X-Git-Url: https://git.piment-noir.org/?a=blobdiff_plain;f=src%2Flib%2Fdevices%2FCECBusDevice.cpp;h=9e9145c0e76af2f4b2abcd70c60182f189166722;hb=2b2767288398d6cdcbe1201a8b52ef515a5f6591;hp=6279de948712b051e1dd4d2d7eaffa61a2a72380;hpb=6c3b011128c09d0c95e498d192ffe2ff88118acc;p=deb_libcec.git diff --git a/src/lib/devices/CECBusDevice.cpp b/src/lib/devices/CECBusDevice.cpp index 6279de9..9e9145c 100644 --- a/src/lib/devices/CECBusDevice.cpp +++ b/src/lib/devices/CECBusDevice.cpp @@ -50,11 +50,13 @@ CCECBusDevice::CCECBusDevice(CCECProcessor *processor, cec_logical_address iLogi m_powerStatus(CEC_POWER_STATUS_UNKNOWN), m_processor(processor), m_vendor(CEC_VENDOR_UNKNOWN), + m_bReplaceHandler(false), m_menuState(CEC_MENU_STATE_ACTIVATED), m_bActiveSource(false), m_iLastActive(0), m_cecVersion(CEC_VERSION_UNKNOWN), - m_deviceStatus(CEC_DEVICE_STATUS_UNKNOWN) + m_deviceStatus(CEC_DEVICE_STATUS_UNKNOWN), + m_handlerMutex(false) { m_handler = new CCECCommandHandler(this); @@ -117,7 +119,7 @@ bool CCECBusDevice::PowerOn(void) strLog.Format("<< powering on '%s' (%X)", GetLogicalAddressName(), m_iLogicalAddress); AddLog(CEC_LOG_DEBUG, strLog.c_str()); - if (m_handler->TransmitPowerOn(GetMyLogicalAddress(), m_iLogicalAddress)) + if (m_handler->TransmitImageViewOn(GetMyLogicalAddress(), m_iLogicalAddress)) { { CLockObject lock(&m_mutex); @@ -154,24 +156,33 @@ bool CCECBusDevice::Standby(void) //@{ cec_version CCECBusDevice::GetCecVersion(bool bUpdate /* = false */) { - CLockObject lock(&m_mutex); - if (GetStatus() == CEC_DEVICE_STATUS_PRESENT && - (bUpdate || m_cecVersion == CEC_VERSION_UNKNOWN)) + bool bRequestUpdate(false); + { + CLockObject lock(&m_mutex); + bRequestUpdate = (GetStatus() == CEC_DEVICE_STATUS_PRESENT && + (bUpdate || m_cecVersion == CEC_VERSION_UNKNOWN)); + } + + if (bRequestUpdate) RequestCecVersion(); + CLockObject lock(&m_mutex); return m_cecVersion; } bool CCECBusDevice::RequestCecVersion(void) { bool bReturn(false); + if (!MyLogicalAddressContains(m_iLogicalAddress)) { + m_handler->MarkBusy(); CStdString strLog; strLog.Format("<< requesting CEC version of '%s' (%X)", GetLogicalAddressName(), m_iLogicalAddress); AddLog(CEC_LOG_NOTICE, strLog); bReturn = m_handler->TransmitRequestCecVersion(GetMyLogicalAddress(), m_iLogicalAddress); + m_handler->MarkReady(); } return bReturn; } @@ -183,28 +194,43 @@ const char* CCECBusDevice::GetLogicalAddressName(void) const cec_menu_language &CCECBusDevice::GetMenuLanguage(bool bUpdate /* = false */) { - CLockObject lock(&m_mutex); - if (GetStatus() == CEC_DEVICE_STATUS_PRESENT && - (bUpdate || !strcmp(m_menuLanguage.language, "???"))) + bool bRequestUpdate(false); + { + CLockObject lock(&m_mutex); + bRequestUpdate = (GetStatus() == CEC_DEVICE_STATUS_PRESENT && + (bUpdate || !strcmp(m_menuLanguage.language, "???"))); + } + + if (bRequestUpdate) RequestMenuLanguage(); + CLockObject lock(&m_mutex); return m_menuLanguage; } bool CCECBusDevice::RequestMenuLanguage(void) { bool bReturn(false); + if (!MyLogicalAddressContains(m_iLogicalAddress) && !IsUnsupportedFeature(CEC_OPCODE_GET_MENU_LANGUAGE)) { + m_handler->MarkBusy(); CStdString strLog; strLog.Format("<< requesting menu language of '%s' (%X)", GetLogicalAddressName(), m_iLogicalAddress); AddLog(CEC_LOG_NOTICE, strLog); bReturn = m_handler->TransmitRequestMenuLanguage(GetMyLogicalAddress(), m_iLogicalAddress); + m_handler->MarkReady(); } return bReturn; } +cec_menu_state CCECBusDevice::GetMenuState(void) +{ + CLockObject lock(&m_mutex); + return m_menuState; +} + cec_logical_address CCECBusDevice::GetMyLogicalAddress(void) const { return m_processor->GetLogicalAddress(); @@ -217,98 +243,134 @@ uint16_t CCECBusDevice::GetMyPhysicalAddress(void) const CStdString CCECBusDevice::GetOSDName(bool bUpdate /* = false */) { - CLockObject lock(&m_mutex); - if (GetStatus() == CEC_DEVICE_STATUS_PRESENT && - (bUpdate || m_strDeviceName.Equals(ToString(m_iLogicalAddress))) && - m_type != CEC_DEVICE_TYPE_TV) + bool bRequestUpdate(false); + { + CLockObject lock(&m_mutex); + bRequestUpdate = (GetStatus() == CEC_DEVICE_STATUS_PRESENT && + (bUpdate || m_strDeviceName.Equals(ToString(m_iLogicalAddress))) && + m_type != CEC_DEVICE_TYPE_TV); + } + + if (bRequestUpdate) RequestOSDName(); + CLockObject lock(&m_mutex); return m_strDeviceName; } bool CCECBusDevice::RequestOSDName(void) { bool bReturn(false); + if (!MyLogicalAddressContains(m_iLogicalAddress) && !IsUnsupportedFeature(CEC_OPCODE_GIVE_OSD_NAME)) { + m_handler->MarkBusy(); CStdString strLog; strLog.Format("<< requesting OSD name of '%s' (%X)", GetLogicalAddressName(), m_iLogicalAddress); AddLog(CEC_LOG_NOTICE, strLog); bReturn = m_handler->TransmitRequestOSDName(GetMyLogicalAddress(), m_iLogicalAddress); + m_handler->MarkReady(); } return bReturn; } uint16_t CCECBusDevice::GetPhysicalAddress(bool bUpdate /* = false */) { - CLockObject lock(&m_mutex); - if (GetStatus() == CEC_DEVICE_STATUS_PRESENT && - (m_iPhysicalAddress == 0xFFFF || bUpdate)) + bool bRequestUpdate(false); { - if (!RequestPhysicalAddress()) - AddLog(CEC_LOG_ERROR, "failed to request the physical address"); + CLockObject lock(&m_mutex); + bRequestUpdate = (GetStatus() == CEC_DEVICE_STATUS_PRESENT && + (m_iPhysicalAddress == 0xFFFF || bUpdate)); } + if (bRequestUpdate && !RequestPhysicalAddress()) + AddLog(CEC_LOG_ERROR, "failed to request the physical address (1)"); + + CLockObject lock(&m_mutex); return m_iPhysicalAddress; } bool CCECBusDevice::RequestPhysicalAddress(void) { bool bReturn(false); + if (!MyLogicalAddressContains(m_iLogicalAddress)) { + m_handler->MarkBusy(); CStdString strLog; strLog.Format("<< requesting physical address of '%s' (%X)", GetLogicalAddressName(), m_iLogicalAddress); AddLog(CEC_LOG_NOTICE, strLog); bReturn = m_handler->TransmitRequestPhysicalAddress(GetMyLogicalAddress(), m_iLogicalAddress); + m_handler->MarkReady(); } return bReturn; } cec_power_status CCECBusDevice::GetPowerStatus(bool bUpdate /* = false */) { - CLockObject lock(&m_mutex); - if (GetStatus() == CEC_DEVICE_STATUS_PRESENT && - (bUpdate || m_powerStatus == CEC_POWER_STATUS_UNKNOWN)) + bool bRequestUpdate(false); + { + CLockObject lock(&m_mutex); + bRequestUpdate = (GetStatus() == CEC_DEVICE_STATUS_PRESENT && + (bUpdate || m_powerStatus == CEC_POWER_STATUS_UNKNOWN || + m_powerStatus == CEC_POWER_STATUS_IN_TRANSITION_STANDBY_TO_ON)); + } + + if (bRequestUpdate) RequestPowerStatus(); + CLockObject lock(&m_mutex); return m_powerStatus; } bool CCECBusDevice::RequestPowerStatus(void) { bool bReturn(false); + if (!MyLogicalAddressContains(m_iLogicalAddress) && !IsUnsupportedFeature(CEC_OPCODE_GIVE_DEVICE_POWER_STATUS)) { + m_handler->MarkBusy(); CStdString strLog; strLog.Format("<< requesting power status of '%s' (%X)", GetLogicalAddressName(), m_iLogicalAddress); AddLog(CEC_LOG_NOTICE, strLog); bReturn = m_handler->TransmitRequestPowerStatus(GetMyLogicalAddress(), m_iLogicalAddress); + m_handler->MarkReady(); } return bReturn; } cec_vendor_id CCECBusDevice::GetVendorId(bool bUpdate /* = false */) { - CLockObject lock(&m_mutex); - if (GetStatus() == CEC_DEVICE_STATUS_PRESENT && - (bUpdate || m_vendor == CEC_VENDOR_UNKNOWN)) + bool bRequestUpdate(false); + { + CLockObject lock(&m_mutex); + bRequestUpdate = (GetStatus() == CEC_DEVICE_STATUS_PRESENT && + (bUpdate || m_vendor == CEC_VENDOR_UNKNOWN)); + } + + if (bRequestUpdate) RequestVendorId(); + CLockObject lock(&m_mutex); return m_vendor; } bool CCECBusDevice::RequestVendorId(void) { bool bReturn(false); + if (!MyLogicalAddressContains(m_iLogicalAddress)) { + m_handler->MarkBusy(); CStdString strLog; strLog.Format("<< requesting vendor ID of '%s' (%X)", GetLogicalAddressName(), m_iLogicalAddress); AddLog(CEC_LOG_NOTICE, strLog); bReturn = m_handler->TransmitRequestVendorId(GetMyLogicalAddress(), m_iLogicalAddress); + m_handler->MarkReady(); + + ReplaceHandler(true); } return bReturn; } @@ -451,6 +513,12 @@ void CCECBusDevice::SetInactiveSource(void) void CCECBusDevice::SetActiveSource(void) { CLockObject lock(&m_mutex); + if (!m_bActiveSource) + { + CStdString strLog; + strLog.Format("making %s (%x) the active source", GetLogicalAddressName(), m_iLogicalAddress); + AddLog(CEC_LOG_DEBUG, strLog); + } for (int iPtr = 0; iPtr < 16; iPtr++) if (iPtr != m_iLogicalAddress) @@ -558,41 +626,63 @@ void CCECBusDevice::SetPowerStatus(const cec_power_status powerStatus) } } -bool CCECBusDevice::SetVendorId(uint64_t iVendorId, bool bInitHandler /* = true */) +bool CCECBusDevice::ReplaceHandler(bool bActivateSource /* = true */) { - bool bVendorChanged(false); + CLockObject lock(&m_mutex); + CLockObject handlerLock(&m_handlerMutex); + if (m_vendor != m_handler->GetVendorId()) { - CLockObject lock(&m_mutex); - bVendorChanged = (m_vendor != (cec_vendor_id)iVendorId); - m_vendor = (cec_vendor_id)iVendorId; + if (CCECCommandHandler::HasSpecificHandler(m_vendor)) + { + CStdString strLog; + if (m_handler->InUse()) + { + strLog.Format("handler for device '%s' (%x) is being used. not replacing the command handler", GetLogicalAddressName(), GetLogicalAddress()); + m_processor->AddLog(CEC_LOG_DEBUG, strLog); + return false; + } - if (bVendorChanged) + strLog.Format("replacing the command handler for device '%s' (%x)", GetLogicalAddressName(), GetLogicalAddress()); + m_processor->AddLog(CEC_LOG_DEBUG, strLog); delete m_handler; - switch (iVendorId) - { - case CEC_VENDOR_SAMSUNG: - if (bVendorChanged) + switch (m_vendor) + { + case CEC_VENDOR_SAMSUNG: m_handler = new CANCommandHandler(this); - break; - case CEC_VENDOR_LG: - if (bVendorChanged) + break; + case CEC_VENDOR_LG: m_handler = new CSLCommandHandler(this); - break; - case CEC_VENDOR_PANASONIC: - if (bVendorChanged) + break; + case CEC_VENDOR_PANASONIC: m_handler = new CVLCommandHandler(this); - break; - default: - if (bVendorChanged) + break; + default: m_handler = new CCECCommandHandler(this); - break; + break; + } + + m_handler->SetVendorId(m_vendor); + m_handler->InitHandler(); + + if (bActivateSource && m_processor->GetLogicalAddresses().IsSet(m_iLogicalAddress) && m_processor->IsInitialised() && IsActiveSource()) + m_handler->ActivateSource(); } } - if (bVendorChanged && bInitHandler && m_handler->GetVendorId() != CEC_VENDOR_UNKNOWN) - m_handler->InitHandler(); + return true; +} + +bool CCECBusDevice::SetVendorId(uint64_t iVendorId) +{ + bool bVendorChanged(false); + + { + CLockObject lock(&m_mutex); + bVendorChanged = (m_vendor != (cec_vendor_id)iVendorId); + m_vendor = (cec_vendor_id)iVendorId; + } CStdString strLog; strLog.Format("%s (%X): vendor = %s (%06x)", GetLogicalAddressName(), m_iLogicalAddress, ToString(m_vendor), m_vendor); @@ -631,7 +721,14 @@ bool CCECBusDevice::TransmitActiveSource(void) } } - return bSendActiveSource ? m_handler->TransmitActiveSource(m_iLogicalAddress, m_iPhysicalAddress) : false; + if (bSendActiveSource) + { + m_handler->TransmitImageViewOn(m_iLogicalAddress, CECDEVICE_TV); + m_handler->TransmitActiveSource(m_iLogicalAddress, m_iPhysicalAddress); + return true; + } + + return false; } bool CCECBusDevice::TransmitCECVersion(cec_logical_address dest) @@ -814,4 +911,11 @@ void CCECBusDevice::SetUnsupportedFeature(cec_opcode opcode) { m_unsupportedFeatures.insert(opcode); } + +bool CCECBusDevice::ActivateSource(void) +{ + CLockObject lock(&m_mutex); + return m_handler->ActivateSource(); +} + //@}