Switch rollup bundler TS plugin to rollup-plugin-ts
[e-mobility-charging-stations-simulator.git] / src / utils / Constants.ts
index 8b1df1ca31983bbd400ec0a0c039be124de111d4..c83340e4950d36177eb29c358b4b19130f604688 100644 (file)
@@ -1,9 +1,9 @@
-import { AvailabilityStatus, ChargingProfileStatus, ClearChargingProfileStatus, ConfigurationStatus, DefaultStatus, UnlockStatus } from '../types/ocpp/1.6/Responses';
+import { AvailabilityStatus, ChargingProfileStatus, ClearChargingProfileStatus, ConfigurationStatus, DefaultStatus, UnlockStatus } from '../types/ocpp/Responses';
 
-export default class Constants {
-  static readonly ENTITY_CHARGING_STATION = 'ChargingStation';
-  static readonly ENTITY_AUTOMATIC_TRANSACTION_GENERATOR = 'AutomaticTransactionGenerator';
+import { MeterValueMeasurand } from '../types/ocpp/MeterValues';
 
+export default class Constants {
+  static readonly OCPP_RESPONSE_EMPTY = Object.freeze({});
   static readonly OCPP_RESPONSE_ACCEPTED = Object.freeze({ status: DefaultStatus.ACCEPTED });
   static readonly OCPP_RESPONSE_REJECTED = Object.freeze({ status: DefaultStatus.REJECTED });
   static readonly OCPP_CONFIGURATION_RESPONSE_ACCEPTED = Object.freeze({ status: ConfigurationStatus.ACCEPTED });
@@ -23,7 +23,7 @@ export default class Constants {
   static readonly OCPP_AVAILABILITY_RESPONSE_SCHEDULED = Object.freeze({ status: AvailabilityStatus.SCHEDULED });
 
   static readonly OCPP_DEFAULT_BOOT_NOTIFICATION_INTERVAL = 60000; // Ms
-  static readonly OCPP_ERROR_TIMEOUT = 60000; // 60 sec
+  static readonly OCPP_ERROR_TIMEOUT = 60000; // Ms
 
   static readonly CHARGING_STATION_DEFAULT_RESET_TIME = 60000; // Ms
   static readonly CHARGING_STATION_ATG_WAIT_TIME = 2000; // Ms
@@ -33,4 +33,21 @@ export default class Constants {
 
   static readonly WORKER_START_DELAY = 500;
   static readonly WORKER_POOL_MAX_INACTIVE_TIME = 60000;
+  static readonly DEFAULT_WORKER_POOL_MIN_SIZE = 4;
+  static readonly DEFAULT_WORKER_POOL_MAX_SIZE = 16;
+  static readonly DEFAULT_CHARGING_STATIONS_PER_WORKER = 1;
+
+  static readonly DEFAULT_CONNECTION_TIMEOUT = 30;
+
+  static readonly DEFAULT_HEARTBEAT_INTERVAL = 60000; // Ms
+
+  static readonly SUPPORTED_MEASURANDS = Object.freeze([MeterValueMeasurand.STATE_OF_CHARGE, MeterValueMeasurand.VOLTAGE,
+    MeterValueMeasurand.POWER_ACTIVE_IMPORT, MeterValueMeasurand.CURRENT_IMPORT, MeterValueMeasurand.ENERGY_ACTIVE_IMPORT_REGISTER]);
+
+  static readonly DEFAULT_FLUCTUATION_PERCENT = 5;
+
+  static readonly PERFORMANCE_RECORDS_FILETYPE = 'Performance records';
+  static readonly DEFAULT_PERFORMANCE_RECORDS_FILENAME = 'performanceRecords.json';
+  static readonly DEFAULT_PERFORMANCE_RECORDS_DB_NAME = 'charging-stations-simulator';
+  static readonly PERFORMANCE_RECORDS_TABLE = 'performance_records';
 }