X-Git-Url: https://git.piment-noir.org/?a=blobdiff_plain;f=src%2Futils%2FConstants.ts;h=c4ce0ff8c48e30b8faefd22a118c1718ec74505a;hb=a1c394ae6f706a51274c4a2adb1d5d89c0913596;hp=246aa7882e92a2b99b3dc54e074f833f6f9ecc6d;hpb=268a74bb051fcbbad532fd833f0d8fd2b33b6c64;p=e-mobility-charging-stations-simulator.git diff --git a/src/utils/Constants.ts b/src/utils/Constants.ts index 246aa788..c4ce0ff8 100644 --- a/src/utils/Constants.ts +++ b/src/utils/Constants.ts @@ -1,13 +1,24 @@ -import { MeterValueMeasurand } from '../types'; +import type { AutomaticTransactionGeneratorConfiguration } from '../types'; export class Constants { - static readonly OCPP_DEFAULT_BOOT_NOTIFICATION_INTERVAL = 60000; // Ms - static readonly OCPP_WEBSOCKET_TIMEOUT = 60000; // Ms - static readonly OCPP_TRIGGER_MESSAGE_DELAY = 500; // Ms + static readonly DEFAULT_BOOT_NOTIFICATION_INTERVAL = 60000; // Ms + static readonly DEFAULT_HEARTBEAT_INTERVAL = 60000; // Ms + static readonly DEFAULT_METER_VALUES_INTERVAL = 60000; // Ms static readonly CHARGING_STATION_DEFAULT_RESET_TIME = 60000; // Ms static readonly CHARGING_STATION_ATG_INITIALIZATION_TIME = 1000; // Ms - static readonly CHARGING_STATION_ATG_DEFAULT_STOP_AFTER_HOURS = 0.25; // Hours + + static readonly DEFAULT_ATG_CONFIGURATION: AutomaticTransactionGeneratorConfiguration = + Object.freeze({ + enable: false, + minDuration: 60, + maxDuration: 120, + minDelayBetweenTwoTransactions: 15, + maxDelayBetweenTwoTransactions: 30, + probabilityOfStart: 1, + stopAfterHours: 0.25, + stopOnConnectionFailure: true, + }); // See https://semver.org/#is-there-a-suggested-regular-expression-regex-to-check-a-semver-string static readonly SEMVER_PATTERN = @@ -23,19 +34,9 @@ export class Constants { static readonly DEFAULT_LOG_STATISTICS_INTERVAL = 60; // Seconds - static readonly DEFAULT_HEARTBEAT_INTERVAL = 60000; // Ms - static readonly DEFAULT_METER_VALUES_INTERVAL = 60000; // Ms - - static readonly SUPPORTED_MEASURANDS = Object.freeze([ - MeterValueMeasurand.STATE_OF_CHARGE, - MeterValueMeasurand.VOLTAGE, - MeterValueMeasurand.POWER_ACTIVE_IMPORT, - MeterValueMeasurand.CURRENT_IMPORT, - MeterValueMeasurand.ENERGY_ACTIVE_IMPORT_REGISTER, - ]); - static readonly DEFAULT_FLUCTUATION_PERCENT = 5; + static readonly DEFAULT_PERFORMANCE_DIRECTORY = 'performance'; static readonly DEFAULT_PERFORMANCE_RECORDS_FILENAME = 'performanceRecords.json'; static readonly DEFAULT_PERFORMANCE_RECORDS_DB_NAME = 'e-mobility-charging-stations-simulator'; static readonly PERFORMANCE_RECORDS_TABLE = 'performance_records'; @@ -47,6 +48,15 @@ export class Constants { static readonly MAX_RANDOM_INTEGER = 281474976710654; + static readonly STOP_SIMULATOR_TIMEOUT = 120000; // Ms + + static readonly EMPTY_FREEZED_OBJECT = Object.freeze({}); + static readonly EMPTY_FUNCTION = Object.freeze(() => { + /* This is intentional */ + }); + + static readonly DEFAULT_RESERVATION_EXPIRATION_OBSERVATION_INTERVAL = 5000; // Ms + private constructor() { // This is intentional }