fix: ensure event listeners are always removed at simulator stop
[e-mobility-charging-stations-simulator.git] / src / charging-station / ocpp / OCPPServiceUtils.ts
index 3a1423c4679ce0561b46df3f30d58dc5da0f7189..d9d712981c816790cb4e2b6f1c09fa6cd10e7dac 100644 (file)
@@ -41,6 +41,7 @@ import {
   isNotEmptyString,
   logPrefix,
   logger,
+  max,
   min,
 } from '../../utils';
 
@@ -417,24 +418,27 @@ export class OCPPServiceUtils {
   }
 
   protected static getLimitFromSampledValueTemplateCustomValue(
-    value: string,
-    limit: number,
-    options?: { limitationEnabled?: boolean; unitMultiplier?: number; defaultValue?: number },
+    value: string | undefined,
+    maxLimit: number,
+    minLimit: number,
+    options?: { limitationEnabled?: boolean; fallbackValue?: number; unitMultiplier?: number },
   ): number {
     options = {
       ...{
-        limitationEnabled: true,
+        limitationEnabled: false,
         unitMultiplier: 1,
-        defaultValue: 0,
+        fallbackValue: 0,
       },
       ...options,
     };
-    const parsedValue = parseInt(value);
+    const parsedValue = parseInt(value ?? '');
     if (options?.limitationEnabled) {
-      const numberValue = !isNaN(parsedValue) ? parsedValue : Infinity;
-      return min(numberValue * options.unitMultiplier!, limit);
+      return max(
+        min((!isNaN(parsedValue) ? parsedValue : Infinity) * options.unitMultiplier!, maxLimit),
+        minLimit,
+      );
     }
-    return (!isNaN(parsedValue) ? parsedValue : options.defaultValue!) * options.unitMultiplier!;
+    return (!isNaN(parsedValue) ? parsedValue : options.fallbackValue!) * options.unitMultiplier!;
   }
 
   private static isIdTagLocalAuthorized(chargingStation: ChargingStation, idTag: string): boolean {