Code cleanups
[e-mobility-charging-stations-simulator.git] / src / charging-station / ocpp / 1.6 / OCPP16RequestService.ts
index 4e82845307b2dc0ddc6ae77e27d12512911026cb..8e5c3ffacdc0c38716142e7bc1ca309dd5ec7000 100644 (file)
@@ -2,8 +2,9 @@ import { AuthorizeRequest, OCPP16AuthorizeResponse, OCPP16StartTransactionRespon
 import { HeartbeatRequest, OCPP16BootNotificationRequest, OCPP16IncomingRequestCommand, OCPP16RequestCommand, StatusNotificationRequest } from '../../../types/ocpp/1.6/Requests';
 import { MeterValue, MeterValueLocation, MeterValuePhase, MeterValueUnit, MeterValuesRequest, OCPP16MeterValueMeasurand, OCPP16SampledValue } from '../../../types/ocpp/1.6/MeterValues';
 
+import { ACElectricUtils } from '../../../utils/ElectricUtils';
 import Constants from '../../../utils/Constants';
-import ElectricUtils from '../../../utils/ElectricUtils';
+import { CurrentOutType } from '../../../types/ChargingStationTemplate';
 import MeasurandValues from '../../../types/MeasurandValues';
 import { MessageType } from '../../../types/ocpp/MessageType';
 import { OCPP16BootNotificationResponse } from '../../../types/ocpp/1.6/Responses';
@@ -12,7 +13,6 @@ import { OCPP16ChargePointStatus } from '../../../types/ocpp/1.6/ChargePointStat
 import { OCPP16StandardParametersKey } from '../../../types/ocpp/1.6/Configuration';
 import OCPPError from '../../OcppError';
 import OCPPRequestService from '../OCPPRequestService';
-import { PowerOutType } from '../../../types/ChargingStationTemplate';
 import Utils from '../../../utils/Utils';
 import logger from '../../../utils/Logger';
 
@@ -62,7 +62,7 @@ export default class OCPP16RequestService extends OCPPRequestService {
   public async sendAuthorize(idTag?: string): Promise<OCPP16AuthorizeResponse> {
     try {
       const payload: AuthorizeRequest = {
-        ...!Utils.isUndefined(idTag) ? { idTag } : { idTag: Constants.TRANSACTION_DEFAULT_TAGID },
+        ...!Utils.isUndefined(idTag) ? { idTag } : { idTag: Constants.TRANSACTION_DEFAULT_IDTAG },
       };
       return await this.sendMessage(Utils.generateUUID(), payload, MessageType.CALL_MESSAGE, OCPP16RequestCommand.AUTHORIZE) as OCPP16AuthorizeResponse;
     } catch (error) {
@@ -74,7 +74,7 @@ export default class OCPP16RequestService extends OCPPRequestService {
     try {
       const payload: StartTransactionRequest = {
         connectorId,
-        ...!Utils.isUndefined(idTag) ? { idTag } : { idTag: Constants.TRANSACTION_DEFAULT_TAGID },
+        ...!Utils.isUndefined(idTag) ? { idTag } : { idTag: Constants.TRANSACTION_DEFAULT_IDTAG },
         meterStart: 0,
         timestamp: new Date().toISOString(),
       };
@@ -161,12 +161,12 @@ export default class OCPP16RequestService extends OCPPRequestService {
             logger.error(errMsg);
             throw Error(errMsg);
           }
-          const errMsg = `${self.chargingStation.logPrefix()} MeterValues measurand ${meterValuesTemplate[index].measurand ? meterValuesTemplate[index].measurand : OCPP16MeterValueMeasurand.ENERGY_ACTIVE_IMPORT_REGISTER}: Unknown ${self.chargingStation.getPowerOutType()} powerOutType in template file ${self.chargingStation.stationTemplateFile}, cannot calculate ${meterValuesTemplate[index].measurand ? meterValuesTemplate[index].measurand : OCPP16MeterValueMeasurand.ENERGY_ACTIVE_IMPORT_REGISTER} measurand value`;
+          const errMsg = `${self.chargingStation.logPrefix()} MeterValues measurand ${meterValuesTemplate[index].measurand ? meterValuesTemplate[index].measurand : OCPP16MeterValueMeasurand.ENERGY_ACTIVE_IMPORT_REGISTER}: Unknown ${self.chargingStation.getCurrentOutType()} currentOutType in template file ${self.chargingStation.stationTemplateFile}, cannot calculate ${meterValuesTemplate[index].measurand ? meterValuesTemplate[index].measurand : OCPP16MeterValueMeasurand.ENERGY_ACTIVE_IMPORT_REGISTER} measurand value`;
           const powerMeasurandValues = {} as MeasurandValues;
           const maxPower = Math.round(self.chargingStation.stationInfo.maxPower / self.chargingStation.stationInfo.powerDivider);
           const maxPowerPerPhase = Math.round((self.chargingStation.stationInfo.maxPower / self.chargingStation.stationInfo.powerDivider) / self.chargingStation.getNumberOfPhases());
-          switch (self.chargingStation.getPowerOutType()) {
-            case PowerOutType.AC:
+          switch (self.chargingStation.getCurrentOutType()) {
+            case CurrentOutType.AC:
               if (Utils.isUndefined(meterValuesTemplate[index].value)) {
                 powerMeasurandValues.L1 = Utils.getRandomFloatRounded(maxPowerPerPhase);
                 powerMeasurandValues.L2 = 0;
@@ -178,7 +178,7 @@ export default class OCPP16RequestService extends OCPPRequestService {
                 powerMeasurandValues.allPhases = Utils.roundTo(powerMeasurandValues.L1 + powerMeasurandValues.L2 + powerMeasurandValues.L3, 2);
               }
               break;
-            case PowerOutType.DC:
+            case CurrentOutType.DC:
               if (Utils.isUndefined(meterValuesTemplate[index].value)) {
                 powerMeasurandValues.allPhases = Utils.getRandomFloatRounded(maxPower);
               }
@@ -221,12 +221,12 @@ export default class OCPP16RequestService extends OCPPRequestService {
             logger.error(errMsg);
             throw Error(errMsg);
           }
-          const errMsg = `${self.chargingStation.logPrefix()} MeterValues measurand ${meterValuesTemplate[index].measurand ? meterValuesTemplate[index].measurand : OCPP16MeterValueMeasurand.ENERGY_ACTIVE_IMPORT_REGISTER}: Unknown ${self.chargingStation.getPowerOutType()} powerOutType in template file ${self.chargingStation.stationTemplateFile}, cannot calculate ${meterValuesTemplate[index].measurand ? meterValuesTemplate[index].measurand : OCPP16MeterValueMeasurand.ENERGY_ACTIVE_IMPORT_REGISTER} measurand value`;
+          const errMsg = `${self.chargingStation.logPrefix()} MeterValues measurand ${meterValuesTemplate[index].measurand ? meterValuesTemplate[index].measurand : OCPP16MeterValueMeasurand.ENERGY_ACTIVE_IMPORT_REGISTER}: Unknown ${self.chargingStation.getCurrentOutType()} currentOutType in template file ${self.chargingStation.stationTemplateFile}, cannot calculate ${meterValuesTemplate[index].measurand ? meterValuesTemplate[index].measurand : OCPP16MeterValueMeasurand.ENERGY_ACTIVE_IMPORT_REGISTER} measurand value`;
           const currentMeasurandValues: MeasurandValues = {} as MeasurandValues;
           let maxAmperage: number;
-          switch (self.chargingStation.getPowerOutType()) {
-            case PowerOutType.AC:
-              maxAmperage = ElectricUtils.ampPerPhaseFromPower(self.chargingStation.getNumberOfPhases(), self.chargingStation.stationInfo.maxPower / self.chargingStation.stationInfo.powerDivider, self.chargingStation.getVoltageOut());
+          switch (self.chargingStation.getCurrentOutType()) {
+            case CurrentOutType.AC:
+              maxAmperage = ACElectricUtils.amperagePerPhaseFromPower(self.chargingStation.getNumberOfPhases(), self.chargingStation.stationInfo.maxPower / self.chargingStation.stationInfo.powerDivider, self.chargingStation.getVoltageOut());
               if (Utils.isUndefined(meterValuesTemplate[index].value)) {
                 currentMeasurandValues.L1 = Utils.getRandomFloatRounded(maxAmperage);
                 currentMeasurandValues.L2 = 0;
@@ -238,8 +238,8 @@ export default class OCPP16RequestService extends OCPPRequestService {
                 currentMeasurandValues.allPhases = Utils.roundTo((currentMeasurandValues.L1 + currentMeasurandValues.L2 + currentMeasurandValues.L3) / self.chargingStation.getNumberOfPhases(), 2);
               }
               break;
-            case PowerOutType.DC:
-              maxAmperage = ElectricUtils.ampTotalFromPower(self.chargingStation.stationInfo.maxPower / self.chargingStation.stationInfo.powerDivider, self.chargingStation.getVoltageOut());
+            case CurrentOutType.DC:
+              maxAmperage = ACElectricUtils.amperageTotalFromPower(self.chargingStation.stationInfo.maxPower / self.chargingStation.stationInfo.powerDivider, self.chargingStation.getVoltageOut());
               if (Utils.isUndefined(meterValuesTemplate[index].value)) {
                 currentMeasurandValues.allPhases = Utils.getRandomFloatRounded(maxAmperage);
               }
@@ -314,9 +314,9 @@ export default class OCPP16RequestService extends OCPPRequestService {
         transactionId,
         meterValue,
       };
-      await self.sendMessage(Utils.generateUUID(), payload, MessageType.CALL_MESSAGE, OCPP16RequestCommand.METERVALUES);
+      await self.sendMessage(Utils.generateUUID(), payload, MessageType.CALL_MESSAGE, OCPP16RequestCommand.METER_VALUES);
     } catch (error) {
-      self.handleRequestError(OCPP16RequestCommand.METERVALUES, error);
+      self.handleRequestError(OCPP16RequestCommand.METER_VALUES, error);
     }
   }