#include "../implementations/ANCommandHandler.h"
#include "../implementations/CECCommandHandler.h"
#include "../implementations/SLCommandHandler.h"
+#include "../implementations/VLCommandHandler.h"
#include "../platform/timeutils.h"
using namespace CEC;
CCECBusDevice::CCECBusDevice(CCECProcessor *processor, cec_logical_address iLogicalAddress, uint16_t iPhysicalAddress) :
m_iPhysicalAddress(iPhysicalAddress),
m_iLogicalAddress(iLogicalAddress),
+ m_powerStatus(CEC_POWER_STATUS_UNKNOWN),
m_processor(processor),
- m_iVendorId(0),
+ m_bMenuActive(true),
m_iVendorClass(CEC_VENDOR_UNKNOWN),
- m_iLastActive(0)
+ m_iLastActive(0),
+ m_cecVersion(CEC_VERSION_1_3A)
{
m_handler = new CCECCommandHandler(this);
+
+ for (unsigned int iPtr = 0; iPtr < 4; iPtr++)
+ m_menuLanguage.language[iPtr] = '?';
+ m_menuLanguage.language[3] = 0;
+ m_menuLanguage.device = iLogicalAddress;
+
+ m_vendor.vendor = CEC_VENDOR_UNKNOWN;
+ m_type = CEC_DEVICE_TYPE_RESERVED;
+ m_strDeviceName = "Unknown";
}
CCECBusDevice::~CCECBusDevice(void)
{
+ m_condition.Broadcast();
delete m_handler;
}
+void CCECBusDevice::AddLog(cec_log_level level, const CStdString &strMessage)
+{
+ m_processor->AddLog(level, strMessage);
+}
+
+bool CCECBusDevice::HandleCommand(const cec_command &command)
+{
+ CLockObject lock(&m_mutex);
+ m_iLastActive = GetTimeMs();
+ m_handler->HandleCommand(command);
+ m_condition.Signal();
+ return true;
+}
+
+void CCECBusDevice::PollVendorId(void)
+{
+ CLockObject lock(&m_mutex);
+ if (m_iLastActive > 0 && m_iLogicalAddress != CECDEVICE_BROADCAST &&
+ m_vendor.vendor == CEC_VENDOR_UNKNOWN &&
+ GetTimeMs() - m_iLastActive > 5000)
+ {
+ m_iLastActive = GetTimeMs();
+
+ cec_command command;
+ cec_command::format(command, GetMyLogicalAddress(), m_iLogicalAddress, CEC_OPCODE_GIVE_DEVICE_VENDOR_ID);
+ if (m_processor->Transmit(command))
+ m_condition.Wait(&m_mutex, 1000);
+ }
+}
+
+bool CCECBusDevice::PowerOn(void)
+{
+ CStdString strLog;
+ strLog.Format("<< powering on device with logical address %d", (int8_t)m_iLogicalAddress);
+ AddLog(CEC_LOG_DEBUG, strLog.c_str());
+
+ cec_command command;
+ cec_command::format(command, GetMyLogicalAddress(), m_iLogicalAddress, CEC_OPCODE_IMAGE_VIEW_ON);
+
+ return m_processor->Transmit(command);
+}
+
+bool CCECBusDevice::Standby(void)
+{
+ CStdString strLog;
+ strLog.Format("<< putting device with logical address %d in standby mode", (int8_t)m_iLogicalAddress);
+ AddLog(CEC_LOG_DEBUG, strLog.c_str());
+
+ cec_command command;
+ cec_command::format(command, GetMyLogicalAddress(), m_iLogicalAddress, CEC_OPCODE_STANDBY);
+
+ return m_processor->Transmit(command);
+}
+
+/** @name Getters */
+//@{
+cec_version CCECBusDevice::GetCecVersion(void)
+{
+ if (m_cecVersion == CEC_VERSION_UNKNOWN)
+ {
+ if (!MyLogicalAddressContains(m_iLogicalAddress))
+ {
+ AddLog(CEC_LOG_NOTICE, "<< requesting CEC version");
+ cec_command command;
+ cec_command::format(command, GetMyLogicalAddress(), m_iLogicalAddress, CEC_OPCODE_GET_CEC_VERSION);
+ CLockObject lock(&m_mutex);
+ if (m_processor->Transmit(command))
+ m_condition.Wait(&m_mutex, 1000);
+ }
+ }
+
+ return m_cecVersion;
+}
+
+cec_menu_language &CCECBusDevice::GetMenuLanguage(void)
+{
+ if (!strcmp(m_menuLanguage.language, "???"))
+ {
+ if (!MyLogicalAddressContains(m_iLogicalAddress))
+ {
+ AddLog(CEC_LOG_NOTICE, "<< requesting menu language");
+ cec_command command;
+ cec_command::format(command, GetMyLogicalAddress(), m_iLogicalAddress, CEC_OPCODE_GET_MENU_LANGUAGE);
+ CLockObject lock(&m_mutex);
+ if (m_processor->Transmit(command))
+ m_condition.Wait(&m_mutex, 1000);
+ }
+ }
+
+ return m_menuLanguage;
+}
+
cec_logical_address CCECBusDevice::GetMyLogicalAddress(void) const
{
return m_processor->GetLogicalAddress();
return m_processor->GetPhysicalAddress();
}
-void CCECBusDevice::AddLog(cec_log_level level, const CStdString &strMessage)
+cec_power_status CCECBusDevice::GetPowerStatus(void)
{
- m_processor->AddLog(level, strMessage);
+ if (m_powerStatus == CEC_POWER_STATUS_UNKNOWN)
+ {
+ if (!MyLogicalAddressContains(m_iLogicalAddress))
+ {
+ AddLog(CEC_LOG_NOTICE, "<< requesting power status");
+ cec_command command;
+ cec_command::format(command, GetMyLogicalAddress(), m_iLogicalAddress, CEC_OPCODE_GIVE_DEVICE_POWER_STATUS);
+ CLockObject lock(&m_mutex);
+ if (m_processor->Transmit(command))
+ m_condition.Wait(&m_mutex, 1000);
+ }
+ }
+
+ return m_powerStatus;
+}
+
+const cec_vendor &CCECBusDevice::GetVendor(void)
+{
+ if (m_vendor.vendor == CEC_VENDOR_UNKNOWN)
+ {
+ if (!MyLogicalAddressContains(m_iLogicalAddress))
+ {
+ AddLog(CEC_LOG_NOTICE, "<< requesting vendor ID");
+ cec_command command;
+ cec_command::format(command, GetMyLogicalAddress(), m_iLogicalAddress, CEC_OPCODE_GIVE_DEVICE_VENDOR_ID);
+ CLockObject lock(&m_mutex);
+
+ if (m_processor->Transmit(command))
+ m_condition.Wait(&m_mutex, 1000);
+ }
+ }
+
+ return m_vendor;
+}
+
+bool CCECBusDevice::MyLogicalAddressContains(cec_logical_address address) const
+{
+ return m_processor->HasLogicalAddress(address);
+}
+
+//@}
+
+/** @name Setters */
+//@{
+void CCECBusDevice::SetCecVersion(const cec_version newVersion)
+{
+ CStdString strLog;
+ m_cecVersion = newVersion;
+
+ switch (newVersion)
+ {
+ case CEC_VERSION_1_2:
+ strLog.Format("device %d reports CEC version 1.2", m_iLogicalAddress);
+ break;
+ case CEC_VERSION_1_2A:
+ strLog.Format("device %d reports CEC version 1.2a", m_iLogicalAddress);
+ break;
+ case CEC_VERSION_1_3:
+ strLog.Format("device %d reports CEC version 1.3", m_iLogicalAddress);
+ break;
+ case CEC_VERSION_1_3A:
+ strLog.Format("device %d reports CEC version 1.3a", m_iLogicalAddress);
+ break;
+ default:
+ strLog.Format("device %d reports an unknown CEC version", m_iLogicalAddress);
+ m_cecVersion = CEC_VERSION_UNKNOWN;
+ break;
+ }
+ AddLog(CEC_LOG_DEBUG, strLog);
+}
+
+void CCECBusDevice::SetMenuLanguage(const cec_menu_language &language)
+{
+ if (language.device == m_iLogicalAddress)
+ {
+ CStdString strLog;
+ strLog.Format("device %d menu language set to '%s'", m_iLogicalAddress, language.language);
+ m_processor->AddLog(CEC_LOG_DEBUG, strLog);
+ m_menuLanguage = language;
+ }
+}
+
+void CCECBusDevice::SetPhysicalAddress(uint16_t iNewAddress, uint16_t iOldAddress /* = 0 */)
+{
+ if (iNewAddress > 0)
+ {
+ CStdString strLog;
+ strLog.Format(">> %i changed physical address from %04x to %04x", m_iLogicalAddress, m_iPhysicalAddress, iNewAddress);
+ AddLog(CEC_LOG_DEBUG, strLog.c_str());
+
+ m_iPhysicalAddress = iNewAddress;
+ }
+}
+
+void CCECBusDevice::SetPowerStatus(const cec_power_status powerStatus)
+{
+ if (m_powerStatus != powerStatus)
+ {
+ CStdString strLog;
+ strLog.Format("device %d power status changed from %2x to %2x", m_iLogicalAddress, m_powerStatus, powerStatus);
+ m_processor->AddLog(CEC_LOG_DEBUG, strLog);
+ m_powerStatus = powerStatus;
+ }
+}
+
+void CCECBusDevice::SetVendorId(const cec_datapacket &data)
+{
+ if (data.size < 3)
+ {
+ AddLog(CEC_LOG_WARNING, "invalid vendor ID received");
+ return;
+ }
+
+ uint64_t iVendorId = ((uint64_t)data[0] << 3) +
+ ((uint64_t)data[1] << 2) +
+ (uint64_t)data[2];
+
+ SetVendorId(iVendorId, data.size >= 4 ? data[3] : 0);
}
void CCECBusDevice::SetVendorId(uint64_t iVendorId, uint8_t iVendorClass /* = 0 */)
{
- m_iVendorId = iVendorId;
+ m_vendor.vendor = (cec_vendor_id)iVendorId;
m_iVendorClass = iVendorClass;
switch (iVendorId)
m_handler = new CSLCommandHandler(this);
}
break;
+ case CEC_VENDOR_PANASONIC:
+ if (m_handler->GetVendorId() != CEC_VENDOR_PANASONIC)
+ {
+ delete m_handler;
+ m_handler = new CVLCommandHandler(this);
+ }
+ break;
default:
if (m_handler->GetVendorId() != CEC_VENDOR_UNKNOWN)
{
}
CStdString strLog;
- strLog.Format("device %d: vendor = %s (%04x) class = %2x", m_iLogicalAddress, GetVendorName(), GetVendorId(), GetVendorClass());
+ strLog.Format("device %d: vendor = %s (%06x) class = %2x", m_iLogicalAddress, GetVendorName(), GetVendorId(), GetVendorClass());
m_processor->AddLog(CEC_LOG_DEBUG, strLog.c_str());
}
+//@}
-bool CCECBusDevice::HandleCommand(const cec_command &command)
+/** @name Transmit methods */
+//@{
+bool CCECBusDevice::TransmitActiveSource(void)
{
- CLockObject lock(&m_mutex);
- m_iLastActive = GetTimeMs();
- m_handler->HandleCommand(command);
- return true;
+ CStdString strLog;
+ strLog.Format("<< %x -> broadcast: active source (%4x)", m_iLogicalAddress, m_iPhysicalAddress);
+ AddLog(CEC_LOG_NOTICE, strLog);
+
+ cec_command command;
+ cec_command::format(command, m_iLogicalAddress, CECDEVICE_BROADCAST, CEC_OPCODE_ACTIVE_SOURCE);
+ command.parameters.push_back((uint8_t) ((m_iPhysicalAddress >> 8) & 0xFF));
+ command.parameters.push_back((uint8_t) (m_iPhysicalAddress & 0xFF));
+
+ return m_processor->Transmit(command);
}
-void CCECBusDevice::PollVendorId(void)
+bool CCECBusDevice::TransmitActiveView(void)
{
- CLockObject lock(&m_mutex);
- if (m_iLastActive > 0 && m_iVendorId == CEC_VENDOR_UNKNOWN &&
- GetTimeMs() - m_iLastActive > 5000)
- {
- m_iLastActive = GetTimeMs();
+ CStdString strLog;
+ strLog.Format("<< %x -> broadcast: active view (%4x)", m_iLogicalAddress, m_iPhysicalAddress);
+ AddLog(CEC_LOG_NOTICE, strLog);
- cec_command command;
- cec_command::format(command, GetMyLogicalAddress(), GetLogicalAddress(), CEC_OPCODE_GIVE_DEVICE_VENDOR_ID);
- m_processor->Transmit(command, false);
+ cec_command command;
+ cec_command::format(command, m_iLogicalAddress, CECDEVICE_BROADCAST, CEC_OPCODE_ACTIVE_SOURCE);
+ command.parameters.push_back((m_iPhysicalAddress >> 8) & 0xFF);
+ command.parameters.push_back(m_iPhysicalAddress & 0xFF);
+
+ return m_processor->Transmit(command);
+}
+
+bool CCECBusDevice::TransmitCECVersion(cec_logical_address dest)
+{
+ CStdString strLog;
+ strLog.Format("<< %x -> %x: cec version ", m_iLogicalAddress, dest);
+ switch (m_cecVersion)
+ {
+ case CEC_VERSION_1_2:
+ strLog.append("1.2");
+ break;
+ case CEC_VERSION_1_2A:
+ strLog.append("1.2a");
+ break;
+ case CEC_VERSION_1_3:
+ strLog.append("1.3");
+ break;
+ case CEC_VERSION_1_3A:
+ strLog.append("1.3a");
+ break;
+ default:
+ strLog.append("unknown");
+ break;
}
+ AddLog(CEC_LOG_NOTICE, strLog);
+
+ cec_command command;
+ cec_command::format(command, m_iLogicalAddress, dest, CEC_OPCODE_CEC_VERSION);
+ command.parameters.push_back(m_cecVersion);
+
+ return m_processor->Transmit(command);
}
-void CCECBusDevice::SetPhysicalAddress(uint16_t iNewAddress, uint16_t iOldAddress /* = 0 */)
+bool CCECBusDevice::TransmitDeckStatus(cec_logical_address dest)
{
+ // need to support opcodes play and deck control before doing anything with this
CStdString strLog;
- strLog.Format(">> %i changed physical address from %04x to %04x", GetLogicalAddress(), m_iPhysicalAddress, iNewAddress);
- AddLog(CEC_LOG_DEBUG, strLog.c_str());
+ strLog.Format("<< %x -> %x: deck status feature abort", m_iLogicalAddress, dest);
+ AddLog(CEC_LOG_NOTICE, strLog);
- m_iPhysicalAddress = iNewAddress;
+ m_processor->TransmitAbort(dest, CEC_OPCODE_GIVE_DECK_STATUS);
+ return false;
}
-const char *CCECBusDevice::CECVendorIdToString(const uint64_t iVendorId)
+bool CCECBusDevice::TransmitInactiveView(void)
{
- switch (iVendorId)
+ CStdString strLog;
+ strLog.Format("<< %x -> broadcast: inactive view", m_iLogicalAddress);
+ AddLog(CEC_LOG_NOTICE, strLog);
+
+ cec_command command;
+ cec_command::format(command, m_iLogicalAddress, CECDEVICE_BROADCAST, CEC_OPCODE_INACTIVE_SOURCE);
+ command.parameters.push_back((m_iPhysicalAddress >> 8) & 0xFF);
+ command.parameters.push_back(m_iPhysicalAddress & 0xFF);
+
+ return m_processor->Transmit(command);
+}
+
+bool CCECBusDevice::TransmitMenuState(cec_logical_address dest)
+{
+ CStdString strLog;
+ strLog.Format("<< %x -> %x: ", m_iLogicalAddress, dest);
+ if (m_bMenuActive)
+ strLog.append("menu active");
+ else
+ strLog.append("menu inactive");
+ AddLog(CEC_LOG_NOTICE, strLog);
+
+ cec_command command;
+ cec_command::format(command, m_iLogicalAddress, dest, CEC_OPCODE_MENU_STATUS);
+ command.parameters.push_back(m_bMenuActive ? (uint8_t) CEC_MENU_STATE_ACTIVATED : (uint8_t) CEC_MENU_STATE_DEACTIVATED);
+
+ return m_processor->Transmit(command);
+}
+
+bool CCECBusDevice::TransmitOSDName(cec_logical_address dest)
+{
+ CStdString strLog;
+ strLog.Format("<< %x -> %x: OSD name '%s'", m_iLogicalAddress, dest, m_strDeviceName.c_str());
+ AddLog(CEC_LOG_NOTICE, strLog.c_str());
+
+ cec_command command;
+ cec_command::format(command, m_iLogicalAddress, dest, CEC_OPCODE_SET_OSD_NAME);
+ for (unsigned int iPtr = 0; iPtr < m_strDeviceName.length(); iPtr++)
+ command.parameters.push_back(m_strDeviceName.at(iPtr));
+
+ return m_processor->Transmit(command);
+}
+
+bool CCECBusDevice::TransmitOSDString(cec_logical_address dest, cec_display_control duration, const char *strMessage)
+{
+ CStdString strLog;
+ strLog.Format("<< %x -> %x: display OSD message '%s'", m_iLogicalAddress, dest, strMessage);
+ AddLog(CEC_LOG_NOTICE, strLog.c_str());
+
+ cec_command command;
+ cec_command::format(command, m_iLogicalAddress, dest, CEC_OPCODE_SET_OSD_STRING);
+ command.parameters.push_back((uint8_t)duration);
+
+ unsigned int iLen = strlen(strMessage);
+ if (iLen > 13) iLen = 13;
+
+ for (unsigned int iPtr = 0; iPtr < iLen; iPtr++)
+ command.parameters.push_back(strMessage[iPtr]);
+
+ return m_processor->Transmit(command);
+}
+
+bool CCECBusDevice::TransmitPhysicalAddress(void)
+{
+ CStdString strLog;
+ strLog.Format("<< %x -> broadcast: physical adddress %4x", m_iLogicalAddress, m_iPhysicalAddress);
+ AddLog(CEC_LOG_NOTICE, strLog.c_str());
+
+ cec_command command;
+ cec_command::format(command, m_iLogicalAddress, CECDEVICE_BROADCAST, CEC_OPCODE_REPORT_PHYSICAL_ADDRESS);
+ command.parameters.push_back((uint8_t) ((m_iPhysicalAddress >> 8) & 0xFF));
+ command.parameters.push_back((uint8_t) (m_iPhysicalAddress & 0xFF));
+ command.parameters.push_back((uint8_t) (m_type));
+
+ return m_processor->Transmit(command);
+}
+
+bool CCECBusDevice::TransmitPoll(cec_logical_address dest)
+{
+ bool bReturn(false);
+
+ if (dest == CECDEVICE_UNKNOWN)
+ dest = m_iLogicalAddress;
+
+ CStdString strLog;
+ strLog.Format("<< %x -> %x: POLL", m_iLogicalAddress, dest);
+ AddLog(CEC_LOG_NOTICE, strLog.c_str());
+
+ cec_command command;
+ cec_command::format(command, m_iLogicalAddress, dest, CEC_OPCODE_NONE);
+ CLockObject lock(&m_mutex);
+
+ bReturn = m_processor->Transmit(command);
+ AddLog(CEC_LOG_DEBUG, bReturn ? ">> POLL sent" : ">> POLL not sent");
+ return bReturn;
+}
+
+bool CCECBusDevice::TransmitPowerState(cec_logical_address dest)
+{
+ CStdString strLog;
+ strLog.Format("<< %x -> %x: ", m_iLogicalAddress, dest);
+
+ switch (m_powerStatus)
{
- case CEC_VENDOR_SAMSUNG:
- return "Samsung";
- case CEC_VENDOR_LG:
- return "LG";
+ case CEC_POWER_STATUS_ON:
+ strLog.append("powered on");
+ break;
+ case CEC_POWER_STATUS_STANDBY:
+ strLog.append("in standby mode");
+ break;
+ case CEC_POWER_STATUS_IN_TRANSITION_ON_TO_STANDBY:
+ strLog.append("in transition from on to standby");
+ break;
+ case CEC_POWER_STATUS_IN_TRANSITION_STANDBY_TO_ON:
+ strLog.append("in transition from standby to on");
+ break;
default:
- return "Unknown";
+ strLog.append("power state unknown");
+ break;
}
+ AddLog(CEC_LOG_NOTICE, strLog.c_str());
+
+ strLog.Format("<< reporting power status '%d'", m_powerStatus);
+ AddLog(CEC_LOG_NOTICE, strLog);
+
+ cec_command command;
+ cec_command::format(command, m_iLogicalAddress, dest, CEC_OPCODE_REPORT_POWER_STATUS);
+ command.parameters.push_back((uint8_t) m_powerStatus);
+
+ return m_processor->Transmit(command);
+}
+
+bool CCECBusDevice::TransmitVendorID(cec_logical_address dest)
+{
+ CStdString strLog;
+ strLog.Format("<< %x -> %x: vendor id feature abort", m_iLogicalAddress, dest);
+ AddLog(CEC_LOG_NOTICE, strLog);
+
+ m_processor->TransmitAbort(dest, CEC_OPCODE_GIVE_DEVICE_VENDOR_ID);
+ return false;
}
+//@}