X-Git-Url: https://git.piment-noir.org/?a=blobdiff_plain;f=src%2Futils%2FConstants.ts;h=c83340e4950d36177eb29c358b4b19130f604688;hb=ae8ee665e864460d582b7f6d501b25225a1d7a4c;hp=8b1df1ca31983bbd400ec0a0c039be124de111d4;hpb=101196c654ddcd686e4992f58864f591ceea6c00;p=e-mobility-charging-stations-simulator.git diff --git a/src/utils/Constants.ts b/src/utils/Constants.ts index 8b1df1ca..c83340e4 100644 --- a/src/utils/Constants.ts +++ b/src/utils/Constants.ts @@ -1,9 +1,9 @@ -import { AvailabilityStatus, ChargingProfileStatus, ClearChargingProfileStatus, ConfigurationStatus, DefaultStatus, UnlockStatus } from '../types/ocpp/1.6/Responses'; +import { AvailabilityStatus, ChargingProfileStatus, ClearChargingProfileStatus, ConfigurationStatus, DefaultStatus, UnlockStatus } from '../types/ocpp/Responses'; -export default class Constants { - static readonly ENTITY_CHARGING_STATION = 'ChargingStation'; - static readonly ENTITY_AUTOMATIC_TRANSACTION_GENERATOR = 'AutomaticTransactionGenerator'; +import { MeterValueMeasurand } from '../types/ocpp/MeterValues'; +export default class Constants { + static readonly OCPP_RESPONSE_EMPTY = Object.freeze({}); static readonly OCPP_RESPONSE_ACCEPTED = Object.freeze({ status: DefaultStatus.ACCEPTED }); static readonly OCPP_RESPONSE_REJECTED = Object.freeze({ status: DefaultStatus.REJECTED }); static readonly OCPP_CONFIGURATION_RESPONSE_ACCEPTED = Object.freeze({ status: ConfigurationStatus.ACCEPTED }); @@ -23,7 +23,7 @@ export default class Constants { static readonly OCPP_AVAILABILITY_RESPONSE_SCHEDULED = Object.freeze({ status: AvailabilityStatus.SCHEDULED }); static readonly OCPP_DEFAULT_BOOT_NOTIFICATION_INTERVAL = 60000; // Ms - static readonly OCPP_ERROR_TIMEOUT = 60000; // 60 sec + static readonly OCPP_ERROR_TIMEOUT = 60000; // Ms static readonly CHARGING_STATION_DEFAULT_RESET_TIME = 60000; // Ms static readonly CHARGING_STATION_ATG_WAIT_TIME = 2000; // Ms @@ -33,4 +33,21 @@ export default class Constants { static readonly WORKER_START_DELAY = 500; static readonly WORKER_POOL_MAX_INACTIVE_TIME = 60000; + static readonly DEFAULT_WORKER_POOL_MIN_SIZE = 4; + static readonly DEFAULT_WORKER_POOL_MAX_SIZE = 16; + static readonly DEFAULT_CHARGING_STATIONS_PER_WORKER = 1; + + static readonly DEFAULT_CONNECTION_TIMEOUT = 30; + + static readonly DEFAULT_HEARTBEAT_INTERVAL = 60000; // Ms + + static readonly SUPPORTED_MEASURANDS = Object.freeze([MeterValueMeasurand.STATE_OF_CHARGE, MeterValueMeasurand.VOLTAGE, + MeterValueMeasurand.POWER_ACTIVE_IMPORT, MeterValueMeasurand.CURRENT_IMPORT, MeterValueMeasurand.ENERGY_ACTIVE_IMPORT_REGISTER]); + + static readonly DEFAULT_FLUCTUATION_PERCENT = 5; + + static readonly PERFORMANCE_RECORDS_FILETYPE = 'Performance records'; + static readonly DEFAULT_PERFORMANCE_RECORDS_FILENAME = 'performanceRecords.json'; + static readonly DEFAULT_PERFORMANCE_RECORDS_DB_NAME = 'charging-stations-simulator'; + static readonly PERFORMANCE_RECORDS_TABLE = 'performance_records'; }