cec: renamed enum methods. fixes potential macro collision with isset(). thanks davilla
[deb_libcec.git] / src / lib / devices / CECBusDevice.cpp
index 600356598ee425eacceca4749482fef66952c5ab..d4d3814768cbe6828c8894fafe07a6571ce24b2f 100644 (file)
 
 using namespace CEC;
 
+#define ToString(p) CCECCommandHandler::ToString(p)
+
 CCECBusDevice::CCECBusDevice(CCECProcessor *processor, cec_logical_address iLogicalAddress, uint16_t iPhysicalAddress) :
+  m_type(CEC_DEVICE_TYPE_RESERVED),
   m_iPhysicalAddress(iPhysicalAddress),
+  m_iStreamPath(0),
   m_iLogicalAddress(iLogicalAddress),
   m_powerStatus(CEC_POWER_STATUS_UNKNOWN),
   m_processor(processor),
-  m_bMenuActive(true),
-  m_iVendorClass(CEC_VENDOR_UNKNOWN),
+  m_vendor(CEC_VENDOR_UNKNOWN),
+  m_menuState(CEC_MENU_STATE_ACTIVATED),
+  m_bActiveSource(false),
+  m_iLastCommandSent(0),
   m_iLastActive(0),
-  m_cecVersion(CEC_VERSION_1_3A)
+  m_cecVersion(CEC_VERSION_UNKNOWN)
 {
   m_handler = new CCECCommandHandler(this);
 
@@ -57,9 +63,7 @@ CCECBusDevice::CCECBusDevice(CCECProcessor *processor, cec_logical_address iLogi
   m_menuLanguage.language[3] = 0;
   m_menuLanguage.device = iLogicalAddress;
 
-  m_vendor.vendor = CEC_VENDOR_UNKNOWN;
-  m_type          = CEC_DEVICE_TYPE_RESERVED;
-  m_strDeviceName = "Unknown";
+  m_strDeviceName = ToString(m_iLogicalAddress);
 }
 
 CCECBusDevice::~CCECBusDevice(void)
@@ -86,13 +90,17 @@ void CCECBusDevice::PollVendorId(void)
 {
   CLockObject lock(&m_mutex);
   if (m_iLastActive > 0 && m_iLogicalAddress != CECDEVICE_BROADCAST &&
-      m_vendor.vendor == CEC_VENDOR_UNKNOWN &&
-      GetTimeMs() - m_iLastActive > 5000)
+      m_vendor == CEC_VENDOR_UNKNOWN &&
+      GetTimeMs() - m_iLastCommandSent > 5000 &&
+      !m_processor->IsMonitoring())
   {
-    m_iLastActive = GetTimeMs();
+    CStdString strLog;
+    strLog.Format("<< requesting vendor ID of '%s' (%X)", GetLogicalAddressName(), m_iLogicalAddress);
+    AddLog(CEC_LOG_NOTICE, strLog);
+    m_iLastCommandSent = GetTimeMs();
 
     cec_command command;
-    cec_command::format(command, GetMyLogicalAddress(), m_iLogicalAddress, CEC_OPCODE_GIVE_DEVICE_VENDOR_ID);
+    cec_command::Format(command, GetMyLogicalAddress(), m_iLogicalAddress, CEC_OPCODE_GIVE_DEVICE_VENDOR_ID);
     if (m_processor->Transmit(command))
       m_condition.Wait(&m_mutex, 1000);
   }
@@ -100,55 +108,79 @@ void CCECBusDevice::PollVendorId(void)
 
 bool CCECBusDevice::PowerOn(void)
 {
-  CStdString strLog;
-  strLog.Format("<< powering on device with logical address %d", (int8_t)m_iLogicalAddress);
-  AddLog(CEC_LOG_DEBUG, strLog.c_str());
+  cec_power_status current = GetPowerStatus();
+  if (current != CEC_POWER_STATUS_ON &&
+      current != CEC_POWER_STATUS_IN_TRANSITION_STANDBY_TO_ON)
+  {
+    CStdString strLog;
+    strLog.Format("<< powering on '%s' (%X)", GetLogicalAddressName(), m_iLogicalAddress);
+    AddLog(CEC_LOG_DEBUG, strLog.c_str());
 
-  cec_command command;
-  cec_command::format(command, GetMyLogicalAddress(), m_iLogicalAddress, CEC_OPCODE_IMAGE_VIEW_ON);
+    SetPowerStatus(CEC_POWER_STATUS_IN_TRANSITION_STANDBY_TO_ON);
 
-  return m_processor->Transmit(command);
+    cec_command command;
+    cec_command::Format(command, GetMyLogicalAddress(), m_iLogicalAddress, CEC_OPCODE_IMAGE_VIEW_ON);
+
+    return m_processor->Transmit(command);
+  }
+
+  return true;
 }
 
 bool CCECBusDevice::Standby(void)
 {
   CStdString strLog;
-  strLog.Format("<< putting device with logical address %d in standby mode", (int8_t)m_iLogicalAddress);
+  strLog.Format("<< putting '%s' (%X) in standby mode", GetLogicalAddressName(), m_iLogicalAddress);
   AddLog(CEC_LOG_DEBUG, strLog.c_str());
 
   cec_command command;
-  cec_command::format(command, GetMyLogicalAddress(), m_iLogicalAddress, CEC_OPCODE_STANDBY);
+  cec_command::Format(command, GetMyLogicalAddress(), m_iLogicalAddress, CEC_OPCODE_STANDBY);
 
   return m_processor->Transmit(command);
 }
 
 /** @name Getters */
 //@{
-cec_version CCECBusDevice::GetCecVersion(bool bRefresh /* = true */)
+cec_version CCECBusDevice::GetCecVersion(void)
 {
-  if (bRefresh || m_cecVersion == CEC_VERSION_UNKNOWN)
+  if (m_cecVersion == CEC_VERSION_UNKNOWN)
   {
-    AddLog(CEC_LOG_NOTICE, "<< requesting CEC version");
-    cec_command command;
-    cec_command::format(command, GetMyLogicalAddress(), m_iLogicalAddress, CEC_OPCODE_GET_CEC_VERSION);
-    CLockObject lock(&m_mutex);
-    if (m_processor->Transmit(command))
-      m_condition.Wait(&m_mutex, 1000);
+    if (!MyLogicalAddressContains(m_iLogicalAddress))
+    {
+      CStdString strLog;
+      strLog.Format("<< requesting CEC version of '%s' (%X)", GetLogicalAddressName(), m_iLogicalAddress);
+      AddLog(CEC_LOG_NOTICE, strLog);
+      cec_command command;
+      cec_command::Format(command, GetMyLogicalAddress(), m_iLogicalAddress, CEC_OPCODE_GET_CEC_VERSION);
+      CLockObject lock(&m_mutex);
+      if (m_processor->Transmit(command))
+        m_condition.Wait(&m_mutex, 1000);
+    }
   }
 
   return m_cecVersion;
 }
 
-cec_menu_language &CCECBusDevice::GetMenuLanguage(bool bRefresh /* = true */)
+const char* CCECBusDevice::GetLogicalAddressName(void) const
+{
+  return ToString(m_iLogicalAddress);
+}
+
+cec_menu_language &CCECBusDevice::GetMenuLanguage(void)
 {
-  if (bRefresh || !strcmp(m_menuLanguage.language, "???"))
+  if (!strcmp(m_menuLanguage.language, "???"))
   {
-    AddLog(CEC_LOG_NOTICE, "<< requesting menu language");
-    cec_command command;
-    cec_command::format(command, GetMyLogicalAddress(), m_iLogicalAddress, CEC_OPCODE_GET_MENU_LANGUAGE);
-    CLockObject lock(&m_mutex);
-    if (m_processor->Transmit(command))
-      m_condition.Wait(&m_mutex, 1000);
+    if (!MyLogicalAddressContains(m_iLogicalAddress))
+    {
+      CStdString strLog;
+      strLog.Format("<< requesting menu language of '%s' (%X)", GetLogicalAddressName(), m_iLogicalAddress);
+      AddLog(CEC_LOG_NOTICE, strLog);
+      cec_command command;
+      cec_command::Format(command, GetMyLogicalAddress(), m_iLogicalAddress, CEC_OPCODE_GET_MENU_LANGUAGE);
+      CLockObject lock(&m_mutex);
+      if (m_processor->Transmit(command))
+        m_condition.Wait(&m_mutex, 1000);
+    }
   }
 
   return m_menuLanguage;
@@ -164,37 +196,53 @@ uint16_t CCECBusDevice::GetMyPhysicalAddress(void) const
   return m_processor->GetPhysicalAddress();
 }
 
-cec_power_status CCECBusDevice::GetPowerStatus(bool bRefresh /* = true */)
+cec_power_status CCECBusDevice::GetPowerStatus(void)
 {
-  if (bRefresh || m_powerStatus == CEC_POWER_STATUS_UNKNOWN)
+  if (m_powerStatus == CEC_POWER_STATUS_UNKNOWN)
   {
-    AddLog(CEC_LOG_NOTICE, "<< requesting power status");
-    cec_command command;
-    cec_command::format(command, GetMyLogicalAddress(), m_iLogicalAddress, CEC_OPCODE_GIVE_DEVICE_POWER_STATUS);
-    CLockObject lock(&m_mutex);
-    if (m_processor->Transmit(command))
-      m_condition.Wait(&m_mutex, 1000);
+    if (!MyLogicalAddressContains(m_iLogicalAddress))
+    {
+      CStdString strLog;
+      strLog.Format("<< requesting power status of '%s' (%X)", GetLogicalAddressName(), m_iLogicalAddress);
+      AddLog(CEC_LOG_NOTICE, strLog);
+      cec_command command;
+      cec_command::Format(command, GetMyLogicalAddress(), m_iLogicalAddress, CEC_OPCODE_GIVE_DEVICE_POWER_STATUS);
+      CLockObject lock(&m_mutex);
+      if (m_processor->Transmit(command))
+        m_condition.Wait(&m_mutex, 1000);
+    }
   }
 
   return m_powerStatus;
 }
 
-const cec_vendor &CCECBusDevice::GetVendor(void)
+const cec_vendor_id CCECBusDevice::GetVendorId(void)
 {
-  if (m_vendor.vendor == CEC_VENDOR_UNKNOWN)
+  if (m_vendor == CEC_VENDOR_UNKNOWN)
   {
-    AddLog(CEC_LOG_NOTICE, "<< requesting vendor ID");
-    cec_command command;
-    cec_command::format(command, GetMyLogicalAddress(), m_iLogicalAddress, CEC_OPCODE_GIVE_DEVICE_VENDOR_ID);
-    CLockObject lock(&m_mutex);
-
-    if (m_processor->Transmit(command))
-      m_condition.Wait(&m_mutex, 1000);
+    if (!MyLogicalAddressContains(m_iLogicalAddress))
+    {
+      CStdString strLog;
+      strLog.Format("<< requesting vendor ID of '%s' (%X)", GetLogicalAddressName(), m_iLogicalAddress);
+      AddLog(CEC_LOG_NOTICE, strLog);
+      cec_command command;
+      cec_command::Format(command, GetMyLogicalAddress(), m_iLogicalAddress, CEC_OPCODE_GIVE_DEVICE_VENDOR_ID);
+      CLockObject lock(&m_mutex);
+
+      if (m_processor->Transmit(command))
+        m_condition.Wait(&m_mutex, 1000);
+    }
   }
 
   return m_vendor;
 }
 
+const char *CCECBusDevice::GetVendorName(void)
+{
+  GetVendorId();
+  return ToString(m_vendor);
+}
+
 bool CCECBusDevice::MyLogicalAddressContains(cec_logical_address address) const
 {
   return m_processor->HasLogicalAddress(address);
@@ -206,28 +254,10 @@ bool CCECBusDevice::MyLogicalAddressContains(cec_logical_address address) const
 //@{
 void CCECBusDevice::SetCecVersion(const cec_version newVersion)
 {
-  CStdString strLog;
   m_cecVersion = newVersion;
 
-  switch (newVersion)
-  {
-  case CEC_VERSION_1_2:
-    strLog.Format("device %d reports CEC version 1.2", m_iLogicalAddress);
-    break;
-  case CEC_VERSION_1_2A:
-    strLog.Format("device %d reports CEC version 1.2a", m_iLogicalAddress);
-    break;
-  case CEC_VERSION_1_3:
-    strLog.Format("device %d reports CEC version 1.3", m_iLogicalAddress);
-    break;
-  case CEC_VERSION_1_3A:
-    strLog.Format("device %d reports CEC version 1.3a", m_iLogicalAddress);
-    break;
-  default:
-    strLog.Format("device %d reports an unknown CEC version", m_iLogicalAddress);
-    m_cecVersion = CEC_VERSION_UNKNOWN;
-    break;
-  }
+  CStdString strLog;
+  strLog.Format("%s (%X): CEC version %s", GetLogicalAddressName(), m_iLogicalAddress, ToString(newVersion));
   AddLog(CEC_LOG_DEBUG, strLog);
 }
 
@@ -236,54 +266,64 @@ void CCECBusDevice::SetMenuLanguage(const cec_menu_language &language)
   if (language.device == m_iLogicalAddress)
   {
     CStdString strLog;
-    strLog.Format("device %d menu language set to '%s'", m_iLogicalAddress, language.language);
+    strLog.Format(">> %s (%X): menu language set to '%s'", GetLogicalAddressName(), m_iLogicalAddress, language.language);
     m_processor->AddLog(CEC_LOG_DEBUG, strLog);
     m_menuLanguage = language;
   }
 }
 
-void CCECBusDevice::SetPhysicalAddress(uint16_t iNewAddress, uint16_t iOldAddress /* = 0 */)
+void CCECBusDevice::SetMenuState(const cec_menu_state state)
+{
+  if (m_menuState != state)
+  {
+    CStdString strLog;
+    strLog.Format(">> %s (%X): menu state set to '%s'", GetLogicalAddressName(), m_iLogicalAddress, ToString(m_menuState));
+    m_processor->AddLog(CEC_LOG_DEBUG, strLog);
+    m_menuState = state;
+  }
+}
+
+void CCECBusDevice::SetPhysicalAddress(uint16_t iNewAddress)
 {
   if (iNewAddress > 0)
   {
     CStdString strLog;
-    strLog.Format(">> %i changed physical address from %04x to %04x", m_iLogicalAddress, m_iPhysicalAddress, iNewAddress);
+    strLog.Format(">> %s (%X): physical address changed from %04x to %04x", GetLogicalAddressName(), m_iLogicalAddress, m_iPhysicalAddress, iNewAddress);
     AddLog(CEC_LOG_DEBUG, strLog.c_str());
 
     m_iPhysicalAddress = iNewAddress;
   }
 }
 
-void CCECBusDevice::SetPowerStatus(const cec_power_status powerStatus)
+void CCECBusDevice::SetStreamPath(uint16_t iNewAddress, uint16_t iOldAddress /* = 0 */)
 {
-  if (m_powerStatus != powerStatus)
+  if (iNewAddress > 0)
   {
     CStdString strLog;
-    strLog.Format("device %d power status changed from %2x to %2x", m_iLogicalAddress, m_powerStatus, powerStatus);
-    m_processor->AddLog(CEC_LOG_DEBUG, strLog);
-    m_powerStatus = powerStatus;
+    strLog.Format(">> %s (%X): stream path changed from %04x to %04x", GetLogicalAddressName(), m_iLogicalAddress, iOldAddress, iNewAddress);
+    AddLog(CEC_LOG_DEBUG, strLog.c_str());
+
+    m_iStreamPath = iNewAddress;
+
+    if (iNewAddress > 0)
+      SetPowerStatus(CEC_POWER_STATUS_ON);
   }
 }
 
-void CCECBusDevice::SetVendorId(const cec_datapacket &data)
+void CCECBusDevice::SetPowerStatus(const cec_power_status powerStatus)
 {
-  if (data.size < 3)
+  if (m_powerStatus != powerStatus)
   {
-    AddLog(CEC_LOG_WARNING, "invalid vendor ID received");
-    return;
+    CStdString strLog;
+    strLog.Format(">> %s (%X): power status changed from '%s' to '%s'", GetLogicalAddressName(), m_iLogicalAddress, ToString(m_powerStatus), ToString(powerStatus));
+    m_processor->AddLog(CEC_LOG_DEBUG, strLog);
+    m_powerStatus = powerStatus;
   }
-
-  uint64_t iVendorId = ((uint64_t)data[0] << 3) +
-                       ((uint64_t)data[1] << 2) +
-                        (uint64_t)data[2];
-
-  SetVendorId(iVendorId, data.size >= 4 ? data[3] : 0);
 }
 
-void CCECBusDevice::SetVendorId(uint64_t iVendorId, uint8_t iVendorClass /* = 0 */)
+void CCECBusDevice::SetVendorId(uint64_t iVendorId)
 {
-  m_vendor.vendor = (cec_vendor_id)iVendorId;
-  m_iVendorClass = iVendorClass;
+  m_vendor = (cec_vendor_id)iVendorId;
 
   switch (iVendorId)
   {
@@ -318,7 +358,7 @@ void CCECBusDevice::SetVendorId(uint64_t iVendorId, uint8_t iVendorClass /* = 0
   }
 
   CStdString strLog;
-  strLog.Format("device %d: vendor = %s (%06x) class = %2x", m_iLogicalAddress, GetVendorName(), GetVendorId(), GetVendorClass());
+  strLog.Format("%s (%X): vendor = %s (%06x)", GetLogicalAddressName(), m_iLogicalAddress, GetVendorName(), GetVendorId());
   m_processor->AddLog(CEC_LOG_DEBUG, strLog.c_str());
 }
 //@}
@@ -327,69 +367,71 @@ void CCECBusDevice::SetVendorId(uint64_t iVendorId, uint8_t iVendorClass /* = 0
 //@{
 bool CCECBusDevice::TransmitActiveSource(void)
 {
-  AddLog(CEC_LOG_NOTICE, "<< broadcasting active source");
-
-  cec_command command;
-  cec_command::format(command, m_iLogicalAddress, CECDEVICE_BROADCAST, CEC_OPCODE_ACTIVE_SOURCE);
-  command.parameters.push_back((uint8_t) ((m_iPhysicalAddress >> 8) & 0xFF));
-  command.parameters.push_back((uint8_t) (m_iPhysicalAddress & 0xFF));
-
-  return m_processor->Transmit(command);
-}
+  if (m_powerStatus != CEC_POWER_STATUS_ON)
+  {
+    CStdString strLog;
+    strLog.Format("<< %s (%X) is not powered on", GetLogicalAddressName(), m_iLogicalAddress);
+    AddLog(CEC_LOG_DEBUG, strLog);
+  }
+  else if (m_bActiveSource)
+  {
+    CStdString strLog;
+    strLog.Format("<< %s (%X) -> broadcast (F): active source (%4x)", GetLogicalAddressName(), m_iLogicalAddress, m_iPhysicalAddress);
+    AddLog(CEC_LOG_NOTICE, strLog);
 
-bool CCECBusDevice::TransmitActiveView(void)
-{
-  AddLog(CEC_LOG_DEBUG, "<< setting active view");
+    cec_command command;
+    cec_command::Format(command, m_iLogicalAddress, CECDEVICE_BROADCAST, CEC_OPCODE_ACTIVE_SOURCE);
+    command.parameters.PushBack((uint8_t) ((m_iPhysicalAddress >> 8) & 0xFF));
+    command.parameters.PushBack((uint8_t) (m_iPhysicalAddress & 0xFF));
 
-  cec_command command;
-  cec_command::format(command, m_iLogicalAddress, CECDEVICE_BROADCAST, CEC_OPCODE_ACTIVE_SOURCE);
-  command.parameters.push_back((m_iPhysicalAddress >> 8) & 0xFF);
-  command.parameters.push_back(m_iPhysicalAddress & 0xFF);
+    return m_processor->Transmit(command);
+  }
+  else
+  {
+    CStdString strLog;
+    strLog.Format("<< %s (%X) is not the active source", GetLogicalAddressName(), m_iLogicalAddress);
+    AddLog(CEC_LOG_DEBUG, strLog);
+  }
 
-  return m_processor->Transmit(command);
+  return false;
 }
 
 bool CCECBusDevice::TransmitCECVersion(cec_logical_address dest)
 {
-  AddLog(CEC_LOG_NOTICE, "<< reporting CEC version as 1.3a");
+  CStdString strLog;
+  strLog.Format("<< %s (%X) -> %s (%X): cec version %s", GetLogicalAddressName(), m_iLogicalAddress, ToString(dest), dest, ToString(m_cecVersion));
+  AddLog(CEC_LOG_NOTICE, strLog);
 
   cec_command command;
-  cec_command::format(command, m_iLogicalAddress, dest, CEC_OPCODE_CEC_VERSION);
-  command.parameters.push_back(m_cecVersion);
+  cec_command::Format(command, m_iLogicalAddress, dest, CEC_OPCODE_CEC_VERSION);
+  command.parameters.PushBack((uint8_t)m_cecVersion);
 
   return m_processor->Transmit(command);
 }
 
-bool CCECBusDevice::TransmitDeckStatus(cec_logical_address dest)
-{
-  // need to support opcodes play and deck control before doing anything with this
-  AddLog(CEC_LOG_NOTICE, "<< deck status requested, feature abort");
-  m_processor->TransmitAbort(dest, CEC_OPCODE_GIVE_DEVICE_VENDOR_ID);
-  return false;
-}
-
 bool CCECBusDevice::TransmitInactiveView(void)
 {
-  AddLog(CEC_LOG_DEBUG, "<< setting inactive view");
+  CStdString strLog;
+  strLog.Format("<< %s (%X) -> broadcast (F): inactive view", GetLogicalAddressName(), m_iLogicalAddress);
+  AddLog(CEC_LOG_NOTICE, strLog);
 
   cec_command command;
-  cec_command::format(command, m_iLogicalAddress, CECDEVICE_BROADCAST, CEC_OPCODE_INACTIVE_SOURCE);
-  command.parameters.push_back((m_iPhysicalAddress >> 8) & 0xFF);
-  command.parameters.push_back(m_iPhysicalAddress & 0xFF);
+  cec_command::Format(command, m_iLogicalAddress, CECDEVICE_BROADCAST, CEC_OPCODE_INACTIVE_SOURCE);
+  command.parameters.PushBack((m_iPhysicalAddress >> 8) & 0xFF);
+  command.parameters.PushBack(m_iPhysicalAddress & 0xFF);
 
   return m_processor->Transmit(command);
 }
 
 bool CCECBusDevice::TransmitMenuState(cec_logical_address dest)
 {
-  if (m_bMenuActive)
-    AddLog(CEC_LOG_NOTICE, "<< reporting menu state as active");
-  else
-    AddLog(CEC_LOG_NOTICE, "<< reporting menu state as inactive");
+  CStdString strLog;
+  strLog.Format("<< %s (%X) -> %s (%X): menu state '%s'", GetLogicalAddressName(), m_iLogicalAddress, ToString(dest), dest, ToString(m_menuState));
+  AddLog(CEC_LOG_NOTICE, strLog);
 
   cec_command command;
-  cec_command::format(command, m_iLogicalAddress, dest, CEC_OPCODE_MENU_STATUS);
-  command.parameters.push_back(m_bMenuActive ? (uint8_t) CEC_MENU_STATE_ACTIVATED : (uint8_t) CEC_MENU_STATE_DEACTIVATED);
+  cec_command::Format(command, m_iLogicalAddress, dest, CEC_OPCODE_MENU_STATUS);
+  command.parameters.PushBack((uint8_t)m_menuState);
 
   return m_processor->Transmit(command);
 }
@@ -397,13 +439,13 @@ bool CCECBusDevice::TransmitMenuState(cec_logical_address dest)
 bool CCECBusDevice::TransmitOSDName(cec_logical_address dest)
 {
   CStdString strLog;
-  strLog.Format("<< reporting OSD name as %s", m_strDeviceName.c_str());
+  strLog.Format("<< %s (%X) -> %s (%X): OSD name '%s'", GetLogicalAddressName(), m_iLogicalAddress, ToString(dest), dest, m_strDeviceName.c_str());
   AddLog(CEC_LOG_NOTICE, strLog.c_str());
 
   cec_command command;
-  cec_command::format(command, m_iLogicalAddress, dest, CEC_OPCODE_SET_OSD_NAME);
+  cec_command::Format(command, m_iLogicalAddress, dest, CEC_OPCODE_SET_OSD_NAME);
   for (unsigned int iPtr = 0; iPtr < m_strDeviceName.length(); iPtr++)
-    command.parameters.push_back(m_strDeviceName.at(iPtr));
+    command.parameters.PushBack(m_strDeviceName.at(iPtr));
 
   return m_processor->Transmit(command);
 }
@@ -411,18 +453,18 @@ bool CCECBusDevice::TransmitOSDName(cec_logical_address dest)
 bool CCECBusDevice::TransmitOSDString(cec_logical_address dest, cec_display_control duration, const char *strMessage)
 {
   CStdString strLog;
-  strLog.Format("<< display message '%s'", strMessage);
+  strLog.Format("<< %s (%X) -> %s (%X): display OSD message '%s'", GetLogicalAddressName(), m_iLogicalAddress, ToString(dest), dest, strMessage);
   AddLog(CEC_LOG_NOTICE, strLog.c_str());
 
   cec_command command;
-  cec_command::format(command, m_iLogicalAddress, dest, CEC_OPCODE_SET_OSD_STRING);
-  command.parameters.push_back((uint8_t)duration);
+  cec_command::Format(command, m_iLogicalAddress, dest, CEC_OPCODE_SET_OSD_STRING);
+  command.parameters.PushBack((uint8_t)duration);
 
   unsigned int iLen = strlen(strMessage);
   if (iLen > 13) iLen = 13;
 
   for (unsigned int iPtr = 0; iPtr < iLen; iPtr++)
-    command.parameters.push_back(strMessage[iPtr]);
+    command.parameters.PushBack(strMessage[iPtr]);
 
   return m_processor->Transmit(command);
 }
@@ -430,14 +472,14 @@ bool CCECBusDevice::TransmitOSDString(cec_logical_address dest, cec_display_cont
 bool CCECBusDevice::TransmitPhysicalAddress(void)
 {
   CStdString strLog;
-  strLog.Format("<< reporting physical address as %04x", m_iPhysicalAddress);
+  strLog.Format("<< %s (%X) -> broadcast (F): physical adddress %4x", GetLogicalAddressName(), m_iLogicalAddress, m_iPhysicalAddress);
   AddLog(CEC_LOG_NOTICE, strLog.c_str());
 
   cec_command command;
-  cec_command::format(command, m_iLogicalAddress, CECDEVICE_BROADCAST, CEC_OPCODE_REPORT_PHYSICAL_ADDRESS);
-  command.parameters.push_back((uint8_t) ((m_iPhysicalAddress >> 8) & 0xFF));
-  command.parameters.push_back((uint8_t) (m_iPhysicalAddress & 0xFF));
-  command.parameters.push_back((uint8_t) (CEC_DEVICE_TYPE_PLAYBACK_DEVICE));
+  cec_command::Format(command, m_iLogicalAddress, CECDEVICE_BROADCAST, CEC_OPCODE_REPORT_PHYSICAL_ADDRESS);
+  command.parameters.PushBack((uint8_t) ((m_iPhysicalAddress >> 8) & 0xFF));
+  command.parameters.PushBack((uint8_t) (m_iPhysicalAddress & 0xFF));
+  command.parameters.PushBack((uint8_t) (m_type));
 
   return m_processor->Transmit(command);
 }
@@ -450,11 +492,11 @@ bool CCECBusDevice::TransmitPoll(cec_logical_address dest)
     dest = m_iLogicalAddress;
 
   CStdString strLog;
-  strLog.Format("<< sending POLL from device %1x to device %1x", m_iLogicalAddress, (int8_t)dest);
-  AddLog(CEC_LOG_DEBUG, strLog);
+  strLog.Format("<< %s (%X) -> %s (%X): POLL", GetLogicalAddressName(), m_iLogicalAddress, ToString(dest), dest);
+  AddLog(CEC_LOG_NOTICE, strLog.c_str());
 
   cec_command command;
-  cec_command::format(command, m_iLogicalAddress, dest, CEC_OPCODE_NONE);
+  cec_command::Format(command, m_iLogicalAddress, dest, CEC_OPCODE_NONE);
   CLockObject lock(&m_mutex);
 
   bReturn = m_processor->Transmit(command);
@@ -465,20 +507,41 @@ bool CCECBusDevice::TransmitPoll(cec_logical_address dest)
 bool CCECBusDevice::TransmitPowerState(cec_logical_address dest)
 {
   CStdString strLog;
-  strLog.Format("<< reporting power status '%d'", m_powerStatus);
-  AddLog(CEC_LOG_NOTICE, strLog);
+  strLog.Format("<< %s (%X) -> %s (%X): %s", GetLogicalAddressName(), m_iLogicalAddress, ToString(dest), dest, ToString(m_powerStatus));
+  AddLog(CEC_LOG_NOTICE, strLog.c_str());
 
   cec_command command;
-  cec_command::format(command, m_iLogicalAddress, dest, CEC_OPCODE_REPORT_POWER_STATUS);
-  command.parameters.push_back((uint8_t) m_powerStatus);
+  cec_command::Format(command, m_iLogicalAddress, dest, CEC_OPCODE_REPORT_POWER_STATUS);
+  command.parameters.PushBack((uint8_t) m_powerStatus);
 
   return m_processor->Transmit(command);
 }
 
 bool CCECBusDevice::TransmitVendorID(cec_logical_address dest)
 {
-  AddLog(CEC_LOG_NOTICE, "<< vendor ID requested, feature abort");
-  m_processor->TransmitAbort(dest, CEC_OPCODE_GIVE_DEVICE_VENDOR_ID);
-  return false;
+  if (m_vendor == CEC_VENDOR_UNKNOWN)
+  {
+    CStdString strLog;
+    strLog.Format("<< %s (%X) -> %s (%X): vendor id feature abort", GetLogicalAddressName(), m_iLogicalAddress, ToString(dest), dest);
+    AddLog(CEC_LOG_NOTICE, strLog);
+
+    m_processor->TransmitAbort(dest, CEC_OPCODE_GIVE_DEVICE_VENDOR_ID);
+    return false;
+  }
+  else
+  {
+    CStdString strLog;
+    strLog.Format("<< %s (%X) -> %s (%X): vendor id %s (%x)", GetLogicalAddressName(), m_iLogicalAddress, ToString(dest), dest, ToString(m_vendor), (uint64_t)m_vendor);
+    AddLog(CEC_LOG_NOTICE, strLog);
+
+    cec_command command;
+    cec_command::Format(command, m_iLogicalAddress, dest, CEC_OPCODE_GIVE_DEVICE_VENDOR_ID);
+
+    command.parameters.PushBack((uint8_t) (((uint64_t)m_vendor >> 16) & 0xFF));
+    command.parameters.PushBack((uint8_t) (((uint64_t)m_vendor >> 8) & 0xFF));
+    command.parameters.PushBack((uint8_t) ((uint64_t)m_vendor & 0xFF));
+
+    return m_processor->Transmit(command);
+  }
 }
 //@}