, meterStop);
       // FIXME: should be a callback, each OCPP commands implementation must do only one job
-      (this.chargingStation.getBeginEndMeterValues() && !this.chargingStation.getOutOfOrderEndMeterValues())
+      (this.chargingStation.getBeginEndMeterValues() && this.chargingStation.getOcppStrictCompliance() && !this.chargingStation.getOutOfOrderEndMeterValues())
         && await this.sendTransactionEndMeterValues(connectorId, transactionId, transactionEndMeterValue);
       const payload: StopTransactionRequest = {
         transactionId,
@@ -107,89 +115,91 @@ export default class OCPP16RequestService extends OCPPRequestService {
         meterStop,
         timestamp: new Date().toISOString(),
         ...reason && { reason },
-        ...this.chargingStation.getTransactionDataMeterValues() && { transactionData: OCPP16ServiceUtils.buildTransactionDataMeterValues(this.chargingStation.getConnector(connectorId).transactionBeginMeterValue, transactionEndMeterValue) },
+        ...this.chargingStation.getTransactionDataMeterValues() && { transactionData: OCPP16ServiceUtils.buildTransactionDataMeterValues(this.chargingStation.getConnectorStatus(connectorId).transactionBeginMeterValue, transactionEndMeterValue) },
       };
       return await this.sendMessage(Utils.generateUUID(), payload, MessageType.CALL_MESSAGE, OCPP16RequestCommand.STOP_TRANSACTION) as OCPP16StartTransactionResponse;
     } catch (error) {
-      this.handleRequestError(OCPP16RequestCommand.STOP_TRANSACTION, error);
+      this.handleRequestError(OCPP16RequestCommand.STOP_TRANSACTION, error as Error);
     }
   }
 
-  // eslint-disable-next-line consistent-this
-  public async sendMeterValues(connectorId: number, transactionId: number, interval: number, self: OCPPRequestService, debug = false): Promise<void> {
+  public async sendMeterValues(connectorId: number, transactionId: number, interval: number, debug = false): Promise<void> {
     try {
       const meterValue: OCPP16MeterValue = {
         timestamp: new Date().toISOString(),
         sampledValue: [],
       };
-      const connector = self.chargingStation.getConnector(connectorId);
+      const connector = this.chargingStation.getConnectorStatus(connectorId);
       // SoC measurand
-      const socSampledValueTemplate = self.chargingStation.getSampledValueTemplate(connectorId, OCPP16MeterValueMeasurand.STATE_OF_CHARGE);
+      const socSampledValueTemplate = this.chargingStation.getSampledValueTemplate(connectorId, OCPP16MeterValueMeasurand.STATE_OF_CHARGE);
       if (socSampledValueTemplate) {
-        meterValue.sampledValue.push(OCPP16ServiceUtils.buildSampledValue(socSampledValueTemplate, Utils.getRandomInt(100)));
+        const socSampledValueTemplateValue = socSampledValueTemplate.value
+          ? Utils.getRandomFloatFluctuatedRounded(parseInt(socSampledValueTemplate.value), socSampledValueTemplate.fluctuationPercent ?? Constants.DEFAULT_FLUCTUATION_PERCENT)
+          : Utils.getRandomInteger(100);
+        meterValue.sampledValue.push(OCPP16ServiceUtils.buildSampledValue(socSampledValueTemplate, socSampledValueTemplateValue));
         const sampledValuesIndex = meterValue.sampledValue.length - 1;
         if (Utils.convertToInt(meterValue.sampledValue[sampledValuesIndex].value) > 100 || debug) {
-          logger.error(`${self.chargingStation.logPrefix()} MeterValues measurand ${meterValue.sampledValue[sampledValuesIndex].measurand ?? OCPP16MeterValueMeasurand.ENERGY_ACTIVE_IMPORT_REGISTER}: connectorId ${connectorId}, transaction ${connector.transactionId}, value: ${meterValue.sampledValue[sampledValuesIndex].value}/100`);
+          logger.error(`${this.chargingStation.logPrefix()} MeterValues measurand ${meterValue.sampledValue[sampledValuesIndex].measurand ?? OCPP16MeterValueMeasurand.ENERGY_ACTIVE_IMPORT_REGISTER}: connectorId ${connectorId}, transaction ${connector.transactionId}, value: ${meterValue.sampledValue[sampledValuesIndex].value}/100`);
         }
       }
       // Voltage measurand
-      const voltageSampledValueTemplate = self.chargingStation.getSampledValueTemplate(connectorId, OCPP16MeterValueMeasurand.VOLTAGE);
+      const voltageSampledValueTemplate = this.chargingStation.getSampledValueTemplate(connectorId, OCPP16MeterValueMeasurand.VOLTAGE);
       if (voltageSampledValueTemplate) {
-        const voltageSampledValueTemplateValue = voltageSampledValueTemplate.value ? parseInt(voltageSampledValueTemplate.value) : self.chargingStation.getVoltageOut();
+        const voltageSampledValueTemplateValue = voltageSampledValueTemplate.value ? parseInt(voltageSampledValueTemplate.value) : this.chargingStation.getVoltageOut();
         const fluctuationPercent = voltageSampledValueTemplate.fluctuationPercent ?? Constants.DEFAULT_FLUCTUATION_PERCENT;
         const voltageMeasurandValue = Utils.getRandomFloatFluctuatedRounded(voltageSampledValueTemplateValue, fluctuationPercent);
-        if (self.chargingStation.getNumberOfPhases() !== 3 || (self.chargingStation.getNumberOfPhases() === 3 && self.chargingStation.getMainVoltageMeterValues())) {
+        if (this.chargingStation.getNumberOfPhases() !== 3 || (this.chargingStation.getNumberOfPhases() === 3 && this.chargingStation.getMainVoltageMeterValues())) {
           meterValue.sampledValue.push(OCPP16ServiceUtils.buildSampledValue(voltageSampledValueTemplate, voltageMeasurandValue));
         }
-        for (let phase = 1; self.chargingStation.getNumberOfPhases() === 3 && phase <= self.chargingStation.getNumberOfPhases(); phase++) {
+        for (let phase = 1; this.chargingStation.getNumberOfPhases() === 3 && phase <= this.chargingStation.getNumberOfPhases(); phase++) {
           const phaseLineToNeutralValue = `L${phase}-N`;
-          const voltagePhaseLineToNeutralSampledValueTemplate = self.chargingStation.getSampledValueTemplate(connectorId, OCPP16MeterValueMeasurand.VOLTAGE,
+          const voltagePhaseLineToNeutralSampledValueTemplate = this.chargingStation.getSampledValueTemplate(connectorId, OCPP16MeterValueMeasurand.VOLTAGE,
             phaseLineToNeutralValue as OCPP16MeterValuePhase);
           let voltagePhaseLineToNeutralMeasurandValue: number;
           if (voltagePhaseLineToNeutralSampledValueTemplate) {
-            const voltagePhaseLineToNeutralSampledValueTemplateValue = voltagePhaseLineToNeutralSampledValueTemplate.value ? parseInt(voltagePhaseLineToNeutralSampledValueTemplate.value) : self.chargingStation.getVoltageOut();
+            const voltagePhaseLineToNeutralSampledValueTemplateValue = voltagePhaseLineToNeutralSampledValueTemplate.value ? parseInt(voltagePhaseLineToNeutralSampledValueTemplate.value) : this.chargingStation.getVoltageOut();
             const fluctuationPhaseToNeutralPercent = voltagePhaseLineToNeutralSampledValueTemplate.fluctuationPercent ?? Constants.DEFAULT_FLUCTUATION_PERCENT;
             voltagePhaseLineToNeutralMeasurandValue = Utils.getRandomFloatFluctuatedRounded(voltagePhaseLineToNeutralSampledValueTemplateValue, fluctuationPhaseToNeutralPercent);
           }
           meterValue.sampledValue.push(OCPP16ServiceUtils.buildSampledValue(voltagePhaseLineToNeutralSampledValueTemplate ?? voltageSampledValueTemplate,
             voltagePhaseLineToNeutralMeasurandValue ?? voltageMeasurandValue, null, phaseLineToNeutralValue as OCPP16MeterValuePhase));
-          if (self.chargingStation.getPhaseLineToLineVoltageMeterValues()) {
-            const phaseLineToLineValue = `L${phase}-L${(phase + 1) % self.chargingStation.getNumberOfPhases() !== 0 ? (phase + 1) % self.chargingStation.getNumberOfPhases() : self.chargingStation.getNumberOfPhases()}`;
-            const voltagePhaseLineToLineSampledValueTemplate = self.chargingStation.getSampledValueTemplate(connectorId, OCPP16MeterValueMeasurand.VOLTAGE, phaseLineToLineValue as OCPP16MeterValuePhase);
+          if (this.chargingStation.getPhaseLineToLineVoltageMeterValues()) {
+            const phaseLineToLineValue = `L${phase}-L${(phase + 1) % this.chargingStation.getNumberOfPhases() !== 0 ? (phase + 1) % this.chargingStation.getNumberOfPhases() : this.chargingStation.getNumberOfPhases()}`;
+            const voltagePhaseLineToLineSampledValueTemplate = this.chargingStation.getSampledValueTemplate(connectorId, OCPP16MeterValueMeasurand.VOLTAGE, phaseLineToLineValue as OCPP16MeterValuePhase);
             let voltagePhaseLineToLineMeasurandValue: number;
             if (voltagePhaseLineToLineSampledValueTemplate) {
-              const voltagePhaseLineToLineSampledValueTemplateValue = voltagePhaseLineToLineSampledValueTemplate.value ? parseInt(voltagePhaseLineToLineSampledValueTemplate.value) : VoltageOut.VOLTAGE_400;
+              const voltagePhaseLineToLineSampledValueTemplateValue = voltagePhaseLineToLineSampledValueTemplate.value ? parseInt(voltagePhaseLineToLineSampledValueTemplate.value) : Voltage.VOLTAGE_400;
               const fluctuationPhaseLineToLinePercent = voltagePhaseLineToLineSampledValueTemplate.fluctuationPercent ?? Constants.DEFAULT_FLUCTUATION_PERCENT;
               voltagePhaseLineToLineMeasurandValue = Utils.getRandomFloatFluctuatedRounded(voltagePhaseLineToLineSampledValueTemplateValue, fluctuationPhaseLineToLinePercent);
             }
-            const defaultVoltagePhaseLineToLineMeasurandValue = Utils.getRandomFloatFluctuatedRounded(VoltageOut.VOLTAGE_400, fluctuationPercent);
+            const defaultVoltagePhaseLineToLineMeasurandValue = Utils.getRandomFloatFluctuatedRounded(Voltage.VOLTAGE_400, fluctuationPercent);
             meterValue.sampledValue.push(OCPP16ServiceUtils.buildSampledValue(voltagePhaseLineToLineSampledValueTemplate ?? voltageSampledValueTemplate,
               voltagePhaseLineToLineMeasurandValue ?? defaultVoltagePhaseLineToLineMeasurandValue, null, phaseLineToLineValue as OCPP16MeterValuePhase));
           }
         }
       }
       // Power.Active.Import measurand
-      const powerSampledValueTemplate = self.chargingStation.getSampledValueTemplate(connectorId, OCPP16MeterValueMeasurand.POWER_ACTIVE_IMPORT);
+      const powerSampledValueTemplate = this.chargingStation.getSampledValueTemplate(connectorId, OCPP16MeterValueMeasurand.POWER_ACTIVE_IMPORT);
       let powerPerPhaseSampledValueTemplates: MeasurandPerPhaseSampledValueTemplates = {};
-      if (self.chargingStation.getNumberOfPhases() === 3) {
+      if (this.chargingStation.getNumberOfPhases() === 3) {
         powerPerPhaseSampledValueTemplates = {
-          L1: self.chargingStation.getSampledValueTemplate(connectorId, OCPP16MeterValueMeasurand.POWER_ACTIVE_IMPORT, OCPP16MeterValuePhase.L1_N),
-          L2: self.chargingStation.getSampledValueTemplate(connectorId, OCPP16MeterValueMeasurand.POWER_ACTIVE_IMPORT, OCPP16MeterValuePhase.L2_N),
-          L3: self.chargingStation.getSampledValueTemplate(connectorId, OCPP16MeterValueMeasurand.POWER_ACTIVE_IMPORT, OCPP16MeterValuePhase.L3_N),
+          L1: this.chargingStation.getSampledValueTemplate(connectorId, OCPP16MeterValueMeasurand.POWER_ACTIVE_IMPORT, OCPP16MeterValuePhase.L1_N),
+          L2: this.chargingStation.getSampledValueTemplate(connectorId, OCPP16MeterValueMeasurand.POWER_ACTIVE_IMPORT, OCPP16MeterValuePhase.L2_N),
+          L3: this.chargingStation.getSampledValueTemplate(connectorId, OCPP16MeterValueMeasurand.POWER_ACTIVE_IMPORT, OCPP16MeterValuePhase.L3_N),
         };
       }
       if (powerSampledValueTemplate) {
-        OCPP16ServiceUtils.checkMeasurandPowerDivider(self.chargingStation, powerSampledValueTemplate.measurand);
-        const errMsg = `${self.chargingStation.logPrefix()} MeterValues measurand ${powerSampledValueTemplate.measurand ?? OCPP16MeterValueMeasurand.ENERGY_ACTIVE_IMPORT_REGISTER}: Unknown ${self.chargingStation.getCurrentOutType()} currentOutType in template file ${self.chargingStation.stationTemplateFile}, cannot calculate ${powerSampledValueTemplate.measurand ?? OCPP16MeterValueMeasurand.ENERGY_ACTIVE_IMPORT_REGISTER} measurand value`;
+        OCPP16ServiceUtils.checkMeasurandPowerDivider(this.chargingStation, powerSampledValueTemplate.measurand);
+        const errMsg = `${this.chargingStation.logPrefix()} MeterValues measurand ${powerSampledValueTemplate.measurand ?? OCPP16MeterValueMeasurand.ENERGY_ACTIVE_IMPORT_REGISTER}: Unknown ${this.chargingStation.getCurrentOutType()} currentOutType in template file ${this.chargingStation.stationTemplateFile}, cannot calculate ${powerSampledValueTemplate.measurand ?? OCPP16MeterValueMeasurand.ENERGY_ACTIVE_IMPORT_REGISTER} measurand value`;
         const powerMeasurandValues = {} as MeasurandValues;
         const unitDivider = powerSampledValueTemplate?.unit === MeterValueUnit.KILO_WATT ? 1000 : 1;
-        const maxPower = Math.round(self.chargingStation.stationInfo.maxPower / self.chargingStation.stationInfo.powerDivider);
-        const maxPowerPerPhase = Math.round((self.chargingStation.stationInfo.maxPower / self.chargingStation.stationInfo.powerDivider) / self.chargingStation.getNumberOfPhases());
-        switch (self.chargingStation.getCurrentOutType()) {
-          case CurrentOutType.AC:
-            if (self.chargingStation.getNumberOfPhases() === 3) {
+        const maxPower = Math.round(this.chargingStation.stationInfo.maxPower / this.chargingStation.stationInfo.powerDivider);
+        const maxPowerPerPhase = Math.round((this.chargingStation.stationInfo.maxPower / this.chargingStation.stationInfo.powerDivider) / this.chargingStation.getNumberOfPhases());
+        switch (this.chargingStation.getCurrentOutType()) {
+          case CurrentType.AC:
+            if (this.chargingStation.getNumberOfPhases() === 3) {
               const defaultFluctuatedPowerPerPhase = powerSampledValueTemplate.value
-                && Utils.getRandomFloatFluctuatedRounded(parseInt(powerSampledValueTemplate.value) / self.chargingStation.getNumberOfPhases(), powerSampledValueTemplate.fluctuationPercent ?? Constants.DEFAULT_FLUCTUATION_PERCENT);
+                && Utils.getRandomFloatFluctuatedRounded(parseInt(powerSampledValueTemplate.value) / this.chargingStation.getNumberOfPhases(), powerSampledValueTemplate.fluctuationPercent ?? Constants.DEFAULT_FLUCTUATION_PERCENT);
               const phase1FluctuatedValue = powerPerPhaseSampledValueTemplates?.L1?.value
                 && Utils.getRandomFloatFluctuatedRounded(parseInt(powerPerPhaseSampledValueTemplates.L1.value), powerPerPhaseSampledValueTemplates.L1.fluctuationPercent ?? Constants.DEFAULT_FLUCTUATION_PERCENT);
               const phase2FluctuatedValue = powerPerPhaseSampledValueTemplates?.L2?.value
@@ -208,51 +218,51 @@ export default class OCPP16RequestService extends OCPPRequestService {
             }
             powerMeasurandValues.allPhases = Utils.roundTo(powerMeasurandValues.L1 + powerMeasurandValues.L2 + powerMeasurandValues.L3, 2);
             break;
-          case CurrentOutType.DC:
+          case CurrentType.DC:
             powerMeasurandValues.allPhases = powerSampledValueTemplate.value
               ? Utils.getRandomFloatFluctuatedRounded(parseInt(powerSampledValueTemplate.value), powerSampledValueTemplate.fluctuationPercent ?? Constants.DEFAULT_FLUCTUATION_PERCENT)
               : Utils.getRandomFloatRounded(maxPower / unitDivider);
             break;
           default:
             logger.error(errMsg);
-            throw Error(errMsg);
+            throw new OCPPError(ErrorType.INTERNAL_ERROR, errMsg, OCPP16RequestCommand.METER_VALUES);
         }
         meterValue.sampledValue.push(OCPP16ServiceUtils.buildSampledValue(powerSampledValueTemplate, powerMeasurandValues.allPhases));
         const sampledValuesIndex = meterValue.sampledValue.length - 1;
         const maxPowerRounded = Utils.roundTo(maxPower / unitDivider, 2);
         if (Utils.convertToFloat(meterValue.sampledValue[sampledValuesIndex].value) > maxPowerRounded || debug) {
-          logger.error(`${self.chargingStation.logPrefix()} MeterValues measurand ${meterValue.sampledValue[sampledValuesIndex].measurand ?? OCPP16MeterValueMeasurand.ENERGY_ACTIVE_IMPORT_REGISTER}: connectorId ${connectorId}, transaction ${connector.transactionId}, value: ${meterValue.sampledValue[sampledValuesIndex].value}/${maxPowerRounded}`);
+          logger.error(`${this.chargingStation.logPrefix()} MeterValues measurand ${meterValue.sampledValue[sampledValuesIndex].measurand ?? OCPP16MeterValueMeasurand.ENERGY_ACTIVE_IMPORT_REGISTER}: connectorId ${connectorId}, transaction ${connector.transactionId}, value: ${meterValue.sampledValue[sampledValuesIndex].value}/${maxPowerRounded}`);
         }
-        for (let phase = 1; self.chargingStation.getNumberOfPhases() === 3 && phase <= self.chargingStation.getNumberOfPhases(); phase++) {
+        for (let phase = 1; this.chargingStation.getNumberOfPhases() === 3 && phase <= this.chargingStation.getNumberOfPhases(); phase++) {
           const phaseValue = `L${phase}-N`;
           meterValue.sampledValue.push(OCPP16ServiceUtils.buildSampledValue(powerPerPhaseSampledValueTemplates[`L${phase}`] ?? powerSampledValueTemplate, powerMeasurandValues[`L${phase}`], null,
             phaseValue as OCPP16MeterValuePhase));
           const sampledValuesPerPhaseIndex = meterValue.sampledValue.length - 1;
           const maxPowerPerPhaseRounded = Utils.roundTo(maxPowerPerPhase / unitDivider, 2);
           if (Utils.convertToFloat(meterValue.sampledValue[sampledValuesPerPhaseIndex].value) > maxPowerPerPhaseRounded || debug) {
-            logger.error(`${self.chargingStation.logPrefix()} MeterValues measurand ${meterValue.sampledValue[sampledValuesPerPhaseIndex].measurand ?? OCPP16MeterValueMeasurand.ENERGY_ACTIVE_IMPORT_REGISTER}: phase ${meterValue.sampledValue[sampledValuesPerPhaseIndex].phase}, connectorId ${connectorId}, transaction ${connector.transactionId}, value: ${meterValue.sampledValue[sampledValuesPerPhaseIndex].value}/${maxPowerPerPhaseRounded}`);
+            logger.error(`${this.chargingStation.logPrefix()} MeterValues measurand ${meterValue.sampledValue[sampledValuesPerPhaseIndex].measurand ?? OCPP16MeterValueMeasurand.ENERGY_ACTIVE_IMPORT_REGISTER}: phase ${meterValue.sampledValue[sampledValuesPerPhaseIndex].phase}, connectorId ${connectorId}, transaction ${connector.transactionId}, value: ${meterValue.sampledValue[sampledValuesPerPhaseIndex].value}/${maxPowerPerPhaseRounded}`);
           }
         }
       }
       // Current.Import measurand
-      const currentSampledValueTemplate = self.chargingStation.getSampledValueTemplate(connectorId, OCPP16MeterValueMeasurand.CURRENT_IMPORT);
+      const currentSampledValueTemplate = this.chargingStation.getSampledValueTemplate(connectorId, OCPP16MeterValueMeasurand.CURRENT_IMPORT);
       let currentPerPhaseSampledValueTemplates: MeasurandPerPhaseSampledValueTemplates = {};
-      if (self.chargingStation.getNumberOfPhases() === 3) {
+      if (this.chargingStation.getNumberOfPhases() === 3) {
         currentPerPhaseSampledValueTemplates = {
-          L1: self.chargingStation.getSampledValueTemplate(connectorId, OCPP16MeterValueMeasurand.CURRENT_IMPORT, OCPP16MeterValuePhase.L1),
-          L2: self.chargingStation.getSampledValueTemplate(connectorId, OCPP16MeterValueMeasurand.CURRENT_IMPORT, OCPP16MeterValuePhase.L2),
-          L3: self.chargingStation.getSampledValueTemplate(connectorId, OCPP16MeterValueMeasurand.CURRENT_IMPORT, OCPP16MeterValuePhase.L3),
+          L1: this.chargingStation.getSampledValueTemplate(connectorId, OCPP16MeterValueMeasurand.CURRENT_IMPORT, OCPP16MeterValuePhase.L1),
+          L2: this.chargingStation.getSampledValueTemplate(connectorId, OCPP16MeterValueMeasurand.CURRENT_IMPORT, OCPP16MeterValuePhase.L2),
+          L3: this.chargingStation.getSampledValueTemplate(connectorId, OCPP16MeterValueMeasurand.CURRENT_IMPORT, OCPP16MeterValuePhase.L3),
         };
       }
       if (currentSampledValueTemplate) {
-        OCPP16ServiceUtils.checkMeasurandPowerDivider(self.chargingStation, currentSampledValueTemplate.measurand);
-        const errMsg = `${self.chargingStation.logPrefix()} MeterValues measurand ${currentSampledValueTemplate.measurand ?? OCPP16MeterValueMeasurand.ENERGY_ACTIVE_IMPORT_REGISTER}: Unknown ${self.chargingStation.getCurrentOutType()} currentOutType in template file ${self.chargingStation.stationTemplateFile}, cannot calculate ${currentSampledValueTemplate.measurand ?? OCPP16MeterValueMeasurand.ENERGY_ACTIVE_IMPORT_REGISTER} measurand value`;
+        OCPP16ServiceUtils.checkMeasurandPowerDivider(this.chargingStation, currentSampledValueTemplate.measurand);
+        const errMsg = `${this.chargingStation.logPrefix()} MeterValues measurand ${currentSampledValueTemplate.measurand ?? OCPP16MeterValueMeasurand.ENERGY_ACTIVE_IMPORT_REGISTER}: Unknown ${this.chargingStation.getCurrentOutType()} currentOutType in template file ${this.chargingStation.stationTemplateFile}, cannot calculate ${currentSampledValueTemplate.measurand ?? OCPP16MeterValueMeasurand.ENERGY_ACTIVE_IMPORT_REGISTER} measurand value`;
         const currentMeasurandValues: MeasurandValues = {} as MeasurandValues;
         let maxAmperage: number;
-        switch (self.chargingStation.getCurrentOutType()) {
-          case CurrentOutType.AC:
-            maxAmperage = ACElectricUtils.amperagePerPhaseFromPower(self.chargingStation.getNumberOfPhases(), self.chargingStation.stationInfo.maxPower / self.chargingStation.stationInfo.powerDivider, self.chargingStation.getVoltageOut());
-            if (self.chargingStation.getNumberOfPhases() === 3) {
+        switch (this.chargingStation.getCurrentOutType()) {
+          case CurrentType.AC:
+            maxAmperage = ACElectricUtils.amperagePerPhaseFromPower(this.chargingStation.getNumberOfPhases(), this.chargingStation.stationInfo.maxPower / this.chargingStation.stationInfo.powerDivider, this.chargingStation.getVoltageOut());
+            if (this.chargingStation.getNumberOfPhases() === 3) {
               const defaultFluctuatedAmperagePerPhase = currentSampledValueTemplate.value
                 && Utils.getRandomFloatFluctuatedRounded(parseInt(currentSampledValueTemplate.value), currentSampledValueTemplate.fluctuationPercent ?? Constants.DEFAULT_FLUCTUATION_PERCENT);
               const phase1FluctuatedValue = currentPerPhaseSampledValueTemplates?.L1?.value
@@ -271,91 +281,122 @@ export default class OCPP16RequestService extends OCPPRequestService {
               currentMeasurandValues.L2 = 0;
               currentMeasurandValues.L3 = 0;
             }
-            currentMeasurandValues.allPhases = Utils.roundTo((currentMeasurandValues.L1 + currentMeasurandValues.L2 + currentMeasurandValues.L3) / self.chargingStation.getNumberOfPhases(), 2);
+            currentMeasurandValues.allPhases = Utils.roundTo((currentMeasurandValues.L1 + currentMeasurandValues.L2 + currentMeasurandValues.L3) / this.chargingStation.getNumberOfPhases(), 2);
             break;
-          case CurrentOutType.DC:
-            maxAmperage = DCElectricUtils.amperage(self.chargingStation.stationInfo.maxPower / self.chargingStation.stationInfo.powerDivider, self.chargingStation.getVoltageOut());
+          case CurrentType.DC:
+            maxAmperage = DCElectricUtils.amperage(this.chargingStation.stationInfo.maxPower / this.chargingStation.stationInfo.powerDivider, this.chargingStation.getVoltageOut());
             currentMeasurandValues.allPhases = currentSampledValueTemplate.value
               ? Utils.getRandomFloatFluctuatedRounded(parseInt(currentSampledValueTemplate.value), currentSampledValueTemplate.fluctuationPercent ?? Constants.DEFAULT_FLUCTUATION_PERCENT)
               : Utils.getRandomFloatRounded(maxAmperage);
             break;
           default:
             logger.error(errMsg);
-            throw Error(errMsg);
+            throw new OCPPError(ErrorType.INTERNAL_ERROR, errMsg, OCPP16RequestCommand.METER_VALUES);
         }
         meterValue.sampledValue.push(OCPP16ServiceUtils.buildSampledValue(currentSampledValueTemplate, currentMeasurandValues.allPhases));
         const sampledValuesIndex = meterValue.sampledValue.length - 1;
         if (Utils.convertToFloat(meterValue.sampledValue[sampledValuesIndex].value) > maxAmperage || debug) {
-          logger.error(`${self.chargingStation.logPrefix()} MeterValues measurand ${meterValue.sampledValue[sampledValuesIndex].measurand ?? OCPP16MeterValueMeasurand.ENERGY_ACTIVE_IMPORT_REGISTER}: connectorId ${connectorId}, transaction ${connector.transactionId}, value: ${meterValue.sampledValue[sampledValuesIndex].value}/${maxAmperage}`);
+          logger.error(`${this.chargingStation.logPrefix()} MeterValues measurand ${meterValue.sampledValue[sampledValuesIndex].measurand ?? OCPP16MeterValueMeasurand.ENERGY_ACTIVE_IMPORT_REGISTER}: connectorId ${connectorId}, transaction ${connector.transactionId}, value: ${meterValue.sampledValue[sampledValuesIndex].value}/${maxAmperage}`);
         }
-        for (let phase = 1; self.chargingStation.getNumberOfPhases() === 3 && phase <= self.chargingStation.getNumberOfPhases(); phase++) {
+        for (let phase = 1; this.chargingStation.getNumberOfPhases() === 3 && phase <= this.chargingStation.getNumberOfPhases(); phase++) {
           const phaseValue = `L${phase}`;
           meterValue.sampledValue.push(OCPP16ServiceUtils.buildSampledValue(currentPerPhaseSampledValueTemplates[phaseValue] ?? currentSampledValueTemplate,
             currentMeasurandValues[phaseValue], null, phaseValue as OCPP16MeterValuePhase));
           const sampledValuesPerPhaseIndex = meterValue.sampledValue.length - 1;
           if (Utils.convertToFloat(meterValue.sampledValue[sampledValuesPerPhaseIndex].value) > maxAmperage || debug) {
-            logger.error(`${self.chargingStation.logPrefix()} MeterValues measurand ${meterValue.sampledValue[sampledValuesPerPhaseIndex].measurand ?? OCPP16MeterValueMeasurand.ENERGY_ACTIVE_IMPORT_REGISTER}: phase ${meterValue.sampledValue[sampledValuesPerPhaseIndex].phase}, connectorId ${connectorId}, transaction ${connector.transactionId}, value: ${meterValue.sampledValue[sampledValuesPerPhaseIndex].value}/${maxAmperage}`);
+            logger.error(`${this.chargingStation.logPrefix()} MeterValues measurand ${meterValue.sampledValue[sampledValuesPerPhaseIndex].measurand ?? OCPP16MeterValueMeasurand.ENERGY_ACTIVE_IMPORT_REGISTER}: phase ${meterValue.sampledValue[sampledValuesPerPhaseIndex].phase}, connectorId ${connectorId}, transaction ${connector.transactionId}, value: ${meterValue.sampledValue[sampledValuesPerPhaseIndex].value}/${maxAmperage}`);
           }
         }
       }
       // Energy.Active.Import.Register measurand (default)
-      const energySampledValueTemplate = self.chargingStation.getSampledValueTemplate(connectorId);
+      const energySampledValueTemplate = this.chargingStation.getSampledValueTemplate(connectorId);
       if (energySampledValueTemplate) {
-        OCPP16ServiceUtils.checkMeasurandPowerDivider(self.chargingStation, energySampledValueTemplate.measurand);
+        OCPP16ServiceUtils.checkMeasurandPowerDivider(this.chargingStation, energySampledValueTemplate.measurand);
         const unitDivider = energySampledValueTemplate?.unit === MeterValueUnit.KILO_WATT_HOUR ? 1000 : 1;
-        const energyMeasurandValue = energySampledValueTemplate.value
+        const maxEnergyRounded = Utils.roundTo(((this.chargingStation.stationInfo.maxPower / this.chargingStation.stationInfo.powerDivider) * interval) / (3600 * 1000), 2);
+        const energyValueRounded = energySampledValueTemplate.value
           // Cumulate the fluctuated value around the static one
           ? Utils.getRandomFloatFluctuatedRounded(parseInt(energySampledValueTemplate.value), energySampledValueTemplate.fluctuationPercent ?? Constants.DEFAULT_FLUCTUATION_PERCENT)
-          : Utils.getRandomInt(self.chargingStation.stationInfo.maxPower / (self.chargingStation.stationInfo.powerDivider * 3600000) * interval);
+          : Utils.getRandomFloatRounded(maxEnergyRounded);
         // Persist previous value on connector
         if (connector && !Utils.isNullOrUndefined(connector.energyActiveImportRegisterValue) && connector.energyActiveImportRegisterValue >= 0 &&
-            !Utils.isNullOrUndefined(connector.transactionEnergyActiveImportRegisterValue) && connector.transactionEnergyActiveImportRegisterValue >= 0) {
-          connector.energyActiveImportRegisterValue += energyMeasurandValue;
-          connector.transactionEnergyActiveImportRegisterValue += energyMeasurandValue;
+          !Utils.isNullOrUndefined(connector.transactionEnergyActiveImportRegisterValue) && connector.transactionEnergyActiveImportRegisterValue >= 0) {
+          connector.energyActiveImportRegisterValue += energyValueRounded;
+          connector.transactionEnergyActiveImportRegisterValue += energyValueRounded;
         } else {
           connector.energyActiveImportRegisterValue = 0;
           connector.transactionEnergyActiveImportRegisterValue = 0;
         }
         meterValue.sampledValue.push(OCPP16ServiceUtils.buildSampledValue(energySampledValueTemplate,
-          Utils.roundTo(self.chargingStation.getEnergyActiveImportRegisterByTransactionId(transactionId) / unitDivider, 4)));
+          Utils.roundTo(this.chargingStation.getEnergyActiveImportRegisterByTransactionId(transactionId) / unitDivider, 2)));
         const sampledValuesIndex = meterValue.sampledValue.length - 1;
-        const maxEnergy = Math.round(self.chargingStation.stationInfo.maxPower * 3600 / (self.chargingStation.stationInfo.powerDivider * interval));
-        const maxEnergyRounded = Utils.roundTo(maxEnergy / unitDivider, 4);
-        if (Utils.convertToFloat(meterValue.sampledValue[sampledValuesIndex].value) > maxEnergyRounded || debug) {
-          logger.error(`${self.chargingStation.logPrefix()} MeterValues measurand ${meterValue.sampledValue[sampledValuesIndex].measurand ?? OCPP16MeterValueMeasurand.ENERGY_ACTIVE_IMPORT_REGISTER}: connectorId ${connectorId}, transaction ${connector.transactionId}, value: ${meterValue.sampledValue[sampledValuesIndex].value}/${maxEnergyRounded}`);
+        if (energyValueRounded > maxEnergyRounded || debug) {
+          logger.error(`${this.chargingStation.logPrefix()} MeterValues measurand ${meterValue.sampledValue[sampledValuesIndex].measurand ?? OCPP16MeterValueMeasurand.ENERGY_ACTIVE_IMPORT_REGISTER}: connectorId ${connectorId}, transaction ${connector.transactionId}, value: ${energyValueRounded}/${maxEnergyRounded}, duration: ${Utils.roundTo(interval / (3600 * 1000), 4)}h`);
         }
       }
       const payload: MeterValuesRequest = {
         connectorId,
         transactionId,
-        meterValue,
+        meterValue: [meterValue],
       };
-      await self.sendMessage(Utils.generateUUID(), payload, MessageType.CALL_MESSAGE, OCPP16RequestCommand.METER_VALUES);
+      await this.sendMessage(Utils.generateUUID(), payload, MessageType.CALL_MESSAGE, OCPP16RequestCommand.METER_VALUES);
     } catch (error) {
-      self.handleRequestError(OCPP16RequestCommand.METER_VALUES, error);
+      this.handleRequestError(OCPP16RequestCommand.METER_VALUES, error as Error);
     }
   }
 
   public async sendTransactionBeginMeterValues(connectorId: number, transactionId: number, beginMeterValue: OCPP16MeterValue): Promise<void> {
-    const payload: MeterValuesRequest = {
-      connectorId,
-      transactionId,
-      meterValue: beginMeterValue,
-    };
-    await this.sendMessage(Utils.generateUUID(), payload, MessageType.CALL_MESSAGE, OCPP16RequestCommand.METER_VALUES);
+    try {
+      const payload: MeterValuesRequest = {
+        connectorId,
+        transactionId,
+        meterValue: [beginMeterValue],
+      };
+      await this.sendMessage(Utils.generateUUID(), payload, MessageType.CALL_MESSAGE, OCPP16RequestCommand.METER_VALUES);
+    } catch (error) {
+      this.handleRequestError(OCPP16RequestCommand.METER_VALUES, error as Error);
+    }
   }
 
   public async sendTransactionEndMeterValues(connectorId: number, transactionId: number, endMeterValue: OCPP16MeterValue): Promise<void> {
-    const payload: MeterValuesRequest = {
-      connectorId,
-      transactionId,
-      meterValue: endMeterValue,
-    };
-    await this.sendMessage(Utils.generateUUID(), payload, MessageType.CALL_MESSAGE, OCPP16RequestCommand.METER_VALUES);
+    try {
+      const payload: MeterValuesRequest = {
+        connectorId,
+        transactionId,
+        meterValue: [endMeterValue],
+      };
+      await this.sendMessage(Utils.generateUUID(), payload, MessageType.CALL_MESSAGE, OCPP16RequestCommand.METER_VALUES);
+    } catch (error) {
+      this.handleRequestError(OCPP16RequestCommand.METER_VALUES, error as Error);
+    }
   }
 
-  public async sendError(messageId: string, error: OCPPError, commandName: OCPP16RequestCommand | OCPP16IncomingRequestCommand): Promise<unknown> {
-    // Send error
-    return this.sendMessage(messageId, error, MessageType.CALL_ERROR_MESSAGE, commandName);
+  public async sendDiagnosticsStatusNotification(diagnosticsStatus: OCPP16DiagnosticsStatus): Promise<void> {
+    try {
+      const payload: DiagnosticsStatusNotificationRequest = {
+        status: diagnosticsStatus
+      };
+      await this.sendMessage(Utils.generateUUID(), payload, MessageType.CALL_MESSAGE, OCPP16RequestCommand.DIAGNOSTICS_STATUS_NOTIFICATION);
+    } catch (error) {
+      this.handleRequestError(OCPP16RequestCommand.METER_VALUES, error as Error);
+    }
+  }
+
+  public async sendResult(messageId: string, resultMessageData: JsonType, commandName: OCPP16RequestCommand | OCPP16IncomingRequestCommand): Promise<JsonType> {
+    try {
+      // Send error
+      return await this.sendMessage(messageId, resultMessageData, MessageType.CALL_RESULT_MESSAGE, commandName) as JsonType;
+    } catch (error) {
+      this.handleRequestError(commandName as OCPP16RequestCommand, error as Error);
+    }
+  }
+
+  public async sendError(messageId: string, ocppError: OCPPError, commandName: OCPP16RequestCommand | OCPP16IncomingRequestCommand): Promise<JsonType> {
+    try {
+      // Send error
+      return await this.sendMessage(messageId, ocppError, MessageType.CALL_ERROR_MESSAGE, commandName) as JsonType;
+    } catch (error) {
+      this.handleRequestError(commandName as OCPP16RequestCommand, error as Error);
+    }
   }
 }