fix: strict number check
[e-mobility-charging-stations-simulator.git] / src / utils / Constants.ts
index 2e43d37697d2e47c603d3b5f312f9d54bef12631..c42e15be6e3687f84202f125af61ea966e6ea46a 100644 (file)
@@ -1,65 +1,58 @@
-import { AvailabilityStatus, ChargingProfileStatus, ClearChargingProfileStatus, ConfigurationStatus, DefaultStatus, TriggerMessageStatus, UnlockStatus } from '../types/ocpp/Responses';
-
-import { MeterValueMeasurand } from '../types/ocpp/MeterValues';
-
-export default class Constants {
-  static readonly OCPP_RESPONSE_EMPTY = Object.freeze({});
-  static readonly OCPP_RESPONSE_ACCEPTED = Object.freeze({ status: DefaultStatus.ACCEPTED });
-  static readonly OCPP_RESPONSE_REJECTED = Object.freeze({ status: DefaultStatus.REJECTED });
-  static readonly OCPP_CONFIGURATION_RESPONSE_ACCEPTED = Object.freeze({ status: ConfigurationStatus.ACCEPTED });
-  static readonly OCPP_CONFIGURATION_RESPONSE_REJECTED = Object.freeze({ status: ConfigurationStatus.REJECTED });
-  static readonly OCPP_CONFIGURATION_RESPONSE_REBOOT_REQUIRED = Object.freeze({ status: ConfigurationStatus.REBOOT_REQUIRED });
-  static readonly OCPP_CONFIGURATION_RESPONSE_NOT_SUPPORTED = Object.freeze({ status: ConfigurationStatus.NOT_SUPPORTED });
-  static readonly OCPP_SET_CHARGING_PROFILE_RESPONSE_ACCEPTED = Object.freeze({ status: ChargingProfileStatus.ACCEPTED });
-  static readonly OCPP_SET_CHARGING_PROFILE_RESPONSE_REJECTED = Object.freeze({ status: ChargingProfileStatus.REJECTED });
-  static readonly OCPP_SET_CHARGING_PROFILE_RESPONSE_NOT_SUPPORTED = Object.freeze({ status: ChargingProfileStatus.NOT_SUPPORTED });
-  static readonly OCPP_CLEAR_CHARGING_PROFILE_RESPONSE_ACCEPTED = Object.freeze({ status: ClearChargingProfileStatus.ACCEPTED });
-  static readonly OCPP_CLEAR_CHARGING_PROFILE_RESPONSE_UNKNOWN = Object.freeze({ status: ClearChargingProfileStatus.UNKNOWN });
-  static readonly OCPP_RESPONSE_UNLOCKED = Object.freeze({ status: UnlockStatus.UNLOCKED });
-  static readonly OCPP_RESPONSE_UNLOCK_FAILED = Object.freeze({ status: UnlockStatus.UNLOCK_FAILED });
-  static readonly OCPP_RESPONSE_UNLOCK_NOT_SUPPORTED = Object.freeze({ status: UnlockStatus.NOT_SUPPORTED });
-  static readonly OCPP_AVAILABILITY_RESPONSE_ACCEPTED = Object.freeze({ status: AvailabilityStatus.ACCEPTED });
-  static readonly OCPP_AVAILABILITY_RESPONSE_REJECTED = Object.freeze({ status: AvailabilityStatus.REJECTED });
-  static readonly OCPP_AVAILABILITY_RESPONSE_SCHEDULED = Object.freeze({ status: AvailabilityStatus.SCHEDULED });
-  static readonly OCPP_TRIGGER_MESSAGE_RESPONSE_ACCEPTED = Object.freeze({ status: TriggerMessageStatus.ACCEPTED });
-  static readonly OCPP_TRIGGER_MESSAGE_RESPONSE_REJECTED = Object.freeze({ status: TriggerMessageStatus.REJECTED });
-  static readonly OCPP_TRIGGER_MESSAGE_RESPONSE_NOT_IMPLEMENTED = Object.freeze({ status: TriggerMessageStatus.NOT_IMPLEMENTED });
+import { MeterValueMeasurand } from '../types';
 
+export class Constants {
   static readonly OCPP_DEFAULT_BOOT_NOTIFICATION_INTERVAL = 60000; // Ms
   static readonly OCPP_WEBSOCKET_TIMEOUT = 60000; // Ms
-  static readonly OCPP_TRIGGER_MESSAGE_DELAY = 2000; // Ms
+  static readonly OCPP_TRIGGER_MESSAGE_DELAY = 500; // Ms
 
   static readonly CHARGING_STATION_DEFAULT_RESET_TIME = 60000; // Ms
   static readonly CHARGING_STATION_ATG_INITIALIZATION_TIME = 1000; // Ms
   static readonly CHARGING_STATION_ATG_DEFAULT_STOP_AFTER_HOURS = 0.25; // Hours
 
-  static readonly TRANSACTION_DEFAULT_IDTAG = '00000000';
+  // See https://semver.org/#is-there-a-suggested-regular-expression-regex-to-check-a-semver-string
+  static readonly SEMVER_PATTERN =
+    '^(0|[1-9]\\d*)\\.(0|[1-9]\\d*)\\.(0|[1-9]\\d*)(?:-((?:0|[1-9]\\d*|\\d*[a-zA-Z-][0-9a-zA-Z-]*)(?:\\.(?:0|[1-9]\\d*|\\d*[a-zA-Z-][0-9a-zA-Z-]*))*))?(?:\\+([0-9a-zA-Z-]+(?:\\.[0-9a-zA-Z-]+)*))?$';
 
-  static readonly WORKER_START_DELAY = 500;
-  static readonly WORKER_POOL_MAX_INACTIVE_TIME = 60000;
-  static readonly DEFAULT_WORKER_POOL_MIN_SIZE = 4;
-  static readonly DEFAULT_WORKER_POOL_MAX_SIZE = 16;
-  static readonly DEFAULT_CHARGING_STATIONS_PER_WORKER = 1;
+  static readonly DEFAULT_CIRCULAR_BUFFER_CAPACITY = 1024;
+
+  static readonly DEFAULT_HASH_ALGORITHM = 'sha384';
+
+  static readonly DEFAULT_IDTAG = '00000000';
 
   static readonly DEFAULT_CONNECTION_TIMEOUT = 30;
 
+  static readonly DEFAULT_LOG_STATISTICS_INTERVAL = 60; // Seconds
+
   static readonly DEFAULT_HEARTBEAT_INTERVAL = 60000; // Ms
+  static readonly DEFAULT_METER_VALUES_INTERVAL = 60000; // Ms
 
   static readonly SUPPORTED_MEASURANDS = Object.freeze([
     MeterValueMeasurand.STATE_OF_CHARGE,
     MeterValueMeasurand.VOLTAGE,
     MeterValueMeasurand.POWER_ACTIVE_IMPORT,
     MeterValueMeasurand.CURRENT_IMPORT,
-    MeterValueMeasurand.ENERGY_ACTIVE_IMPORT_REGISTER
+    MeterValueMeasurand.ENERGY_ACTIVE_IMPORT_REGISTER,
   ]);
 
   static readonly DEFAULT_FLUCTUATION_PERCENT = 5;
 
-  static readonly PERFORMANCE_RECORDS_FILETYPE = 'Performance records';
   static readonly DEFAULT_PERFORMANCE_RECORDS_FILENAME = 'performanceRecords.json';
-  static readonly DEFAULT_PERFORMANCE_RECORDS_DB_NAME = 'charging-stations-simulator';
+  static readonly DEFAULT_PERFORMANCE_RECORDS_DB_NAME = 'e-mobility-charging-stations-simulator';
   static readonly PERFORMANCE_RECORDS_TABLE = 'performance_records';
 
-  static readonly DEFAULT_UI_WEBSOCKET_SERVER_HOST = 'localhost';
-  static readonly DEFAULT_UI_WEBSOCKET_SERVER_PORT = 8080;
+  static readonly DEFAULT_UI_SERVER_HOST = 'localhost';
+  static readonly DEFAULT_UI_SERVER_PORT = 8080;
+
+  static readonly UNKNOWN_COMMAND = 'unknown command';
+
+  static readonly MAX_RANDOM_INTEGER = 281474976710654;
+
+  static readonly EMPTY_FREEZED_OBJECT = Object.freeze({});
+  static readonly EMPTY_FUNCTION = Object.freeze(() => {
+    /* This is intentional */
+  });
+
+  private constructor() {
+    // This is intentional
+  }
 }