X-Git-Url: https://git.piment-noir.org/?a=blobdiff_plain;f=README.md;h=9ceca281e6310b84196e58e39a8135eb0f689535;hb=b6c7cd21424c1daec0d11933a4c457bc3d97524d;hp=cec08120b78d5bee9740173942f69bcc4819a532;hpb=9e1b12e45e39c041e57442b641c8f1107ec3f8b3;p=e-mobility-charging-stations-simulator.git diff --git a/README.md b/README.md index cec08120..9ceca281 100644 --- a/README.md +++ b/README.md @@ -53,10 +53,11 @@ chargePointModel | | '' | string | charging stations model chargePointVendor | | '' | string | charging stations vendor chargeBoxSerialNumberPrefix | | '' | string | charging stations serial number prefix firmwareVersion | | '' | string | charging stations firmware version -power | | | integer\|integer[] | charging stations maximum power value(s) +power | | | float\|float[] | charging stations maximum power value(s) powerSharedByConnectors | true/false | false | boolean | charging stations power shared by its connectors powerUnit | W/kW | W | string | charging stations power unit currentOutType | AC/DC | AC | string | charging stations current out type +voltageOut | | AC:230/DC:400 | integer | charging stations voltage out numberOfPhases | 0/1/3 | AC:3/DC:0 | integer | charging stations number of phase(s) numberOfConnectors | | | integer\|integer[] | charging stations number of connector(s) useConnectorId0 | true/false | true | boolean | use connector id 0 definition from the template @@ -66,8 +67,11 @@ connectionTimeout | | 30 | integer | connection timeout to the OCPP-J server autoReconnectMaxRetries | | -1 (unlimited) | integer | connection retries to the OCPP-J server reconnectExponentialDelay | true/false | false | boolean | connection delay retry to the OCPP-J server registrationMaxRetries | | -1 (unlimited) | integer | charging stations boot notification retries -enableStatistics | true/false | true | boolean | enable charging stations statistics -voltageOut | | AC:230/DC:400 | integer | charging stations voltage out +enableStatistics | true/false | true | boolean | enable charging stations statistics +beginEndMeterValues | true/false | false | boolean | enable Transaction.{Begin,End} MeterValues +outOfOrderEndMeterValues | true/false | false | boolean | send Transaction.End MeterValues out of order +meteringPerTransaction | true/false | true | boolean | disable metering on a per transaction basis +transactionDataMeterValues | true/false | false | boolean | enable transaction data MeterValues at stop transaction Configuration | | | ChargingStationConfiguration | charging stations OCPP configuration parameters AutomaticTransactionGenerator | | | AutomaticTransactionGenerator | charging stations ATG configuration Connectors | | | Connectors | charging stations connectors configuration @@ -110,7 +114,7 @@ Connectors | | | Connectors | charging stations connectors configuration "probabilityOfStart": 1, "stopAfterHours": 0.3, "stopOnConnectionFailure": true, - "requireAuthorize": false + "requireAuthorize": true } ``` #### Connectors section