X-Git-Url: https://git.piment-noir.org/?a=blobdiff_plain;ds=inline;f=src%2Flib%2FCECProcessor.cpp;h=e9caaf0835ba0cec3a4e83e72fb410541f825f35;hb=d1998c7bd8bb71fac318d555409d8f2c4da255fa;hp=ae7d5fd16b93c1b7ecab70f2b8c784b8234f46b5;hpb=78e8010a91b23bd33c547937870d3240c641815f;p=deb_libcec.git diff --git a/src/lib/CECProcessor.cpp b/src/lib/CECProcessor.cpp index ae7d5fd..e9caaf0 100644 --- a/src/lib/CECProcessor.cpp +++ b/src/lib/CECProcessor.cpp @@ -33,6 +33,7 @@ #include "CECProcessor.h" #include "AdapterCommunication.h" +#include "CECBusDevice.h" #include "LibCEC.h" #include "util/StdString.h" #include "platform/timeutils.h" @@ -41,16 +42,15 @@ using namespace CEC; using namespace std; CCECProcessor::CCECProcessor(CLibCEC *controller, CAdapterCommunication *serComm, const char *strDeviceName, cec_logical_address iLogicalAddress /* = CECDEVICE_PLAYBACKDEVICE1 */, uint16_t iPhysicalAddress /* = CEC_DEFAULT_PHYSICAL_ADDRESS*/) : - m_physicaladdress(iPhysicalAddress), + m_iPhysicalAddress(iPhysicalAddress), m_iLogicalAddress(iLogicalAddress), m_strDeviceName(strDeviceName), m_communication(serComm), - m_controller(controller) + m_controller(controller), + m_bMonitor(false) { - for (uint8_t iPtr = 0; iPtr < 16; iPtr++) - m_vendorIds[iPtr] = CEC_VENDOR_UNKNOWN; - for (uint8_t iPtr = 0; iPtr < 16; iPtr++) - m_vendorClasses[iPtr] = (uint8_t) 0; + for (unsigned int iPtr = 0; iPtr < 16; iPtr++) + m_busDevices[iPtr] = new CCECBusDevice(this, (cec_logical_address) iPtr, 0); } CCECProcessor::~CCECProcessor(void) @@ -58,6 +58,8 @@ CCECProcessor::~CCECProcessor(void) StopThread(); m_communication = NULL; m_controller = NULL; + for (unsigned int iPtr = 0; iPtr < 16; iPtr++) + delete m_busDevices[iPtr]; } bool CCECProcessor::Start(void) @@ -158,8 +160,8 @@ bool CCECProcessor::SetActiveView(void) cec_command command; cec_command::format(command, m_iLogicalAddress, CECDEVICE_BROADCAST, CEC_OPCODE_ACTIVE_SOURCE); - command.parameters.push_back((m_physicaladdress >> 8) & 0xFF); - command.parameters.push_back(m_physicaladdress & 0xFF); + command.parameters.push_back((m_iPhysicalAddress >> 8) & 0xFF); + command.parameters.push_back(m_iPhysicalAddress & 0xFF); return Transmit(command); } @@ -173,8 +175,8 @@ bool CCECProcessor::SetInactiveView(void) cec_command command; cec_command::format(command, m_iLogicalAddress, CECDEVICE_BROADCAST, CEC_OPCODE_INACTIVE_SOURCE); - command.parameters.push_back((m_physicaladdress >> 8) & 0xFF); - command.parameters.push_back(m_physicaladdress & 0xFF); + command.parameters.push_back((m_iPhysicalAddress >> 8) & 0xFF); + command.parameters.push_back(m_iPhysicalAddress & 0xFF); return Transmit(command); } @@ -183,10 +185,10 @@ void CCECProcessor::LogOutput(const cec_command &data) { CStdString txStr = "transmit "; txStr.AppendFormat(" %02x", ((uint8_t)data.initiator << 4) + (uint8_t)data.destination); - txStr.AppendFormat(" %02x", (uint8_t)data.opcode); + txStr.AppendFormat(":%02x", (uint8_t)data.opcode); for (uint8_t iPtr = 0; iPtr < data.parameters.size; iPtr++) - txStr.AppendFormat(" %02x", data.parameters[iPtr]); + txStr.AppendFormat(":%02x", data.parameters[iPtr]); m_controller->AddLog(CEC_LOG_DEBUG, txStr.c_str()); } @@ -204,13 +206,52 @@ bool CCECProcessor::Transmit(const cec_command &data, bool bWaitForAck /* = true bool CCECProcessor::SetLogicalAddress(cec_logical_address iLogicalAddress) { CStdString strLog; - strLog.Format("<< setting logical address to %d", iLogicalAddress); + strLog.Format("<< setting logical address to %1x", iLogicalAddress); m_controller->AddLog(CEC_LOG_NOTICE, strLog.c_str()); m_iLogicalAddress = iLogicalAddress; return m_communication && m_communication->SetAckMask(0x1 << (uint8_t)m_iLogicalAddress); } +bool CCECProcessor::SetPhysicalAddress(uint16_t iPhysicalAddress) +{ + CStdString strLog; + strLog.Format("<< setting physical address to %2x", iPhysicalAddress); + m_controller->AddLog(CEC_LOG_NOTICE, strLog.c_str()); + + m_iPhysicalAddress = iPhysicalAddress; + return SetActiveView(); +} + +bool CCECProcessor::SetOSDString(cec_logical_address iLogicalAddress, cec_display_control duration, const char *strMessage) +{ + CStdString strLog; + strLog.Format("<< display message '%s'", strMessage); + m_controller->AddLog(CEC_LOG_NOTICE, strLog.c_str()); + + cec_command command; + cec_command::format(command, m_iLogicalAddress, iLogicalAddress, CEC_OPCODE_SET_OSD_STRING); + command.parameters.push_back((uint8_t)duration); + + for (unsigned int iPtr = 0; iPtr < strlen(strMessage); iPtr++) + command.parameters.push_back(strMessage[iPtr]); + + return Transmit(command); +} + +bool CCECProcessor::SwitchMonitoring(bool bEnable) +{ + CStdString strLog; + strLog.Format("== %s monitoring mode ==", bEnable ? "enabling" : "disabling"); + m_controller->AddLog(CEC_LOG_NOTICE, strLog.c_str()); + + m_bMonitor = bEnable; + if (bEnable) + return m_communication && m_communication->SetAckMask(0); + else + return m_communication && m_communication->SetAckMask(0x1 << (uint8_t)m_iLogicalAddress); +} + bool CCECProcessor::TransmitFormatted(const cec_adapter_message &data, bool bWaitForAck /* = true */) { CLockObject lock(&m_mutex); @@ -316,13 +357,13 @@ void CCECProcessor::ReportOSDName(cec_logical_address address /* = CECDEVICE_TV void CCECProcessor::ReportPhysicalAddress(void) { CStdString strLog; - strLog.Format("<< reporting physical address as %04x", m_physicaladdress); + strLog.Format("<< reporting physical address as %04x", m_iPhysicalAddress); m_controller->AddLog(CEC_LOG_NOTICE, strLog.c_str()); cec_command command; cec_command::format(command, m_iLogicalAddress, CECDEVICE_BROADCAST, CEC_OPCODE_REPORT_PHYSICAL_ADDRESS); - command.parameters.push_back((uint8_t) ((m_physicaladdress >> 8) & 0xFF)); - command.parameters.push_back((uint8_t) (m_physicaladdress & 0xFF)); + command.parameters.push_back((uint8_t) ((m_iPhysicalAddress >> 8) & 0xFF)); + command.parameters.push_back((uint8_t) (m_iPhysicalAddress & 0xFF)); command.parameters.push_back((uint8_t) (CEC_DEVICE_TYPE_PLAYBACK_DEVICE)); Transmit(command); @@ -334,8 +375,8 @@ void CCECProcessor::BroadcastActiveSource(void) cec_command command; cec_command::format(command, m_iLogicalAddress, CECDEVICE_BROADCAST, CEC_OPCODE_ACTIVE_SOURCE); - command.parameters.push_back((uint8_t) ((m_physicaladdress >> 8) & 0xFF)); - command.parameters.push_back((uint8_t) (m_physicaladdress & 0xFF)); + command.parameters.push_back((uint8_t) ((m_iPhysicalAddress >> 8) & 0xFF)); + command.parameters.push_back((uint8_t) (m_iPhysicalAddress & 0xFF)); Transmit(command); } @@ -493,117 +534,37 @@ void CCECProcessor::ParseVendorId(cec_logical_address device, const cec_datapack ((uint64_t)data[1] << 2) + (uint64_t)data[2]; - m_vendorIds[(uint8_t)device] = iVendorId; - m_vendorClasses[(uint8_t)device] = data.size >= 4 ? data[3] : 0; - - CStdString strLog; - strLog.Format("device %d: vendor = %s (%lld) class = %2x", (uint8_t)device, CECVendorIdToString(m_vendorIds[(uint8_t)device]), iVendorId, m_vendorClasses[(uint8_t)device]); - m_controller->AddLog(CEC_LOG_DEBUG, strLog.c_str()); + m_busDevices[(uint8_t)device]->SetVendorId(iVendorId, data.size >= 4 ? data[3] : 0); } void CCECProcessor::ParseCommand(cec_command &command) { CStdString dataStr; - dataStr.Format(">> received frame: initiator: %u destination: %u", command.initiator, command.destination); - if (command.parameters.size > 1) - { - dataStr += " data:"; - for (uint8_t iPtr = 0; iPtr < command.parameters.size; iPtr++) - dataStr.AppendFormat(" %02x", (unsigned int)command.parameters[iPtr]); - } + dataStr.Format(">> received frame: %1x%1x:%02x", command.initiator, command.destination, command.opcode); + for (uint8_t iPtr = 0; iPtr < command.parameters.size; iPtr++) + dataStr.AppendFormat(":%02x", (unsigned int)command.parameters[iPtr]); m_controller->AddLog(CEC_LOG_DEBUG, dataStr.c_str()); - if (command.destination == m_iLogicalAddress) - { - switch(command.opcode) - { - case CEC_OPCODE_GIVE_PHYSICAL_ADDRESS: - ReportPhysicalAddress(); - break; - case CEC_OPCODE_GIVE_OSD_NAME: - ReportOSDName(command.initiator); - break; - case CEC_OPCODE_GIVE_DEVICE_VENDOR_ID: - ReportVendorID(command.initiator); - break; - case CEC_OPCODE_VENDOR_COMMAND_WITH_ID: - ParseVendorId(command.initiator, command.parameters); - TransmitAbort(command.initiator, CEC_OPCODE_VENDOR_COMMAND_WITH_ID); - break; - case CEC_OPCODE_GIVE_DECK_STATUS: - // need to support opcodes play and deck control before doing anything with this - TransmitAbort(command.initiator, CEC_OPCODE_GIVE_DECK_STATUS); - break; - case CEC_OPCODE_MENU_REQUEST: - if (command.parameters[0] == CEC_MENU_REQUEST_TYPE_QUERY) - ReportMenuState(command.initiator); - break; - case CEC_OPCODE_GIVE_DEVICE_POWER_STATUS: - ReportPowerState(command.initiator); - break; - case CEC_OPCODE_GET_CEC_VERSION: - ReportCECVersion(command.initiator); - break; - case CEC_OPCODE_USER_CONTROL_PRESSED: - if (command.parameters.size > 0) - { - m_controller->AddKey(); + if (!m_bMonitor) + m_busDevices[(uint8_t)command.initiator]->HandleCommand(command); +} - if (command.parameters[0] <= CEC_USER_CONTROL_CODE_MAX) - m_controller->SetCurrentButton((cec_user_control_code) command.parameters[0]); - } - break; - case CEC_OPCODE_USER_CONTROL_RELEASE: - m_controller->AddKey(); - break; - case CEC_OPCODE_ROUTING_CHANGE: - m_controller->SetActiveView(); - break; - default: - m_controller->AddCommand(command); - break; - } - } - else if (command.destination == CECDEVICE_BROADCAST) - { - CStdString strLog; - if (command.opcode == CEC_OPCODE_REQUEST_ACTIVE_SOURCE) - { - strLog.Format(">> %i requests active source", (uint8_t) command.initiator); - m_controller->AddLog(CEC_LOG_DEBUG, strLog.c_str()); - BroadcastActiveSource(); - } - else if (command.opcode == CEC_OPCODE_SET_STREAM_PATH) - { - if (command.parameters.size >= 2) - { - int streamaddr = ((int)command.parameters[0] << 8) | ((int)command.parameters[1]); - strLog.Format(">> %i requests stream path from physical address %04x", command.initiator, streamaddr); - m_controller->AddLog(CEC_LOG_DEBUG, strLog.c_str()); - if (streamaddr == m_physicaladdress) - BroadcastActiveSource(); - } - } - else - { - m_controller->AddCommand(command); - } - } - else - { - CStdString strLog; - strLog.Format("ignoring frame: destination: %u != %u", command.destination, (uint8_t)m_iLogicalAddress); - m_controller->AddLog(CEC_LOG_DEBUG, strLog.c_str()); - } +void CCECProcessor::SetCurrentButton(cec_user_control_code iButtonCode) +{ + m_controller->SetCurrentButton(iButtonCode); } -const char *CCECProcessor::CECVendorIdToString(const uint64_t iVendorId) +void CCECProcessor::AddCommand(const cec_command &command) { - switch (iVendorId) - { - case CEC_VENDOR_SAMSUNG: - return "Samsung"; - default: - return "Unknown"; - } + m_controller->AddCommand(command); +} + +void CCECProcessor::AddKey(void) +{ + m_controller->AddKey(); +} + +void CCECProcessor::AddLog(cec_log_level level, const CStdString &strMessage) +{ + m_controller->AddLog(level, strMessage); }