**src/assets/station-templates/\<name\>.json**:
-| Key | Value(s) | Default Value | Value type | Description |
-| ---------------------------------------------------- | ------------- | ----------------------------------------------------------------------------------------------------------------------------------- | ------------------------------------------------------------------------------------------------------------------------------------------------------------------------ | ----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------- |
-| supervisionUrls | | [] | string \| string[] | string or array of connection URIs to OCPP-J servers |
-| supervisionUser | | undefined | string | basic HTTP authentication user to OCPP-J server |
-| supervisionPassword | | undefined | string | basic HTTP authentication password to OCPP-J server |
-| supervisionUrlOcppConfiguration | true/false | false | boolean | allow supervision URL configuration via a vendor OCPP parameter key |
-| supervisionUrlOcppKey | | 'ConnectionUrl' | string | the vendor string that will be used as a vendor OCPP parameter key to set the supervision URL |
-| ocppVersion | 1.6/2.0/2.0.1 | 1.6 | string | OCPP version |
-| ocppProtocol | json | json | string | OCPP protocol |
-| ocppStrictCompliance | true/false | false | boolean | strict adherence to the OCPP version and protocol specifications |
-| ocppPersistentConfiguration | true/false | true | boolean | enable persistent OCPP parameters storage by charging stations 'hashId'. The persistency is ensured by the charging stations configuration files in [dist/assets/configurations](dist/assets/configurations) |
-| stationInfoPersistentConfiguration | true/false | true | boolean | enable persistent station information and specifications storage by charging stations 'hashId'. The persistency is ensured by the charging stations configuration files in [dist/assets/configurations](dist/assets/configurations) |
-| automaticTransactionGeneratorPersistentConfiguration | true/false | true | boolean | enable persistent automatic transaction generator storage by charging stations 'hashId'. The persistency is ensured by the charging stations configuration files in [dist/assets/configurations](dist/assets/configurations) |
-| wsOptions | | {} | ClientOptions & ClientRequestArgs | [ws](https://github.com/websockets/ws) and node.js [http](https://nodejs.org/api/http.html) clients options intersection |
-| idTagsFile | | undefined | string | RFID tags list file relative to src/assets path |
-| baseName | | undefined | string | base name to build charging stations id |
-| nameSuffix | | undefined | string | name suffix to build charging stations id |
-| fixedName | true/false | false | boolean | use the baseName as the charging stations unique name |
-| chargePointModel | | undefined | string | charging stations model |
-| chargePointVendor | | undefined | string | charging stations vendor |
-| chargePointSerialNumberPrefix | | undefined | string | charge point serial number prefix |
-| chargeBoxSerialNumberPrefix | | undefined | string | charge box serial number prefix (deprecated in OCPP 1.6) |
-| firmwareVersionPattern | | Semantic versionning regular expression: https://semver.org/#is-there-a-suggested-regular-expression-regex-to-check-a-semver-string | string | charging stations firmware version pattern |
-| firmwareVersion | | undefined | string | charging stations firmware version |
-| power | | | float \| float[] | charging stations maximum power value(s) |
-| powerSharedByConnectors | true/false | false | boolean | charging stations power shared by its connectors |
-| powerUnit | W/kW | W | string | charging stations power unit |
-| currentOutType | AC/DC | AC | string | charging stations current out type |
-| voltageOut | | AC:230/DC:400 | integer | charging stations voltage out |
-| numberOfPhases | 0/1/3 | AC:3/DC:0 | integer | charging stations number of phase(s) |
-| numberOfConnectors | | | integer \| integer[] | charging stations number of connector(s) |
-| useConnectorId0 | true/false | true | boolean | use connector id 0 definition from the charging station configuration template |
-| randomConnectors | true/false | false | boolean | randomize runtime connector id affectation from the connector id definition in charging station configuration template |
-| resetTime | | 60 | integer | seconds to wait before the charging stations come back at reset |
-| autoRegister | true/false | false | boolean | set charging stations as registered at boot notification for testing purpose |
-| autoReconnectMaxRetries | | -1 (unlimited) | integer | connection retries to the OCPP-J server |
-| reconnectExponentialDelay | true/false | false | boolean | connection delay retry to the OCPP-J server |
-| registrationMaxRetries | | -1 (unlimited) | integer | charging stations boot notification retries |
-| amperageLimitationOcppKey | | undefined | string | charging stations OCPP parameter key used to set the amperage limit, per phase for each connector on AC and global for DC |
-| amperageLimitationUnit | A/cA/dA/mA | A | string | charging stations amperage limit unit |
-| enableStatistics | true/false | false | boolean | enable charging stations statistics |
-| mustAuthorizeAtRemoteStart | true/false | true | boolean | always send authorize at remote start transaction when AuthorizeRemoteTxRequests is enabled |
-| payloadSchemaValidation | true/false | true | boolean | validate OCPP commands PDU against [OCA](https://www.openchargealliance.org/) JSON schemas |
-| beginEndMeterValues | true/false | false | boolean | enable Transaction.{Begin,End} MeterValues |
-| outOfOrderEndMeterValues | true/false | false | boolean | send Transaction.End MeterValues out of order. Need to relax OCPP specifications strict compliance ('ocppStrictCompliance' parameter) |
-| meteringPerTransaction | true/false | true | boolean | enable metering history on a per transaction basis |
-| transactionDataMeterValues | true/false | false | boolean | enable transaction data MeterValues at stop transaction |
-| mainVoltageMeterValues | true/false | true | boolean | include charging stations main voltage MeterValues on three phased charging stations |
-| phaseLineToLineVoltageMeterValues | true/false | false | boolean | include charging stations line to line voltage MeterValues on three phased charging stations |
-| customValueLimitationMeterValues | true/false | true | boolean | enable limitation on custom fluctuated value in MeterValues |
-| firmwareUpgrade | | {<br />"versionUpgrade": {<br />"step": 1<br />},<br />"reset": true<br />} | {<br />versionUpgrade: {<br />patternGroup: number;<br />step: number;<br />};<br />reset: boolean;<br />failureStatus: 'DownloadFailed' \| 'InstallationFailed';<br />} | Configuration section for simulating firmware upgrade support. |
-| commandsSupport | | {<br />"incomingCommands": {},<br />"outgoingCommands": {}<br />} | {<br /> incomingCommands: Record<IncomingRequestCommand, boolean>;<br />outgoingCommands?: Record<RequestCommand, boolean>;<br />} | Configuration section for OCPP commands support. Empty section or subsections means all implemented OCPP commands are supported |
-| messageTriggerSupport | | {} | Record<MessageTrigger, boolean> | Configuration section for OCPP commands trigger support. Empty section means all implemented OCPP trigger commands are supported |
-| Configuration | | | ChargingStationOcppConfiguration | charging stations OCPP parameters configuration section |
-| AutomaticTransactionGenerator | | | AutomaticTransactionGeneratorConfiguration | charging stations ATG configuration section |
-| Connectors | | | Record<string, ConnectorStatus> | charging stations connectors configuration section |
-| Evses | | | Record<string, EvseTemplate> | charging stations EVSEs configuration section |
+| Key | Value(s) | Default Value | Value type | Description |
+| ---------------------------------------------------- | ------------- | ----------------------------------------------------------------------------------------------------------------------------------- | ------------------------------------------------------------------------------------------------------------------------------------------------------------------------ | ------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------ |
+| supervisionUrls | | [] | string \| string[] | string or array of connection URIs to OCPP-J servers |
+| supervisionUser | | undefined | string | basic HTTP authentication user to OCPP-J server |
+| supervisionPassword | | undefined | string | basic HTTP authentication password to OCPP-J server |
+| supervisionUrlOcppConfiguration | true/false | false | boolean | allow supervision URL configuration via a vendor OCPP parameter key |
+| supervisionUrlOcppKey | | 'ConnectionUrl' | string | the vendor string that will be used as a vendor OCPP parameter key to set the supervision URL |
+| ocppVersion | 1.6/2.0/2.0.1 | 1.6 | string | OCPP version |
+| ocppProtocol | json | json | string | OCPP protocol |
+| ocppStrictCompliance | true/false | false | boolean | strict adherence to the OCPP version and protocol specifications |
+| ocppPersistentConfiguration | true/false | true | boolean | enable persistent OCPP parameters storage by charging stations 'hashId'. The persistency is ensured by the charging stations configuration files in [dist/assets/configurations](dist/assets/configurations) |
+| stationInfoPersistentConfiguration | true/false | true | boolean | enable persistent station information and specifications storage by charging stations 'hashId'. The persistency is ensured by the charging stations configuration files in [dist/assets/configurations](dist/assets/configurations) |
+| automaticTransactionGeneratorPersistentConfiguration | true/false | true | boolean | enable persistent automatic transaction generator configuration storage by charging stations 'hashId'. The persistency is ensured by the charging stations configuration files in [dist/assets/configurations](dist/assets/configurations) |
+| wsOptions | | {} | ClientOptions & ClientRequestArgs | [ws](https://github.com/websockets/ws) and node.js [http](https://nodejs.org/api/http.html) clients options intersection |
+| idTagsFile | | undefined | string | RFID tags list file relative to src/assets path |
+| baseName | | undefined | string | base name to build charging stations id |
+| nameSuffix | | undefined | string | name suffix to build charging stations id |
+| fixedName | true/false | false | boolean | use the baseName as the charging stations unique name |
+| chargePointModel | | undefined | string | charging stations model |
+| chargePointVendor | | undefined | string | charging stations vendor |
+| chargePointSerialNumberPrefix | | undefined | string | charge point serial number prefix |
+| chargeBoxSerialNumberPrefix | | undefined | string | charge box serial number prefix (deprecated in OCPP 1.6) |
+| firmwareVersionPattern | | Semantic versionning regular expression: https://semver.org/#is-there-a-suggested-regular-expression-regex-to-check-a-semver-string | string | charging stations firmware version pattern |
+| firmwareVersion | | undefined | string | charging stations firmware version |
+| power | | | float \| float[] | charging stations maximum power value(s) |
+| powerSharedByConnectors | true/false | false | boolean | charging stations power shared by its connectors |
+| powerUnit | W/kW | W | string | charging stations power unit |
+| currentOutType | AC/DC | AC | string | charging stations current out type |
+| voltageOut | | AC:230/DC:400 | integer | charging stations voltage out |
+| numberOfPhases | 0/1/3 | AC:3/DC:0 | integer | charging stations number of phase(s) |
+| numberOfConnectors | | | integer \| integer[] | charging stations number of connector(s) |
+| useConnectorId0 | true/false | true | boolean | use connector id 0 definition from the charging station configuration template |
+| randomConnectors | true/false | false | boolean | randomize runtime connector id affectation from the connector id definition in charging station configuration template |
+| resetTime | | 60 | integer | seconds to wait before the charging stations come back at reset |
+| autoRegister | true/false | false | boolean | set charging stations as registered at boot notification for testing purpose |
+| autoReconnectMaxRetries | | -1 (unlimited) | integer | connection retries to the OCPP-J server |
+| reconnectExponentialDelay | true/false | false | boolean | connection delay retry to the OCPP-J server |
+| registrationMaxRetries | | -1 (unlimited) | integer | charging stations boot notification retries |
+| amperageLimitationOcppKey | | undefined | string | charging stations OCPP parameter key used to set the amperage limit, per phase for each connector on AC and global for DC |
+| amperageLimitationUnit | A/cA/dA/mA | A | string | charging stations amperage limit unit |
+| enableStatistics | true/false | false | boolean | enable charging stations statistics |
+| mustAuthorizeAtRemoteStart | true/false | true | boolean | always send authorize at remote start transaction when AuthorizeRemoteTxRequests is enabled |
+| payloadSchemaValidation | true/false | true | boolean | validate OCPP commands PDU against [OCA](https://www.openchargealliance.org/) JSON schemas |
+| beginEndMeterValues | true/false | false | boolean | enable Transaction.{Begin,End} MeterValues |
+| outOfOrderEndMeterValues | true/false | false | boolean | send Transaction.End MeterValues out of order. Need to relax OCPP specifications strict compliance ('ocppStrictCompliance' parameter) |
+| meteringPerTransaction | true/false | true | boolean | enable metering history on a per transaction basis |
+| transactionDataMeterValues | true/false | false | boolean | enable transaction data MeterValues at stop transaction |
+| mainVoltageMeterValues | true/false | true | boolean | include charging stations main voltage MeterValues on three phased charging stations |
+| phaseLineToLineVoltageMeterValues | true/false | false | boolean | include charging stations line to line voltage MeterValues on three phased charging stations |
+| customValueLimitationMeterValues | true/false | true | boolean | enable limitation on custom fluctuated value in MeterValues |
+| firmwareUpgrade | | {<br />"versionUpgrade": {<br />"step": 1<br />},<br />"reset": true<br />} | {<br />versionUpgrade: {<br />patternGroup: number;<br />step: number;<br />};<br />reset: boolean;<br />failureStatus: 'DownloadFailed' \| 'InstallationFailed';<br />} | Configuration section for simulating firmware upgrade support. |
+| commandsSupport | | {<br />"incomingCommands": {},<br />"outgoingCommands": {}<br />} | {<br /> incomingCommands: Record<IncomingRequestCommand, boolean>;<br />outgoingCommands?: Record<RequestCommand, boolean>;<br />} | Configuration section for OCPP commands support. Empty section or subsections means all implemented OCPP commands are supported |
+| messageTriggerSupport | | {} | Record<MessageTrigger, boolean> | Configuration section for OCPP commands trigger support. Empty section means all implemented OCPP trigger commands are supported |
+| Configuration | | | ChargingStationOcppConfiguration | charging stations OCPP parameters configuration section |
+| AutomaticTransactionGenerator | | | AutomaticTransactionGeneratorConfiguration | charging stations ATG configuration section |
+| Connectors | | | Record<string, ConnectorStatus> | charging stations connectors configuration section |
+| Evses | | | Record<string, EvseTemplate> | charging stations EVSEs configuration section |
#### Configuration section syntax example