From: Jérôme Benoit Date: Thu, 23 Apr 2026 23:29:49 +0000 (+0200) Subject: fix: align Keba OCPP2 templates with OCPP 2.0.1 SampledDataCtrlr specs X-Git-Url: https://git.piment-noir.org/?a=commitdiff_plain;h=bb476f6d88b227e48fabbabfae43f3d4a690e6b3;p=e-mobility-charging-stations-simulator.git fix: align Keba OCPP2 templates with OCPP 2.0.1 SampledDataCtrlr specs Add TxStartedMeasurands and TxEndedMeasurands variables as required by OCPP 2.0.1 (E02.FR.09/E02.FR.10). --- diff --git a/src/assets/station-templates/keba-ocpp2-signed.station-template.json b/src/assets/station-templates/keba-ocpp2-signed.station-template.json index 51fb5319..c19d9bab 100644 --- a/src/assets/station-templates/keba-ocpp2-signed.station-template.json +++ b/src/assets/station-templates/keba-ocpp2-signed.station-template.json @@ -76,6 +76,11 @@ "readonly": false, "value": "Energy.Active.Import.Register,Power.Active.Import,Current.Import,Voltage" }, + { + "key": "SampledDataCtrlr.TxEndedMeasurands", + "readonly": false, + "value": "Energy.Active.Import.Register" + }, { "key": "TxCtrlr.EVConnectionTimeOut", "readonly": false, @@ -91,6 +96,11 @@ "readonly": false, "value": "true" }, + { + "key": "SampledDataCtrlr.TxStartedMeasurands", + "readonly": false, + "value": "Energy.Active.Import.Register" + }, { "key": "SampledDataCtrlr.SignUpdatedReadings", "readonly": false, diff --git a/src/assets/station-templates/keba-ocpp2.station-template.json b/src/assets/station-templates/keba-ocpp2.station-template.json index b7029425..7ee304d3 100644 --- a/src/assets/station-templates/keba-ocpp2.station-template.json +++ b/src/assets/station-templates/keba-ocpp2.station-template.json @@ -76,6 +76,16 @@ "readonly": false, "value": "Energy.Active.Import.Register,Power.Active.Import,Current.Import,Voltage" }, + { + "key": "SampledDataCtrlr.TxStartedMeasurands", + "readonly": false, + "value": "Energy.Active.Import.Register" + }, + { + "key": "SampledDataCtrlr.TxEndedMeasurands", + "readonly": false, + "value": "Energy.Active.Import.Register" + }, { "key": "TxCtrlr.EVConnectionTimeOut", "readonly": false,