X-Git-Url: https://git.piment-noir.org/?a=blobdiff_plain;f=README.md;h=18cdd32ef6186862bf41db87b5623032b639bedc;hb=59395dc149654128f2996f4999bccb66270f54e4;hp=9df920327a89b9cd24225867609309707ffbc574;hpb=fd4053484519bcc6580ccf2935a5e5a14fe976bf;p=e-mobility-charging-stations-simulator.git diff --git a/README.md b/README.md index 9df92032..18cdd32e 100644 --- a/README.md +++ b/README.md @@ -96,10 +96,11 @@ But the modifications to test have to be done to the files in the build target d | supervisionUrlDistribution | round-robin/random/charging-station-affinity | charging-station-affinity | boolean | supervision urls distribution policy to simulated charging stations | | logStatisticsInterval | | 60 | integer | seconds between charging stations statistics output in the logs | | logConsole | true/false | false | boolean | output logs on the console | -| logFormat | | simple | string | winston log format | +| logFormat | | simple | string | [winston](https://github.com/winstonjs/winston) log format | | logRotate | true/false | true | boolean | enable daily log files rotation | -| logMaxFiles | | 7 | integer | maximum number of log files to keep | -| logLevel | emerg/alert/crit/error/warning/notice/info/debug | info | string | winston logging level | +| logMaxFiles | x/"xd" where x is an integer | undefined | integer \| string | maximum number of log files | +| logMaxSize | x/"xk"/"xm"/"xg" where x is a number | undefined | number \| string | maximum size of log files in bytes, or units of kb, mb, and gb | +| logLevel | emerg/alert/crit/error/warning/notice/info/debug | info | string | [winston](https://github.com/winstonjs/winston) logging level | | logFile | | combined.log | string | log file relative path | | logErrorFile | | error.log | string | error log file relative path | | worker | | {
"processType": "workerSet",
"startDelay": 500,
"elementStartDelay": 0,
"elementsPerWorker": 1,
"poolMinSize": 4,
"poolMaxSize": 16,
"poolStrategy": "ROUND_ROBIN"
} | {
processType: WorkerProcessType;
startDelay: number;
elementStartDelay: number;
elementsPerWorker: number;
poolMinSize: number;
poolMaxSize: number;
poolStrategy: WorkerChoiceStrategy;
} | Worker configuration section:
- processType: worker threads process type (workerSet/staticPool/dynamicPool)
- startDelay: milliseconds to wait at worker threads startup (only for workerSet threads process type)
- elementStartDelay: milliseconds to wait at charging station startup
- elementsPerWorker: number of charging stations per worker threads for the `workerSet` process type
- poolMinSize: worker threads pool minimum number of threads
- poolMaxSize: worker threads pool maximum number of threads
- poolStrategy: worker threads pool [poolifier](https://github.com/poolifier/poolifier) worker choice strategy | @@ -122,59 +123,61 @@ But the modifications to test have to be done to the files in the build target d **src/assets/station-templates/\.json**: -| Key | Value(s) | Default Value | Value type | Description | -| ---------------------------------- | ---------- | ----------------------------------------------------------------- | ---------------------------------------------------------------------------------------------------------------------------------- | ----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------- | -| supervisionUrls | | '' | string \| string[] | string or array of connection URIs to OCPP-J servers | -| supervisionUser | | '' | string | basic HTTP authentication user to OCPP-J server | -| supervisionPassword | | '' | string | basic HTTP authentication password to OCPP-J server | -| supervisionUrlOcppConfiguration | true/false | false | boolean | allow supervision URL configuration via a vendor OCPP parameter key | -| supervisionUrlOcppKey | | 'ConnectionUrl' | string | the vendor string that will be used as a vendor OCPP parameter key to set the supervision URL | -| ocppVersion | 1.6 | 1.6 | string | OCPP version | -| ocppProtocol | json | json | string | OCPP protocol | -| ocppStrictCompliance | true/false | false | boolean | strict adherence to the OCPP version and protocol specifications | -| ocppPersistentConfiguration | true/false | true | boolean | enable persistent OCPP parameters storage by charging stations 'hashId'. The persistency is ensured by the charging stations configuration files in dist/assets/configurations | -| stationInfoPersistentConfiguration | true/false | true | boolean | enable persistent station information and specifications storage by charging stations 'hashId'. The persistency is ensured by the charging stations configuration files in dist/assets/configurations | -| wsOptions | | {} | ClientOptions & ClientRequestArgs | [ws](https://github.com/websockets/ws) and node.js [http](https://nodejs.org/api/http.html) clients options intersection | -| authorizationFile | | '' | string | RFID tags list file relative to src/assets path | -| baseName | | '' | string | base name to build charging stations id | -| nameSuffix | | '' | string | name suffix to build charging stations id | -| fixedName | true/false | false | boolean | use the baseName as the charging stations unique name | -| chargePointModel | | '' | string | charging stations model | -| chargePointVendor | | '' | string | charging stations vendor | -| chargePointSerialNumberPrefix | | '' | string | charge point serial number prefix | -| chargeBoxSerialNumberPrefix | | '' | string | charge box serial number prefix (deprecated in OCPP 1.6) | -| firmwareVersion | | '' | string | charging stations firmware version | -| power | | | float \| float[] | charging stations maximum power value(s) | -| powerSharedByConnectors | true/false | false | boolean | charging stations power shared by its connectors | -| powerUnit | W/kW | W | string | charging stations power unit | -| currentOutType | AC/DC | AC | string | charging stations current out type | -| voltageOut | | AC:230/DC:400 | integer | charging stations voltage out | -| numberOfPhases | 0/1/3 | AC:3/DC:0 | integer | charging stations number of phase(s) | -| numberOfConnectors | | | integer \| integer[] | charging stations number of connector(s) | -| useConnectorId0 | true/false | true | boolean | use connector id 0 definition from the charging station configuration template | -| randomConnectors | true/false | false | boolean | randomize runtime connector id affectation from the connector id definition in charging station configuration template | -| resetTime | | 60 | integer | seconds to wait before the charging stations come back at reset | -| autoRegister | true/false | false | boolean | set charging stations as registered at boot notification for testing purpose | -| autoReconnectMaxRetries | | -1 (unlimited) | integer | connection retries to the OCPP-J server | -| reconnectExponentialDelay | true/false | false | boolean | connection delay retry to the OCPP-J server | -| registrationMaxRetries | | -1 (unlimited) | integer | charging stations boot notification retries | -| amperageLimitationOcppKey | | undefined | string | charging stations OCPP parameter key used to set the amperage limit, per phase for each connector on AC and global for DC | -| amperageLimitationUnit | A/cA/dA/mA | A | string | charging stations amperage limit unit | -| enableStatistics | true/false | true | boolean | enable charging stations statistics | -| mustAuthorizeAtRemoteStart | true/false | true | boolean | always send authorize at remote start transaction when AuthorizeRemoteTxRequests is enabled | -| payloadSchemaValidation | true/false | true | boolean | validate OCPP commands PDU against [OCA](https://www.openchargealliance.org/) JSON schemas | -| beginEndMeterValues | true/false | false | boolean | enable Transaction.{Begin,End} MeterValues | -| outOfOrderEndMeterValues | true/false | false | boolean | send Transaction.End MeterValues out of order. Need to relax OCPP specifications strict compliance ('ocppStrictCompliance' parameter) | -| meteringPerTransaction | true/false | true | boolean | enable metering history on a per transaction basis | -| transactionDataMeterValues | true/false | false | boolean | enable transaction data MeterValues at stop transaction | -| mainVoltageMeterValues | true/false | true | boolean | include charging stations main voltage MeterValues on three phased charging stations | -| phaseLineToLineVoltageMeterValues | true/false | true | boolean | include charging stations line to line voltage MeterValues on three phased charging stations | -| customValueLimitationMeterValues | true/false | true | boolean | enable limitation on custom fluctuated value in MeterValues | -| commandsSupport | | {
"incomingCommands": {},
"outgoingCommands": {}
} | {
incomingCommands: Record;
outgoingCommands?: Record;
} | Configuration section for OCPP commands support. Empty section or subsections means all implemented OCPP commands are supported | -| messageTriggerSupport | | {} | Record | Configuration section for OCPP commands trigger support. Empty section means all implemented OCPP trigger commands are supported | -| Configuration | | | ChargingStationConfiguration | charging stations OCPP parameters configuration section | -| AutomaticTransactionGenerator | | | AutomaticTransactionGenerator | charging stations ATG configuration section | -| Connectors | | | Connectors | charging stations connectors configuration section | +| Key | Value(s) | Default Value | Value type | Description | +| ---------------------------------- | ------------- | ----------------------------------------------------------------------------------------------------------------------------------- | ---------------------------------------------------------------------------------------------------------------------------------------------- | ----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------- | +| supervisionUrls | | [] | string \| string[] | string or array of connection URIs to OCPP-J servers | +| supervisionUser | | undefined | string | basic HTTP authentication user to OCPP-J server | +| supervisionPassword | | undefined | string | basic HTTP authentication password to OCPP-J server | +| supervisionUrlOcppConfiguration | true/false | false | boolean | allow supervision URL configuration via a vendor OCPP parameter key | +| supervisionUrlOcppKey | | 'ConnectionUrl' | string | the vendor string that will be used as a vendor OCPP parameter key to set the supervision URL | +| ocppVersion | 1.6/2.0/2.0.1 | 1.6 | string | OCPP version | +| ocppProtocol | json | json | string | OCPP protocol | +| ocppStrictCompliance | true/false | false | boolean | strict adherence to the OCPP version and protocol specifications | +| ocppPersistentConfiguration | true/false | true | boolean | enable persistent OCPP parameters storage by charging stations 'hashId'. The persistency is ensured by the charging stations configuration files in [dist/assets/configurations](dist/assets/configurations) | +| stationInfoPersistentConfiguration | true/false | true | boolean | enable persistent station information and specifications storage by charging stations 'hashId'. The persistency is ensured by the charging stations configuration files in [dist/assets/configurations](dist/assets/configurations) | +| wsOptions | | {} | ClientOptions & ClientRequestArgs | [ws](https://github.com/websockets/ws) and node.js [http](https://nodejs.org/api/http.html) clients options intersection | +| authorizationFile | | undefined | string | RFID tags list file relative to src/assets path | +| baseName | | undefined | string | base name to build charging stations id | +| nameSuffix | | undefined | string | name suffix to build charging stations id | +| fixedName | true/false | false | boolean | use the baseName as the charging stations unique name | +| chargePointModel | | undefined | string | charging stations model | +| chargePointVendor | | undefined | string | charging stations vendor | +| chargePointSerialNumberPrefix | | undefined | string | charge point serial number prefix | +| chargeBoxSerialNumberPrefix | | undefined | string | charge box serial number prefix (deprecated in OCPP 1.6) | +| firmwareVersionPattern | | Semantic versionning regular expression: https://semver.org/#is-there-a-suggested-regular-expression-regex-to-check-a-semver-string | string | charging stations firmware version pattern | +| firmwareVersion | | undefined | string | charging stations firmware version | +| power | | | float \| float[] | charging stations maximum power value(s) | +| powerSharedByConnectors | true/false | false | boolean | charging stations power shared by its connectors | +| powerUnit | W/kW | W | string | charging stations power unit | +| currentOutType | AC/DC | AC | string | charging stations current out type | +| voltageOut | | AC:230/DC:400 | integer | charging stations voltage out | +| numberOfPhases | 0/1/3 | AC:3/DC:0 | integer | charging stations number of phase(s) | +| numberOfConnectors | | | integer \| integer[] | charging stations number of connector(s) | +| useConnectorId0 | true/false | true | boolean | use connector id 0 definition from the charging station configuration template | +| randomConnectors | true/false | false | boolean | randomize runtime connector id affectation from the connector id definition in charging station configuration template | +| resetTime | | 60 | integer | seconds to wait before the charging stations come back at reset | +| autoRegister | true/false | false | boolean | set charging stations as registered at boot notification for testing purpose | +| autoReconnectMaxRetries | | -1 (unlimited) | integer | connection retries to the OCPP-J server | +| reconnectExponentialDelay | true/false | false | boolean | connection delay retry to the OCPP-J server | +| registrationMaxRetries | | -1 (unlimited) | integer | charging stations boot notification retries | +| amperageLimitationOcppKey | | undefined | string | charging stations OCPP parameter key used to set the amperage limit, per phase for each connector on AC and global for DC | +| amperageLimitationUnit | A/cA/dA/mA | A | string | charging stations amperage limit unit | +| enableStatistics | true/false | false | boolean | enable charging stations statistics | +| mustAuthorizeAtRemoteStart | true/false | true | boolean | always send authorize at remote start transaction when AuthorizeRemoteTxRequests is enabled | +| payloadSchemaValidation | true/false | true | boolean | validate OCPP commands PDU against [OCA](https://www.openchargealliance.org/) JSON schemas | +| beginEndMeterValues | true/false | false | boolean | enable Transaction.{Begin,End} MeterValues | +| outOfOrderEndMeterValues | true/false | false | boolean | send Transaction.End MeterValues out of order. Need to relax OCPP specifications strict compliance ('ocppStrictCompliance' parameter) | +| meteringPerTransaction | true/false | true | boolean | enable metering history on a per transaction basis | +| transactionDataMeterValues | true/false | false | boolean | enable transaction data MeterValues at stop transaction | +| mainVoltageMeterValues | true/false | true | boolean | include charging stations main voltage MeterValues on three phased charging stations | +| phaseLineToLineVoltageMeterValues | true/false | true | boolean | include charging stations line to line voltage MeterValues on three phased charging stations | +| customValueLimitationMeterValues | true/false | true | boolean | enable limitation on custom fluctuated value in MeterValues | +| firmwareUpgrade | | {
"reset": true
} | {
versionUpgrade: {
patternGroup: number;
step: number;
};
reset: boolean;
failureStatus: FirmwareStatus;
} | Configuration section for simulating firmware upgrade support. | +| commandsSupport | | {
"incomingCommands": {},
"outgoingCommands": {}
} | {
incomingCommands: Record;
outgoingCommands?: Record;
} | Configuration section for OCPP commands support. Empty section or subsections means all implemented OCPP commands are supported | +| messageTriggerSupport | | {} | Record | Configuration section for OCPP commands trigger support. Empty section means all implemented OCPP trigger commands are supported | +| Configuration | | | ChargingStationConfiguration | charging stations OCPP parameters configuration section | +| AutomaticTransactionGenerator | | | AutomaticTransactionGenerator | charging stations ATG configuration section | +| Connectors | | | Connectors | charging stations connectors configuration section | #### Configuration section @@ -326,8 +329,8 @@ make SUBMODULES_INIT=true - :white_check_mark: GetDiagnostics - :white_check_mark: DiagnosticsStatusNotification -- :x: FirmwareStatusNotification -- :x: UpdateFirmware +- :white_check_mark: FirmwareStatusNotification +- :white_check_mark: UpdateFirmware #### Local Auth List Management Profile @@ -411,7 +414,7 @@ Protocol to control the simulator via a Websocket or HTTP server. ### HTTP Protocol -To learn how to use the HTTP protocol to pilot the simulator, an [Insomnia](https://insomnia.rest/) requests collection is available in [src/assets/ui-protocol](./src/assets/ui-protocol) directory. +To learn how to use the HTTP protocol to pilot the simulator, an [Insomnia](https://insomnia.rest/) HTTP requests collection is available in [src/assets/ui-protocol](./src/assets/ui-protocol) directory. ### Websocket Protocol @@ -428,6 +431,8 @@ SRPC protocol over Websocket. PDU stands for 'Protocol Data Unit'. `uuid`: String uniquely linking the response to the request `PDU`: Response parameters to requested procedure +An [Insomnia](https://insomnia.rest/) WebSocket requests collection is available in [src/assets/ui-protocol](./src/assets/ui-protocol) directory. + #### Version 0.0.1 Set the Websocket header _Sec-Websocket-Protocol_ to `ui0.0.1`.