From 856e8f67312da4acabeff1bd8452f02658a22fdb Mon Sep 17 00:00:00 2001 From: =?utf8?q?J=C3=A9r=C3=B4me=20Benoit?= Date: Mon, 13 Nov 2023 10:15:02 +0100 Subject: [PATCH] fix: ensure custom meterValues values are taken MIME-Version: 1.0 Content-Type: text/plain; charset=utf8 Content-Transfer-Encoding: 8bit Signed-off-by: Jérôme Benoit --- src/charging-station/ocpp/1.6/OCPP16ServiceUtils.ts | 2 +- 1 file changed, 1 insertion(+), 1 deletion(-) diff --git a/src/charging-station/ocpp/1.6/OCPP16ServiceUtils.ts b/src/charging-station/ocpp/1.6/OCPP16ServiceUtils.ts index 63339cf2..a752ac99 100644 --- a/src/charging-station/ocpp/1.6/OCPP16ServiceUtils.ts +++ b/src/charging-station/ocpp/1.6/OCPP16ServiceUtils.ts @@ -372,7 +372,7 @@ export class OCPP16ServiceUtils extends OCPPServiceUtils { connectorMinimumPowerPerPhase / unitDivider, ); } else { - powerMeasurandValues.L1 = powerSampledValueTemplate.value + powerMeasurandValues.L1 = isNotEmptyString(powerSampledValueTemplate.value) ? getRandomFloatFluctuatedRounded( OCPP16ServiceUtils.getLimitFromSampledValueTemplateCustomValue( powerSampledValueTemplate.value, -- 2.34.1