From: Jérôme Benoit Date: Sun, 4 Feb 2024 14:12:46 +0000 (+0100) Subject: docs: refine configuration sections type definition in README.md X-Git-Tag: v1.2.35~15 X-Git-Url: https://git.piment-noir.org/?a=commitdiff_plain;h=dda3305e19f76690feaacc3298ce3996f0ba2c5b;p=e-mobility-charging-stations-simulator.git docs: refine configuration sections type definition in README.md Signed-off-by: Jérôme Benoit --- diff --git a/README.md b/README.md index a347623d..90690d07 100644 --- a/README.md +++ b/README.md @@ -101,15 +101,15 @@ But the modifications to test have to be done to the files in the build target d **src/assets/config.json**: -| Key | Value(s) | Default Value | Value type | Description | -| -------------------------- | -------------------------------------------- | ----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------- | ------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------ | ---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------- | -| supervisionUrls | | [] | string \| string[] | string or strings array containing global connection URIs to OCPP-J servers | -| supervisionUrlDistribution | round-robin/random/charging-station-affinity | charging-station-affinity | string | supervision urls distribution policy to simulated charging stations | -| log | | {
"enabled": true,
"file": "logs/combined.log",
"errorFile": "logs/error.log",
"statisticsInterval": 60,
"level": "info",
"console": false,
"format": "simple",
"rotate": true
} | {
enabled: boolean;
file: string;
errorFile: string;
statisticsInterval: number;
level: string;
console: boolean;
format: string;
rotate: boolean;
maxFiles: string \| number;
maxSize: string \| number;
} | Log configuration section:
- _enabled_: enable logging
- _file_: log file relative path
- _errorFile_: error log file relative path
- _statisticsInterval_: seconds between charging stations statistics output in the logs
- _level_: emerg/alert/crit/error/warning/notice/info/debug [winston](https://github.com/winstonjs/winston) logging level
- _console_: output logs on the console
- _format_: [winston](https://github.com/winstonjs/winston) log format
- _rotate_: enable daily log files rotation
- _maxFiles_: maximum number of log files: https://github.com/winstonjs/winston-daily-rotate-file#options
- _maxSize_: maximum size of log files in bytes, or units of kb, mb, and gb: https://github.com/winstonjs/winston-daily-rotate-file#options | -| worker | | {
"processType": "workerSet",
"startDelay": 500,
"elementStartDelay": 0,
"elementsPerWorker": 'auto',
"poolMinSize": 4,
"poolMaxSize": 16
} | {
processType: WorkerProcessType;
startDelay: number;
elementStartDelay: number;
elementsPerWorker: number \| 'auto' \| 'all';
poolMinSize: number;
poolMaxSize: number;
resourceLimits: ResourceLimits;
} | Worker configuration section:
- _processType_: worker threads process type (`workerSet`/`fixedPool`/`dynamicPool`)
- _startDelay_: milliseconds to wait at worker threads startup (only for `workerSet` worker threads process type)
- _elementStartDelay_: milliseconds to wait at charging station startup
- _elementsPerWorker_: number of charging stations per worker threads for the `workerSet` process type (`auto` means (number of stations) / (number of CPUs) \* 1.5 if (number of stations) > (number of CPUs), otherwise 1; `all` means a unique worker will run all charging stations)
- _poolMinSize_: worker threads pool minimum number of threads
- _poolMaxSize_: worker threads pool maximum number of threads
- _resourceLimits_: worker threads [resource limits](https://nodejs.org/api/worker_threads.html#new-workerfilename-options) object option | -| uiServer | | {
"enabled": false,
"type": "ws",
"version": "1.1",
"options": {
"host": "localhost",
"port": 8080
}
} | {
enabled: boolean;
type: ApplicationProtocol;
version: ApplicationProtocolVersion;
options: ServerOptions;
authentication: {
enabled: boolean;
type: AuthenticationType;
username: string;
password: string;
}
} | UI server configuration section:
- _enabled_: enable UI server
- _type_: 'http' or 'ws'
- _version_: HTTP version '1.1' or '2.0'
- _options_: node.js net module [listen options](https://nodejs.org/api/net.html#serverlistenoptions-callback) | -| performanceStorage | | {
"enabled": false,
"type": "jsonfile",
"uri": "file:///performance/performanceRecords.json"
} | {
enabled: boolean;
type: string;
uri: string;
} | Performance storage configuration section:
- _enabled_: enable performance storage
- _type_: 'jsonfile' or 'mongodb'
- _uri_: storage URI | -| stationTemplateUrls | | {}[] | {
file: string;
numberOfStations: number;
}[] | array of charging station configuration templates URIs configuration section (charging station configuration template file name and number of stations) | +| Key | Value(s) | Default Value | Value type | Description | +| -------------------------- | -------------------------------------------- | ----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------- | ------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------- | ---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------- | +| supervisionUrls | | [] | string \| string[] | string or strings array containing global connection URIs to OCPP-J servers | +| supervisionUrlDistribution | round-robin/random/charging-station-affinity | charging-station-affinity | string | supervision urls distribution policy to simulated charging stations | +| log | | {
"enabled": true,
"file": "logs/combined.log",
"errorFile": "logs/error.log",
"statisticsInterval": 60,
"level": "info",
"console": false,
"format": "simple",
"rotate": true
} | {
enabled?: boolean;
file?: string;
errorFile?: string;
statisticsInterval?: number;
level?: string;
console?: boolean;
format?: string;
rotate?: boolean;
maxFiles?: string \| number;
maxSize?: string \| number;
} | Log configuration section:
- _enabled_: enable logging
- _file_: log file relative path
- _errorFile_: error log file relative path
- _statisticsInterval_: seconds between charging stations statistics output in the logs
- _level_: emerg/alert/crit/error/warning/notice/info/debug [winston](https://github.com/winstonjs/winston) logging level
- _console_: output logs on the console
- _format_: [winston](https://github.com/winstonjs/winston) log format
- _rotate_: enable daily log files rotation
- _maxFiles_: maximum number of log files: https://github.com/winstonjs/winston-daily-rotate-file#options
- _maxSize_: maximum size of log files in bytes, or units of kb, mb, and gb: https://github.com/winstonjs/winston-daily-rotate-file#options | +| worker | | {
"processType": "workerSet",
"startDelay": 500,
"elementStartDelay": 0,
"elementsPerWorker": 'auto',
"poolMinSize": 4,
"poolMaxSize": 16
} | {
processType?: WorkerProcessType;
startDelay?: number;
elementStartDelay?: number;
elementsPerWorker?: number \| 'auto' \| 'all';
poolMinSize?: number;
poolMaxSize: number;
resourceLimits?: ResourceLimits;
} | Worker configuration section:
- _processType_: worker threads process type (`workerSet`/`fixedPool`/`dynamicPool`)
- _startDelay_: milliseconds to wait at worker threads startup (only for `workerSet` worker threads process type)
- _elementStartDelay_: milliseconds to wait at charging station startup
- _elementsPerWorker_: number of charging stations per worker threads for the `workerSet` process type (`auto` means (number of stations) / (number of CPUs) \* 1.5 if (number of stations) > (number of CPUs), otherwise 1; `all` means a unique worker will run all charging stations)
- _poolMinSize_: worker threads pool minimum number of threads
- _poolMaxSize_: worker threads pool maximum number of threads
- _resourceLimits_: worker threads [resource limits](https://nodejs.org/api/worker_threads.html#new-workerfilename-options) object option | +| uiServer | | {
"enabled": false,
"type": "ws",
"version": "1.1",
"options": {
"host": "localhost",
"port": 8080
}
} | {
enabled?: boolean;
type?: ApplicationProtocol;
version?: ApplicationProtocolVersion;
options?: ServerOptions;
authentication?: {
enabled: boolean;
type: AuthenticationType;
username?: string;
password?: string;
}
} | UI server configuration section:
- _enabled_: enable UI server
- _type_: 'http' or 'ws'
- _version_: HTTP version '1.1' or '2.0'
- _options_: node.js net module [listen options](https://nodejs.org/api/net.html#serverlistenoptions-callback)
- _authentication_: authentication type configuration section | +| performanceStorage | | {
"enabled": false,
"type": "jsonfile",
"uri": "file:///performance/performanceRecords.json"
} | {
enabled?: boolean;
type?: string;
uri?: string;
} | Performance storage configuration section:
- _enabled_: enable performance storage
- _type_: 'jsonfile' or 'mongodb'
- _uri_: storage URI | +| stationTemplateUrls | | {}[] | {
file: string;
numberOfStations: number;
}[] | array of charging station configuration templates URIs configuration section (charging station configuration template file name and number of stations) | #### Worker process model @@ -126,63 +126,63 @@ But the modifications to test have to be done to the files in the build target d **src/assets/station-templates/\.json**: -| Key | Value(s) | Default Value | Value type | Description | -| ---------------------------------------------------- | ------------- | ---------------------------------------------------------------------------------------------------------------------------------- | ------------------------------------------------------------------------------------------------------------------------------------------------------------------------ | ------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------ | -| supervisionUrls | | [] | string \| string[] | string or strings array containing connection URIs to OCPP-J servers | -| supervisionUser | | undefined | string | basic HTTP authentication user to OCPP-J server | -| supervisionPassword | | undefined | string | basic HTTP authentication password to OCPP-J server | -| supervisionUrlOcppConfiguration | true/false | false | boolean | allow supervision URL configuration via a vendor OCPP parameter key | -| supervisionUrlOcppKey | | 'ConnectionUrl' | string | the vendor string that will be used as a vendor OCPP parameter key to set the supervision URL | -| ocppVersion | 1.6/2.0/2.0.1 | 1.6 | string | OCPP version | -| ocppProtocol | json | json | string | OCPP protocol | -| ocppStrictCompliance | true/false | true | boolean | strict adherence to the OCPP version and protocol specifications with OCPP commands PDU validation against [OCA](https://www.openchargealliance.org/) JSON schemas | -| ocppPersistentConfiguration | true/false | true | boolean | enable persistent OCPP parameters storage by charging stations 'hashId'. The persistency is ensured by the charging stations configuration files in [dist/assets/configurations](dist/assets/configurations) | -| stationInfoPersistentConfiguration | true/false | true | boolean | enable persistent station information and specifications storage by charging stations 'hashId'. The persistency is ensured by the charging stations configuration files in [dist/assets/configurations](dist/assets/configurations) | -| automaticTransactionGeneratorPersistentConfiguration | true/false | true | boolean | enable persistent automatic transaction generator configuration storage by charging stations 'hashId'. The persistency is ensured by the charging stations configuration files in [dist/assets/configurations](dist/assets/configurations) | -| wsOptions | | {} | ClientOptions & ClientRequestArgs | [ws](https://github.com/websockets/ws) and node.js [http](https://nodejs.org/api/http.html) clients options intersection | -| idTagsFile | | undefined | string | RFID tags list file relative to [src/assets](src/assets) path | -| baseName | | undefined | string | base name to build charging stations id | -| nameSuffix | | undefined | string | name suffix to build charging stations id | -| fixedName | true/false | false | boolean | use the 'baseName' as the charging stations unique name | -| chargePointModel | | undefined | string | charging stations model | -| chargePointVendor | | undefined | string | charging stations vendor | -| chargePointSerialNumberPrefix | | undefined | string | charge point serial number prefix | -| chargeBoxSerialNumberPrefix | | undefined | string | charge box serial number prefix (deprecated since OCPP 1.6) | -| firmwareVersionPattern | | Semantic versioning regular expression: https://semver.org/#is-there-a-suggested-regular-expression-regex-to-check-a-semver-string | string | charging stations firmware version pattern | -| firmwareVersion | | undefined | string | charging stations firmware version | -| power | | | float \| float[] | charging stations maximum power value(s) | -| powerSharedByConnectors | true/false | false | boolean | charging stations power shared by its connectors | -| powerUnit | W/kW | W | string | charging stations power unit | -| currentOutType | AC/DC | AC | string | charging stations current out type | -| voltageOut | | AC:230/DC:400 | integer | charging stations voltage out | -| numberOfPhases | 0/1/3 | AC:3/DC:0 | integer | charging stations number of phase(s) | -| numberOfConnectors | | | integer \| integer[] | charging stations number of connector(s) | -| useConnectorId0 | true/false | true | boolean | use connector id 0 definition from the charging station configuration template | -| randomConnectors | true/false | false | boolean | randomize runtime connector id affectation from the connector id definition in charging station configuration template | -| resetTime | | 60 | integer | seconds to wait before the charging stations come back at reset | -| autoRegister | true/false | false | boolean | set charging stations as registered at boot notification for testing purpose | -| autoReconnectMaxRetries | | -1 (unlimited) | integer | connection retries to the OCPP-J server | -| reconnectExponentialDelay | true/false | false | boolean | connection delay retry to the OCPP-J server | -| registrationMaxRetries | | -1 (unlimited) | integer | charging stations boot notification retries | -| amperageLimitationOcppKey | | undefined | string | charging stations OCPP parameter key used to set the amperage limit, per phase for each connector on AC and global for DC | -| amperageLimitationUnit | A/cA/dA/mA | A | string | charging stations amperage limit unit | -| enableStatistics | true/false | false | boolean | enable charging stations statistics | -| remoteAuthorization | true/false | true | boolean | enable RFID tags remote authorization | -| beginEndMeterValues | true/false | false | boolean | enable Transaction.{Begin,End} MeterValues | -| outOfOrderEndMeterValues | true/false | false | boolean | send Transaction.End MeterValues out of order. Need to relax OCPP specifications strict compliance ('ocppStrictCompliance' parameter) | -| meteringPerTransaction | true/false | true | boolean | enable metering history on a per transaction basis | -| transactionDataMeterValues | true/false | false | boolean | enable transaction data MeterValues at stop transaction | -| stopTransactionsOnStopped | true/false | true | boolean | enable stop transactions on charging station stop | -| mainVoltageMeterValues | true/false | true | boolean | include charging stations main voltage MeterValues on three phased charging stations | -| phaseLineToLineVoltageMeterValues | true/false | false | boolean | include charging stations line to line voltage MeterValues on three phased charging stations | -| customValueLimitationMeterValues | true/false | true | boolean | enable limitation on custom fluctuated value in MeterValues | -| firmwareUpgrade | | {
"versionUpgrade": {
"step": 1
},
"reset": true
} | {
versionUpgrade: {
patternGroup: number;
step: number;
};
reset: boolean;
failureStatus: 'DownloadFailed' \| 'InstallationFailed';
} | Configuration section for simulating firmware upgrade support. | -| commandsSupport | | {
"incomingCommands": {},
"outgoingCommands": {}
} | {
incomingCommands: Record;
outgoingCommands?: Record;
} | Configuration section for OCPP commands support. Empty section or subsections means all implemented OCPP commands are supported | -| messageTriggerSupport | | {} | Record | Configuration section for OCPP commands trigger support. Empty section means all implemented OCPP trigger commands are supported | -| Configuration | | | ChargingStationOcppConfiguration | charging stations OCPP parameters configuration section | -| AutomaticTransactionGenerator | | | AutomaticTransactionGeneratorConfiguration | charging stations ATG configuration section | -| Connectors | | | Record | charging stations connectors configuration section | -| Evses | | | Record | charging stations EVSEs configuration section | +| Key | Value(s) | Default Value | Value type | Description | +| ---------------------------------------------------- | ------------- | ---------------------------------------------------------------------------------------------------------------------------------- | ----------------------------------------------------------------------------------------------------------------------------------------------------------------------------- | ------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------ | +| supervisionUrls | | [] | string \| string[] | string or strings array containing connection URIs to OCPP-J servers | +| supervisionUser | | undefined | string | basic HTTP authentication user to OCPP-J server | +| supervisionPassword | | undefined | string | basic HTTP authentication password to OCPP-J server | +| supervisionUrlOcppConfiguration | true/false | false | boolean | allow supervision URL configuration via a vendor OCPP parameter key | +| supervisionUrlOcppKey | | 'ConnectionUrl' | string | the vendor string that will be used as a vendor OCPP parameter key to set the supervision URL | +| ocppVersion | 1.6/2.0/2.0.1 | 1.6 | string | OCPP version | +| ocppProtocol | json | json | string | OCPP protocol | +| ocppStrictCompliance | true/false | true | boolean | strict adherence to the OCPP version and protocol specifications with OCPP commands PDU validation against [OCA](https://www.openchargealliance.org/) JSON schemas | +| ocppPersistentConfiguration | true/false | true | boolean | enable persistent OCPP parameters storage by charging stations 'hashId'. The persistency is ensured by the charging stations configuration files in [dist/assets/configurations](dist/assets/configurations) | +| stationInfoPersistentConfiguration | true/false | true | boolean | enable persistent station information and specifications storage by charging stations 'hashId'. The persistency is ensured by the charging stations configuration files in [dist/assets/configurations](dist/assets/configurations) | +| automaticTransactionGeneratorPersistentConfiguration | true/false | true | boolean | enable persistent automatic transaction generator configuration storage by charging stations 'hashId'. The persistency is ensured by the charging stations configuration files in [dist/assets/configurations](dist/assets/configurations) | +| wsOptions | | {} | ClientOptions & ClientRequestArgs | [ws](https://github.com/websockets/ws) and node.js [http](https://nodejs.org/api/http.html) clients options intersection | +| idTagsFile | | undefined | string | RFID tags list file relative to [src/assets](src/assets) path | +| baseName | | undefined | string | base name to build charging stations id | +| nameSuffix | | undefined | string | name suffix to build charging stations id | +| fixedName | true/false | false | boolean | use the 'baseName' as the charging stations unique name | +| chargePointModel | | undefined | string | charging stations model | +| chargePointVendor | | undefined | string | charging stations vendor | +| chargePointSerialNumberPrefix | | undefined | string | charge point serial number prefix | +| chargeBoxSerialNumberPrefix | | undefined | string | charge box serial number prefix (deprecated since OCPP 1.6) | +| firmwareVersionPattern | | Semantic versioning regular expression: https://semver.org/#is-there-a-suggested-regular-expression-regex-to-check-a-semver-string | string | charging stations firmware version pattern | +| firmwareVersion | | undefined | string | charging stations firmware version | +| power | | | float \| float[] | charging stations maximum power value(s) | +| powerSharedByConnectors | true/false | false | boolean | charging stations power shared by its connectors | +| powerUnit | W/kW | W | string | charging stations power unit | +| currentOutType | AC/DC | AC | string | charging stations current out type | +| voltageOut | | AC:230/DC:400 | integer | charging stations voltage out | +| numberOfPhases | 0/1/3 | AC:3/DC:0 | integer | charging stations number of phase(s) | +| numberOfConnectors | | | integer \| integer[] | charging stations number of connector(s) | +| useConnectorId0 | true/false | true | boolean | use connector id 0 definition from the charging station configuration template | +| randomConnectors | true/false | false | boolean | randomize runtime connector id affectation from the connector id definition in charging station configuration template | +| resetTime | | 60 | integer | seconds to wait before the charging stations come back at reset | +| autoRegister | true/false | false | boolean | set charging stations as registered at boot notification for testing purpose | +| autoReconnectMaxRetries | | -1 (unlimited) | integer | connection retries to the OCPP-J server | +| reconnectExponentialDelay | true/false | false | boolean | connection delay retry to the OCPP-J server | +| registrationMaxRetries | | -1 (unlimited) | integer | charging stations boot notification retries | +| amperageLimitationOcppKey | | undefined | string | charging stations OCPP parameter key used to set the amperage limit, per phase for each connector on AC and global for DC | +| amperageLimitationUnit | A/cA/dA/mA | A | string | charging stations amperage limit unit | +| enableStatistics | true/false | false | boolean | enable charging stations statistics | +| remoteAuthorization | true/false | true | boolean | enable RFID tags remote authorization | +| beginEndMeterValues | true/false | false | boolean | enable Transaction.{Begin,End} MeterValues | +| outOfOrderEndMeterValues | true/false | false | boolean | send Transaction.End MeterValues out of order. Need to relax OCPP specifications strict compliance ('ocppStrictCompliance' parameter) | +| meteringPerTransaction | true/false | true | boolean | enable metering history on a per transaction basis | +| transactionDataMeterValues | true/false | false | boolean | enable transaction data MeterValues at stop transaction | +| stopTransactionsOnStopped | true/false | true | boolean | enable stop transactions on charging station stop | +| mainVoltageMeterValues | true/false | true | boolean | include charging stations main voltage MeterValues on three phased charging stations | +| phaseLineToLineVoltageMeterValues | true/false | false | boolean | include charging stations line to line voltage MeterValues on three phased charging stations | +| customValueLimitationMeterValues | true/false | true | boolean | enable limitation on custom fluctuated value in MeterValues | +| firmwareUpgrade | | {
"versionUpgrade": {
"step": 1
},
"reset": true
} | {
versionUpgrade?: {
patternGroup?: number;
step?: number;
};
reset?: boolean;
failureStatus?: 'DownloadFailed' \| 'InstallationFailed';
} | Configuration section for simulating firmware upgrade support. | +| commandsSupport | | {
"incomingCommands": {},
"outgoingCommands": {}
} | {
incomingCommands: Record;
outgoingCommands?: Record;
} | Configuration section for OCPP commands support. Empty section or subsections means all implemented OCPP commands are supported | +| messageTriggerSupport | | {} | Record | Configuration section for OCPP commands trigger support. Empty section means all implemented OCPP trigger commands are supported | +| Configuration | | | ChargingStationOcppConfiguration | charging stations OCPP parameters configuration section | +| AutomaticTransactionGenerator | | | AutomaticTransactionGeneratorConfiguration | charging stations ATG configuration section | +| Connectors | | | Record | charging stations connectors configuration section | +| Evses | | | Record | charging stations EVSEs configuration section | #### Configuration section syntax example