perf: optimize min/max implementation
[e-mobility-charging-stations-simulator.git] / src / charging-station / ocpp / OCPPServiceUtils.ts
index 5dbe2fb4953d66ab535141e0ac4de12362f2af74..7c459809f45f2df877fcb69a2db54953c5e4a8a6 100644 (file)
@@ -3,14 +3,19 @@ import { dirname, join } from 'node:path';
 import { fileURLToPath } from 'node:url';
 
 import type { DefinedError, ErrorObject, JSONSchemaType } from 'ajv';
+import { isDate } from 'date-fns';
 
 import { OCPP16Constants } from './1.6/OCPP16Constants';
 import { OCPP20Constants } from './2.0/OCPP20Constants';
 import { OCPPConstants } from './OCPPConstants';
-import { type ChargingStation, getConfigurationKey } from '../../charging-station';
+import { type ChargingStation, getConfigurationKey, getIdTagsFile } from '../../charging-station';
 import { BaseError } from '../../exception';
 import {
+  AuthorizationStatus,
+  type AuthorizeRequest,
+  type AuthorizeResponse,
   ChargePointErrorCode,
+  type ConnectorStatus,
   type ConnectorStatusEnum,
   ErrorType,
   FileType,
@@ -35,6 +40,7 @@ import {
   isNotEmptyString,
   logPrefix,
   logger,
+  min,
 } from '../../utils';
 
 export class OCPPServiceUtils {
@@ -83,9 +89,9 @@ export class OCPPServiceUtils {
       return true;
     } else if (
       isRequestCommand === true &&
-      chargingStation.stationInfo?.commandsSupport?.outgoingCommands
+      chargingStation.stationInfo?.commandsSupport?.outgoingCommands?.[command]
     ) {
-      return chargingStation.stationInfo?.commandsSupport?.outgoingCommands[command] ?? false;
+      return chargingStation.stationInfo?.commandsSupport?.outgoingCommands[command];
     }
     logger.error(`${chargingStation.logPrefix()} Unknown outgoing OCPP command '${command}'`);
     return false;
@@ -104,9 +110,9 @@ export class OCPPServiceUtils {
       return true;
     } else if (
       isIncomingRequestCommand === true &&
-      chargingStation.stationInfo?.commandsSupport?.incomingCommands
+      chargingStation.stationInfo?.commandsSupport?.incomingCommands?.[command]
     ) {
-      return chargingStation.stationInfo?.commandsSupport?.incomingCommands[command] ?? false;
+      return chargingStation.stationInfo?.commandsSupport?.incomingCommands[command];
     }
     logger.error(`${chargingStation.logPrefix()} Unknown incoming OCPP command '${command}'`);
     return false;
@@ -119,8 +125,11 @@ export class OCPPServiceUtils {
     const isMessageTrigger = Object.values(MessageTrigger).includes(messageTrigger);
     if (isMessageTrigger === true && !chargingStation.stationInfo?.messageTriggerSupport) {
       return true;
-    } else if (isMessageTrigger === true && chargingStation.stationInfo?.messageTriggerSupport) {
-      return chargingStation.stationInfo?.messageTriggerSupport[messageTrigger] ?? false;
+    } else if (
+      isMessageTrigger === true &&
+      chargingStation.stationInfo?.messageTriggerSupport?.[messageTrigger]
+    ) {
+      return chargingStation.stationInfo?.messageTriggerSupport[messageTrigger];
     }
     logger.error(
       `${chargingStation.logPrefix()} Unknown incoming OCPP message trigger '${messageTrigger}'`,
@@ -145,7 +154,7 @@ export class OCPPServiceUtils {
   public static convertDateToISOString<T extends JsonType>(obj: T): void {
     for (const key in obj) {
       // eslint-disable-next-line @typescript-eslint/no-unnecessary-type-assertion
-      if (obj![key] instanceof Date) {
+      if (isDate(obj![key])) {
         // eslint-disable-next-line @typescript-eslint/no-unnecessary-type-assertion
         (obj![key] as string) = (obj![key] as Date).toISOString();
         // eslint-disable-next-line @typescript-eslint/no-unnecessary-type-assertion
@@ -217,6 +226,30 @@ export class OCPPServiceUtils {
     chargingStation.getConnectorStatus(connectorId)!.status = status;
   }
 
+  public static async isIdTagAuthorized(
+    chargingStation: ChargingStation,
+    connectorId: number,
+    idTag: string,
+  ): Promise<boolean> {
+    if (!chargingStation.getLocalAuthListEnabled() && !chargingStation.getRemoteAuthorization()) {
+      logger.warn(
+        `${chargingStation.logPrefix()} The charging station expects to authorize RFID tags but nor local authorization nor remote authorization are enabled. Misbehavior may occur`,
+      );
+    }
+    if (
+      chargingStation.getLocalAuthListEnabled() === true &&
+      OCPPServiceUtils.isIdTagLocalAuthorized(chargingStation, idTag)
+    ) {
+      const connectorStatus: ConnectorStatus = chargingStation.getConnectorStatus(connectorId)!;
+      connectorStatus.localAuthorizeIdTag = idTag;
+      connectorStatus.idTagLocalAuthorized = true;
+      return true;
+    } else if (chargingStation.getRemoteAuthorization()) {
+      return await OCPPServiceUtils.isIdTagRemoteAuthorized(chargingStation, connectorId, idTag);
+    }
+    return false;
+  }
+
   protected static checkConnectorStatusTransition(
     chargingStation: ChargingStation,
     connectorId: number,
@@ -348,7 +381,7 @@ export class OCPPServiceUtils {
         return sampledValueTemplates[index];
       } else if (
         !phase &&
-        !sampledValueTemplates[index].phase &&
+        !sampledValueTemplates[index]?.phase &&
         sampledValueTemplates[index]?.measurand === measurand &&
         getConfigurationKey(
           chargingStation,
@@ -358,8 +391,8 @@ export class OCPPServiceUtils {
         return sampledValueTemplates[index];
       } else if (
         measurand === MeterValueMeasurand.ENERGY_ACTIVE_IMPORT_REGISTER &&
-        (!sampledValueTemplates[index].measurand ||
-          sampledValueTemplates[index].measurand === measurand)
+        (!sampledValueTemplates[index]?.measurand ||
+          sampledValueTemplates[index]?.measurand === measurand)
       ) {
         return sampledValueTemplates[index];
       }
@@ -377,10 +410,7 @@ export class OCPPServiceUtils {
   protected static getLimitFromSampledValueTemplateCustomValue(
     value: string,
     limit: number,
-    options: { limitationEnabled?: boolean; unitMultiplier?: number } = {
-      limitationEnabled: true,
-      unitMultiplier: 1,
-    },
+    options?: { limitationEnabled?: boolean; unitMultiplier?: number },
   ): number {
     options = {
       ...{
@@ -392,10 +422,39 @@ export class OCPPServiceUtils {
     const parsedInt = parseInt(value);
     const numberValue = isNaN(parsedInt) ? Infinity : parsedInt;
     return options?.limitationEnabled
-      ? Math.min(numberValue * options.unitMultiplier!, limit)
+      ? min(numberValue * options.unitMultiplier!, limit)
       : numberValue * options.unitMultiplier!;
   }
 
+  private static isIdTagLocalAuthorized(chargingStation: ChargingStation, idTag: string): boolean {
+    return (
+      chargingStation.hasIdTags() === true &&
+      isNotEmptyString(
+        chargingStation.idTagsCache
+          .getIdTags(getIdTagsFile(chargingStation.stationInfo)!)
+          ?.find((tag) => tag === idTag),
+      )
+    );
+  }
+
+  private static async isIdTagRemoteAuthorized(
+    chargingStation: ChargingStation,
+    connectorId: number,
+    idTag: string,
+  ): Promise<boolean> {
+    chargingStation.getConnectorStatus(connectorId)!.authorizeIdTag = idTag;
+    return (
+      (
+        await chargingStation.ocppRequestService.requestHandler<
+          AuthorizeRequest,
+          AuthorizeResponse
+        >(chargingStation, RequestCommand.AUTHORIZE, {
+          idTag,
+        })
+      )?.idTagInfo?.status === AuthorizationStatus.ACCEPTED
+    );
+  }
+
   private static logPrefix = (
     ocppVersion: OCPPVersion,
     moduleName?: string,