-import { MeterValueMeasurand } from '../types/ocpp/MeterValues';
-
-export default class Constants {
- static readonly OCPP_DEFAULT_BOOT_NOTIFICATION_INTERVAL = 60000; // Ms
- static readonly OCPP_WEBSOCKET_TIMEOUT = 60000; // Ms
- static readonly OCPP_TRIGGER_MESSAGE_DELAY = 500; // Ms
-
- static readonly CHARGING_STATION_DEFAULT_RESET_TIME = 60000; // Ms
- static readonly CHARGING_STATION_ATG_INITIALIZATION_TIME = 1000; // Ms
- static readonly CHARGING_STATION_ATG_DEFAULT_STOP_AFTER_HOURS = 0.25; // Hours
-
+import {
+ type AutomaticTransactionGeneratorConfiguration,
+ type ChargingStationInfo,
+ CurrentType,
+ type IncomingRequestCommand,
+ OCPPVersion,
+ type RequestCommand,
+ VendorParametersKey
+} from '../types/index.js'
+
+// eslint-disable-next-line @typescript-eslint/no-extraneous-class
+export class Constants {
// See https://semver.org/#is-there-a-suggested-regular-expression-regex-to-check-a-semver-string
- static readonly SEMVER_PATTERN =
- '^(0|[1-9]\\d*)\\.(0|[1-9]\\d*)\\.(0|[1-9]\\d*)(?:-((?:0|[1-9]\\d*|\\d*[a-zA-Z-][0-9a-zA-Z-]*)(?:\\.(?:0|[1-9]\\d*|\\d*[a-zA-Z-][0-9a-zA-Z-]*))*))?(?:\\+([0-9a-zA-Z-]+(?:\\.[0-9a-zA-Z-]+)*))?$';
-
- static readonly DEFAULT_CIRCULAR_BUFFER_CAPACITY = 1024;
-
- static readonly DEFAULT_HASH_ALGORITHM = 'sha384';
-
- static readonly DEFAULT_IDTAG = '00000000';
-
- static readonly DEFAULT_CONNECTION_TIMEOUT = 30;
-
- static readonly DEFAULT_LOG_STATISTICS_INTERVAL = 60; // Seconds
-
- static readonly DEFAULT_HEARTBEAT_INTERVAL = 60000; // Ms
- static readonly DEFAULT_METER_VALUES_INTERVAL = 60000; // Ms
-
- static readonly SUPPORTED_MEASURANDS = Object.freeze([
- MeterValueMeasurand.STATE_OF_CHARGE,
- MeterValueMeasurand.VOLTAGE,
- MeterValueMeasurand.POWER_ACTIVE_IMPORT,
- MeterValueMeasurand.CURRENT_IMPORT,
- MeterValueMeasurand.ENERGY_ACTIVE_IMPORT_REGISTER,
- ]);
-
- static readonly DEFAULT_FLUCTUATION_PERCENT = 5;
-
- static readonly DEFAULT_PERFORMANCE_RECORDS_FILENAME = 'performanceRecords.json';
- static readonly DEFAULT_PERFORMANCE_RECORDS_DB_NAME = 'e-mobility-charging-stations-simulator';
- static readonly PERFORMANCE_RECORDS_TABLE = 'performance_records';
-
- static readonly DEFAULT_UI_SERVER_HOST = 'localhost';
- static readonly DEFAULT_UI_SERVER_PORT = 8080;
-
- static readonly UNKNOWN_COMMAND = 'unknown command';
-
- static readonly MAX_RANDOM_INTEGER = 281474976710654;
-
- private constructor() {
+ private static readonly SEMVER_PATTERN =
+ '^(0|[1-9]\\d*)\\.(0|[1-9]\\d*)\\.(0|[1-9]\\d*)(?:-((?:0|[1-9]\\d*|\\d*[a-zA-Z-][0-9a-zA-Z-]*)(?:\\.(?:0|[1-9]\\d*|\\d*[a-zA-Z-][0-9a-zA-Z-]*))*))?(?:\\+([0-9a-zA-Z-]+(?:\\.[0-9a-zA-Z-]+)*))?$'
+
+ private static readonly DEFAULT_CHARGING_STATION_RESET_TIME = 30000 // Ms
+
+ static readonly DEFAULT_STATION_INFO: Partial<ChargingStationInfo> = Object.freeze({
+ enableStatistics: false,
+ autoStart: true,
+ remoteAuthorization: true,
+ currentOutType: CurrentType.AC,
+ mainVoltageMeterValues: true,
+ phaseLineToLineVoltageMeterValues: false,
+ customValueLimitationMeterValues: true,
+ ocppStrictCompliance: true,
+ outOfOrderEndMeterValues: false,
+ beginEndMeterValues: false,
+ meteringPerTransaction: true,
+ transactionDataMeterValues: false,
+ supervisionUrlOcppConfiguration: false,
+ supervisionUrlOcppKey: VendorParametersKey.ConnectionUrl,
+ useConnectorId0: true,
+ ocppVersion: OCPPVersion.VERSION_16,
+ firmwareVersionPattern: Constants.SEMVER_PATTERN,
+ firmwareUpgrade: {
+ versionUpgrade: {
+ step: 1
+ },
+ reset: true
+ },
+ ocppPersistentConfiguration: true,
+ stationInfoPersistentConfiguration: true,
+ automaticTransactionGeneratorPersistentConfiguration: true,
+ resetTime: Constants.DEFAULT_CHARGING_STATION_RESET_TIME,
+ autoReconnectMaxRetries: -1,
+ registrationMaxRetries: -1,
+ reconnectExponentialDelay: false,
+ stopTransactionsOnStopped: true
+ })
+
+ static readonly DEFAULT_BOOT_NOTIFICATION_INTERVAL = 60000 // Ms
+ static readonly DEFAULT_HEARTBEAT_INTERVAL = 60000 // Ms
+ static readonly DEFAULT_METER_VALUES_INTERVAL = 60000 // Ms
+
+ static readonly DEFAULT_ATG_WAIT_TIME = 1000 // Ms
+ static readonly DEFAULT_ATG_CONFIGURATION: AutomaticTransactionGeneratorConfiguration =
+ Object.freeze({
+ enable: false,
+ minDuration: 60,
+ maxDuration: 120,
+ minDelayBetweenTwoTransactions: 15,
+ maxDelayBetweenTwoTransactions: 30,
+ probabilityOfStart: 1,
+ stopAfterHours: 0.25,
+ stopAbsoluteDuration: false
+ })
+
+ static readonly DEFAULT_CIRCULAR_BUFFER_CAPACITY = 386
+
+ static readonly DEFAULT_HASH_ALGORITHM = 'sha384'
+
+ static readonly DEFAULT_IDTAG = '00000000'
+
+ static readonly DEFAULT_CONNECTION_TIMEOUT = 30
+
+ static readonly DEFAULT_LOG_STATISTICS_INTERVAL = 60 // Seconds
+
+ static readonly DEFAULT_FLUCTUATION_PERCENT = 5
+
+ static readonly DEFAULT_PERFORMANCE_DIRECTORY = 'performance'
+ static readonly DEFAULT_PERFORMANCE_RECORDS_FILENAME = 'performanceRecords.json'
+ static readonly DEFAULT_PERFORMANCE_RECORDS_DB_NAME = 'e-mobility-charging-stations-simulator'
+ static readonly PERFORMANCE_RECORDS_TABLE = 'performance_records'
+
+ static readonly DEFAULT_UI_SERVER_HOST = 'localhost'
+ static readonly DEFAULT_UI_SERVER_PORT = 8080
+
+ static readonly UNKNOWN_OCPP_COMMAND = 'unknown OCPP command' as
+ | RequestCommand
+ | IncomingRequestCommand
+
+ static readonly MAX_RANDOM_INTEGER = 281474976710655
+
+ static readonly STOP_CHARGING_STATIONS_TIMEOUT = 60000 // Ms
+
+ static readonly EMPTY_FROZEN_OBJECT = Object.freeze({})
+ static readonly EMPTY_FUNCTION = Object.freeze(() => {
+ /* This is intentional */
+ })
+
+ static readonly DEFAULT_MESSAGE_BUFFER_FLUSH_INTERVAL = 60000 // Ms
+
+ private constructor () {
// This is intentional
}
}